Channel Master SDI-12 Setup

Similar documents
WinH-ADCP User s Guide

WinRiver Quick Start Guide

Sample 3D velocity at up to 200 Hz for use in hydraulic models and laboratory flumes

High-performance mean currents and turbulence, wave height and direction

Rowe Technology, Inc. Pulse Wave User Guide

Sample 3D velocity at up to 64 Hz for small-scale research in coastal areas

> 1000 m current profiling range for stand-alone and online applications

Argonaut-ADV Operation Manual Firmware Version 11.2

2D Horizontal Profiler khz

Workhorse ADCP Multi- Directional Wave Gauge Primer

H-ADFM Velocity Profiler. Operation, Maintenance, & Software Manual

Aquadopp Profiler 1 MHz

CAMPBELL BASED MULTI-CHANNEL DATA LOGGER LITE USER MANUAL

Vibrating Wire Instrument Assembly Guide

RST INSTRUMENTS LTD.

AquaTroll 600 Configuration and MultiLogger Integration

Campbell Based Multi-Channel Data Logger. User Manual. Man /08/2014 Final David Farnham. Chris Rasmussen. Chris Rasmussen. Manual No.

SR50 Sonic Ranging Sensor

COMMONWEALTH OF PENNSYLVANIA SPECIFICATION

WavesMon v3.08 User s Guide

Using the Hotwire Anemometer

Integrating the Measurand Shape Accelerometer Arrays (SAA) Sensor Application Note #19

The Argonaut-XR System and the Multi-Cell Feature

Campbell Based Multi-Channel Data Logger Lite. User Manual. Man158a /05/2015 Final Ben Scott James Kwist Philip Day. Manual No.

UndErwatEr acoustic modems. product information GUidE

( 83P UDP/IP Ethernet Datagram,.83P File Format )

RST INSTRUMENTS LTD.

;=========================>>> NOTICE <<<============================

NAVIPAC 4 INTRODUCTION AND WORKFLOW

Probe Reader/ Calibration Programming Unit, PIU- 1 (#30010)

LoggerNet 4 Series Datalogger Support Software

Configuring the LI-1400 Datalogger for Illuminance and Irradiance Studies

SonTek/YSI Triton Software Manual

1.1.1 Orientation Coordinate Systems

elocity SOFTWARE USER S GUIDE P/N 95D (January 2017) 2017 Teledyne RD Instruments, Inc. All rights reserved.

Single-point current meter designed for very long-term deployments

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

Ultrasonic Heat Flow Meters

FT2 View Instruction Manual

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

Mini Environmental Quality Meter

The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

BROADBAND SERIES. Signature1000/500 A HIGH PERFORMANCE SCIENTIFIC POWERHOUSE TRUE INNOVATION MAKES A DIFFERENCE

RST INSTRUMENTS LTD.

Gill Instruments WindSonic Two Dimensional Sonic Anemometer Revision: 3/07

How to Integrate Digiquartz Intelligent Products with Campbell Scientific CR1000 Series Data Loggers

DS-2 Sonic Anemometer

CAMPBELL SCIENTIFIC S SHORT CUT: CREATE CR10(X), 21X, CR500, AND METDATA1 PROGRAMS IN MINUTES

AccuTrac Multi-Point Data Acquisition Software User Guide

WinADCP User s Guide. P/N (November 2001) RD Instruments Acoustic Doppler Solutions

DYNAMIC POSITIONING CONFERENCE September 16-17, Sensors

TD 311 USER MANUAL DataStudio 3D April DATASTUDIO 3D Post-processing software

UNDERWATER ACOUSTIC MODEMS PRODUCT INFORMATION GUIDE

SENTINEL V OPERATION MANUAL. P/N 95D (April 2014) 2014 Teledyne RD Instruments, Inc. All rights reserved.

