Before you begin. Unpack & Prepare. Install Hardware. Connect Hardware. Apply Power. Choose Management Method. Install & Use SANtricity Software

Similar documents
Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

1 Getting Started Installing & Configuring

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Shelves. Apply Power. Connect Data Hosts. Connect Ethernet Cables

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Shelves. Apply Power. Connect Data Hosts. Connect Ethernet Cables

System Storage DS3950 Quick Start Guide

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide

System Storage EXP3000 Rack Installation Instructions

IBM. Rack Installation Instructions

Rack Installation Instructions

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

N3240 Installation and Setup Instructions

LSI CTS2600 Controller-Drive Tray

N3220 Installation and Setup Instructions

E-Series Cabling E-Series Hardware

N3150 Installation and Setup Instructions

StorageGRID Webscale 10.2

Rack Installation Instructions

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide

Installing the Cisco MDS 9020 Fabric Switch

E-Series Maintaining E2800 Hardware

E-Series Site Preparation Guide

Adding, Upgrading, or Replacing Host Interface Cards in E2800 Controller Shelves

Sun StorageTek SL48 Tape Library Getting started

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

SGI InfiniteStorage 120

EXN3000 Storage Expansion Unit Installation and Setup Instructions

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

EXN4000 Storage Expansion Unit Installation and Setup Instructions

Sun StorageTek SL24 Tape Autoloader Getting started

Installing and Managing the Switch

DSA E-Series (E2700) DSA-N2E7X2-08AT DSA-N2E7Xx-12AT DSA-N2C7Xx-12AT DSX-N1D6Xx-12AT DSX-N6D6Xx-60AT DSX-NRCK40-INT

5000, 7000 Series StorSimple Appliance. Rack Installation Guide

Rack Installation Instructions

Installing a Cisco Nexus 3132Q-V cluster switch and a passthrough panel in a NetApp cabinet

Replacing the Power Supply

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide

Quick Installation Guide

Introduction to NetApp E-Series E2700 with SANtricity 11.10

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

IBM TotalStorage NAS 200 Model 25T. Quick Start Instructions

Installing the IPS 4345 and IPS 4360

StorageGRID Webscale 10.4 Appliance Installation and Maintenance Guide

SCv360 Expansion Enclosure

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

H3C S12500 Routing Switch Series

4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions

IBM System Storage DCS3860 Quick Start Guide

Dell SC460 Expansion Enclosure Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide

March , Revision B. SANnet II 200 SATA SE Array Quick Installation Guide

TRC-190 User s Manual

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

IBM Systems. Quick start guide for IBM System p5 505 ( )

Rack Installation Instructions

N6000 Series Filer Installation and Setup Instructions

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Removing Components from the MX960 Chassis Before Installing It Without a Lift

Data Domain DD6300, DD6800, and DD9300 Systems

Veritas NetBackup 5230 Appliance Hardware Installation Guide

Juniper Secure Analytics Quick Start Guide

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

SuperLoader 3 Quick Start Guide

Acano solution. Acano X Series Server 1.6 Installation Guide. May E

McAfee Network Security Platform

Model 2380 Rack-Mount Kit

Q40 Quick Start Guide

SwitchBlade Switch Controller Quick Install Guide

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

Quantum DXi4700 Capacity Upgrade Guide

Installation and Maintenance

actilib Library 2U Quick Start Guide

Installing the Interface Line Card in the Cisco cbr Chassis 6

ST2501 M2 Drive Module Initial Setup Guide

Quick start guide for p5 520 ( )

Introducing the Cisco 1121 Secure Access Control System Hardware

TRC-190 User s Manual

Snap Server 4400 Power Supply

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

16Hi HARDWARE INSTALLATION GUIDE

Adding or Replacing a PCI Card

1. Move the cardboard carton close to the installation site, making sure you have adequate space to remove all the contents of the box.

Heat Containment System (HCS)

Model 2380 Rack-Mount Kit

Eaton Heat Containment System (HCS) Installation Guide

G3-APEX-ENT-32T. Apex technical specifications. Parts list

M40e and M160 CIP Installation Instructions

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

VTRAK E610f, J610s Quick Start Guide

FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. Setup Guide

Dell EMC Data Domain DD9500 and DD9800 Systems

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Rack Installation Guide

MegaRAID Remote Kit for the LSIiBBU06, LSIiBBU07, and LSIiBBU08 Intelligent Battery Backup Units. Quick Installation Guide

Installation Job Aid for Ethernet Routing Switch 5900 Series

Catalyst 2360 Switch Getting Started Guide

AI130 AIswitch Series 130 Chassis Installation Guide

1. Unpacking the System

Transcription:

