ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

Similar documents
Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

PlexPower Factory Sealed Panelboard Increased Safety

SPECIALTY PRODUCTS. Flameproof housing Zones 1-2 and to encase video cameras. Used for onshore and offshore sites and process supervision.

SIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS

Viamaster LED Series Luminaires For ATEX and IECEx Governed Hazardous Locations

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

P Series PlexPower Distribution Panelboards Increased Safety

FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

Viamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations

Ex Junction Boxes & Control Stations

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

ATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

PHOENIX CONTACT - 01/2008

Ex-CELL Stainless Steel and Painted Steel Enclosures

DeltaV Bulk Power Supplies

Pneumatic Control/Feedback

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Actuators. Stackable Contact Blocks (1, 2, or 3) with Contact Blocks

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

Terminal Boxes Series 8118

Cable Entry Systems for Potentially Explosive Atmospheres

LS 6600 Technical Datasheet

Explosionproof Meter Housings

Grounding Monitoring Device Series 8485

Series Panel Mounted Control Devices

EJB Junction Boxes Dimensions Pg. 132

Linear Luminaire with LED Series 6412/5

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

5 Fieldbus Technology

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Variable Area Flowmeter DATASHEET

Pneumatic Control/Feedback

Flow Measurement SITRANS F M

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Trendmaster* Galvanic Isolator

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Ground Monitoring Device Series 8485

Contender LED Luminaires Enclosed and Gasketed Fixtures

DeltaV Bulk Power Supplies

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Level Measurement Continuous level measurement - Ultrasonic transmitters

Grounding Monitoring Device Series 8485

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Sensor boxes SRBG Key features

Ex e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612

Material pressure (bar) (Cv (US) kv x 1,2 Seat

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Flow Measurement SITRANS F M

VersaPro Non-Metallic Fluorescent

Micro Limit Switch Series 8064

Installation & Operation Manual

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

General Specifications

The Solid-State Decoupler (SSD)

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

SolConeX Wall-Mounted Socket, 16 A

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

General Specifications

Linear Luminaire with LED Series 6012/5

Cable entry systems for potentially explosive atmospheres

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Series 95000, 2/2 Direct solenoid actuated poppet valve

FLEX Ex Spring Clamp Terminal Base

EC-E1 10A. Extract from the online catalog. Order No.: Electronic circuit breaker, signal contact: 1 N/O contact, nominal current: 10 A

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

Flow Meter FC01-Ex FC01-Ex

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Ex-control switch Typ 292 without and Typ 293 with measuring instrument

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Operating Instructions

Threaded resistance thermometer Miniature design Model TR10-D

Pneumatic Control/Feedback

PHOENIX CONTACT - 12/2007

Thermocouples Model TC200, for Additional Thermowell

PI-EX-ME-2NAM/COC-120VAC

EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS

PI-EX-ME-2NAM/COC-24VDC

CHEP ATEX. IECEx. Explosion proof Camera Housing. and. Certified

Avanti HP Series Centrifuges Preinstallation

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

RT2Y Compact temperature switch intrinsic safety

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Zener Barriers Bulletin 937Z

Model VDL 115 Vacuum drying chambers for flammable solvents

Flow Meter FC01-Ex-CA (compressed air/gas) Ex-Durchflussmesser FC01-Ex-CA

Transcription:

Applications Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical, refineries and other industrial process facilities. Designed for use in Zone 21 or 22 areas where flammable dusts are present either continuously or intermittently. Food processing, dairy, brewing and other commercial facilities. JBEA Series: Terminal junction boxes for electrical low voltage and instrumentation connections in hazardous areas. Refer to technical data to define permitted number of terminal blocks and cable entries on selected junction boxes. ECEA Series: Enclosure for distribution and control applications can be customized at our workshop to house a large range of components; i.e. control units, switches, breakers, transformers, meters, etc. Features Operating temperature: PCe type: -55 C to +60 C (-67 F to 140 F) CAe type: -40 C to +55 C (-40 F to 131 F) Rail mounting. Refer to technical data to define permitted number and size of terminals and cable entries. Standard Materials Enclosure: gray painted grade marine aluminum alloy Hardware: stainless steel Options Nameplates. Consult your local sales representative for: Enclosures custom drilled and assembled at our factory. Empty enclosure with Ex U component marking for re-certification by notified body for CAe type. ATEX/IECEx Certifications and Compliances Certification PCe of Protection: Ex e II, Ex ia IIC, Ex ib IIC, Ex de IIC Temeprature class: T6 for Ta +40 C ( +104 F), T5 for Ta +60 C ( +140 F) of Protection: Ex td A21 Surface Temperature: T80 C to T95 C (T176 F to T203 F) Ambient Temperature: -55 C to +60 C (-67 F to +140 F) CE Declaration of Conformity: 50221 ATEX Certificate: LCIE 00 ATEX 6047 PCe CAe Certification CAe of Protection: Ex e II, Ex ia IIC, Ex ib IIC, Ex de IIC Temperature Class: T6 to T2 of Protection: Ex td A21 Surface Temperature: T80 C to T290 C (T176 F to T554 F) CE Declaration of Conformity: 50325 ATEX Certificate: LCIE 02 ATEX 6248X IECEx Certificate: IECEx LCI 04.0016X Certification CAe U of Protection: Ex e II of Protection: Ex td A21 Ambient Temperature: -40 C to +55 C (-40 F to +131 F) CE Declaration of Conformity: 5C241 ATEX Certificate: LCIE 09 ATEX 3036 U EURASEC Certification Certification PCe EURASEC N TC RU C-FR.ГБ05.B.00911 Certification CAe EURASEC N TC RU C-FR.ГБ05.B.00911 201

Catalog Numbering Guide JBEA Series Aluminum Junction Box JBEA E A 12 11 09 D1 JB Series ATEX/IECEx Certified Junction Box Method of Protection: E - Increased Safety I - Intrinsic Safety Material: A - Aluminum Length Dimensions mm (in): 12-120 (4.72) 17-170 (6.69) 21-215 (8.47) Width Dimensions mm (in): 11-110 (4.33) 20-205 (8.07) 38-380 (14.96) 32-320 (9.06) 42-425 (16.73) 48-480 (18.90) Depth Dimensions mm (in): 09-91 (3.58) 13-130 (5.12) 19-190 (7.48) Options: (options must be listed alphabetically) U - Component Certification U # - Customized Enclosure (Digit number will be assigned at time of order placement) JBEA Series: Ex e II Aluminum Junction Boxes For use with Ex certified terminals only (not supplied). Mounting rails supplied. Yellow laminated plastic label with black lettering. ECEA Series: Aluminum Enclosure for Distribution and Control Applications Designed to house a large range of components; i.e. control units, switches, breakers, transformers, meters, etc. Must be customized at our workshop with the following Catalog Number: Replace JB with EC, and add last digits and # for customized boxes. Example: ECEA 212013 # PCe1 PCe2 PCe3 CAe1 CAe2 CAe3 CAe5 Dimensions L x W x D mm (in) 120.0 x 110.0 x 95.0 (4.72 x 4.33 x 3.74) 170.0 x 110.0 x 95.0 (6.69 x 4.33 x 3.74) 230.0 x 110.0 x 95.0 (9.10 x 4.33 x 3.74) 215.0 x 205.0 x 130.0 (8.47 x 8.07 x 5.12) 320.0 x 205.0 x 130.0 (12.60 x 8.07 x 5.12) 425.0 x 205.0 x 130.0 (17.80 x 8.07 x 5.12) 480.0 x 380.0 x 190.0 (18.90 x 14.96 x 7.48) Rail Length Maximum Width mm (in) Weight kg (lb) Volume dm 3 (in 3 ) JBEA Series Catalog Number ECEA Series 94.0 (201.00) 1.0 (2.20) 2.2 (134.25) JBEA121109 ECEA121109# 144.0 (291.00) 1.3 (2.87) 2.7 (164.76) JBEA171109 ECEA171109# 204.0 (399.00) 1.6 (3.53) 5.2 (317.32) JBEA231109 ECEA231109# 191.0 (376.00) 4.0 (8.82) 13.0 (793.30) JBEA212013 ECEA212013# 293.0 (559.00) 5.0 (11.02) 23.0 (1403.60) JBEA322013 ECEA322013# 400.0 (752.00) 6.0 (13.28) 33.0 (2013.80) JBEA422013 ECEA422013# 335.0 (635.00) 11.0 (24.25) 53.0 (3234.30) JBEA483819 ECEA483819# 202

