AF24-MFT (-S) US Proportional damper actuator, Spring Return Fail-Safe, Multi-Function Technology

Similar documents
Standard. Functions Functions MFT. Multi-Function Technology. Fully Customizable. Proportional Control. Pre-Set Configuration.

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

A CLOSER LOOK. Electronic Fail-Safe Series Direct Coupled Actuators. The Belimo Difference. Brushless DC Motor for Added Accuracy and Controllability

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Power consumption In operation At rest For wire sizing

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Minimum 360 in-lb torque - GK. Minimum 54 in-lb torque - NKQ. Minimum 101 lbf - AHQ. Electronic Fail-Safe Series Direct Coupled Actuators

Functional data Factory settings Variable Setting Torque Inhibiting torque

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING CONTROL

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheets

Overview of types. Technical data

Technical data sheet. Technical data

ECM3000. Control Motor

Compact Electric Actuators AC and DC Voltages 18 Nm/160 inch lbs

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Control Motor ECM3000

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Products no longer available

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

STAC5 Stepper Drives. A high performance, compact and cost-effective stepper drive with advanced features and control options

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

N05010/N10010 NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING / 2-POSITION CONTROL SPECIFICATIONS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

s Spring return C / max C

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

What Piggyback is all About. Overview of the Electrical Wiring Options for Piggyback Mounting

N20, N34 Series Non-Spring Return Direct Coupled Actuators

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

ECON-ZIP-BASE. ZIP Economizer Base Module

CDD4 Duct Carbon Dioxide Transmitter

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

THERMOSTATS & CONTROLLERS

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

VAV compact controller GDB181.1E/3 GLB181.1E/3

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Non-communicating room controllers

Motor protection relays

S05, S10, S20 Series Spring Return Direct Coupled Actuators

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Products no longer available

ASI Systems ML5740A Series

RA Electric Rotary Actuator 20 Nm to 60 Nm for butterfly valves

Actuator Commissioning Tool

General-Purpose Photoelectric Sensor

N20, N34 SERIES. NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR FLOATING / 2-POSITION CONTROL SPECIFICATIONS GENERAL FEATURES

Rotork Fairchild PAX1 Linear Actuator User s Manual

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Easy To Use OEMS Take Note

N0524/N1024, N POS/N POS

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Linear Actuators (235N)

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

VA-7700 Series. Electric Valve Actuators. Product Bulletin

VLT 2800 DRIVE SPECIFICATIONS

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

ZN230-24MP-1 MP-BUS

Specification Sheet For electronically commutated motors

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Fast Route to Reliable Energy Savings ZIP Economizer

TR150 DRIVE STANDARD FEATURES

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

EC centrifugal module - RadiPac

TC-9102 Terminal Controller

Andover ContinuumTM Infinet II

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

MODCELL 2050R Single Loop Controllers

Non-communicating room controllers

EC centrifugal module - RadiPac

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

FCU-4 FAN COIL CONTROLLER

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Transcription:

AF4-MFT (-S) US Proportional damper actuator, Spring Return Fail-Safe, Multi-Function Technology Torque min. in-lb Control to 0 VDC (DEFAULT) Feedback to 0 VDC (DEFAULT) Application For proportional modulation of dampers and control valves in HVAC systems. The AF4-MFT US provides mechanical spring return operation for reliable fail-safe application. LISTED 94D5 TEMP. IND & REG. EQUIP. UL AF4-MFT US Technical Data AF4-MFT (-S) US Power supply 4 VAC, ± 0%, 50/60 Hz 4 VDC, ±0% Power consumption.5 W holding 6 W running Transformer sizing 0 VA (Class power source) Electrical ft, 8 GA, appliance cable, connection / conduit connector Overload protection electronic throughout 0 to 95 rotation Operating range Y* to 0 VDC 4 to 0 ma (w/500 Ω, /4 W resistor) ZG-R0 Input impedance 00kΩ for to 0 VDC (0. ma) 500Ω for 4 to 0 ma 500Ω for PWM, Floating point and On-Off control Feedback output U* to 0 VDC, 0.5 ma max Torque min in-lb (5 Nm) Direction of rotation* spring: reversible with cw/ccw mounting motor: reversible with built-in switch Mech. angle of rotation* 95, adjustable 5 to 95 w/zdb-af Running time motor* 50 seconds constant Running time spring <0 sec spring return fail safe position Angle of Rotation Off (Default) Adaptation* Override control* Min. (Min Position) = 0% - ZS (Mid. Position) = 50% - Max. (Max. Position) = 00% Position indication visual indicator, 0 to 95 (0 is spring return position) Auxiliary switches x SPDT 7A (.5A) @ 50 VAC, UL listed (AF4-MFT-S US) one set at +5, one adjustable 5 to 85 Manual override mm hex crank (supplied) Humidity 5 to 95% RH, non-condensing Ambient temperature - to + F (-0 to +50 C) Storage temperature -40 to +76 F (-40 to +80 C) Housing NEMA, IP54 Housing material zinc coated metal Noise level less than 45 db (A) Agency listings UL 87 listed, CE, CSA C. No. 4 certified Quality standard ISO 900 Servicing maintenance free Weight 6.0 lbs. (.7 kg.) * Variable when configured with MFT options Default/Configuration Default parameters for to 0 VDC applications of the AF4-MFT US actuator are assigned during manufacturing. If required, custom versions of the actuator can be ordered. The parameters noted in the Technical Data table are variable. These parameters can be changed by three means: Pre-set configurations from Belimo Custom configurations from Belimo Configurations set by the customer using the MFT-Handy or the MFT-Actuate PC software application. Operation The AF4-MFT US actuator provides 95 of rotation and is provided with a graduated position indicator showing 0 to 95. The actuator will synchronize the 0 mechanical stop or the physical damper or valve mechanical stop and use this point for its zero position during normal control operations. A unique manual override allows the setting of any actuator position within its 95 of rotation with no power applied.this mechanism can be released physically by the use of a crank supplied with the actuator. When power is applied the manual override is released and the actuator drives toward the fail-safe position. The actuator uses a brushless DC motor which is controlled by an Application Specific Integrated Circuit (ASIC) and a microprocessor. The microprocessor provides the intelligence to the ASIC to provide a constant rotation rate and to know the actuator s exact position. The ASIC monitors and controls the brushless DC motor s rotation and provides a Digital Rotation Sensing (DRS) function to prevent damage to the actuator in a stall condition. The position feedback signal is generated without the need for mechanical feedback potentiometers using DRS. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AF4-MFT US is mounted directly to control shafts up to.05" diameter by means of its universal clamp and anti-rotation bracket. A crankarm and several mounting brackets are available for damper applications where the actuator cannot be direct coupled to the damper shaft. The spring return system provides minimum specified torque to the application during a power interruption. The AF4-MFT US actuator is shipped at +5 (5 from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. Note: Please See Documentation on Multi-Function Technology (pg 55) Dimensions [All numbers in brackets are in millimeters.] K4- US (supplied) /" Centered (Default) /4" Centered (Field Selectable).05" Centered (Field Selectable) K4- US (optional) /4" to.05" Adjustable K4 US (optional) /8" to /4" Adjustable 0.65" [6.5].86" [98].0" [78].5" [80].4" [57] 0.9" [5] 0.9" [0] 0.5" [9].64" [67].97" [50] 0.59" [69] 5.85" [48.5] 0.6" [6.5].9" [49] D00 I068 - Subject to change. Belimo Aircontrols (USA), Inc. 8

AF4-MFT (-S) US Proportional damper actuator, Spring Return Fail-Safe, Multi-Function Technology I068 - Subject to change. Belimo Aircontrols (USA), Inc. 4 VAC Transformer Control Signal ( ) to 0 VDC to 0 VDC Feedback Signal 4 VAC Transformer Control Signal ( ) A to 0 VDC A Open = 0 V Position A Closed = Normal Operation 4 VAC Transformer Control Signal ( ) B to 0 VDC C B Closed = 0 V Position C Closed = Normal Operation Override to zero position Ω Standard Wiring Blk () Common Red () + Hot Wht () Y Input, to 0V Wht (5) U Output, to 0V CCW(L) CW(R) Blk () Common Red () + Hot Override to 0 V position Wht () Y Input, to 0V Blk () Common Red () + Hot Wht () Y Input, to 0V Override control to min, mid, max, positions 4 VAC Transformer Control Signal ( ) -0 VDC or 4 to 0 ma 500Ω 4 /4 watt A B C Blk () Common Red () + Hot Wht () Y Input, to 0V Functions a b c Min* Mid* Max* Normal** 0% 50% 00% Control mode acc. to Y * Default selectable 0-00%. See Configuration Data Sheet. ** Customizable. See Configuration Data Sheet. to 0 VDC Control Signal W0 4 VAC Transformer Control Signal 4 to 0 ma ( ) 4 Standard Wiring Ω 500Ω /4 watt A Open = 4 ma Position A Closed = Normal Operation Blk () Common Red () + Hot Wht () Y Input, to 0V Wht (5) U Output, to 0V Override to zero position 4 VAC Transformer Blk () Common Red () + Hot Ω 500Ω /4 watt Control Signal ( ) 4 to 0 ma 4 A Wht () Y Input, to 0V Override to 0 ma position 4 VAC Transformer Blk () Common Red () + Hot Ω B Control Signal ( ) 4 to 0 ma Wht () Y Input, to 0V 500Ω C 4 /4 watt B Closed = 0 ma Position C Closed = Normal Operation 4 to 0 ma Control Signal Auxiliary Switch AF4-MFT-S US Notes 4 5 6 CCW(L) CW(R) With a 4-0 ma Input, up to 4 actuators may be wired in parallel. A % shift in the signal is seen when using a 500Ω resistor. Power consumption must be observed. Provide overload protection and disconnect as required. Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Actuator may also be powered by 4 VDC. ZG-R0 may be used. For end position indication, interlock control, fan startup, etc., AF4-MFT-S US incorporates two built-in auxiliary switches: x SPDT, 7A (.5A) @50 VAC, UL listed, one switch is fixed at +5, one is adjustable 5 to 85. Meets UL and CSA requirements without the need of an electrical ground connection. S S S S4 S5 S6 NC NO NC NO 5 5 6 5 to 85 W04 W0 AF 9