Re: ENSC 440 Functional Specifications for a Posture Measurement and Data Logging System

MODEL.6715 DATA ACQUISITION SOFTWARE INSTRUCTION MANUAL

RDI Tools User s Guide

Series DMHF Heat Meter

Online. COM220 Phone Modem. Last Training Course for 2008 DOWNLOAD THE LATEST O/S & SOFTWARE UPDATES. I s s u e 2 2 A u g / O c t

Revision: 10/26/2018 Copyright Campbell Scientific

RIVA / Athena Pro-Series ECU

Digital Probe Calibration Programmer (#30010)

A YSI Environmental Company. SonTek/YSI ADVField/Hydra Acoustic Doppler Velocimeter (Field) Technical Documentation

Datalogging Conductivity/ TDS Meter. Instruction Manual

Wide measurement range Temperature operating range is 10 to 65ºC (15 to 150ºF); RH range is 0 to 99% non-condensing.

Data acquisition hardware

Getting Started. onset computer corporation. Software for HOBO Data Loggers & Devices

and Ethernet Gateway Quick Start Guide

VmDas User's Guide. P/N 95A (August 2000)

VAN WALT Monitoring your needs

1) Microcom GTX User s Manual 2) Microcom GTX GUI Software 3) Campbel Scientific CR1000 User s Manual 4) Campbell Scientific LoggerNet Software

Instrument Toolkit Instructional Manual

STANDARD OPERATING PROCEDURES SOP : 1736 PAGE: 1 of 35 REV: 0.0 DATE: 09/25/06 MEASUREMENT OF AIR CHANGES USING THE WOLFSENSE IAQ PROBE

WorkHorse Monitor / Sentinel User s Guide

S. D. Pierce J. A. Barth. College of Oceanic and Atmospheric Sciences Oregon State University Corvallis, Oregon

INS aided subsurface positioning for ROV surveys

USING THE CR10KD KEYPAD TO TROUBLESHOOT AND/OR RESET THE CAMPBELL SCIENTIFIC RAIN BIRD WEATHER STATION BART NEF CSI 27.SEPTEMBER.

VitalView Activity & Data Viewer User Manual. Version 1.3. For Technical Assistance please contact STARR Life Sciences at

Remote sensing In situ T, S and tracers Velocity Observing systems. Course url: Talley SIO 210 (2013)

Technical Note: Interfacing a C-sense pco 2 Sensor to a Campbell Scientific CR1000 Datalogger

Logger Pro 3 Release Notes

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

Clamp-On Transit Time Ultrasonic Flow Meters

Orifice Flow Meter

Quick Start Guide. RainWise CC-2000 Edition. Visit our Website to Register Your Copy (weatherview32.com)

CR510 DATALOGGER OPERATOR'S MANUAL

Water Distribution System Wireless Monitoring Solutions

DATA ACQUISITION Hints and Tips

Using the VWDSP Interface Application Note #11

Level Measurement Products Ultrasonic Level Products

The SolarTrak Prospector. CR-1000 Datalogger

DICKSON. WiZARD2 Manual. Rev:

DOWNLOADING NEW OPERATING SYSTEM TO A CR500, CR10X, OR CR23X

User Manual. Data Logging Anemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

Micro Accelerometer, Temperature and Depth datalogger for tracking free-moving animals

User's Guide. Cup Thermo-Anemometer. Model AN400

Integration of ShapeAccelArray and Campbell Scientific CR800/CR1000 Data Loggers

Datalogging Hot Wire CFM Anemometer

AQUALAND GRAPH Nx INSTRUCTION MANUAL

Transcription:

RD Instruments Acoustic Doppler Current Profilers Application Note FSA-020 (September 2004) Channel Master SDI-12 Setup 1 Introduction This application note will help the user to log temperature, pressure, vertical beam range to surface, and up to 9 cells of X & Y component velocity data from a Channel Master using a Campbell Scientific CR10X data-logger. Equipment Required: Channel Master Horizontal ADCP with SDI-12 communications option, WinH-ADCP Version 3.xx Campbell Scientific CR10X with serial interface module and LoggerNet software Computer running Windows 2000 or Windows XP, two serial ports preferred 12V DC power for the Channel Master and CR10X Suitable site for testing/deployment 2 Setup the Channel Master Connect the Channel Master to the computer, power, and the CR10X. Refer to the Campbell Scientific CR10X data-logger documentation and the Channel Master Operation Manual for detailed instructions. Figure 1. Channel Master Connected to Port 8 on the CR10X FSA-020 (September 2004) Page 1 of 10

