Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Similar documents
FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

FCD-E1E Managed E1 and Fractional E1 Access Device

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

FOMi-40 Fiber Optic Modem with Remote Management

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

2/4-wire SHDSL Modem/Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-108, Optimux-106

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

IPmux-1E. TDMoIP Gateway FEATURES

Optimux-34, Optimux-25

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

FCD-155 STM-1/OC-3 Terminal Multiplexer

Optimux-34 Fiber Optic Multiplexer

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

PSEUDOWIRE PERFORMANCE

Gmux Modular TDMoIP Gateway FEATURES

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

Where to buy > Product page >

Optimux-108, Optimux-106

Optimux-1032, Optimux-1025

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

Multiservice Network Termination Unit

ASMi-54L. Data Sheet. SHDSL.bis Modem

LA-140. Advanced ATM IAD FEATURES

ASMi-54 SHDSL.bis Modem

ASMi-54L SHDSL.bis Modem

Vmux-400 GSM A-bis/A-ter Optimization Gateway

IPmux-1E TDM Pseudowire Access Gateway

4xT1/E1 i nline probe ASE With LinkSafe capabilities

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05

IPmux-16 TDM Pseudowire Access Gateway

RAD KILOMUX-2100/2104

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

ASMi-54 SHDSL.bis Modem

Vmux-110. Voice Trunking Gateway FEATURES

HS-2. MEGAPLEX-2000/2100 Module. 2-Channel High Speed Data Module DESCRIPTION FEATURES

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers

Atrie WireSpan 620. User's Manual

Vmux-2120 Voice Trunking Gateway

Vmux-210 Analog Voice Trunking Gateway

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

MARKET SEGMENTS AND APPLICATION

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

IPmux-14. TDM Pseudowire Access Gateway FEATURES

Protocol/interface converter series

GYM Bilgi Teknolojileri

Loop-O 9300 Fiber Optical Mux

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

Megaplex-2100/2104 Modular Integrated Access Multiplexers

Optimux-108, Optimux-106

Chapter 2. Hardware Description. 2.1 Chassis. Note: For product specifications, see Appendix A, Specifications.

VCL-TP, Teleprotection Equipment

16 x E1 G x Ethernet optical multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer

V C ALIANT OMMUNICATIONS. Product Brochure & Data Sheet

Loop-O9330 Fiber Optical Mux

VCL-Ethernet over E1 10/100 Base-T / E1/100Base-FX to E1 Interface Converter Product Brochure & Data Sheet

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

ETX-102 Carrier Ethernet Demarcation Device

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

Datasheet. Multi-Service Access Platform OPCOM3500E-12. OPCOM3500E-12 Feature. Raisecom Technology Co., Ltd.

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer

Vmux-110 Voice Trunking Gateway for Remote Sites

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

Gmux-2000 Hub-Site Pseudowire and Voice Trunking Gateway

RICi-16 Ethernet over Bonded PDH Network Termination Unit

Installation and Operation Manual VF-30/VF-60. Single/Dual E1 Digital Voice Compression Modules. Megaplex-2100 Version 11 MEGAPLEX-2100 MODULES

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company

4 Last Mile (Local Loop)

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005

ISO 9001:2000 Certified Company

ERM-Mux/Plus. 4U, 10 I/O Slot Data, Ethernet, Voice E1 Managed Multiplexer. E1 Access Multiplexer. ERM-Mux/Plus.

VCL-Ethernet over E1 10/100 Base-T / E1/100Base-FX to E1 Interface Converter Product Brochure & Data Sheet

ATM OVER PACKET CAPABILITIES

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

FAISCEAU HERTZIEN NUMERIQUE SAF

OPERATION MANUAL INSTALLATION AND ML-8E1, ML-8T1. 8-Port Main Link E1 and T1 Modules. Megaplex-2100/2104 Version 12. The Access Company

IPmux-2L, IPmux-4L. IPmux-2L, IPmux-4L are a TDM pseudowire. also serves as an Ethernet-based access device.

