Dell Networking S60 and Dell Force10 S60

Similar documents
Dell Networking S6000

Dell Networking S3048-ON

Dell Networking S4048-ON

Dell Force10 S4810 Switch

Dell Force10 S4810 Switch

Dell Networking N2000 Series

Dell Networking N4000 Series and Dell PowerConnect 8100 Series

Dell EMC Networking S6010-ON

Dell EMC Networking S4148-ON and S4128-ON

Arista 7050SX-96-F. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

Dell EMC Networking S4148-ON and S4128-ON

17TB and 26TB Data Warehouse Fast Track for Microsoft SQL Server 2014 using PowerEdge R730 Server and Dell Storage PS Series PS6210S

Cisco Nexus Switch Configuration Guide for Dell SC Series SANs. Dell Storage Engineering August 2015

Microsoft SharePoint Server 2013 on Dell PowerEdge R630 with Microsoft Hyper-V Virutalization Deployment Guide

Huawei CloudEngine 6850

Best Practices for a DCB-enabled Dell M-Series Blade Solution with EqualLogic PS-M4110

Best Practices for Mixed Speed Devices within a 10 Gb EqualLogic Storage Area Network Using PowerConnect 8100 Series Switches

Cisco Nexus 5648Q. Switch Configuration Guide for Dell PS Series SANs

Cisco Nexus 9372PX. Switch Configuration Guide for Dell PS Series SANs. A Dell EMC Deployment and Configuration Guide. Dell EMC Engineering June 2017

Cisco Nexus 5648Q. Switch Configuration Guide for Dell EMC SC Series SANs

Huawei CloudEngine 6850

Cisco Nexus 9372PX. Switch Configuration Guide for Dell EMC SC Series SANs. A Dell EMC Deployment and Configuration Guide

Best Practices for Configuring Data Center Bridging with Windows Server and EqualLogic Storage Arrays

Victor Teeter Network Enabled Solutions Team

Planning and Preparation Guide

A Dell Interoperability Whitepaper Victor Teeter

Reference Architecture utilizing the PowerEdge M1000e Blade Enclosure, SQL Server and Exchange Server

Stacking Dell Force10 MXL 10/40G Blade Switches

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Dell EMC Switch Configuration Guide for iscsi and Software-Defined Storage

DEPLOYING A STACK OF DELL M-SERIES BLADE SWITCHES IN SIMPLE SWITCH MODE (SSM)

Using Switches with a PS Series Group

Best Practices for Configuring DCB with VMware ESXi 5.1 and Dell EqualLogic Storage

Switch Quick Configuration CLI Guide for

Dell and Emulex: A lossless 10Gb Ethernet iscsi SAN for VMware vsphere 5

Configuring a Dell EqualLogic SAN Infrastructure with Virtual Link Trunking (VLT)

Switch Quick Configuration CLI Guide for

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

DELL EMC READY BUNDLE FOR MICROSOFT SQL SERVER 2016

Using Switches with a PS Series Group

Dell Compellent FS8600

Deployment of Dell M8024-k Blade Switch in Simple Mode with Cisco Nexus 5k Switch

Reference Architecture for Dell VIS Self-Service Creator and VMware vsphere 4

Horizontal Stacking Software Configuration Guide for IE 5000 Switches

Switch Web GUI Quick Configuration Guide for

Dell EMC Ready Stack Deployment Guide for VMware vsphere and Unity

iscsi Boot from SAN with Dell PS Series

vstart 50 VMware vsphere Solution Specification

Configuring Interfaces

Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage

EqualLogic Storage and Non-Stacking Switches. Sizing and Configuration

Dell PS Series DCB Configuration Best Practices

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

10GbE Network Configuration

Dell EMC XC Series Networking Deployment and Best Practices Guide v2.0

DGS-3630-Series Switches

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

Dell EqualLogic Configuration Guide

Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets

Dell EMC Ready Bundle for Virtualization Deployment Guide for VMware vsan Infrastructure

A Dell technical white paper By Fabian Salamanca, Javier Jiménez, and Leopoldo Orona

HPE Synergy 40Gb F8 Switch Module

Interface and Hardware Components Configuration Guide, Cisco IOS XE Everest 16.6.x (Catalyst 9300 Switches)

Reference Architecture for Microsoft Hyper-V R2 on Dell PowerEdge M- Series Servers with EqualLogic Storage

Integrating EqualLogic PS6x10 Arrays with Existing SANs

Dell FluidFS Version 6.0 FS8600 Appliance Deployment Guide

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

Validated Components List for EqualLogic PS Series SANs

Deploying Solaris 11 with EqualLogic Arrays

Deploying Dell PowerConnect 8100 and Cisco Catalyst Switches

Dell PowerEdge M1000e Blade Enclosure and Dell PS Series SAN Design Best Practices Using Dell S-Series and M-Series Networking