Channel Master SDI-12 Setup 2.1 Configure the Channel Master Use the following steps to verify that the Channel Master is setup correctly. a. Start WinH-ADCP. On the Start Wizard, click Mount ADCP. b. Check the Channel Master s pitch and roll. Set them both as close to zero as possible. For more information on Mount ADCP, see the WinH-ADCP User s Guide. Figure 2. WinH-ADCP Start Wizard c. On the Configure menu, click Setup Wizard and select Real-Time Data Acquisition. For more information on collecting real-time data, see the WinH-ADCP User s Guide. d. Set the number of cells to 1 to 9 (standard SDI-12 supports only up to nine cells). e. Set the sample interval to 10 seconds. Page 2 of 10 RD Instruments

RD Instruments Acoustic Doppler Current Profilers Application Note FSA-020 (September 2004) Figure 3. HADCP Setup Screen f. Click the Advanced Commands button in the lower right corner. Add the TP00:00.20 command to the Additional Commands box to set the ping time to the minimum recommended value. This helps to conserve power. Figure 4. Advanced Commands Screen FSA-020 (September 2004) Page 3 of 10

Channel Master SDI-12 Setup g. Collect real-time data to verify that the Channel Master is taking good data. Record typical values of temp, pressure, vertical beam range, and velocities. Figure 5. Collecting Real-Time Data with WinH-ADCP 3 Setup the Channel Master for SDI-12 On the Configure menu, click Setup Wizard and select SDI-12 Setup. On the SDI-12 Configuration screen, set the number of cells, cell size, HADCP address, units, then deploy. Figure 6. SDI-12 Configuration Screen Page 4 of 10 RD Instruments

RD Instruments Acoustic Doppler Current Profilers Application Note FSA-020 (September 2004) 3.1 Check the SDI-12 Communication through the CR10X a. Run LoggerNet and setup communications to the CR10X. Figure 7. LoggerNet Software b. Connect to the CR10X. c. Start the terminal mode by using the menu and selecting Test, Terminal Emulator. d. Enter 8X at the * prompt to go to directly to the SDI-12 communications. e. Send commands to the Channel Master and view the results. am! tells Channel Master to take data (the a denotes the address that you set for the Channel Master in the SDI-12 deployment screen in WinHADCP). The response a0094 indicates that in nine seconds, the Channel Master will have four values ready to send. They are (in order): Temperature (Centigrade of Fahrenheit) Depth (Meters or feet) Reserved for now (always 100.000), and Corrected depth - range to surface (Meters or Feet) NOTE. The CJ command is used to select metric or English units. ad0! Reads sensor data from Channel Master. am1! Tells Channel Master to ready x-component velocity data The response a0019 indicates that in one second, the Channel Master will have nine values ready to send. Since the Channel Master has already done the velocity measurement after the am! command was sent, only a one second delay is necessary to allow the Channel Master to format the velocity data for output. FSA-020 (September 2004) Page 5 of 10

Channel Master SDI-12 Setup ad0! Reads out the first few cells ad1! Reads out the remaining cells ad2! May be required to read the last cells if the data strings are too long for ad0! and ad1! to get all of the available data am2! Tells Channel Master to ready Y-component velocity data ad0! Reads out first few cells ad1! Reads out remaining cells ad2! May be required to read the last cells if strings too long for ad0! and ad1! to get them all A screen capture of a manually executed measurement is shown in the figure below with the Channel Master address set to 1. Figure 8. LoggerNet Terminal Mode The amount of data returned is dependent on the number of bins selected with the user interface command (WNxx command). Page 6 of 10 RD Instruments

