Operations and Installation Manual. Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

Similar documents
Keysight 85130D NMD 3.5 mm to 3.5 mm Adapter Kit

Keysight 85130F NMD 2.4 mm to 3.5 mm Adapter Kit

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Keysight E7515A UXM Firmware Update Tool

Operating and Service Manual

Keysight N5191A/93A UXG X-Series Agile Signal Generator

Keysight GUI Data Logger Software for U1731C, U1732C, and U1733C Handheld LCR Meter

Keysight Combiner and Mechanical Switches Upgrade Kit

Keysight N7015A/16A Type-C Test Kit. User Guide

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight N5990A Test Automation Software Platform

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Keysight N5990A DisplayPort Extended Tests Embedded DisplayPort

Keysight N5990A Type-C Extension. User Guide

Keysight Technologies 85131C/D/G NMD-3.5 mm -fto 3.5 mm Semi-Rigid Test Port Return Cables

Keysight Add 4-Port Capability Upgrade Kit

Keysight Technologies 85031B 7 mm Calibration Kit

Agilent W2100 Antenna Modeling Design System

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies 85050B 7 mm Calibration Kit

Keysight 85052D 3.5 mm Economy Calibration Kit

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Keysight 85032F Type-N 50 Calibration Kit

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

Keysight Add Source and Receiver Attenuators Upgrade Kit

Agilent InfiniiMax II 1168A/1169A Probes

Keysight Technologies 85052B 3.5 mm Calibration Kit

Agilent CSV Export Utility

Keysight Add 4-Port Capability Upgrade Kit

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

Agilent OBSAI Protocol Tester

Firmware Guide. Keysight PXIe Chassis Family

Keysight Technologies M9352A

Keysight M9393A PXIe Vector Signal Analyzer

Agilent G2721AA/G2733AA

86100 Series Infiniium DCA Oscilloscope

Agilent OpenLAB Chromatography Data System (CDS)

Agilent OpenLAB Data Store Administration. Guide for Administrators

Agilent Technologies E5385A 100-Pin Probe

BenchCel Workstations Software

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

User s and Service Guide

Reference Guide. Agilent Technologies Electronic Calibration Modules. RF Two-Port 85091C 85092C 85093C 85096C 85098C 85099C. RF Four-Port N4431B

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Keysight U2722A/U2723A USB Modular Source Measure Units

Errata. Agilent References in this manual. About this manual. Support for your product

User s and Service Guide

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Agilent Series Logic Analysis System

Fd PACKARD. Application Note 326. Coaxial Systems. Principles of microwave connector care HEWLETT. ,/ (for higher reliability and better measurements)

Agilent CytoGenomics 2.5

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

User s and Service Guide. Agilent Technologies 85052C 3.5 mm Precision Calibration Kit

User s and Service Guide

Keysight 909A/D Coaxial Terminations

User s and Service Guide

Agilent OpenLAB. Data Store. Maintenance Guide

Keysight M8000 Series BER Test Solutions

87421/22A Power Supply. Operating and Service Manual

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Precision N Coaxial Calibration Kit

Keysight N9912A RF Analyzer (2 MHz - 4 GHz) (2 MHz - 6 GHz)

Agilent OpenLAB Data Analysis Upload Download Tool. User s Guide

Keysight Low Frequency Extension (LFE) Upgrade Kit

RF Connector Handling Guidelines

365XA, 365XA-1, 365XD, and 365XD-1 Mechanical Calibration Kits

Agilent Technologies 11667A DC to 18 GHz Power Splitter

Agilent SureCall 3.5. Installation Guide. Agilent Technologies. For Research Use Only. Not for use in diagnostic procedures.

Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz)

Keysight 2-Port and 4-Port PNA-L Microwave Network Analyzers and 2-Port PNA-L RF Network Analyzer

Agilent OpenLAB. Data Store. Backup and Restore Guide

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

User s and Service Guide. Agilent Technologies 85033E 3.5 mm Calibration Kit

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number

Errata. Agilent References in this manual. About this manual. Support for your product

User s and Service Guide

Keysight Technologies N9020B MXA Signal Analyzer

Keysight Software. Installation Guide

User s and Service Guide

SERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL

Agilent 1260 Infinity Purification Solution

Agilent U2941A Parametric Test Fixture

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

User s and Service Guide

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies

* * Agilent Power Distribution Unit (PDU) Installation Guide

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Agilent OpenLAB Chromatography Data System (CDS)

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Automated Plate Labeling

Agilent 70612B K18 Switch Matrix

Keysight 346A/B/C Noise Source (Including Options 001 and 004)

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent ChemStation Plus

Keysight N108xA-Series IEEE Ethernet KR/CR Compliance and Debug Application

Keysight M937xA PXIe Vector Network Analyzer Modules

Transcription:

Operations and Installation Manual Keysight 85132E/F 3.5 mm to 7 mm Test Port Return Cables