Configuring EtherChannels and Link-State Tracking

Configuring Interfaces

Configuring Virtual Service Blades

Dell Active System 200 & 800

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)

Skills Assessment (OSPF) Student Training Exam

Networking in Active System 800. Dell Active System 800. And Network Architecture. Jaiwant Virk. Dell Force10 Product Management

Configuring VLANs. Understanding VLANs CHAPTER

Dell vstart 1000 Network Architecture

EqualLogic iscsi SAN Concepts for the Experienced Fibre Channel Storage Professional A Dell Technical Whitepaper

Switch Configuration Example for Q-SYS Platform Cisco Catalyst 3650 and 3850 Series

Agentless In-Band System Update With Dell OpenManage Essentials

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

DELL TM PowerVault TM DL Backup-to-Disk Appliance

Implementing Multi-Chassis Link Aggregation Groups (MC-LAG)

Abstract. Avaya Solution & Interoperability Test Lab

Deployment of VMware Infrastructure 3 on Dell PowerEdge Blade Servers

Performance Baseline for Deploying Microsoft SQL Server 2012 OLTP Database Applications Using EqualLogic PS Series Hybrid Storage Arrays

DELL TM PowerVault TM DL Backup-to-Disk Appliance

Dell EqualLogic Storage

Installing and Configuring VXLAN Gateway

Switch Configuration Example for Q-SYS Platform Extreme Networks Summit X450-G2 Series

Configuring VLANs. Understanding VLANs CHAPTER

April Brocade VDX 6740 Deployment Guide for VMware EVO:RAIL

TECHNICAL BRIEF. 3Com. XRN Technology Brief

Skills Assessment (EIGRP) Student Training Exam

Transcription:

Dell Networking S60 and Dell Force10 S60 Switch Configuration Guide for EqualLogic SANs Dell Storage Engineering September 2013 SISfeedback@Dell.com

Revisions March 2013 Initial release September 2013 Updated for firmware 8.3.3.9 2013 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell. Dell, the Dell logo, and the Dell badge, PowerConnect, EqualLogic, and Force10 are trademarks of Dell Inc. 2 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

Table of contents Revisions... 2 1 Introduction... 5 1.1 Audience... 5 1.2 Switch details... 5 1.3 Cabling diagram... 6 2 Dell recommended switch configuration... 7 2.1 Hardware configuration... 7 2.2 Delete startup configuration... 7 2.3 Configure out of band (OOB) management port... 7 2.4 Configure route for OOB management port (optional)... 8 2.5 Configure login credentials... 8 2.6 Enable switch ports... 8 2.7 Enable LLDP... 9 2.8 Enable Jumbo Frames... 9 2.9 Enable flow control... 9 2.10 Configure spanning tree on edge ports... 9 2.11 Configure port channel for LAG... 9 2.12 Configure SFP+ ports for LAG... 9 2.13 Save configuration... 10 2.14 Configure additional switch... 10 3 Optional stack configuration... 11 3.1 Delete startup configuration on first switch... 11 3.2 Configure stack on the first switch... 11 3.3 Delete startup configuration on the second switch... 11 3.4 Configure stack on the second switch... 12 3.5 Verify Stack Configuration... 12 3.6 Configure out of band (OOB) management port... 12 3.7 Configure route for OOB management port (optional)... 12 3.8 Configure login credentials... 13 3.9 Configuring switch ports... 13 3.10 Save configuration and Reload... 13 3 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

Additional resources...14 4 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

1 Introduction This document illustrates how to configure Dell Force10 S60 switches for use with EqualLogic PS Series storage using Dell best practices. The recommended configuration uses link aggregation groups (LAGs) for inter-switch connections. If you are following the Rapid EqualLogic Configuration steps at http://en.community.dell.com/techcenter/storage/w/wiki/3615.rapid-equallogic-configuration-portalby-sis.aspx, use sections 1 and 2, or 1 and 3 in this guide. For more information on EqualLogic SAN design recommendations, see the EqualLogic Configuration Guide at: www.delltechcenter.com/page/equallogic+configuration+guide. 1.1 Audience This switch configuration guide describes an optimal configuration following Dell best practices for an EqualLogic iscsi SAN and is intended for storage or network administrators and deployment personnel. 1.2 Switch details The table below provides an overview of the switch configuration. Table 1 Switch specifications Dell Networking S60 or Force10 S60 Switch vendor Dell Networking or Dell Force10 Switch model S60 Switch firmware 8.3.3.9 Note: For proper functionality, the switch must be at the switch firmware version shown in the table above before proceeding with this configuration. Using previous firmware versions may have unpredictable results. The latest firmware updates and documentation can be found at: www.force10networks.com. This site requires a login. 5 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

