Energy efficiency management and environmental impact assessment for ICTs

Similar documents
ETSI TC ENVIRONMENTAL ENGINEERING STANDARDIZATION IN THE FIELD OF ENVIRONMENTAL SUSTAINABILITY FOR ICT

Workshop on Environmental Impact Assessment and Energy

Energy efficiency of ICTs: EU initiatives and ETSI standards for its assessment

ETSI GS OEU 006 V1.1.1 ( )

STF439 -Global KPIs for energy efficiency of deployed broadband

ITU-T L Energy efficiency metrics of a base station site

CLOSING SESSION -ETSI WORKSHOP ON ENERGY EFFICIENCY

Operational Equipment Power and Environment Standard

Framework for conducting Life Cycle Analysis (LCA) of Datacenters

ETSI GS OEU 008 V1.1.1 ( )

ITU-T Study Group 5: Environment and Climate Change

Coordination Meeting of Standardisation Activities for assessing the Environmental Impact of ICT

The ETNO CORE Energy Task Force

How Huawei s Solutions Address the Challenges of Powering ICT Network

DG CONNECT (Unit H5) Update on Data Centre Activities

ETSI GS OEU 017 V1.1.1 ( )

Telecom Italia Smart sustainable cities experiences

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Vodafone Sustainability & Innovation in emerging market

Green Data Centers A Guideline

European Framework Initiative for Energy & Envinronmental Efficiency in the ICT Sector BEFORE STARTING

ETSI GS OEU 001 V1.2.4 ( )

ITU-T Study Group 5. Environment, Climate Change and Circular Economy. Qi Shuguang Vice Chairman. ITU-T Study Group 5.

EN 50600, EU COC, EMAS AND EUROPEAN DATA CENTRE ENERGY EFFICIENCY MANAGEMENT

EUROPEAN DATA CENTRE STANDARDS

Energy COnsumption NETworks (ECONET)

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

low Energy COnsumption NETworks

Converged Power Solutions. Data center power reinvented

DATA CENTRE CODES AND STANDARDS

Smart Grid Objective 6.1 in WP2013

The EU's take on ICT for Sustainability in the context of Smart cities

Worldwide Standards and Regulations

Continual Improvement of Data Centre Energy Performance

Results of LCA on Hybrid Satellite Broadband Network and comparison with other Broadband Delivery Technologies

Sustainable green 5G powering ETSI+ITU-T workshop

low Energy COnsumption NETworks

E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n

The Greening of Services

Is PUE the best we can do? Vasiliki Georgiadou, Green IT Amsterdam DCW London, UK 2019/03/12. H2020-EE-2017-RIA-IA Grant Agreement no

CARBON FOOTPRINT MONITORING THROUGH INNOVATION

Evaluation Method and Case Studies for Environmental Impact of Wired and Wireless Network Infrastructures

GreenTouch Approach in Standards Gilbert Buty (Alcatel Lucent GreenTouch)

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application.

ICT key driver to a low carbon society

BIO-MIMÉTISME : UNE APPROCHE POUR ÉCO-CONCEVOIR DES

Agenda Day 1: 7 th October 2013

This document is a preview generated by EVS

Green IT (ICT) (Accredited by British Computer Society)

ICT sites and networks energy. standardized remote energy metering

Strategic Transport Research and Innovation Agenda - STRIA

OPERA-Net I / II OptimizingPower Efficiencyin mobile RAdio NETWorks. ETSI EE Workshop 20/06/2012 OPERA-Net project presentation 1

Green networking: lessons learned and challenges Prof. Raffaele Bolla CNIT/University of Genoa

SOFTWARE IN RADIO AND SOFTWARE DEFINED RADIOS TECHNOLOGY AND DECLARATION OF CONFORMITY

Green IT Challenges for the CIO

What s new in GaBi? 2013 release of GaBi 6.3 & Databases 13 New Product GaBi Server

ETSI documents published or circulated for vote/comment in May 2018

COMMON REGULATORY OBJECTIVES FOR GSM EQUIPMENT PART 2 SPECIFIC ASPECTS OF GSM EQUIPMENT

RF adapter plugs, dimming

Overview of ITU Activities on E-Waste Management

All rights reserved. ITS at ETSI. Presented by Luis Jorge Romero on behalf of ETSI TC ITS