Before you begin Installation and Setup Instructions for EF-Series All-Flash Arrays EF550 and EF560 flash arrays DE5600 flash expansion trays Unpack & Prepare Before installing the hardware Confirm that your location provides 40-volt AC power. Obtain a standard 9-inch (48.3-cm) rack to fit U trays with these dimensions: Tray Height Width Depth Max Weight EF550 or EF560 3.47 in. (8.8 cm) 9.00 in. (48.6 cm) 9.60 in. (49.78 cm) 57.3 lb (6 kg) Install any required host bus adapters (HBAs) in the data hosts as well as any required switches. Refer to the NetApp Interoperability Matrix at http://mysupport.netapp.com/matrix for compatibility information. For additional instructions Install Hardware Go to the E-Series and EF-Series Systems Documentation Center: http://mysupport.netapp.com/eseries. Download these documents from the Getting Started and Installing and Configuring sections of the page. Connect Hardware Apply Power Choose Management Method Task Preparing your site Installing a NetApp cabinet Installing the rails, trays, and drives Cabling the hardware Choosing a management method Installing and using SANtricity software Document Site Preparation Guide 3040-40U Cabinet Installation Guide Flash Array and Related Trays Installation Guide Hardware Cabling Guide Software Installation Reference SANtricity Storage Manager Express Guide (select the guide for your operating system and host protocol) Install & Use SANtricity Software For additional help NetApp Support: http://mysupport.netapp.com/ NetApp Training: http://www.netapp.com/us/services-support/university/learning.aspx NetApp Videos: https://www.brainshark.com/go/netapp-sell/library.html For your safety Review the Safety Notices document included in the box and pay close attention to the precautions for moving and installing hardware. 0-0660+A0

Unpack the boxes Obtain tools and other equipment Unpack all boxes and compare the contents to the items on the packing slip. You will find these items in the boxes. Flash array with 4 SSD drives (optional trays for 4 SSDs) Left and right end caps for each tray Cabinet rails and mounting hardware Power cords (two for each tray) You need additional tools and equipment to complete the installation tasks. Phillips No. screwdriver Medium flat-blade screwdriver ESD wrist strap Host Bus Adapter (HBA) (installed in each data host) SAN switch (optional, depending on host topology) Optional Tools I/O cables and transceivers (you might need to obtain the cables) Ethernet cables (as needed to connect to the management host) Management station (for SANtricity software) Serial cables (as needed for diagnostics or installation) SAS cables (included only with the drive trays) Power drill with Phillips head bit Flashlight

Register the hardware Install the rails Locate the product (chassis) serial number. You can find the number on the packing slip, in your confirmation email, or on the flash array after you unpack it. WARNING: Install hardware from the bottom of the cabinet up to the top to prevent the equipment from toppling over. Go to the NetApp Support Site: http://mysupport.netapp.com, or scan the QR code with a mobile device. You need this hardware to install the rails (the kit also includes extra screws): 3 Left and right rails 8 rail screws (4 for each rail, 4 for securing the tray) 8 washers (used only for cabinets with square holes) Extend the rail by loosening the two adjustment screws. Starting at the lowest available position in the cabinet, align the holes on the ends of the rails with the holes on the cabinet. Confirm that the rail is level. Secure the front of the rail to the cabinet by inserting one screw through the cabinet and into the top captured nut on the rail. Use the washers if the cabinet has square holes. 3 Sign into the site: If you do not already have a NetApp account, click Register Now to create an account. If you already have a NetApp account, click Sign In, and enter your username and password. Cabinet Front Adjustment Screws 4 Determine whether you need to register the hardware, as follows: If you are a... Follow these steps... NetApp customer who has registered hardware before. From the top menu, select Products > My Products.. Confirm that the new serial number is listed. 3. If it is, go to Install the rails. If it is not, follow the instructions below to register the hardware. New NetApp customer or any reseller customer. From the top menu, select Products > Register Products.. Enter the product serial number, and click Submit. 3. Enter the requested details, and click Submit. After your registration is approved, you can download SANtricity software. The approval process might take up to 4 hours. 4 5 Insert one screw through the cabinet and into the bottom captured nut on the rail. Secure the rear of the rail to the cabinet with two screws (and washers).

Install the rails trays Install the trays end caps WARNING: When fully loaded with drives, each tray weighs approximately 57 lbs (6 kg). Two persons are required to safely move the tray. Place the back of the tray (the end with the connectors) on the rails. Carefully slide the tray all the way into the cabinet. Left and right end caps cover the mounting flanges on the front of each tray. Left End Cap (with front panel LEDs) Right End Cap 3 Position the left end cap so that the slot in the end cap is aligned with the tab on the left side of the tray. Snap the bottom of the end cap in place. Repeat these steps for the right end cap. 3 Secure the tray to the front of the cabinet by inserting a screw through the center hole in each front flange and into the cabinet. 4 Secure the rear of the tray by inserting a screw through the center hole in each rear flange and into the rail. 5 Repeat these steps to install any expansion trays.