Flexible Products Ordering Ordering example Non-Spring Return The ordering process for the new Flexible non-spring return actuators is simple. First select a base actuator that meets the needs of the application and then add the desired options.. Base actuator LMX4-MFT (LM00) Select a base actuator Torque or linear force, control input, position feedback, power supply See page 40 for complete list of non-spring base actuators.. Clamp option /4 dia. universal clamp (6) Select clamp that accommodates the damper shaft LM defaults to a 5/8" dia. clamp, but the /4" option can be selected as seen in this example. NM and AM default to a /" dia. clamp that also accommodates /4" and.05" dia. shafts. GM accommodates a.05" dia. shafts. A /4" dia. clamp is available for retrofits of past GM and SM types.. Electrical Connection option 6 ft. [5m] 8 GA, plenum rated cable (C5) Default connection is a ft. [m] long cable. 0 ft [m] or 6ft [5m] cables are also available. Actuators with a "-T" in the model number have a screw terminal strip, which default to a NEMA enclosure rating. A NEMA cover for the terminal strip can be selected. 4. Programming P-000 (W0) For and SR type actuators only the running time can be changed. This is a one-time factory setting. For MFT type actuators refer to page 4 for available configurations. 5. Total LMX4-MFT (LM00 6 C5 W0) Ordering example Spring Return. Base actuator AF4-MFT-S US Select a base actuator I068 - Subject to change. Belimo Aircontrols (USA), Inc.. Programming P-000 (A0) 0 VDC input / 0 5 VDC feedback Select pre-set programming code P-00xx (Axx) Control voltage applications P-00xx (Wxx) Pulse width modulation applications P-00xx (Fxx) Floating point applications P-400xx (Jxx) On/Off applications Or create custom MFT configuration codes, see page 4 Or create custom MFT configurations in the field with MFT-Actuate PC software.. Total AF4-MFT-S US + P000 Order confirmation and invoice example for spring return actuators: Item Model Qty 0 AF4-MFT US 0 P-000 0 LF4-MFT US 0 P-000 0 AF4-MFT US 5 P-0006 40 9998-0000 5 The part number 9998-0000 is a requirement for Belimo as a designation for all the configurations in an order. This product s description will read MFT CONFIGURATION CHARGE, (P- / V- ). It is used to confirm the correct quantities and to invoice the proper fee for the MFT configurations. The total quantity of configurations is represented in this one line item.the product line item will list the specific configuration below the actuator ordered. If you have more than one model with multiple configurations, each change in configuration will be shown on separate line items. As an example lines 0 and 0 are the same model actuator with different configurations. 57

Flexible Actuator Selection At A Glance Spring Return MFT Actuators Model Description MFT Configuration AF 4 MFT S US Programming Code Auxiliary Switch S Built-In Power Supply 4 VAC/DC Electrical Connection US ft Cable Control Type -MFT -MFT95 Multi-function Technology 0 to 5 ohm -MFT-0 6 to 9 VDC 0 VDC power supply Actuator family and torque output Actuator AF4-MFT US AF4-MFT-S US AF4-MFT95 US NF4-MFT US LF4-MFT US LF4-MFT-S US LF4-MFT-0 US LF4-MFT-S-0 US Torque in-lb 60 in-lb 5 in-lb Code A0 P-000 A0 P-000 A0 P-000 A8 P-008 W0 P-000 W0 P-000 Options Description (MFT Only) F0 P-000 Common or default configurations are configured at no charge. Uncommon or custom codes will be configured by Belimo for a $0.00 list add to each actuator. See page 4 for an extended list of MFT programming codes. I068 - Subject to change. Belimo Aircontrols (USA), Inc. 58