Accessories Zinc Plated Symetrical Steel Rail For direct fixing. Set of two 60 mm (2.36 ) height spacers supplied. Enclosure Rail Length mm (in) Catalog Number Pack CAe1 191 (7.52) JBEPDR215 1 CAe2 293 (11.54) JBEPDR320 1 CAe3 400 (15.75) JBEPDR425 1 Copper Bar 12 x 4 mm (0.47 x 0.16 ) Copper bar not perforated for cable clamps. Bar Length mm (in) Catalog Number Pack 160 (6.30) 097270 1 200 (7.87) 097271 1 310 (12.20) 097272 1 500 (19.68) 097273 1 690 (27.17) 097274 1 Cable Clamp for Copper Bar 12 x 4 mm (0.47 x 0.16 ) 1.5 mm 2 to 4 mm 2 (0.002 in 2 to 0.006 in 2 ) capacity. 097203 1 6 mm 2 to 16 mm 2 (0.009 in 2 to 0.025 in 2 ) capacity. 097204 1 Insulated Side Support Set of Two For mounting symmetrical, asymmetrical rails and copper bar 12 x 2 mm (0.47 x 0.08 ) or 12 x 4 mm (0.47 x 0.16 ). See dimensional data page for more details. 096115 1 JBEA Series for Junction Box Application Only. The size of the junction box needed to meet your requirements can be selected based on the table shown below. We also offer you the possibility to drill and equip, please consult our drilling guide available online at: www.appletonelec.com 1. Define maximum cable entries according to number of modules available per side. Cable Entry Metric Thread Number of Modules M20 1 M25 1 M32 1 M40 2 M50 3 Dimensions mm (in) Number of Modules Allowable Terminal Dim. Length Width Depth A/C B/B Max. Size H mm (in) PCe1 120 (4.72) 110 (4.33) 95 (3.74) 2 2 M25 110 (4.33) PCe2 170 (6.69) 110 (4.33) 95 (3.74) 2 3 M32 110 (4.33) PCe3 230 (8.46) 110 (4.33) 95 (3.74) 2 4 M32 110 (4.33) CAe1 215 (8.47) 205 (8.07) 130 (5.12) 11 8 M50 205 (8.07) CAe2 320 (12.60) 205 (8.07) 130 (5.12) 18 8 M50 205 (8.07) CAe3 425 (16.73) 205 (8.07) 130 (5.12) 26 8 M50 205 (8.07) CAe5 575 (22.64) 380 (14.96) 190 (7.48) 34 25 M50 380 (14.96) 2. Maximum Rail Arrangement According to Physical Dimensions Maximum Quantity of Horizontal Rails Terminal Capicity mm 2 (in 2 ) 2.5 (0.0039) 4.0 (0.0062) 6.0 (0.0093) 10.0 (0.0155) 16.0 (0.0248) 35.0 (0.0543) 50.0 (0.0775) PCe1/2/3 1 1 1 1 0 0 0 CAe1/2/3 1 1 1 1 1 1 0 CAe5 3 3 2 2 2 1 1 203