RD Instruments Acoustic Doppler Current Profilers Application Note FSA-020 (September 2004) 3.2 Setup the CR10X to Log Data Run Edlog in LoggerNet. Set up a data table for use when writing a program for the CR10X. A data table for use with a program listing below is shown in the next figure. Figure 9. LoggerNet Data Table 3.3 Example Program to Log Data Below is a sample program for the CR10X to acquire the CR10X internal temperature, acquire Channel Master data for nine cells, and output the day and time, logger temperature, and the Channel Master sensor, and the first nine cells of x-velocities and y-velocities to final storage. ;{CR10X} ;Simple program to acquire SDI-12 data from ;an RD Instruments Channel Master ;Channel Master is setup for SDI-12 address 1 ;Channel Master connected to port 8 ;also get internal temp from logger ;set execution interval *Table 1 Program 01: 60 Execution Interval (seconds) ;get internal CR10X temperature FSA-020 (September 2004) Page 7 of 10

Channel Master SDI-12 Setup 1: Internal Temperature (P17) 1: 1 Loc [ TempInt_1 ] ;send 1M! to start Channel Master ;this will get back 4 sensor values ;temp, pressure, undefined, vertical beam range 2: SDI-12 Recorder (P105) 1: 1 SDI-12 Address 2: 0 Start Measurement (am0!) ; 3: 8 Port 4: 2 Loc [ RDISens_1 ] 5: 1.0 Mult 6: 0.0 Offset ;send 1M1! to get up to 9 x-velocity components 3: SDI-12 Recorder (P105) 1: 1 SDI-12 Address 2: 1 Start Measurement (am1!) 3: 8 Port 4: 6 Loc [ RDIVx_1 ] 5: 1.0 Mult 6: 0.0 Offset ;send 1M2! to get up to 9 y-velocity components 4: SDI-12 Recorder (P105) 1: 1 SDI-12 Address 2: 2 Start Measurement (am2!) 3: 8 Port 4: 15 Loc [ RDIVy_1 ] 5: 1.0 Mult 6: 0.0 Offset ;get day and time, put in final storage ;put internal temp and Channel Master data ;in final storage as well 5: Do (P86) 1: 10 Set Output Flag High (Flag 0) 6: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 1 Array ID 7: Real Time (P77) 1: 110 Day,Hour/Minute (midnight = 0000) 8: Do (P86) 1: 10 Set Output Flag High (Flag 0) 9: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 2 Array ID 10: Sample (P70) 1: 1 Reps 2: 1 Loc [ TempInt_1 ] 11: Do (P86) 1: 10 Set Output Flag High (Flag 0) 12: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 3 Array ID Page 8 of 10 RD Instruments

RD Instruments Acoustic Doppler Current Profilers Application Note FSA-020 (September 2004) 13: Sample (P70) 1: 4 Reps 2: 2 Loc [ RDISens_1 ] 14: Do (P86) 1: 10 Set Output Flag High (Flag 0) 15: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 4 Array ID 16: Sample (P70) 1: 9 Reps 2: 6 Loc [ RDIVx_1 ] 17: Do (P86) 1: 10 Set Output Flag High (Flag 0) 18: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 5 Array ID 19: Sample (P70) 1: 9 Reps 2: 15 Loc [ RDIVy_1 ] *Table 2 Program 02: 0.0000 Execution Interval (seconds) *Table 3 Subroutines End Program a. Download the program to the CR10X b. Using LoggerNet, download the program into the CR10X. Execution should begin immediately. c. View the data coming in to the CR10X d. In LoggerNet from the Connect window you may set up a numeric view to observe data as it is being acquired from the Channel Master or other devices attached to the CR10X. e. Watch data as it is being acquired to be sure that the correct data is being logged into the correct locations in the data table. f. Download and view the data from the CR10X g. Use LoggerNet to recover the data recorded in the CR10X. For the program listing above, if the data is recovered in comma-separated format, using Viewer in LoggerNet, the data should be formatted like the data shown in the next figure. FSA-020 (September 2004) Page 9 of 10

Channel Master SDI-12 Setup Figure 10. Viewing Channel Master Data with LoggerNet Page 10 of 10 RD Instruments