Pre-set MFT Configurations DC Voltage Control, P-000 (A ) Spring Return AF4-MFT(-S) US in-lb NF4-MFT US 60 in-lb Non-Spring Return GMX4-MFT 60 in-lb AMX4-MFT 80 in-lb LF4-MFT(-S) US 5 in-lb LF4-MFT(-S)-0 US 5 in-lb NMX4-MFT 90 in-lb LMX4-MFT 45 in-lb Application P-000 configuration types are used for VDC control applications. Pre-set configurations are listed which offer solutions for standard control applications. Additional pre-set configurations are listed which offer solutions for non-standard control application for: Adjustable Start and Stop points Sequencing actuators Combination for master slave Wiring VDC 4 VAC/DC Transformer () Common () + Hot LISTED 94D5 TEMP. IND & REG. EQUIP. UL W040 Control Signal Position Feedback ( ) ( ) () Y Input (5) U Output Select a Configuration Configration Input Position Running Torque Description Code Range Feedback Time % Adaptation P-000* A0.0 to 0.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-000 A0 0.5 to 0.0 VDC 0.0 to 0.0 VDC 50 00 MANUAL P-000 A0.0 to 0.0 VDC 0.0 to 5.0 VDC 50 00 MANUAL P-0004 A04 4.0 to 7.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-0005 A05 6.0 to 9.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-0006 A06 0.5 to.5 VDC.0 to 0.0 VDC 50 00 MANUAL P-0007 A07 0.5 to 5.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-0008 A08 0.5 to 5.0 VDC 0.0 to 0.0 VDC 50 00 MANUAL P-0009 A09 5.0 to 0.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-000 A0 5.0 to 0.0 VDC 0.0 to 0.0 VDC 50 00 MANUAL P-00 A 0.5 to 0.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-005 A5.0 to 5.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-006 A6.0 to 6.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-007 A7 6.0 to 0.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-008 A8 4 to 7 VDC.0 to 0.0 VDC 50 00 MANUAL P-000 A0 9.0 to.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-008 A8 0.5 to 0.0 VDC 0.0 to 0.0 VDC 00 00 MANUAL P-00 A 0.5 to 4.0 VDC.0 to 0.0 VDC 50 00 MANUAL P-006 A6 0.5 to 4.5 VDC 0.5 to 4.5 VDC 50 00 MANUAL P-0064 A64 5.5 to 0.0 VDC 5.5 to 0.0 VDC 50 00 MANUAL P-009 A9.0 to 0.0 VDC.0 to 0.0 VDC 95 00 MANUAL * P-000 (A0) is the default configuration code. VOLTAGE I068 - Subject to change. Belimo Aircontrols (USA), Inc. 64

Pre-set MFT Configurations Pulse Width Modulation Control, P-000 (W ) Spring Return AF4-MFT(-S) US in-lb NF4-MFT US 60 in-lb LF4-MFT(-S) US 5 in-lb LF4-MFT(-S)-0 US 5 in-lb Application P-000 configuration types are used for Pulse Width Modulation control outputs. Most D.D.C. controllers have digital outputs which incorporate a default PWM range. This enables a D.O. to be used as a proportional output when needed. Simply select the appropriate configuration code according to your application. Non-Spring Return GMX4-MFT 60 in-lb AMX4-MFT 80 in-lb NMX4-MFT 90 in-lb LMX4-MFT 45 in-lb Wiring PWM, triac source and sink 4 VAC Transformer (AC only) LISTED 94D5 TEMP. IND & REG. EQUIP. UL W04 () Common () + Hot Position Feedback VDC ( ) () Y Input (5) U Output Control signal may be pulsed from either the Hot (Source) or Common (Sink) 4 VAC line Position feedback cannot be used with a Triac sink controller. The actuators internal common reference is not compatible. I068 - Subject to change. Belimo Aircontrols (USA), Inc. Select a Configuration Configration Input Position Running Torque Description Code Range Feedback Time % Adaptation P-000 W0 0.59 to.9 sec.0 to 0.0 VDC 50 00 MANUAL P-000 W0 0.0 to 5.00 sec.0 to 0.0 VDC 50 00 MANUAL P-000 W0 0.0 to 5.50 sec.0 to 0.0 VDC 50 00 MANUAL P-0004 W04 0.0 to 5.60 sec.0 to 0.0 VDC 50 00 MANUAL P-0005 W05 0.0 to 5.0 sec 0.0 to 5.0 VDC 50 00 MANUAL P-00 W 0.50 to 5.50 sec 0.0 to 0.0 VDC 50 00 MANUAL P-00 W 0.50 to.9 sec 0.0 to 5.0 VDC 50 00 MANUAL P-004 W4 0.0 to 0.00 sec.0 to 0.0 VDC 50 00 MANUAL PULSE WIDTH MODULATION MFT 65

