User s Manual Model FX103/FX106/FX112 FX100(Desktop Type) * 4 L 2 0 A 1 5 1 E 0 1 * Yokogawa Electric Corporation 1st Edition
Forword Notes Trademarks Revisions Thank you for purchasing the FX100. This user s manual contains information about FX100 instruments with the /H5 option specification (the desktop type). Please also refer to the user s manual for the standard version of the FX100 (IM04L20A01-01E) when operating this model. The contents of this manual are subject to change without prior notice as a result of continuing improvements to the instrument s performance and functions. Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact your nearest YOKOGAWA representative. Copying or reproduction of all or any part of the contents of this manual without the permission of Yokogawa Electric Corporation is strictly prohibited. Adobe, Acrobat, and PostScript are trademarks of Adobe Systems Incorporated. The company and product names used in this manual are not accompanied by the trademark or registered trademark symbols ( and ). Company and product names used in this manual are trademarks or registered trademarks of their respective holders. 1st edition March 2004 1st Edition : March 2004 (YK) All Rights Reserved, Copyright 2004 Yokogawa Electric Corporation 1
Safety Precautions The following describes warnings that are specific to the desktop type. Please also refer to pages ii and iii of IM04L20A01-01E for warnings that apply to all models of the instrument. WARNING Power Supply Before connecting the power cord, ensure that the power supply voltage matches the voltage rating for the instrument, and that it is within the maximum rated voltage for the power cord itself. Use the Correct Power Cord and Plug The main power plug can only be plugged into an outlet with a protective grounding terminal. Do not disable the protection feature of the instrument by using an extension cord without protective grounding. Connect the Protective Grounding Terminal Make sure to connect the protective grounding to prevent electric shock before turning ON the power. The power cord included with the desktop type is a 3- prong cord with a grounding wire. Connect the power cord to a 3-prong AC outlet with a protective grounding terminal. 2
MODEL SUFFIX SUPPLY FREQUENCY NO. STYLE Checking the Contents of the Package Unpack the box and check the contents before operating the software. If some items are missing or otherwise inconsistent with the contents description, please contact your dealer or nearest YOKOGAWA representative. FX100 (Main Unit) Check the name plate located on the right of the instrument as you face the front panel to ensure that the model name and suffix code match the ones you ordered. MODEL SUFFIX STYLE C US 172608 N200 SUPPLY FREQUENCY NO. Model and Suffix Codes MODEL FX103 FX106 FX112 External storage medium Suffix Code -0-1 -4 Optional Code Description Number of inputs for measurement: 3ch Number of inputs for measurement: 6 ch Number of inputs for measurement: 12 ch No external memory FDD Compact flash memory card (with medium) Displayed language - 2 Options /A1 /A2 /A3 /C2 /C3 /C7 /F1 /H5 /M1 /N2 /N3 /P1 /PM1 /R1 English/German/French display Alarm output relays 2 points * 1 Alarm output relays 4 points * 1 Alarm output relays 6 points * 1 RS-232 interface (including Modbus protocol) * 2 RS-422-A/485 interface (including Modbus protocol) * 2 Ethernet (10BASE-T) interface Fail/memory end detection and output * 3 Desktop type (with power cable) * 4 Mathematical function (report fuction included) Three-terminal isolated RTD (input for measurement) Pt1000 Ω RTD input Operation under 24 VDC/AC power *5 Pulse measurement input 3 points, Remote control 5 points *6 Remote control 8 points *1 Only one can be specified at once. *2 Either one can be specified. *3 If /F1 is specified, /A3 cannot be specified. *4 /H5 When D is specified for : Power cord (UL and CSA compliant) When F is specified for : Power cord (VDE compliant) When R is specified for : Power cord (SAA compliant) When J is specified for : Power cord (BS compliant) When H is specified for : Power cord (GB compliant) *5 /P1 and /H5 cannot be specified together. *6 If /PM1 is specified, /A3, /M1, or /R1 cannot be specified. If /PM1 is specified, /A2/F1 cannot be specified. Note For information on accessories (sold separately), see page v of the user s manual, IM04L20A01-01E. 3
Handling Precautions The following describes precautions that are specific to the desktop type. For all other precautions, see section 2.1 of IM04L20A01-01E, Handling Precautions. Handling Precautions for the FX100 Desktop Type Do not apply force to the unit while it is supported by its front feet (stand). Doing so can damage the front feet. 4
Installation and Connecting the Power Supply Installation The following describes warnings that are specific to the desktop type. For all other details regarding installation, see section 2.2 of IM04L20A01-01E, Installation. Precautions Regarding the Installation Location The desktop type is not equipped to be installed in an instrumentation panel. For the desktop type, we recommend that you maintain a 50 mm or greater margin of space around the front, back, sides, and top of the instrument. This instrument is for indoor use only. Do not use the instrument outdoors. Connecting the Power Supply Points to Note When Connecting the Power Supply Please heed the following warnings when connecting the power supply to the instrument. Failure to heed the following warnings may result in electric shock or damage to instruments. WARNING Ensure that the source voltage matches the rated power supply voltage of the instrument before connecting the power cord. Check that the power switch to the instrument is turned OFF before connecting the power cord. Make sure to connect protective earth grounding to prevent electric shock. Connect the power cord of the desktop type to a three-prong power outlet equipped with a protective earth terminal. Do not use an extension cord that does not have a protective grounding wire. The protective features of the instrument will be rendered ineffective. Use a power supply that meets the conditions indicated below. Item Condition Rated supply voltage: 100 to 240 VAC Supply voltage range used: 90 to 132, 180 to 264 VAC Rated supply voltage frequency: 50/60 Hz Permitted supply voltage frequency range: 50/60 Hz ±2% Maximum power consumption: 25 VA (100 V), 35 VA (240 V) Note Do not use a supply voltage in the range 132 to 180 VAC, as this may have adverse effects on the measurement accuracy. 5
Installation and Connecting the Power Supply Connections 1. Check that the power switch to the instrument is turned OFF. 2. Connect the plug on the accessory power cord to the power supply connector on the rear panel. 3. Ensure that the power outlet to be used meets the conditions on the previous page and that the voltage of the power supply is within the maximum voltage rating of the power cord, then connect the other end of the power cord to the power supply outlet. Use a 3-prong power outlet equipped with protective grounding. The AC outlet must be of a three-prong type with a protective earth ground terminal. 6
Names of Parts The following describes only the names of parts that are specific to the desktop type. For all other part names, see section 3.1 of IM04L20A01-01E, Names of Parts and Functions. 1 STYLE MODEL SUFFIX SUPPLY FREQUENCY NO. 2 1. Handle 2. Feet (4) and stand (2) Rear Panel 4 3 5 3. Power terminal (attach the specified power cord) 4. Power switch 5. Functional ground terminal 7
MODEL SUFFIX SUPPLY FREQUENCY NO. STYLE Specifications and Dimensional Drawings Specifications The following describes specifications that are specific to the desktop type. For other specifications, see chapter 12 of IM04L20A01-01E, Specifications. Desktop Type (/H5 ) Carrying handle The in /H5 designates the power cord specification. D: Power cord (UL and CSA compliant) F: Power cord (VDE compliant) R: Power cord (SAA compliant) J: Power cord (BS compliant) H: Power cord (GB compliant) Dimensional Drawings 139 Rear View 144 24 175 52 START STOP USER FUNC ESC MENU DISP/ ENTER 15 144 39 C US 172608 N200 15 143 40 8