Connect to the expansion trays (if installed) Connect to the data hosts Skip this section if you did not install expansion trays. Refer to the Hardware Cabling Guide if you have more than two expansion trays or you are using another configuration than what is shown. Recommended cabling for EF550 or EF560 Refer to the figures to connect SAS cables between the controllers in the flash array and the environmental service modules (ESMs) in the expansion trays. Confirm that the blue tabs on the SAS cables face the bottom of the cabinet, and make sure each connector clicks into place. Flash Array Host bus adapters (HBAs), installed in the data hosts, are used to transfer data between the host, any installed switches, and the storage array. Before making any cable connections, confirm that HBAs are installed. Refer to the Hardware Cabling Guide for lists of supported cables and transceivers, the best practices for cabling, and detailed views of the host ports for your controller. Refer to the NetApp Interoperability Matrix (http://mysupport.netapp.com/matrix) for the supported host topologies. Insert the appropriate transceiver into each controller port that you plan to use, based on the host protocol and the host topology. Start with the lowest numbered controller port. You do not need transceivers for copper iscsi. One expansion tray Controller A Controller B Connect to the data host using direct attach topology or fabric topology, as required. To use direct attach topology ESM A Expansion Tray ESM B Connect each HBA directly to the host ports on controllers A and B, as in this example: Flash Array HBA HBA HBA HBA Data hosts with redundant HBA ports Two expansion trays (shown below the flash array tray) Controller A Controller B ESM A Expansion Tray ESM B A B Storage array with two host ports/controller Expansion Tray ESM A ESM B

Connect to the data hosts Connect power cords and apply power To use fabric topology Connect each HBA to a switch that is connected to the host ports on controllers A and B, as in this example: WARNING: Risk of electrical shock Before connecting the power cords, make sure that both power switches on each tray are off. HBA HBA HBA HBA Data hosts with redundant HBA ports Confirm that the two power switches on each tray are off. Redundant zoned switches Power Switch Storage array with four host ports/controller Power Switch To zone a switch, follow the instructions in the appropriate SANtricity Express Guide. 3 4 5 Connect the two power supplies in each tray to separate power distribution units (PDUs) in the cabinet. If you have expansion trays, turn on their two power switches first. Then, wait minutes before applying power to the flash array. Turn on the two power switches on the flash array. Do not turn off the power switches during the power-on process. The fans in each tray are very loud when they first start up. The loud noise during start-up is normal. Wait 0 minutes. Confirm that none of the amber LEDs on the front or back of any trays are illuminated. If an amber LED is on, there is a problem with a component. Use SANtricity Storage Manager to help resolve the problem.

Choose the management method Choose the management method (continued) Before installing SANtricity Storage Manager (the management software), decide how you want to connect the flash array to the management station. This section provides an overview to help you understand the two primary management methods: Ethernet connection (out-of-band) and host I/O connection (in-band). For complete details and step-by-step instructions for implementing these methods, go to http://mysupport.netapp.com/eseries and locate the appropriate SANtricity Express Guide or the Software Installation Reference. Ethernet connection (out-of-band) management method You manage the flash array using Ethernet connections between a storage management station and the controllers management ports. Ethernet Switch Management Station SANtricity Storage Manager Client SAN Switch Flash Array Management port on each controller Data Hosts If you choose out-of-band management, you can use one of these options to set IP addresses and add the storage array to SANtricity Storage Manager. Option : Manually set static IP addresses using a private network This is the recommended option, and it is explained in the SANtricity Express Guides. After connecting the management ports and waiting 3 minutes for DHCP to time out, you can set up a private network using these default addresses. You then change the IP addresses to match your network s requirements. Controller A, port : 9.68.8.0 Controller B, port : 9.68.8.0 Default subnet mask: 55.55.55.0 Option : Automatically set IP addresses using DHCP If you have a DHCP server, the IP addresses are assigned when you connect the controllers to the network. You can then set a permanent lease for each controller. This option is described in the Software Installation Reference. Option 3: Manually set static IP addresses using the Serial Interface This option is described in the Software Installation Reference. Host I/O (in-band) management method You manage the flash array using an Ethernet connection between a storage management station and a data host. Host-agent software installed on the host passes communications to and from the flash array over an existing I/O connection. The Ethernet ports on the controllers are not used. This method is not supported for all operating systems. Ethernet Switch Management Station SANtricity Storage Manager Client Agent Data Hosts SANtricity Storage Manager Agent SAN Switch Flash Array Host ports on each controller To use the in-band management method, refer to the Software Installation Reference.

Install and use SANtricity Install the rails Storage Manager The SANtricity Express Guides include step-by-step instructions for downloading, installing, and using SANtricity Storage Manager. To download the Express Guide for your operating system and host protocol: Go to http://mysupport.netapp.com/eseries. Locate the Installing & Configuring section of the page. 3 Click Install Management Software & Set Up the Network (Express Guides) (under Software Install). 4 Locate the SANtricity Express Guides for your operating system and host protocol. 5 Select to download a PDF file to your computer or an EPUB file to your mobile device. 6 Follow the instructions in the SANtricity Express Guides to download and install the software and to configure your system. NetApp Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: + (408) 8-6000 Fax: + (408) 8-450 Support telephone: + (888) 463-877 Document comments: doccomments@netapp.com Copyright 05 NetApp, Inc. All rights reserved.