Pre-set MFT Configurations Floating Point Control, P-000 (F ) Spring Return AF4-MFT(-S) US in-lb NF4-MFT US 60 in-lb LF4-MFT(-S) US 5 in-lb LF4-MFT(-S)-0 US 5 in-lb Application P-000 configuration types are used for floating point control outputs. In this application MFT actuators offer constant running time and standard feedback options. A IN4004 or IN4007 diode is required for spring return actuators only. Non-Spring Return GMX4-MFT 60 in-lb AMX4-MFT 80 in-lb NMX4-MFT 90 in-lb LMX4-MFT 45 in-lb Wiring Floating Point 4 VAC Transformer (AC only) Hot Triac Source Wiring 6 COM Diode may be placed at the control panel. Reduces field wiring () Common () + Hot () Y Input LISTED 94D5 TEMP. IND & REG. EQUIP. UL W04 A (5) U Output 4 VAC Transformer (AC only) Diode may be placed at the control panel. Reduces field wiring W04A Controller B IN4004 or IN4007 diode. (IN4007 supplied, Belimo part number 4055) Position Feedback Direction of rotation switch CCW CCW Select a Configuration Configration Input Position Running Torque Description Code Range Feedback Time % Adaptation P-000 F0 Floating Point.0 to 0.0 VDC 50 00 MANUAL P-000 F0 Floating Point 0.0 to 0.0 VDC 50 00 MANUAL P-000 F0 Floating Point.0 to 0.0 VDC 00 00 MANUAL P-0004 F04 Floating Point 0.0 to 5.0 VDC 00 00 MANUAL P-0005 F05 Floating Point 0.0 to 0.0 VDC 00 00 MANUAL P-0006 F06 Floating Point 0.0 to 5.0 VDC 50 00 MANUAL P-0007 F07 Floating Point.0 to 0.0 VDC 00 00 MANUAL P-0008 F08 Floating Point.0 to 0.0 VDC 75 00 MANUAL P-0009 F09 Floating Point.0 to 0.0 VDC 85 00 MANUAL P-000 F0 Floating Point 0.0 to.5 VDC 50 00 MANUAL FLOATING POINT CONTROL Triac Sink Wiring 6 Hot Controller COM A B Position Feedback () Common () + Hot () Y Input (5) U Output Note: Diode is internal on non-spring return type actuators, connect to controller using wires and 4. 4 5 4 5 6 Triac A and B can also be contact closures. Why is a diode required? The actuator is designed to recognize the rectified voltage as an opposite control signal request. CW A B Position feedback cannot be used with a Triac sink controller. The actuators internal common reference is not compatible. The Common connection from the actuator must be connected to the Hot Connection of the controller. The actuator Hot must be connected to the control board Common. MFT actuators are compatible with contact closure, triac source and triac sink type contollers. CW A B Note: Diode is internal on non-spring return type actuators, connect to controller using wires and 4. I068 - Subject to change. Belimo Aircontrols (USA), Inc. 66

Pre-set MFT Configurations On/Off Control, P-4000 (J ) Spring Return AF4-MFT(-S) US in-lb NF4-MFT US 60 in-lb LF4-MFT(-S) US 5 in-lb LF4-MFT(-S)-0 US 5 in-lb Application P-4000 configuration types are used for on/off control outputs. The configuration allows for service replacement of on/off actuators when a true on/off actuator is not available. In addition the MFT actuator offers additional functionality in the on/off mode, such as configuration P-4000 with minimum position and to 0 VDC feedback. Non-Spring Return GMX4-MFT 60 in-lb AMX4-MFT 80 in-lb NMX4-MFT 90 in-lb LMX4-MFT 45 in-lb Wiring Two Position 4 VAC/DC Transformer LISTED 94D5 TEMP. IND & REG. EQUIP. UL W04 () Common () Hot Position ( ) Feedback VDC a () Y Input (5) U Output I068 - Subject to change. Belimo Aircontrols (USA), Inc. Select a Configuration Configration Input Position Running Torque Description Code Range Feedback Time % Adaptation P-4000 J0 On/Off.0 to 0.0 VDC 75 00 MANUAL P-4000 J0 On/Off.0 to 0.0 VDC 50 00 MANUAL P-4000 J0 On/Off.0 to 0.0 VDC 75 00 MANUAL P-40004 J04 On/Off 0.0 to 5.0 VDC 00 00 MANUAL P-40005 J05 On/Off 0.0 to 0.0 VDC 00 00 MANUAL ON/OFF CONTROL MFT 67