Notices Keysight Technologies, Inc. 1987-2016 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Keysight Technologies, Inc. as governed by United States and international copyright laws. Trademark Acknowledgments Manual Part Number 85132-90010 Edition Edition 1, September 2016 Supersedes: February 2015 Printed in USA/Malaysia Published by: Keysight Technologies 1400 Fountaingrove Parkway Santa Rosa, CA 95403 Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED AS IS, AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, KEYSIGHT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. KEYSIGHT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL. Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license. U.S. Government Rights The Software is commercial computer software, as defined by Federal Acquisition Regulation ( FAR ) 2.101. Pursuant to FAR 12.212 and 27.405-3 and Department of Defense FAR Supplement ( DFARS ) 227.7202, the U.S. government acquires commercial computer software under the same terms by which the software is customarily provided to the public. Accordingly, Keysight provides the Software to U.S. government customers under its standard commercial license, which is embodied in its End User License Agreement (EULA), a copy of which can be found at http://www.keysight.com/find/sweula The license set forth in the EULA represents the exclusive authority by which the U.S. government may use, modify, distribute, or disclose the Software. The EULA and the license set forth therein, does not require or permit, among other things, that Keysight: (1) Furnish technical information related to commercial computer software or commercial computer software documentation that is not customarily provided to the public; or (2) Relinquish to, or otherwise provide, the government rights in excess of these rights customarily provided to the public to use, modify, reproduce, release, perform, display, or disclose commercial computer software or commercial computer software documentation. No additional government requirements beyond those set forth in the EULA shall apply, except to the extent that those terms, rights, or licenses are explicitly required from all providers of commercial computer software pursuant to the FAR and the DFARS and are set forth specifically in writing elsewhere in the EULA. Keysight shall be under no obligation to update, revise or otherwise modify the Software. With respect to any technical data as defined by FAR 2.101, pursuant to FAR 12.211 and 27.404.2 and DFARS 227.7102, the U.S. government acquires no greater than Limited Rights as defined in FAR 27.401 or DFAR 227.7103-5 (c), as applicable in any technical data. Safety Notices A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.

85132E/F Return Cables General Information To obtain optimum performance from this adapter kit, observe these simple precautions: Make connections carefully to avoid misalignment and connector damage, which will result in inaccurate measurements. Keep the connectors free of dirt and any particles. When you clean the connectors, try using compressed air first. Do not use abrasives. With a clean foam swab, apply only isopropyl alcohol. For more information, refer to the Connector Care for RF and Microwave Coaxial Connectors document. It can be viewed online by searching for part number 08510-90064 at www.keysight.com. Description The 85132E and 85132F differ from one another mainly in length and insertion loss specifications. Both are test port return cables designed specifically for use with 7 mm calibration and verification kits and test sets with NMD-3.5 mm ports as part of a network analyzer system. the 85132E consists of a single, 97.2 cm (38.25 inches) long cable with a 7 mm connector on the DUT end and an NMD-3.5 mm (f) connector on the test set end. The 85132E is used primarily with Reflection/Transmission test sets. The 85132F consists of two identical cables that are each 62.9 cm (24.75 inches) long and is used primarily with full S-parameter test sets. The cables in the 85132F cable set are also available individually as Keysight part number 85132-60017 (Was: 85132-60004). Any of the two individual cables can be used to make a set. 2 Operating and Service Manual 85132-90010

Specifications Keysight Technologies guarantees that the performance of your cables will equal or exceed the following specifications, at frequencies <18 GHz: SWR 1.3 (17.7 db return loss) Insertion Loss (in db) Recession of center conductor shoulder behind outer conductor mating plane. NMD-3.5 mm (f) connector 0.005 to 0.056 mm (0.0002 to 0.0022 inch) 7 mm connector with collet removed 0.005 to 0.021 mm (0.0002 to 0.0008 inch) Protrusion of 7 mm center pin with collet in place 0.05 to 0.25 mm (0.002 to 0.010 inch) Supplemental Performance Data The following data gives further information about the typical performance of 85132E/F cables. Magnitude stability (db) and Phase stability (degrees) 0.22 db change, 85132E 0.12 db change, 85132F Operating and Service Manual 85132-90010 3

with a 90 degree, 3 inch bend radius 0.16 (f) a +0.8, 85132E 0.13 (f) a +0.5, 85132F a. (f) = frequency in GHz. Electrical length of the 85132E cable is approximately 1.150 m and it is approximately 0.74 m for the 85132F. Performance Tests Use a network analyzer to perform the following tests upon your cables as soon as you receive them. Periodically repeat the tests to determine if the performance is still satisfactory or if the cables need to be replaced. Figure 1 Return Loss Setup Return loss is measured by connecting a 50 ohm fixed load termination through a 10 cm airline to the test cable, then attaching the cable to port one of the test set (see Figure 1). The effects of an imperfect load may be gated out using the network analyzer time domain option. Refer to your network analyzer s Help system for specific instructions on using the functions mentioned in the return loss test below. 1. Preset the analyzer. 2. Set a stimulus start frequency of the analyzer s lowest frequency. 3. Set a stimulus stop frequency of 18 GHz. 4. Set an IF bandwidth of 100 Hz. 5. Perform, and then save, a 3.5 mm 1-port S11 calibration. 6. With correction turned on, select the time domain mode. 7. Set a stimulus start time for the sweep to 0.05 nano-seconds. 8. Set a stimulus stop time for the sweep to 6.5 nano-seconds for the 85132F or 9.5 nano-seconds for the 85132E. 4 Operating and Service Manual 85132-90010