1.3 Cabling diagram The cabling diagram shown below represents the Dell recommend method for deploying your servers and EqualLogic arrays. Figure 1 Cabling diagram 6 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

2 Dell recommended switch configuration This section demonstrates how to configure two Dell Networking S60 or Force10 S60 switches with a LAG. The switches are interconnected by an optional dual port 10GbE SFP+ module, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP). 2.1 Hardware configuration 1. Power on the two switches. 2. Connect a serial cable to the serial port of the first switch. 3. Using Putty or another terminal utility, open a serial connection session to the switch. 4. Open your terminal emulator and configure it to use the serial port (usually COM1 but this may vary depending on your system). Configure serial communications for 9600,N,8,1 and no flow control. 5. Use optical cables to connect between the SFP+ optional modules on both switches. See this configuration in Figure 1. 2.2 Delete startup configuration Note: The following commands will delete all configuration settings. FTOS>enable FTOS#delete startup-config Proceed to delete startup-config [confirm yes/no]yes FTOS#reload System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes Note: The switch will reboot. 2.3 Configure out of band (OOB) management port FTOS>enable FTOS>#configure FTOS(conf)#interface ManagementEthernet 0/0 FTOS(conf-if-ma-0/0)#no shutdown FTOS(conf-if-ma-0/0)#ip address ipaddress mask FTOS(conf-if-ma-0/0)#exit 7 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

2.4 Configure route for OOB management port (optional) FTOS(conf)#management route X.Y.Z.0 /24 A.B.C.1 Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for the switch. If your management system is on the same subnet as the switch, the previous step may be omitted. The example above assumes a class C subnet mask. 2.5 Configure login credentials FTOS(conf)#username admin privilege 15 password 0 yourpassword FTOS(conf)#enable password level 15 0 yourpassword 2.6 Enable switch ports Option 1: You can enable ports individually by entering the port number. FTOS#configure FTOS(conf)#interface gigabitethernet 0/0 FTOS(conf-if-gi-0/0)#switchport FTOS(conf-if-gi-0/0)#no shutdown FTOS(conf-if-gi-0/0)#exit FTOS(conf)#exit Option 2: You can enable multiple ports at once using the range parameter. FTOS#configure FTOS(conf)#interface range gigabitethernet 0/0 47 FTOS(conf-if-range-gi-0/0-47)#switchport FTOS(conf-if-range-gi-0/0-47)#no shutdown FTOS(conf-if-range-gi-0/0-47)#exit FTOS(conf)#exit 8 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

2.7 Enable LLDP FTOS#configure FTOS(conf)#protocol lldp FTOS(conf-lldp)#advertise management-tlv system-capabilities FTOS(conf-lldp)#no disable FTOS(conf-lldp)#exit 2.8 Enable Jumbo Frames FTOS(conf)#interface range gigabitethernet 0/0 47 FTOS(conf-if-range-gi-0/0-47)#mtu 9252 2.9 Enable flow control FTOS(conf-if-range-gi-0/0-47)#flowcontrol rx on 2.10 Configure spanning tree on edge ports FTOS(conf-if-range-gi-0/0-47)#spanning-tree rstp edge-port FTOS(conf-if-range-gi-0/0-47)#exit 2.11 Configure port channel for LAG These commands configure the switch interconnect as a LAG. FTOS(conf)#interface Port-channel 1 FTOS(conf-if-po-1)#mtu 9252 FTOS(conf-if-po-1)#switchport FTOS(conf-if-po-1)#no shutdown FTOS(conf-if-po-1)#exit 2.12 Configure SFP+ ports for LAG These commands assign 10Gb SFP+ ports to the Port Channel. FTOS(conf)#interface range tengigabitethernet 0/48-49 FTOS(conf-if-range-te-0/48-49)#mtu 9252 9 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

FTOS(conf-if-range-te-0/48-49)#no shutdown FTOS(conf-if-range-te-0/48-49)#flowcontrol rx on FTOS(conf-if-range-te-0/48-49)#port-channel-protocol lacp FTOS(conf-if-range-te-0/48-49-lacp)#port-channel 1 mode active FTOS(conf-if-range-te-0/48-49-lacp)#exit FTOS(conf-if-range-te-0/48-49)#exit FTOS(conf)#exit 2.13 Save configuration FTOS# copy running-config startup-config 2.14 Configure additional switch Repeat the commands from section 2 to configure the second switch. 10 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