ICTPSP Call Theme 2 ICT for energy efficiency and sustainability in urban areas. Dr. Manuel SANCHEZ JIMENEZ

EC Mandate: Adaptation to climate change use of standards to make key infrastructures more resilient. Ab de Buck/ Caroline van Hoek

The European Programme for Energy Efficiency in Data Centres: The Code of Conduct

Standards for Smart Grids

ITU-T K.118. Requirements for lightning protection of fibre to the distribution point equipment SERIES K: PROTECTION AGAINST INTERFERENCE

ETSI Introduction. Dr. Carmine Rizzo CISA, CISM, CISSP, ITIL, PRINCE2. ETSI Technical Officer ETSI Standardisation Projects

HVDC Innovation, XECHNO Power & Fresh HVDC

PRODUCT FEATURES AND ADVANTAGES

NGNs and Energy Efficiency

Deutsche Telekom s Smart Energy Activities. Metering Billing/CRM Europe 2012 I October 2012

Friedrich Smaxwil CEN President. CEN European Committee for Standardization

ETSI Workshop ICT Energy Efficiency and Environmental Sustainability Latest projects and upcoming developments. Chiara Venturini Director, GeSI

Life cycle assessment of an LTE base station BASED ON Primary data

CEN and CENELEC Position Paper on the draft regulation ''Cybersecurity Act''

CEF e-invoicing. Presentation to the European Multi- Stakeholder Forum on e-invoicing. DIGIT Directorate-General for Informatics.

Standby & Off-Mode Network Standby

Cybersecurity in Asia-Pacific State of play, key issues for trade and e-commerce

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ERF910. RF Repeater. Synco living

TECHNICAL ORGANIZATION

Energy Efficiency Guidelines

This document is a preview generated by EVS

5G and Beyond: Perspectives on Fixed/Mobile/Cloud/Fog Integration, Network Management and Control, and Services Deployment

Guidelines for Interface Publication Issue 3

SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Framework Document for ESO Response to EU Mandate M/462

INTERNATIONAL STANDARD

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

EN EU Standard: Data Centre Facilities and Infrastructures. What s in it for me?

ETSI STANDARD Environmental Engineering (EE); Standardization terms and trends in energy efficiency

NZQA unit standard version 2 Page 1 of 5

Cabling Infrastructure for Green Buildings. Dr. Paulo Marin, EE, MSc. Paulo Marin Consultoria Phone: (201)

Nr. Standard reference Title

Server room guide helps energy managers reduce server consumption

3 More detail and justification for the recommendations

European Data Centre Infrastructure Standards EN series. Rob Cardigan, Senior Product Manager Nexans Cabling Solutions

CPS VS UPS FOR POWERING DATA CENTERS

ITU-T L External universal power adapter solutions for portable information and communication technology devices

Power supply module, bus connection module

Transcription:

http://eustandards.in/ Energy efficiency management and environmental impact assessment for ICTs Beniamino Gorini (ETSI TC-EE chairman)

2 Contents What is required to define sustainable ICT products/networks/services ETSI standards for: environmental impact assessment measurement of energy efficiency energy management energy efficiency monitoring efficient power architecture for data centres Improving energy efficiency and using of alternative energy solutions ETSI Key Performance Indicators for energy efficiency

WHAT IS REQUIRED TO DEFINE SUSTAINABLE ICT PRODUCTS/NETWORKS/SERVICES

4 What is required to define sustainable ICT products/services/networks? Methodologies to determine the environmental impact assessment (e.g. GHG, resource consumption etc) Methods to determine the power consumption of ICTs to be used as input data for the environmental impact assessment Methodologies to monitor and manage the energy efficiency Guidelines for the realization of green installations Key Performance Indicators for products/installations