3. Defining maximum terminal block quantity according to power dissipation: Junction boxes used for instrumentation applications have very low current levels, therefore there is no risk of overheating whatever the number of terminals inside the box. For applications other than instrumentation, the following tables allow you to define your junction box depending on the number of terminals and the maximum authorized current being carried with feed-through terminals. For single feed terminals using cross connection, please consult your local representative for a calculation. For other terminal block configurations, please consult our drilling guide available online at: www.appletonelec.com 2.5 mm 2 (0.004 in 2 ) 4.0 mm 2 (0.006 in 2 ) 6.0 mm 2 (0.009 in 2 ) 10.0 mm 2 (0.016 in 2 ) T Rating: T6 CSPe1 120 x 120 x 91 mm (5 x 5 x 4 ) CSPe2 120 x 170 x 91 mm (7 x 5 x 4 ) CSPe3 120 x 230 x 91 mm (9 x 5 x 4 ) Quantity 12 22 33 I Maximum 15 A 13 A 12 A Quantity 10 18 28 I Maximum 20 A 19 A 16 A Quantity 7 14 21 I Maximum 32 A 27 A 24 A Quantity 4 6 8 I Maximum 50 A 50 A 50 A T Rating: T6 @ Ta +40 C (+104 F) T5 @ Ta +55 C (+131 F) 2.5 mm 2 (0.004 in 2 ) 4.0 mm 2 (0.006 in 2 ) 6.0 mm 2 (0.009 in 2 ) 10.0 mm 2 (0.016 in 2 ) 16.0 mm 2 (0.024 in 2 ) 25.0 mm 2 (0.039 in 2 ) 35.0 mm 2 (0.054 in 2 ) CAe1 200 x 215 x 150 mm (8 x 9 x 6 ) CAe2 200 x 320 x 150 mm (8 x 13 x 6 ) CAe3 200 x 425 x 150 mm (8 x 17 x 6 ) CAe4 200 x 575 x 150 mm (8 x 23 x 6 ) Quantity 20 21 23 38 I Maximum 16 A 16 A 16 A 16 A Quantity 19 20 23 38 I Maximum 20 A 20 A 20 A 20 A Quantity 12 13 14 23 I Maximum 32 A 32 A 32 A 32 A Quantity 10 11 18 30 I Maximum 40 A 40 A 32 A 32 A Quantity 8 10 13 22 I Maximum 28 A 27 A 25 A 26 A Quantity 8 8 10 20 I Maximum 67 A 73 A 69 A 60 A Quantity 8 8 10 12 I Maximum 79 A 86 A 80 A 100 A 204

ATX JBEA and ECEA Series Aluminum Enclosure Dimensions in Millimeters (Inches) PCe1 to PCe3 CAe1 to CAe5 External Internal Fixings A B C D E F G H Thick Ø PCe1 110 (4.33) 120 (4.72) 95 (3.74) 100 (3.94) 110 (4.33) 70 (2.76) 94 (3.70) 84 (3.31) 20 (0.79) 5.0 (0.20) PCe2 110 (4.33) 170 (6.69) 95 (3.74) 100 (3.94) 160 (6.30) 70 (2.76) 94 (3.70) 134 (5.28) 20 (0.79) 5.0 (0.20) PCe3 110 (4.33) 230 (9.10) 95 (3.74) 100 (3.94) 220 (8.66) 70 (2.76) 94 (3.70) 194 (7.64) 20 (0.79) 5.0 (0.20) CAe1 205 (8.07) 215 (8.47) 130 (5.12) 190 (7.48) 200 (7.87) 105 (4.13) 146 (5.75) 186 (7.32) 10 (0.39) 6.5 (0.26) CAe2 205 (8.07) 320 (12.60) 130 (5.12) 190 (7.48) 305 (12.01) 105 (4.13) 146 (5.75) 290 (11.42) 10 (0.39) 6.5 (0.26) CAe3 205 (8.07) 425 (17.80) 130 (5.12) 190 (7.48) 410 (16.14) 105 (4.13) 146 (5.75) 398 (15.67) 10 (0.39) 6.5 (0.26) CAe5 480 (18.90) 380 (14.96) 190 (7.48) 378 (14.88) 279 (10.98) 132 (5.20) 385 (15.16) 285 (11.22) 13 (0.51) 7.0 (0.28) Insulated Side Support (Rail Holder) 096115 Equipment Capacity L M CAe1 105 (4.13) 129 (5.08) CAe2 206 (8.11) 234 (9.21) CAe3 310 (12.20) 339 (13.35) CAe5 315 (12.40) 345 (13.58) 165 (6.50) DIN rail depth 15 mm Earth bar Support Cat. No. 96115 205