Miniature Asynchronous Modems

isap5100 STM1/E1, Data, Ethernet, Voice Managed Multiplexer (4U)

multiplexers & interface converters

E1/10&100Base-T Bridge (VLAN)

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

T3 Interface Converters

Transcription:

FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX I/O modules Fail-safe sub-e1 link ensuring uninterrupted service (G.703 only) Data interfaces: V.35, RS-530, V.36/RS-449 or X.21 Optional high performance built-in Ethernet bridge/router SNMP agent Management:! Out-of-band via V.24 supervisory port or Ethernet management port! Inband via TS 0 or dedicated timeslot Dial-in option for remote out-of-band management Dial-out for alarm report The E1 main link can be supplied with the following options:! Built-in LTU! Fiber optic interface E1 interface complies with: ITU G.703, G.704, G.706, G.732, G.823 Enhanced diagnostics include:! User activated local and remote loopbacks! Integrated BER tester! Fractional E1 in-band loop Stores 24 hours of E1 network performance monitoring and last 100 alarms Relay activation upon alarm event Alarm mask configurable for any alarm DESCRIPTION serves as a dedicated access multiplexer for business customers, providing modular integration of voice and data traffic over E1 or Fractional E1 services (see Figure 1). also operates opposite RAD's modular DXC (multiservice access node) products or other vendors' E1 equipment, for multilink star applications, such as access to SDH networks. The DXCs and operate together with centralized SNMP network management (see Figure 2). can be ordered with a regular E1 (G.703) or a fiber optic link. Both configurations are also available with an optional sub-e1 drop & insert port. The unit includes one data port or an optional Ethernet bridge/router. includes a single I/O module slot that supports one Megaplex I/O module. This provides field upgrade and service profile change capabilities that are available only on larger modular devices (for full module details and ordering information, see individual module data sheets).

BASIC UNIT The basic unit includes power supply, E1 link and one data port. The E1 interface is compatible with virtually all carrier provided E1 services and meets ITU recommendations G.703, G.704, G.706 and G.732. The E1 interface supports either 2 or 16 frames per multiframe, with or without CRC-4. Zero suppression over the line is HDB3. The integral LTU (optional) ensures a range of up to 2 km. can be ordered with a fiber optic link, which eliminates the need for an external fiber optic modem. The fiber optic link provides a secure link in hazardous or hostile environments. It complies with ITU standards G.921 and G.956. Four fiber optic interfaces are available:! 850 nm LED for use over multimode fiber at distances up to 5 km (3 miles)! 1300 nm LED for use over single mode fiber at distances up to 47 km (29 miles)! 1300 nm laser diode for use over single mode fiber at distances up to 62 km (38 miles)! 1550 nm laser diode for use over single mode fiber for extended range up to 100 km (62 miles). APPLICATIONS Timeslot assignment is programmable, allowing data from each data port and from the sub-e1 port to be placed into timeslots consecutively. also provides additional flexibility, by giving full user control over the data ports timeslot allocation without restrictions. Multiple clock source selection ensures maximum flexibility for supporting different applications. The E1 main link may be clocked from the recovered receive clock, from an internal oscillator, from one of the data ports or from the sub-e1 port. Bypassing the sub-e1 port to the main link (non-fiber optic), ensures uninterrupted service to the sub-e1 port and provides immunity to hardware and power failure. is available as a standalone unit. A rack mount adapter kit enables installation of the unit in a 19" rack. USER INTERFACE The following data port interfaces can be ordered: V.35, RS-530, V.36/RS-449 or X.21. The ports can operate in the following clock modes: DCE transmit and receive clocks are output DTE1 external transmit clock is input (coming from the user DTE) DTE2 both the transmit and receive clocks are externally input Invert data is sampled using an invert clock. The optional built-in Ethernet bridge is a high performance remote, self-learning bridge. It is ideal as a LAN extender or segmenter over E1 link applications. The LAN table stores up to 10,000 addresses and is automatically updated. Filtering and forwarding is performed at the maximum theoretical rate of 15,000 pps (wire speed) and the buffer can hold 256 frames with a throughput latency of 1 frame. Filtering can be disabled for extender or segmenter applications. The Ethernet port is available with 10BaseT (UTP) which operates in full duplex. The optional built-in Ethernet router is a high performance remote IP router. It is ideal as a LAN extender or segmenter over bit-stream type infrastructures. The router receives Ethernet frames from the LAN and forwards packets to the IP network on the Ethernet LAN or to the WAN according to their destination. The Ethernet port is available in 10BaseT (UTP) which operates in full duplex mode. The optional sub-e1 port can be configured to work without CRC-4, while the E1 main link is working with CRC-4. This enables connection of E1 equipment not supporting CRC-4, over an E1 network that is working with CRC-4. Figure 1. Connection of LAN Traffic together with PABX Traffic to E1 Network