3 Optional stack configuration Note: If you wish to use a stack configuration instead of LAG, follow the instructions below instead of section 2. One advantage of stacked switches is that they can be managed as a single switch; however firmware updates will update all members of the stack simultaneously and therefore should only be done during planned downtime. 3.1 Delete startup configuration on first switch FTOS>enable FTOS#delete startup-config Proceed to delete startup-config [confirm yes/no]yes FTOS#reload System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes Note: The switch will reboot. 3.2 Configure stack on the first switch FTOS>enable FTOS#config FTOS(conf)#stack-unit 0 priority 1 FTOS(conf)#stack-unit 0 stack-group 12 FTOS(conf)#stack-unit 0 stack-group 13 FTOS(conf)#exit FTOS#copy run start FTOS#reload 3.3 Delete startup configuration on the second switch FTOS>enable FTOS#delete startup-config Proceed to delete startup-config [confirm yes/no]yes FTOS#reload System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes 11 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

Note: The switch will reboot. 3.4 Configure stack on the second switch FTOS>enable FTOS#stack-unit 0 renumber 1 Note: The switch will reboot. FTOS#config FTOS(conf)#stack-unit 1 priority 1 FTOS(conf)#stack-unit 1 stack-group 12 FTOS(conf)#stack-unit 1 stack-group 13 FTOS(conf)#exit FTOS#copy run start FTOS#reload 3.5 Verify Stack Configuration From the first switch (Master) CLI, confirm that the stack has formed: FTOS#show redundancy Note: The switch front panel will show a steady light in the MASTER LED for the Master unit, and a blinking light for the Standby unit. All next configuration step must be perform from the master switch. 3.6 Configure out of band (OOB) management port FTOS#config FTOS(conf)#interface ManagementEthernet 0/0 FTOS(conf-if-ma-0/0)#no shutdown FTOS(conf-if-ma-0/0)#ip address ipaddress mask FTOS(conf-if-ma-0/0)#no shutdown FTOS(conf-if-ma-0/0)#exit 3.7 Configure route for OOB management port (optional) FTOS(conf)#management route X.Y.Z.0 /24 A.B.C.1 12 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

Note: X.Y.Z.0 is the network your management system is connecting from and A.B.C.1 is the gateway for the switch. If your management system is on the same subnet as the switch, the previous step may be omitted. The example above assumes a class C subnet mask. 3.8 Configure login credentials FTOS(conf)#username admin privilege 15 password 0 yourpassword FTOS(conf)#enable password level 15 0 yourpassword 3.9 Configuring switch ports FTOS(conf)#interface range gigabitethernet 0/0 47 FTOS(conf-if-range-gi-0/0-47)#mtu 9252 FTOS(conf-if-range-gi-0/0-47)#switchport FTOS(conf-if-range-gi-0/0-47)#spanning-tree rstp edge-port FTOS(conf-if-range-gi-0/0-47)#flowcontrol rx on tx off FTOS(conf-if-range-gi-0/0-47)#no shutdown FTOS(conf-if-range-gi-0/0-47)#exit FTOS(conf)#interface range gigabitethernet 1/0 47 FTOS(conf-if-range-gi-1/0-47)#mtu 9252 FTOS(conf-if-range-gi-1/0-47)#switchport FTOS(conf-if-range-gi-1/0-47)#spanning-tree rstp edge-port FTOS(conf-if-range-gi-1/0-47)#flowcontrol rx on tx off FTOS(conf-if-range-gi-1/0-47)#no shut FTOS(conf-if-range-gi-1/0-47)#exit FTOS(conf)#exit 3.10 Save configuration and Reload FTOS#copy run start Reload the stack to allow settings to take effect: FTOS#reload Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. 13 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

Additional resources Support.dell.com is focused on meeting your needs with proven services and support. DellTechCenter.com is an IT Community where you can connect with Dell Customers and Dell employees for the purpose of sharing knowledge, best practices, and information about Dell products and your installations. Referenced or recommended Dell publications: Dell EqualLogic Configuration Guide: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/19852516/download.aspx Dell EqualLogic Compatibility Matrix: http://en.community.dell.com/dell-groups/dtcmedia/m/mediagallery/19856862/download.aspx For EqualLogic best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to Storage Infrastructure and Solutions Team Publications at: http://dell.to/sm4hjt 14 SCG1004 Force10 S60 Configuration Guide for EqualLogic SANs

This white paper is for informational purposes only. The content is provided as is, without express or implied warranties of any kind.