9. Select the gating function and gate-out everything but the cable. See Figure 2. 10.Select the analyzer s frequency domain mode. 11.Use the markers to read the return loss value. Figure 2 Analyzer Trace Showing Location of Gates and Airline Insertion loss is measured by terminating the cable with a short and then measuring return loss. Measure with the 1-port S11 calibration, made in the previous procedure, turned on. The values shown on the CRT represent an out-and-back path for the signal, which is twice the insertion loss for the cable. Therefore, it is necessary to divide your worst case insertion loss by 2 before comparing it to the specifications in the beginning of this document (see Figure 3). Figure 3 Insertion Loss Setup Operating and Service Manual 85132-90010 5

Replaceable Parts The following items are replaceable on the 85132E/F cables:. Item Part Number Six slot collets 85050-20001 A single 85132E 3.5 mm to 7 mm cable 85132-60018 Was: 85132-60008 Two identical cables 85132F 3.5 mm (f) to 7 mm cables 85132-60017 Was: 85132-60004 Equipment and Supplies The following equipment and supplies are required for the maintenance and use of, but are not supplied with, your 85132E/F cables. Item Part Number 7 mm gage kit (part of 85050B calibration kits) 85050-80012 50 ohm fixed load termination (part of 85050B calibration kits) 85050-60006 10 cm airline (part of 85051B verification kits) 85051-60007 Short (part of 85050B calibration kits) 85050-80007 Torque wrench, 3/4, 136 N-cm (12 in-lb) (part of the 85050B calibration kits) 8710-1766 Extractor tool (used to remove the collets) 5060-0370 Document: Connector Care for RF and Microwave Coaxial Connectors 08510-90064 Spanner wrench 08513-20014 6 Operating and Service Manual 85132-90010

Visual Inspection 85132E/F Return Cables Visual inspection and, if necessary, cleaning should be done every time a connection is made. Metal particles from the connector threads may fall into the connector when it is disconnected. One connection made with a dirty or damaged connector can damage both connectors beyond repair. Magnification is helpful when inspecting connectors, but it is not required and may actually be misleading. Defects and damage that cannot be seen without magnification generally have no effect on electrical or mechanical performance. Magnification is of great use in analyzing the nature and cause of damage and in cleaning connectors, but it is not required for inspection. Look for Obvious Defects and Damage First Examine the connectors first for obvious defects and damage: badly worn plating on the connector interface, deformed threads, or bent, broken, or misaligned center conductors. Connector nuts should move smoothly and be free of burrs, loose metal particles, and rough spots. What Causes Connector Wear? Connector wear is caused by connecting and disconnecting the devices. The more use a connector gets, the faster it wears and degrades. The wear is greatly accelerated when connectors are not kept clean, or are not connected properly. Connector wear eventually degrades performance of the device. Calibration components should have a long life if their use is on the order of a few times per week. Replace components with worn connectors. The test port connectors on the network analyzer test set may have many connections each day, and are therefore more subject to wear. It is recommended that an adapter be used as a test port saver to minimize the wear on the test set s test port connectors. Inspect the Mating Plane Surfaces Flat contact between the connectors at all points on their mating plane surfaces is required for a good connection. Look especially for deep scratches or dents, and for dirt and metal particles on the connector mating plane surfaces. Also look for signs of damage due to excessive or uneven wear or misalignment. Light burnishing of the mating plane surfaces is normal, and is evident as light scratches or shallow circular marks distributed more or less uniformly over the mating plane surface. Other small defects and cosmetic imperfections are also normal. None of these affect electrical or mechanical performance. If a connector shows deep scratches or dents, particles clinging to the mating plane surfaces, or uneven wear, clean and inspect it again. Devices with damaged connectors should be discarded. Determine the cause of damage before connecting a new, undamaged connector in the same configuration. Operating and Service Manual 85132-90010 7

Contacting Keysight Assistance with test and measurement needs and information on finding a local Keysight office are available on the Web at: www.keysight.com/find/assist In any correspondence or telephone conversation, refer to the Keysight product by its model number and full serial number. With this information, the Keysight representative can determine whether your product is still within its warranty period. 8 Operating and Service Manual 85132-90010

Operating and Service Manual 85132-90010 9

10 Operating and Service Manual 85132-90010

Operating and Service Manual 85132-90010 11

12 Operating and Service Manual 85132-90010

Operating and Service Manual 85132-90010 13

14 Operating and Service Manual 85132-90010

Installation Note Xxxxx-xxxxx 3

This information is subject to change without notice. Keysight Technologies 1987-2016 Edition 1, September 2016 www.keysight.com