ETSI STANDARD FOR ENVIRONMENTAL IMPACT ASSESSMENT Life Cycle Assessment

6 Methods for assessing the environmental impact of ICTs TS 103 199 V1.1.1 Life Cycle Assessment of ICT equipment, ICT network and service: General definition and common requirement Published (11/2011) The purpose of this TS is to harmonize the LCA of ICT: Equipment Networks Services It includes specific requirements for LCA of ICTs in respect to: ISO 14040 Environmental management, Life cycle assessment, Principles and framework ISO 14044 Environmental management, Life cycle assessment, Requirements and guidelines International Reference Life Cycle Data System (ILCD) Handbook - General guide for Life Cycle Assessment

7 Life Cycle Assessment

8 Methods for assessing the environmental impact of ICTs: the improvement TS 103 199 was evaluated during the European Commission pilot test During the pilot test, some questions have been raised that allowed to identify the strengths and weaknesses of the ETSI LCA document TS is currently under revision for improvement and upgrade to ES Provide more guidance for recycling allocation rules Clarification on how to assess the LCA uncertainty More guidance/clarifications on Network and Service LCAs Clarify applicability of annexes when only GHG emissions are assessed This Work Item is a joint activity ITU-T SG5/WP3

ETSI STANDARDS FOR MEASUREMENT OF ENERGY EFFICIENCY Measurement methods of ICT products and networks

10 ETSI standards to determine energy efficiency These standards are used to determine the power consumption to be used in the LCA analysis Customer Premises Equipment EN 301 575 V1.1.1, 5/2012 end-user broadband equipment in the scope of EU regulation 1275/2008 Wireline Broadband Access equipment ES 203 215 V1.3.1, 10/2011 Under revision to include new technologies Wireless Broadband Access equipment TS 102 706 V1.3.1, 7/2013 Under revision to enhance test method in traffic conditions Switching and router equipment ES 203 136 V1.1.1, 05/2013 Core network equipment ES 201 554 V1.1.1, 04/2012 Equipment defined in TS 123 002 Under revision to include Radio access control nodes Transport equipment ES 203 184 V1.1.1, 03/2013 Mobile networks ES 203 228 in preparation

ETSI STANDARD FOR ENERGY MANAGEMENT

12 Green Abstraction Layer ES 203 237 Green Abstraction Layer (GAL) is a novel way for managing and monitoring energy and performance profiles of device hardware. GAL is an interface between data and control planes for exchanging data regarding the power status of a device. GAL addresses three main sets of control plane processes: Local Control Policies (LCPs), which optimize the configuration at the device level, in order to achieve the desired trade-off between energy consumption and network performance, according to the incoming traffic load. For this purpose, such processes need to know in detail the internal architecture of the device (or parts thereof), the number, the typology and the capability of energy-aware elements, as well as to have access to network performance indexes. Network Control Policies (NCPs), to autonomously control and optimize the behaviour of a network. Typical examples of this kind of processes are traffic engineering, routing and signalling algorithms/protocols (e.g. OSPF-TE/RSVP-TE) with "green" extensions. Monitoring and Operation Administration & Management (OAM), for the operator to control and optimize the trade-off between energy consumption and network performance through a network management system with "green" capabilities.

13 Green Abstraction Layer ES 203 237 EAE EAE EAE EAE DEVICE EAE Energy Aware Entity LCP Local Control Policy NCP Network Control Policy OAM Operations, Administration & Management OSPF-TE Open Shortest Path First - Traffic Engineering

ETSI STANDARDS ON ENERGY EFFICIECY MONITORING

15 Energy efficiency monitoring Series of standards published by ETSI TC-EE on Infrastructure equipment control and monitoring system interface (ES 202 336-x series) Control processes defined in these publications aims to reduce the energy consumption by optimizing settings of utilities in the TLC infrastructure (e.g. cooling systems, power systems etc.) Remote monitoring and setting reduce CO2 emissions (less on-site interventions)

16 Energy efficiency monitoring: the publications ES 202 336-x: Infrastructure equipment control and monitoring system interface series 1 General interface (V1.2.1, 07/2011) 2 DC power systems (V1.1.1, 03/2009) 3 AC-UPS power systems (V1.1.1, 10/2009) 4 AC distribution power system (V1.1.1, 03/2013) 5 AC-diesel backup generators (V1.1.1, 04/2010) 6 Air conditioning systems (V1.1.1, 09/2012) 7 Other utilities (V1.1.1, 12/2009) 8 Remote power feeding (V1.1.1, 09/2009) 9 Alternative power systems (V1.1.1, 09/2012) 10 AC inverter power system control (V1.1.1, 09/2011) 11 Battery systems (in preparation) 12 Telecommunication equipment (in preparation)