Rear Panel Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com

MANAGEMENT & MAINTENANCE Setup, control and monitoring of status and diagnostics information can be activated via:! ASCII terminal connected to the async control port command line interpreter! SNMP management connected to the async control port. has an internal SNMP agent and can be controlled by any generic SNMP station or by the RADview SNMP network management application. supports dial-in, dial-out modem connections. These connections can be used for remote out-of-band configuration, monitoring and for sending callout alarm messages using serial V.24 SLIP, PPP or Ethernet ports. Inband management can be performed by using the spare bits (Sa bits) on timeslot 0 or by using a dedicated timeslot using standard protocols, Frame Relay (RFC 1490), PPP and standard RIP2 routing. This allows setup, monitoring and diagnostics of the remote unit. Inband access by using spare bits on timeslot 0 is possible only if those bits are passed transparently end-to-end. When operating with CRC-4, E1 network statistics are stored in memory, according to RFC-1406. The statistic information may be retrieved locally through the control port. Maintenance capabilities include user activated local and remote loopbacks at the E1 main link, sub-e1 and data ports. The user can activate a BER test for each data or sub-e1 port, individually. Each data or sub-e1 port responds to an ANSI FT1 RDL (T1E1.2/93-003) inband loop code, generated by the remote, DXC or dedicated test equipment in a specific bundle of timeslots allocated only to that port. Figure 2. SDH Access Solution for Multiple Remote Sites

SPECIFICATIONS E1 MAIN LINK (NETWORK) Framing! 256N (no MF, CCS)! 256N (no MF, CCS) with CRC-4! 256S (TS16 MF, CAS)! 256S (TS16 MF CAS) with CRC-4 Bit Rate 2.048 Mbps Line Code AMI Signal Level Receive: 0 to -36 db / with LTU 0 to -10 db / without LTU Transmit: ±3V (±10%), balanced ±2.37V (±10%), unbalanced Zero Suppression HDB3 Impedance! 120Ω, balanced! 75Ω, unbalanced Jitter Performance! As per ITU G.823! ETSI TBR-12 and TBR-13! RJ-48c 8-pin, balanced! Two BNC coaxial, unbalanced Transmit Timing Internal accuracy: ±30 ppm Loopback timing: ±130 ppm Sub-E1: 2.048 Mbps ±130 ppm External timing from data port: n x 56, n x 64 ±130 ppm Compliance ITU G.703, G.704, G.706, G.732 FIBER OPTIC LINK Operating Wavelength 850, 1300 or 1550 nm (see Ordering) Receiver Sensitivity (For BER = 1x10-9 )! -38 dbm at 850 nm! -40 dbm at 1300, 1550 nm ST, FC/PC or SC (see Ordering) Output Power! -18 dbm for 850 nm into 62.5/125! -18 dbm for 1300 nm into 9/125! -12 dbm for 1300 and 1550 nm laser into 9/125 Dynamic Range 28 db for all types of optical interfaces Budget (Max)! 20 db for 850 nm over 62.5/125! 22 db for 1300 nm over 9/125! 28 db for 1300 and 1550 nm laser over 9/125 SUB-E1 PORT Framing! 256N (no MF, CCS)! 256N (no MF, CCS) with CRC-4! 256S (TS16 MF, CAS)! 256S (TS16 MF, CAS) with CRC-4 Bit Rate 2.048 Mbps Line Code AMI Zero Suppression HDB3 Impedance! 120Ω, balanced! 75Ω, unbalanced Signal Level Receive: 0 to -10 db Transmit: ±3V (±10%), balanced ±2.37V (±10%), unbalanced Jitter Performance! As per ITU G.823! ETSI TBR-12 and TBR-13! RJ-48c 8-pin, balanced! Two BNC coaxial, unbalanced Transmit Timing Locked on E1 main link Compliance ITU G.703, G.704, G.706, G.732 DATA PORT Number of Data Ports One Interface V.35, RS-530, V.36/RS-449, X.21 D-type 25-pin, female RS-530 pinout Data Rate n x 56 or n x 64 kbps, (n=1,2...,31) Clock Modes DCE: RX and TX clock to DTE DTE1: RX clock to user device; TX clock from user device DTE2: RX and TX from DCE Control Signals! CTS follows RTS or constantly ON, soft-selectable! DSR constantly ON, unless in test mode! DCD constantly ON, unless in RED ALARM ETHERNET BRIDGE/ROUTER PORT LAN Table (Ethernet Bridge Port) 10,000 addresses Filtering and Forwarding Ethernet bridge port 15,000 pps Ethernet router port 30/35 kbps Buffer 256 frames Delay 1 frame Standards Ethernet bridge port Conforms to IEEE 802.3 / Ethernet Ethernet router port Conforms to IEEE 802.3 / Ethernet II 10BaseT (UTP): Shielded RJ-45 GENERAL Diagnostics Main E1 link: Local and remote loopback Sub-E1 port: Local and remote loopback Sub-E1 port BER test Data port: Local data port loopback Remote data port loopback Data port BER test Inband code activated loopback per data port

