InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

Similar documents
Close-coupled cooling

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

APC APPLICATION NOTE #146

Power and Cooling for Ultra-High Density Racks and Blade Servers

Precision Cooling. Precision Cooling Advantages

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

APC APPLICATION NOTE #114

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Virtualization and consolidation

Switch to Perfection

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Power & Cooling Considerations for Virtualized Environments

Close Coupled Cooling for Datacentres

APC by Schneider Electric Elite Data Centre Partner

Rittal Cooling Solutions A. Tropp

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

84 kw, Tier 3, Direct Expansion, 937 ft 2

Precision Cooling Mission Critical Air Handling Units

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Rack cooling solutions for high density racks management, from 10 to 75 kw

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

IT Air Conditioning Units

Thermal management. Thermal management

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

ENCLOSURE HEAT DISSIPATION

Reducing Data Center Cooling Costs through Airflow Containment

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

APC APPLICATION NOTE #126

Industry leading low energy evaporative fresh air cooling.

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Next Generation Cooling

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

Symmetra PX. Symmetra PX 48kW Scalable from 16kW to 48kW. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Polar PDUs POWER MANAGEMENT

Liebert DCW CATALOGUE

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

HP Modular Cooling System: water cooling technology for high-density server installations

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

One Stop Cooling Solution. Ben Tam Business Development Manager

How to Increase Data Center Efficiency

HIGH DENSITY RACK COOLING CHOICES

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

MSYS 4480 AC Systems Winter 2015

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Air-Side Economizer Cycles Applied to the Rejection of Data Center Heat

Efficiency of Data Center cooling

SIFMA Technology Management Conference. Data Center Efficiency

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Data Center Trends: How the Customer Drives Industry Advances and Design Development

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Reducing Energy Consumption with

Total Modular Data Centre Solutions

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

200 kw, Tier 3, Chilled Water, 5250 ft 2

Ecoflair Air Economizers

QuickSpecs. HP Modular Cooling System. Overview

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Data Center Design: Power, Cooling & Management

Green IT and Green DC

Recapture Capacity for Existing. and Airflow Optimization

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering

EDGE LM XLMA Series Data Module

Data Center Design: Power, Cooling & Management

SmoothAir Modular Precision Cooling

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Server Room & Data Centre Energy Efficiency. Technology Paper 003

The Energy. David L. Moss Dell Data Center Infrastructure

ACFD12-T ACFD12-B. Technical Data

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Scalable, Secure. Jason Rylands

Modbus Register Map: InRow ACRD60x / ACRC60x

TECHNICAL SPECIFICATIONS

Reclaim Wasted Cooling Capacity Now Updated with CFD Models to Support ASHRAE Case Study Data

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Deploying High-Density Zones in a Low-Density Data Center

Data Center Energy Savings By the numbers

Liquid Cooling Package LCP Cooling Systems

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Transcription:

InRow Chilled Water Close-coupled, chilled water cooling for medium to large data centers Up to 0kW > Row-Based Cooling The InRow Chilled Water product design closely couples the cooling with the IT heat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. IT operators looking to improve efficiency or deploy higher density equipment will benefit from the modular design of the InRow Chilled Water products. The intelligent controls of the InRow Chilled Water products actively adjust fan speed and water flow to match the IT heat load to maximize efficiency and address the dynamic demands of today's IT environments. InRow RC, 300mm To meet the diverse requirements of IT environments, the InRow Chilled water products are available in two sizes. The InRow RC is available in 300 and 00 mm wide cabinets. The InRow RP is available in 00 mm wide only and includes humidifiers and reheat for humidity control. InRow RC, 00mm InRow RP, 00mm

Features/Benefits Availability > Active Response Controls monitor and actively adjust cooling capacity to ensure proper server inlet temperatures. > Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. Total Cost of Ownership >Close Coupled Cooling improves operational efficiency 30%- 0% over traditional data center cooling approaches. > Variable speed fans reduce energy consumption during offpeak cooling periods and adapt to unpredictable power densities. Flexibility >Adapts to work in both new and existing data center environments. > Serviceability > Modular Components simplify replacement and reduce mean time to repair >Allows system to remain operational if a fan replacement is required (300mm only). > Row based equipment allows for all serviceable components to be replaced/maintained in the hot or cold aisles. > Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream. Manageability > Real time display of current and available cooling. > InfrastruXure Central compatible > Microprocessor controller 4 line, eighty character, alphanumeric display > Building management system integration

InRow RC Chilled water cooling for medium to large data centers. Up to 30kW Variable speed, hotswappable fans reduce energy consumption during off-peak hours and allow system to remain operational if a replacement is required. 3 4 3 Intelligent control offer network manageability, real time capacity monitoring, predictive failure notification, and rack inlet temperature control. Top or bottom piping / power connections. 4 Dual A-B power inputs offers redundancy and protection Remote probe guarantees inlet temperature to IT equipment. Condensate management factory installed pump removes water from the unit, ensuring continuous operation. Casters allow for easy movement