Multi-Function Technology Specifications For all MFT Type Actuators. Control Specifications Parameter Variables Description VDC Start: 0.5 to 0 VDC P-00 (A ) configuration types are used for VDC control Stop:.5 to VDC applications. Pre-set configurations are listed (Minimum VDC between which offer solutions for standard control applications. start and stop required) Additional pre-set configurations are list which offer solutions for non-standard control application for: Sequencing Actuators Adjustable Start and Stop Points Combination for Master Slave INPUT Pulse Width PWM Range P-00 (W ) configuration types are used for pulse width Modulation (PWM) 0.0 to 50 sec. range modulation control outputs with four standard ranges. minimum interval There must be at least one second between the min pulses 0 [ms] between pulses allowed (0.0 sec.) and the max pulse allowed (50 sec.). Minimum cycle duration 50 [ms] (eg: 0.0 to.0 sec.) Floating Point P-00 (F...) configuration types are used for floating point control outputs. In this application MFT actuators offer constant running time and standard feedback options. A N4004 diode is required for spring return actuators. The actuator is designed to recognize the rectified voltage as an opposite control signal request. On/Off P-400 (J ) configuration types are used for on/off control outputs. The configuration allows for service replacement of on/off actuators when a true on/off actuator is not available. In addition the MFT actuator offers additional functionality in the on/off mode, such as configuration P-4000 (J0) with minimum position and to 0 VDC feedback. FEEDBACK SENSITIVITY Position Position Feedback Range The default-operating mode of the U5 output is to 0 VDC Feedback Start: 0.5 to 8 VDC Selectable for position feedback. Matching the controllers feedback input Stop: to 0 VDC Selectable voltage is possible by selecting a pre-set configuration (page 78) or by creating a custom configuration (page 79). Control Normal (Default) MFT actuators are designed with a unique non-symmetrical Sensitivity dead band. The actuator follows an increasing control signal with a 80 mv resolution. If the signal changes in the opposite direction, the actuator will no respond until the control signal changes by 00 mv. This allows the MFT actuator to track even the slightest deviation very accuratly, yet allowing the actuator to "wait" for a much larger change in control signal. See figure. Reduced Upon detecting an un-stable control loop, the "reduced" setting can be manually selected via the PC software. This will reduce the sensitivity of the actuator by 50%. Meaning, control accuracy will now be 60 mv for signal changes in the same direction. And a 400 mv signal change in the opposite direction is needed for the actuator to change direction. Once driving in the opposite direction the actuator will respond in 60 mv increments. Upon improving the control loop stability you can return the actuator to the "Normal" mode. I068 - Subject to change. Belimo Aircontrols (USA), Inc. 68

Multi-Function Technology Specifications For all MFT Type Actuators. Figure Control Accuracy and Stability (AF / NF / LF) All MFT actuators have built-in brushless DC motors which provide better accuracy and longer service life. The US actuators are designed with a unique non-symmetrical deadband. The actuator follows an increasing or decreasing control signal with a 40 mv resolution. If the signal changes in the opposite direction, the actuator will not respond until the control signal changes by 00 mv. This allows these actuators to track even the slightest deviation very accurately, yet allowing the actuator to wait for a much larger change in control signal due to control signal instability. AF / NF / LF Actuators responds to a 40 mv signal when not changing direction from stop position. AF / NF / LF Actuators responds to a 00 mv signal when reversing direction from stop position. Satisfied Control Position 40 mv Minimum Reversed Control Deadband Prior to Normal Control 00 mv Minimum Control Resolution Satisfied Control Position Control Accuracy and Stability (GM / AM / NM / LM / AH / LH / LU) All Belimo actuators have built-in brushless DC motors which provide better accuracy and longer service life. I068 - Subject to change. Belimo Aircontrols (USA), Inc. Belimo non-spring return actuators are designed with a unique non-symmetrical deadband. The actuator follows an increasing or decreasing control signal with a 75 mv resolution. If the signal changes in the opposite direction, the actuator will not respond until the control signal changes by 75 mv. This allows these actuators to track even the slightest deviation very accurately, yet allowing the actuator to wait for a much larger change in control signal due to control signal instability. Actuator responds to a 75 mv signal when not changing direction from stop position. Satisfied Control Position 75 mv Minimum Control Resolution Actuator responds to a 75 mv signal when reversing direction from stop position. Minimum Reversed Control Deadband Prior to Normal Control 75 mv Satisfied Control Position MFT 69