Timeslot Allocation! Consecutive (bundled)! User defined Performance Monitoring (On E1 Main Link)! Local support of CRC-4! Statistics according to RFC-1406 Control Port (DCE)! Interface: V.24/RS-232! Connector: 9-pin D-type, female! Format: asynchronous! Baud rate: 1.2 to 19.2 kbps, autobaud! Character: 8 bit no parity, 7 bit odd or even parity Indicators General: Power (green), Test (yellow), MAJ ALARM (red), MIN ALARM (red) Main E1: LOC SYNC LOSS (red), REM SYNC LOSS (red) Sub-E1: LOC SYNC LOSS (red), REM SYNC LOSS (red) Alarms Last 100 alarms are stored and available for retrieval. Each alarm is time stamped. Alarm Relay 3 relay contacts are available on the control DTE port. The alarm relay is activated by alarms in the alarm buffer. Physical Height: 43.7 mm / 1.7 in Width: 44.4 cm / 17.3 in Depth: 24.3 cm / 9.5 in Weight: 1.3 kg / 2.9 lb Power 100-240 VAC; 47-63 Hz -48 VDC, nominal (36-72V) Power consumption: 6W Environment Temperature: 0 50 C / 32 122 F Humidity: up to 90%, non condensing ORDERING /*/~/$/&/@/#+ Modular E1 or Fractional E1 Access Unit * Specify optional drop-and-insert E1 sub-link: S1 for E1 sub-link ~ Specify power supply voltage: AC for 115 VAC and 230 VAC 48 for 48 VDC $ Specify management port interface: V24 for V.24/RS232 (DB-9) UTP for Ethernet 10BaseT (UTP) BNC for Ethernet 10Base2 (BNC) & Specify interface: 530 for RS-530 interface V35 for V.35 interface X21 for X.21 interface 449 for RS-449 interface ETUB for Ethernet bridge with 10BaseT interface ETBB for Ethernet bridge with 10Base2 interface ETUR for Ethernet router with 10BaseT interface ETBR for Ethernet router with 10Base2 interface @ Specify optional line interface: LTU for integral Line Termination Unit #+Specify optional optical interface: # ST for ST connector SC for SC connector FC for FC/PC connector + 85 for 850 nm, multimode 13 for 1300 nm, single mode 13L for 1300 nm, single mode, laser diode 15L for 1550 nm, single mode, laser diode (Default is G.703 electrical interface) Cables The following cables convert the 25-pin channel connector into the respective interface. Cable length is 2m (6 ft), unless otherwise indicated. CBL-HS2V1 to connect a V.35 DTE using DCE clock mode* CBL-HS2V2 to connect a V.35 DCE using DTE1 clock mode* CBL-HS2V3 to connect a V.35 DCE using DTE2 clock mode* CBL-HS2R1 to connect an RS-449 (V.36) DTE using DCE clock mode* CBL-HS2R2 to connect an RS-449 (V.36) DCE using DTE1 clock mode* CBL-HS2R3 to connect an RS-449 (V.36) DCE using DTE2 clock mode* CBL-HS2X1 to connect an X.21 DTE using DCE clock mode* * DCE clock mode: provides both transmit and receive clocks DTE1 clock mode: provides transmit clock, attached DCE provides receive clock DTE2 clock mode: attached DCE provides both transmit and receive clocks 176-100-06/00 2000 RAD Data Communications Ltd. Specifications are subject to change without prior notice. Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com