Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005

Similar documents
Data Sheet and Installation

Miniature Asynchronous Modems

INSTALLATION and OPERATION MANUAL

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

DeviceMaster RTS 16-Port Hardware Installation

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

Installation and Operation Manual. TinyBridge-100. Miniature Remote Fast Ethernet Bridge

xdsl Bridge WireSpan 5100B Installation Guide ATRIE TECHNOLOGY INC. (Version 1.00)

RocketPort Plus Hardware Installation

-C5RS-LC RS232 EXTENDER

RS-232 Connector Pin Assignments

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

Stride Industrial Ethernet Switches

Select a Data Communication Interface

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

LFX2-MA Fast Ethernet Extender. Installation Guide

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

LLM-336S.Eth. Introduction. Features. Industrial Leased line modem with internal Ethernet Bridge.

Connector and Cable Specifications

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

FSW-1609TFX FSW-2409TFX

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

ADA User Manual ADA Separator - Repeater RS-232. io_ada-1010_v3.20_en. Copyright CEL-MAR sp.j.

High performance access device

Cable Pinouts. SRP I/O Module

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Chapter 4: Network Access. Introduction to Networks v5.1

Bridge Module. Installation Guide and Users Reference Manual

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

GT- IRDM-9603 Product description Rev. 2 17/06/2014

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

LevelOne FSW PoE Fast Ethernet Switch User Manual

XC300 VDSL Network Extender Owners Manual

InterChangeVS 1000 Series VS1000 and VS1100 Hardware

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

User Manual A08. User Manual

Connector and Cable Specifications

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

MDI/MDIX) FEP-32005T-2

PTC-101-M12 Hardware Installation Guide

TE100-S16 16-Port 10/100Mbps Fast Ethernet Switch. User s Guide

KFC-200. Installation Guide

E1/10&100Base-T Bridge (VLAN)

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m

FHU-0505TXDS FHU-0805TXDS FHU-1605TXDS

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

ADA User manual ADA RS-232 to Multidrop Fiber Optic Converter. 1 io_ada-7210_en_v3.17. Copyright CEL-MAR sp.j.

TRP-C41 User s Manual

RS 232 to Fibre Optic Modems ELO E240, ELO E241, ELO E242. Operation manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

SeaLINK+8/USB. Sealevel Systems, Inc 155 Technology Place P.O. Box 830 Liberty, SC USA

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

SeaLINK+232I USER MANUALM

FSW-1610TX FSW-2410TX

Industrial Ethernet Switch

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

PCI Hardware Installation

Miniature Asynchronous 4-Wire High Speed Modems

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

HEC. General Operating, Maintenance and Installation Manual

Bridge: The 702-W will operate in Layer 2 without network segmentation. Router: The 702-W offers Layer 3 routing to allow network segmentation.

FieldServer X-25 Start-Up Guide

Industrial Media Converters

10/100Base-TX Industrial Ethernet Extender

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Contents. One Introduction 2. Two Installation 3 Front Panel 10base-T Ports 10/100base-TX Ports LEDs

General Operating, Maintenance and Installation Manual

FCC Certifications. CE Mark Warning

Industrial 3-Port Fast Ethernet Media Converter Switches

Perle SMI Media Converter Installation Guide

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Appendix A Cable Pinouts

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

2 Mesa Ethernet Dock User s Manual

An ISO-9001 Certified Company

Channel Switch CS. General Operating, Maintenance and Installation Manual

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

Serial Communication Prof. James L. Frankel Harvard University. Version of 2:30 PM 6-Oct-2015 Copyright 2015 James L. Frankel. All rights reserved.