Multi-Function Technology Specifications For all MFT Type Actuators. Motion Specifications Parameter Variables Description RUNNING TIME AF / NF / LF GM AM NM LM 75 to 00 seconds 70 to 80 seconds 90 to 50 seconds 45 to 70 seconds 5 to 50 seconds Running time is selectable allowing for customizing the actuator for the application at hand. Adjustable running time allows for: Matching HVAC system sequence of operation. Improving control loop stability. Reducing actuating noise (slower running). Retrofit applications The running time is constant and independent of load. Direction of Rotation Default or Reversed The direction of rotation can be "Direct" or "Reverse" acting of the control signal. The direction of rotation is selected from a CW and CCW switch located on the actuator. An alternative method of changing the direction of rotation is to use the PC-Tool software. This option allows you to make remote set-up corrections without having the need to be at the actuator. Selection of the direction of rotation is only possible via the PC-Tool software or manually with the switch on the actuator. Selection via a preset configuration is not an option. ROTATION Intermediate Position Control (Override Control) Figure - Forced Overrides OPEN (00%) Max. 70% Min. 0% [%] Minimum Position (Default 0%) Intermediate Position (Default 50%) Maximum Position (Default 00%) Intermediate Positions are achieved through forced override positions. See Figure Forced Overrides. -0 VDC Normal control mode CLOSE (0%) 0 4 5 6 7 8 9 0 Controlrange 00% 0% Y [ VDC ] Full control signal range is maintained between min and max rotation positions. i.e.: AM4-MFT on Belimo CCV, adjusting actuator to damper flow characteristics. 4 VAC Transformer All intermediate settings are adjustable from 0 to 00%. Programmed as default, these control positions are possible by using the wiring diagram in Figure. The override functions can be sued as a means to test the actuator s functionality during equipment servicing or troubleshooting. Intermediate positions can also be integrated into the control circuit as a part of the sequence of operation. The Min, Mid, and Max positions can be used in any MFT control mode. VDC: For stand-alone controllers where a minimum position is needed. PWM: Eliminate add-on accessories. Floating Point: New functionality to a common application. On/Off: New functionality to a common application. Satisfy combustion air requirements or boiler sequencing with O/A damper. Eliminates secondary minimum position dampers. A B C D E 5 Blk Red Wht Wht + Y U 5 F Controller 0 0 VDC + Position Feedback 0 VDC (Default) Digital Output, Relay Contacts, Multiple Position Switch Example Position Switch Position 0% Close A 0% Minimum B 50% Mid C 70% Maximum D 00% Open E 0 VDC Normal F IN4004 diode required. One each for switch position C&E where indicated I068 - Subject to change. Belimo Aircontrols (USA), Inc. 70

Multi-Function Technology Specifications For all MFT Type Actuators. Motion Specifications Parameter Variables Description Adaptation OFF When the manual override button is depressed, and released, the actuator will perform synchronization. The actuator will simply drive to the mechanical zero position and return to its last control position. ON Manual ON Automatic The default setting for adaptation is ON Manual. When the ON-Manual setting is selected, adaptation is initiated by: Pressing the manual override button twice (GM / AM / NM / LM). Clicking the manual override crank twice (AF). Clicking the CW/CCW switch twice (NF and LF). When adaptation is selected, (On-Manual or Automatic) the actuator will drive one full cycle to its mechanical end stops OR the valves mechanical seats. Upon completion of this cycle the actuators working range (input, feedback and running time) will be adapted to the actual mechanical angle of rotation. When the ON-Automatic setting is selected at every power-up the actuator will automatically adapt to the mechanical angle of rotation. Also upon pressing the manual override button or CW/CCW switch, adaptation is initiated (See above). I068 - Subject to change. Belimo Aircontrols (USA), Inc. Mechanical Relationship Figure 4 Sound and Running Time Torque and Running Time Torque and Run Time, AF4-MFT US TORQUE [in-lb] 6 67 5 All Actuators Spring Return (AF / NF / LF) 00 % torque curve Torque and Run Time, NF4-MFT US TORQUE [in-lb] 60 45 As the speed of the actuator increases, there is an increase in the sound power level. Though the running time remains constant, at approximately the 00-second range there is a loss in output torque. This is due to the association of runtime to torque. To gain a faster running time there is a loss in torque. See figure 4 00 % torque curve Torque and Run Time, LF4-MFT US TORQUE [in-lb] 5 6 00 % torque curve MFT 75 00 50 Running time [s] 75 00 50 Running time [s] 75 00 Running time [s] 50 7