17 Energy efficiency monitoring; ICT equipment pres 202 336-12 (DES/EE-02037-12) on Monitoring and Control Interface for Telecom/ICT equipment Power, Energy and Environmental parameters It defines the control/monitoring interface of telecommunication/ict equipment to keep under control the power consumption and environmental values Parameters to be monitored are: power consumption environmental parameters (e.g. temperature) Traffic/data parameters (throughput, number of connected lines, radio setting, etc)

ETSI STANDARDS ON EFFICIENT POWER ARCHITECTURE FOR DATA CENTRES

19 PDU PDU The classical power architectures Data centers with telecom equipment at 48 V-DC and data equipment at AC mains power (e.g. 380 V or 220 V AC) needs a more efficient power distribution AC mains AC/DC DC/AC AC mains AC/DC DC/DC SERVER UPS AC/DC Rectifier 48 V-DC DC/DC TELECOM AC mains AC/DC DC/DC SERVER AC mains AC/DC Rectifier DC/AC Inverter 48 V-DC DC/DC TELECOM

20 PDU No voltage conv Power architecture with better energy efficiency A power distribution at 400 V-DC has more efficiency Less conversion stages in the overall system Less losses on cables And Longer battery back-up without system de-rating No harmonic losses and effects on distribution No need for load balancing between phases Smaller footprint Suitable to supply all type of equipment in a data center without using UPS as backup 400 V-DC DC/DC SERVER AC mains AC/DC Rectifier 400 V-DC DC/DC TELECOM

21 Power architecture with better energy efficiency: the standards ETSI TC-EE has produced the standards for the power supply interface requirements of equipment to be connected to a 400 V-DC power distribution: EN 300 132-3-1, V2.1.1 (02-2012): Direct current source up to 400 V EN 301 605 V1.1.1 Earthing and bonding of 400 V-DC data and telecom (ICT) equipment

ETSI GUIDELINES TO IMPROVE ENERGY EFFICIENCY AND USE OF ALTERNATIVE ENERGY SOURCES

23 GUIDELINES FOR IMPROVEMENT OF ENERGY EFFICIENCY AND ALTERNATIVE ENERGY SOURCES TR 102 530 V 1.2.1 (07/2011): The reduction of energy consumption in telecommunications equipment and related infrastructure TR 102 532 V 1.2.1 (11/2012): The use of alternative energy sources in telecommunication installations It includes an overview of the alternative energy sources and guidelines for its use (both for powering and cooling) Disposal of waste materials LCA analysis related to alternative energy solutions (e.g. batteries) DTR/EE-02042 (in progress): Safety Extra Low Voltage DC power supply network for customer ICT devices with renewable energy and energy storage options Improved efficiency with less conversion stages Reduction of CO2 emissions using renewable energy options

ETSI KEY PERFORMANCE INDICATORS FOR ENERGY EFFICIENCY

25 Key Performance Indicators for ICT products/network/installations KPI for energy consumption This is the total consumption of energy by an operational infrastructures. KPI task efficiency = energy/service unit The indicator for task efficiency is the assessment of the work done (as a result of design and/or operational procedures) for a given amount of energy consumed. KPI heat reuse= reused energy / consumed energy This parameter addresses the energy re-use in terms of transfer or conversion of energy (typically in the form of heat) produced by the operational infrastructure to perform other work.

26 Key Performance Indicators for ICT products/network/installations KPI renewable energy= renewable / consumed energy This addresses the renewable energy produced from dedicated generation systems using resources that are naturally replenished. KPI Global Indicator This KPI allows benchmarking the energy management of ICT nodes (data centres included) depending on their size in terms of energy consumption. KPIs are defined in the ETSI standards ES 205 200 series produced by TC-ATTM

THANK YOU!