SINAUT ST7 Dedicated Line Modem MD2

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

RS-232/RS-422 Optical Isolator

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Transcription:

Installation and Operation Manual SIMREX Corporation ubridge Ethernet Interface for SIMREX Radio Modems SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005 SIMREX CORPORATION Your Trusted Wireless Solution Provider

IMPORTANT The ubridge is powered by an external power supply. To reduce the risk of electrical shock, fire and injury to persons: Use only with a UL-listed and CSA Certified Class 2 power supply rated for 12 VDC, 400 ma or more. Declaration of Conformity SIMREX Corporation declares that the ubridge conforms to the following standard(s) or other normative document(s): EMC: EN 55022 (1994): Limits and methods of measurement of radio disturbance characteristics of information technology equipment. EN 50082-1 (1992): Electromagnetic compatibility. Generic immunity standard for residential, commercial and light industry. Supplementary Information: This product herewith complies with the requirements of the EMC Directive 89/336/EEC. The product was tested in a typical configuration.

INSTALLATION 1. Switch Settings Set switches according to Table 1 (factory defaults in bold) Table 1. Switch Settings Switch Name FDX FILTER COMPR ASYNC Description OFF: ON: ON: OFF: Note: ON: OFF: Note: OFF: ON: Note: Ethernet half duplex Ethernet full duplex Only frames destined for another LAN are transmitted over WAN All frames are transmitted over WAN Filter should be set to OFF for LAN extender or segmenter applications Compression is activated Compression is disabled Use only opposite with COMPR set to ON WAN link is in synchronous mode WAN link is in asynchronous mode Table 2. 4-wire Operating Ranges Speed Cable Max. Range 10 Mbps Cat. 3 UTP: 400m 10 Mbps Screened UTP (Cat. 3) 500m 10 Mbps Level 5 UTP 500m 10 Mbps IBM Type 1 750m 5 Mbps Cat. 3 UTP: 600m 5 Mbps Screened UTP (Cat. 3) 700m 5 Mbps Level 5 UTP 700m 5 Mbps IBM Type 1 1300m 5 Mbps Telephone Cable Nominally 150m

2. Power For 10BaseT configuration, plug in the external power adapter. The PWR LED will light up. Note: While the ubridge can operate with any regulated 12 VDC, 400mA power supply, the CE approval on fiber optic and 4-wire versions requires use of the power supply listed in Ordering. 3. LAN Interface For 10BaseT configuration, either a straight or a cross-cable may be required. Use a cross-cable when connecting to a port that does not implement the crossover function internally. Otherwise, use a straight cable. Hubs, usually implement the crossover function internally, while NICs and other devices do not. 4. WAN Interface ubridge operates in DTE mode on the WAN interface and receives an internal clock. Connect the 25-pin female connector of the unit to DCE equipment, using the supplied adapter cables (See Table 5 for pin out details and Figure 2 for the DB-25 port). For asynchronous mode, an internal baud rate generator can be used to generate seven standard frequencies. An external clock can be connected to pins 15 and 12 for operation at other frequencies. The internal Baud Rate Generator and ACCM are configured by tying the appropriate pins on the connector to ground (pin 7), as shown in Table 3. If required, an external clock (operating at 16 times the required baud rate) should be connected to pin 15 of the DB-25 connector. The default setting is 9.6k with ACCM enabled.

Figure 2. DB-25 Port OPERATION ubridge operation is automatic. Table 4 shows how to diagnose the status of the ubridge from the LED indicators. Compression The dipswitch COMPR enables and disables Enhanced ugram compression. This form of compression can increase data throughput depending on the type of traffic. Valid Ethernet frames have a minimum length of 64 bytes. Frames shorter the 64 bytes are padded. With compression enabled, these padding bytes are stripped off before being transmitted over the WAN, and repadded while being received on the other side. The example below shows the difference between a padded Ethernet frame before and after compression.