Multi-Function Technology Specifications For all MFT Type Actuators. Sevice Specifications Parameter Variables Description DISPLAYS FUNCTIONS Identification Actual Values Function Data Log Sensitivity Messages Function Test Adaptation Synchronization Serial Number Actuator Type / Software Version Assembly Location Setpoint Actual Control Type & Setting Feedback Type & Setting Torque % Setting Running Time Direction of Rotation Min, Mid, Max Position Adaptation Sensitivity / Hysteresis Synchronization Total Time / Operating Time Active Time Stop / Go Ratio (Hunting %) Normal, Reduced See Adaptation on page 7. Normal Sync at 0% Sync at 00% Displays the actuators internal serial number. The serial number is also printed on a label at the side of the actuator. Displays the actuator nomenclature (AF4-MFT US) and MFT software version. Displays the where the actuator was assembled. Displays the actual control input position as a percentage. As signal input changes you will see the setpoint percentage change accordingly. Displays the actual position as a percentage. As the setpoint changes the actual position percentage will increase or decrease accordingly. If the actuator is capable of rotating the damper or valve, this can be of benefit when troubleshooting an application. Displays the actual control type and operating range. Displays the actual feedback signal type and operating range. Displays the actual torque setting. Displays the actual running time as programmed. Displays the status of the direction of rotation option (Normal or Reversed). Displays the actual position setting of the Intermediate position control. See page 70 for more details. Displays the actual setting of the adaptation function (OFF, ON-Manual, ON-Automatic). See page 7 for more information. Displays the actual setting of the sensitivity button (Normal or Reduced). Displays the actual setting of the synchronization function (Normal, Sync at 0%, Sync at 00%). Total number of hours the actuator is connected to a power supply. Total number of hours the actuator is in mechanical motion. Displays a percentage the total number of hours the actuator has spent in mechanical motion, comparing the total time to the active time. Displays the setting of the sensitivity function. See page 68 for more information. Displays all messages present. Messages can be deleted as well. This function enables you to check for complete opening and closing of the actuator. The test report contains: Information on the Project Identification on the Actuator A list of fault messages pending before the start of the test The test steps and results The current actuator settings This is of benefit when troubleshooting an application, as the actuator will drive the damper or valve. This gives an opportunity to observe the installation to identify any possible problems. Initiates the adaptation feature of the MFT actuator. The actuators working range (input, feedback, and running time) will be adapted to the actual angle of rotation. This is of benefit when troubleshooting an application, as the actuator will drive the damper or valve. This gives you an opportunity to observe the installation to identify any possible problems. At initial commissioning, when the manual override button is pressed, the actuator runs to a default position defined by the position of the CW/CCW direction of rotation switch. At each power-up (includes power failures), the actuator runs to a default position defined by the position of the CW/CCW direction of rotation switch. At each power-up (includes power failures), the actuator runs to a default position of the CW/CCW direction of rotation switch. I068 - Subject to change. Belimo Aircontrols (USA), Inc. 7

Wiring Multiple MFT Actuators I068 - Subject to change. Belimo Aircontrols (USA), Inc. ATTENTION Please note the method of wiring multiple Belimo US actuators to a single control shaft for damper and valve applications. MFT= Master-Slave Applications which require more torque than one actuator is a very common installation. The current Belimo solution is to mount multiple actuators onto the damper or valve. In the past this required the installer to wire the actuators in a masterslave arrangement. This was typical for the AF4-SR US actuator. By adding more actuators you can effectively increase the torque proportional to the minimum specified torque times the number of actuators. This is a normal installation typically seen on the following installations. Large dampers or valves Large multiple section dampers Rack and Pinion style globe valves Ball or Butterfly valves For retro-fit of an existing AF4-SR US which is wired in Master- Slave, rewire the installation so the remaining AF4-SR US is now the Master and the new AF4-MFT US is the Slave. Multiple actuators mounted to one control shaft Max. Qty Torque Model Per Shaft Generated AF4-MFT(-S) US 4 5 in-lb NF4-MFT(-S) US 60 in-lb LF4-MFT(-S) US 5 in-lb GMX4-MFT 70 in-lb AMX4-MFT 80 in-lb NMX4-MFT 90 in-lb LMX4-MFT 45 in-lb The wiring method for multiple actuators mounted to shafts which are not mechanically connecting other actuators is to wire the control signal in parallel with each actuator Multiple XM4-MFT95 Exception: No mechanical dual mounting of AF4-MFT95 US is possible. Electrical parallel wiring of AF4-MFT95 US is possible only for mechanically separate applications. Solution: For increased torque requirement use AF4-MFT95 US as a master and the slave must be an AF4-MFT US. The masters feedback must match the slaves input signal. (Both are default -0 VDC.) Notes Provide overload protection and disconnect as required. Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 4 5 Actuator may also be powered by 4 VDC. ZG-R0 may be used. Control signal may be pulsed from either the Hot or Common 4 VAC line. 4 VAC Transformer Ω Control Signal ( ) to 0 VDC or 4 to 0 ma 500Ω 4 /4 watt Maximum 4 actuators Maximum 4 actuators per shaft, see per shaft. chart on this page. Notes Master () Common () + Hot () Y Input, to 0 V (5) U Output to 0 V Slave () Common () + Hot () Y Input, to 0 V (5) U Wiring multiple actuators to one shaft. All MFT actuators are wired in master-slave configuration. Wiring of multiple actuators on valves must be masterslave (wires -5). MFT actuator configurations should also co-ordinate with each other. Meaning the master input = controllers output. Master output = slave input. Slave output = controller input. Position Feedback VDC 0 to 5 VDC Notes 4 VAC Transformer ( ). to 5.5 sec 5 Master () Common () + Hot () Y Input (5) U Output to 0 VDC Slave () Common () + Hot () Y Input to 0 VDC (5) U Output 0 to 5 VDC Controller Master Slave Slave Output Feedback Input Feedback 0. to 5.5 sec to 0 VDC to 0 VDC 0 to 5 VDC W046 W4 MFT 77