Performance Specifications Net Cooling Capacity Return Air Temperature SKU Total Capacity Sensible Capacity 80ºF DB,.8ºF WB (.ºC DB,.ºC WB) ACRC00 3. (4,000) 3. (4,000) ACRC03 3. (4,000) 3. (4,000) 8ºF DB, 4.ºF WB (9.4ºC DB, 8.ºC WB) ACRC00 8. (,000) 8. (,000) ACRC03 8. (,000) 8. (,000) 90ºF DB,.ºF WB (3.ºC DB, 8.9ºC WB) ACRC00. (4,000). (4,000) ACRC03. (4,000). (4,000) 9ºF DB,.ºF WB (3.0ºC DB, 9.8ºC WB) ACRC00. (8,000). (8,000) ACRC03. (8,000). (8,000) 00ºF DB, 9.ºF WB (3.8ºC DB, 0.ºC WB) ACRC00 8. (98,000) 8. (98,000) ACRC03 8. (98,000) 8. (98,000) 0ºF DB, 0.8ºF WB (40.ºC DB,.ºC WB) ACRC00 30. (0,000) 30. (0,000) ACRC03 30. (0,000) 30. (0,000) Note: All values are accurate to +/- 0.3 kw (00 BTU/hr) and based on full speed with standard filters Note: All values in table are based on 4 F ( C) entering water temperature with a 0 F (. C) chilled water delta temperature.. Chilled water delta temperature is F (. C)

InRow RC and RP 00mm Chilled water cooling for medium to large data centers. Up to 0kW Variable speed fans reduce energy consumption during off-peak hours Intelligent control offer network manageability, real time capacity monitoring, predictive failure notification, and rack inlet temperature control. 3 4 3 Electric reheat controls temperature during dehumidification (RP only) 4 Top or bottom piping / Power connections Dual A-B power inputs offers redundancy and protection (RC only) Remote probe guarantees inlet temperature to IT equipment. Humidifier maintains moisture level (RP only) 8 9 8 9 Condensate management factory installed pump removes water from the unit, ensuring continuous operation. Casters allow for easy movement

Performance Specifications Net Cooling Capacity Return Air Temperature SKU Total Capacity Sensible Capacity 80ºF DB,.8ºF WB (.ºC DB,.ºC WB) ACRC00 / ACRC00 3.9 (30,000) 3.8 (,000) ACRC0 / ACRC0 3.9 (30,000) 3.8 (,000) ACRC0 / ACRC0 3.9 (30,000) 3.8 (,000) 8ºF DB, 4.ºF WB (9.4ºC DB, 8.ºC WB) ACRC00 / ACRC00 4.0 (4,000) 43. (49,000) ACRC0 / ACRC0 4.0 (4,000) 43. (49,000) ACRC0 / ACRC0 4.0 (4,000) 43. (49,000) 90ºF DB,.ºF WB (3.ºC DB, 8.9ºC WB) ACRC00 / ACRC00.3 (9,000). (,000) ACRC0 / ACRC0.3 (9,000). (,000) ACRC0 / ACRC0.3 (9,000). (,000) 9ºF DB,.ºF WB (3.0ºC DB, 9.8ºC WB) ACRC00 / ACRC00. (9,000).0 (9,000) ACRC0 / ACRC0. (9,000).0 (9,000) ACRC0 / ACRC0. (9,000).0 (9,000) 00ºF DB, 9.ºF WB (3.8ºC DB, 0.ºC WB) 3 ACRC00 / ACRC00. (0,000).0 (08,000) ACRC0 / ACRC0. (0,000).0 (08,000) ACRC0 / ACRC0. (0,000).0 (08,000) 0ºF DB, 0.8ºF WB (40.ºC DB,.ºC WB) 3 ACRC00 / ACRC00 9. (38,000) 9. (38,000) ACRC0 / ACRC0 9. (38,000) 9. (38,000) ACRC0 / ACRC0 9. (38,000) 9. (38,000) Note: All values are accurate to +/- 0.3 kw (00 BTU/hr) and based on full speed with standard filters.values are based on 4 F ( C) entering water temperature with a F (. C) chilled water delta temperature..values are based on 4 F ( C) entering water temperature with a 4 F (. C) chilled water delta temperature. 3.Values are based on 4 F ( C) entering water temperature with a F (8.8 C) chilled water delta temperature.

Electrical Data SKU Voltage (Volts) Phase Frequency (Hz) Power (Watts) Plug ACRC00 00-0 0/0 00 NEMA L-0P ACRC03 00-40 0/0 000 IEC 309 A ACRC00 00-40 3 0/0 300 NEMA L-0P or hardwired ACRC0 40-480 3 0 3300 hardwired ACRC0 380-4 3 0/0 3000 IEC 309 A or hardwired ACRP00 00-40 3 0/0 4000 hardwired ACRP0 40-480 3 0 4000 hardwired ACRP0 380-4 3 0/0 000 hardwired