Before compression: DA SA Type DATA PADDING Bytes: 6 6 2 20 26 After compression: DA SA Type DATA Bytes: 6 6 2 20 Compression should be enabled on both ubridges for proper operation. Table 3. Setting Asynchronous Parameters BAUD RATE External Clock (16X required baud rate) BAUD2 (PIN 6) BAUD1 (PIN 8) BAUD0 (PIN 17) ground ground ground 115.2k ground ground 57.6k ground ground 38.4k ground 28.8k ground ground 19.2k ground 14.4k ground 9.6k ACCM enabled ACCM disabled ACCM (PIN 22) ground Table 4. LED Indicators LED Color Description WAN Yellow Activity on WAN LAN Yellow Activity on LAN Green Link integrity pass COLL Red Collision on LAN PWR Green Power supply ON

Table 5. DB-25 Connection V.24/RS-232 Pin Name Type 1 Shield 2 TxD Output 3 RxD Input 4 RTS Output 5 CTS Input 6 BAUD2 Input 7 GND 8 BAUD1 Input 9 NC 10 NC 11 NC 12 NC 13 NC 14 NC 15 TCLK/EXCLK Input 16 NC 17 RCLK/BAUD0 Input 18 NC 19 NC 20 NC 21 NC 22 ACCM Input 23 NC 24 NC 25 NC

SPECIFICATIONS BRIDGE LAN WAN LAN Table 10,000 MAC addresses with five-minute automatic aging Filtering and Forwarding 15,000 frames per second Buffer 256 frames Delay 1 frame Standard Conforms to IEEE802.3 / Ethernet Data Rate 10 Mbps (20 Mbps 10BaseT in full duplex topology) Connectors 10BaseT (UTP): Shielded RJ-45 Protocol HDLC Data Rate Up to 10 Mbps synchronous Up to 115.2kbps asynchronous Internal Baud Rate Generator Standard bit rates (in kbps): 9.6, 14.4, 19.2, 28.8, 28.4, 57.6, 115.2 Connectors V.24/RS-232 with female DB-25 GENERAL Physical Length: 69 mm / 2.7 in Width: 53 mm / 2.1 in Height: 18 mm / 0.7 in Weight: 30 g / 1.0 oz Power 12 VDC / 0.4A regulated Current Consumption 0.2A @ 12 VDC Environment Temperature: 0-50C (32-122F) Humidity: Up to 90%, non-condensing

IN CASE OF DIFFICULTY... SIMREX Corporation products are designed for long life and trouble-free operation. However, this equipment, as with all electronic equipment, may have an occasional component failure. The following information will assist you in the event that servicing becomes necessary. TECHNICAL ASSISTANCE Technical assistance for SIMREX products is available from our Customer Support Team during business hours (8:00 A.M. 5:30 P.M. Eastern Time). When calling, please give the complete model number of the radio, along with a description of the trouble/symptom(s) that you are experiencing. In many cases, problems can be resolved over the telephone, without the need for returning the unit to the factory. Please use one of the following means for product assistance: Phone: 716 206-0174 FAX: 716 204-0476 E-Mail: techsupport@simrex.com Web: www.simrex.com FACTORY SERVICE Component level repair of radio equipment is not recommended in the field. Many components are installed using surface mount technology, which requires specialized training and equipment for proper servicing. For this reason, the equipment should be returned to the factory for any PC board repairs. The factory is best equipped to diagnose, repair and align your radio to its proper operating specifications. If return of the equipment is necessary, you will be issued a Return Merchandise Authorization (RMA) number. The RMA number will help expedite the repair so that the equipment can be repaired and returned to you as quickly as possible. Please be sure to include the RMA number on the outside of the shipping box, and on any correspondence relating to the repair. No equipment will be accepted for repair without an RMA number. A statement should accompany the radio describing, in detail, the trouble symptom(s), and a description of any associated equipment normally connected to the radio. It is also important to include the name and telephone number of a person in your organization who can be contacted if additional information is required. The radio must be properly packed for return to the factory. The original shipping container and packaging materials should be used whenever possible. All factory returns should be addressed to: SIMREX Corporation Service Department (RMA No. XXXX) 5490 Broadway St. Lancaster, NY 14086 USA When repairs have been completed, the equipment will be returned to you by the same shipping method used to send it to the factory. Please specify if you wish to make different shipping arrangements.

SIMREX Corporation 5490 Broadway St. Lancaster, NY 14086 Sales: +1 480-926-6069 Manufacturing: +1 716-206-0174 Web: www.simrex.com