AC System Monitoring Device. Andrew Jarrett Project Advisor: Professor Gutschlag Department of Electrical and Computer Engineering October 1, 2015

Similar documents
AC System Monitoring Device

Modular Rapid Monitoring System

Power System Network Simulator (PSNsim)

NAND/NOR Logic Gate Equivalent Training Tool Design Document. Team 34 TA: Xinrui Zhu ECE Fall Jeremy Diamond and Matthew LaGreca

PLC Fundamentals. Module 1: Introduction to PLC. Academic Services Unit PREPARED BY. August 2011

POWER SAVER METER USING MICROCONTROLLER TO SAVE ELECTRICITY UPTO 30-40%

Smart Power Flow Monitoring and Control

Dept. of Computer Science and Engineering

ECE 480 Design Team 3 Proposal. Power-over-Ethernet for Wireless Home Automation Sponsored by Texas Instruments

Home Security System with Remote Home Automation Control

FMEDA Report Failure Modes, Effects and Diagnostic Analysis and Proven-in-use -assessment KF**-CRG2-**1.D. Transmitter supply isolator

International Journal of Scientific & Engineering Research, Volume 8, Issue 4, April ISSN

Preliminary Design Report. Project Title: Human-Powered Sub. Team Name: Depth Perception

LPRDS-ETS. Lafayette Photovoltaic Research and Development System - Energy Transfer System Overview. Inspiration

GRID MODERNIZATION INITIATIVE PEER REVIEW

ELECTRIC LINEMAN PROTECTION USING USER CHANGEABLE PASSWORD BASED CIRCUIT BREAKER 1

Wide-Area Reliability Monitoring and Visualization Tools

IEEE SoutheastCon Hardware Challenge

SECURITY FOR ORGANIZING GSM DIGITAL NOTICE BOARD Dr. Sreeja Mole S S 1, D.Gurunath 2, Yasmeen 3

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

3D Metal-Plastic Printer for Fabrication of Antennas on Custom and Flexible Surfaces

HARDWARE MANUAL TMCM-1613 TMCM-1613-REC. Hardware Version V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany.

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

UNIVERSITY OF ENGINEERING & TECHNOLOGY LAHORE

GSM MODULE BASED SMART NOTICE BOARD

software.sci.utah.edu (Select Visitors)

Interference Suppression Capacitor

Chaithra S 1, Sowmya B J 2 1 PG Student, Digital Electronics, Department of ECE, SJB Institute of Technology, Bengaluru, India

MONITOR AND CONTROL OF AN EXCAVATOR ROBOT

Panasonic Semiconductor Push Product Overview (ASSP) Panasonic Industrial Devices Sales of America Semiconductor Team

High Efficiency, High Density AC/DC PFC Power Supply

HARDWARE OF SUPERVISORY CONTROL & DATA ACQUISITION SYSTEM

Optimizing Field Operations. Jeff Shaner

Antec Signature Series

12v Power Controller Project Board

Versatile Link and GBT Chipset Production

Design Progress Report: x10 Environmental Control System Brian Kennedy, David Ramsay University of Rhode Island, Department of Biomedical Engineering

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

INTERCONNECTION FACILITIES STUDY REPORT

ISPOR Student Network Committee Work Plan Template

EE324: Microcontrollers and Interfacing. Office Hours: Mon, Wed, to 11.30am. Microcontrollers and Interfacing

SYSTEM DESIGN SPECIFICATIONS ZIGBEE BASIC SYSTEM

CRAH Retrofit and Energy Savings Project

Project Plan. Project Plan. May Logging DC Wattmeter. Team Member: Advisor : Ailing Mei. Collin Christy. Andrew Kom. Client: Chongli Cai

3 PHASE FAULT ANALYSIS WITH AUTO RESET FOR TEMPORARY FAULT AND TRIP FOR PREMANENT

TRUEPOWER NEW 550-WATT POWER SUPPLY USER S MANUAL

Premium Online Series

Microcontroller-based under and over voltage protection device

NOAA N-Wave Update N-WAVE V. NOAA Research Network. Joint Techs Columbus 13 July 2010

GE Fanuc IC694ALG221. Rx3i PacSystem

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Providing the missing piece in your Condition Based Monitoring platform

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

5 to100 Amperes Linear Power Supply/Charger (120 Volt 60Hz) (220 Volt 50Hz)

XBee Based Garbage Pits Monitoring System with Information Updating To the Department

Asks for clarification of whether a GOP must communicate to a TOP that a generator is in manual mode (no AVR) during start up or shut down.

Design Document. May Logging DC Wattmeter. Team Member: Advisor : Ailing Mei. Collin Christy. Andrew Kom. Client: Chongli Cai

Prioritized Load Distribution system in Households

Interim Report Technical Support for Integrated Library Systems Comparison of Open Source and Proprietary Software

Project Abstract with Diagram(s)

SCS. PoE Technology. - Milind Tamhane Vice President Manufacturing D-Link (India) Limited D-Link (I) Ltd. All rights reserved.

ENGR 499 Project 6 Laser Projector

College of Computing, Engineering & Construction Electrical Engineering Course Descriptions

8051 Intermidiate Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

HARDWARE MANUAL TMCM-6110 V TRINAMIC Motion Control GmbH & Co. KG Hamburg, Germany. MODULES FOR STEPPER MOTORS

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

This report is based on sampled data. Jun 1 Jul 6 Aug 10 Sep 14 Oct 19 Nov 23 Dec 28 Feb 1 Mar 8 Apr 12 May 17 Ju

ESET 369 Embedded Systems Software, Fall 2017

MP7. Uninterruptible Power Supply

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

SPECIFICATION ESD FSP012-DWEA2 / 9NA Released Date:2012/10/05-16:57:28

Regional Group Nordic GRID DISTURBANCE AND FAULT STATISTICS

Experiment #4: Solid State Diodes Applications III

Information Technology Services. Informational Report for the Board of Trustees October 11, 2017 Prepared effective August 31, 2017

METERS AND MORE: Beyond the Meter

MISO PJM Joint and Common Market Cross Border Transmission Planning

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010

Module 1. Introduction. Version 2 EE IIT, Kharagpur 1

120 WATT FLEX ATX TYPE WITH ACTIVE PFC

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Title: Terms and Conditions for the Approval of Multiple Dimension Measuring Devices

Hitachi-GE Nuclear Energy, Ltd. UK ABWR GENERIC DESIGN ASSESSMENT Resolution Plan for RO-ABWR-0028 Safety System Logic & Control (SSLC) Class 1 HMI

To: Prof. Chang, Prof. Lasser From: Mark Robinton, Brandon Balkind Subject: Senior Project Proposal Date: 12/2/2004

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

ET345P Control Systems [Onsite]

DEVELOPMENT OF PAPF MODULE

Homework 6: Printed Circuit Board Layout Design Narrative

Library. Summary Report

DUALGSM MODEMS BASED IRRIGATION WATER PUMP CONTROLLER FOR ILLITERATES

Laboratory: Introduction to Mechatronics. Instructor TA: Edgar Martinez Soberanes Lab 1.

8051 Basic Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

New Concept for Article 36 Networking and Management of the List

ENGINEERING SPECIFICATION 90 WATT POWER SUPPLY PART NUMBER PA P1

How Power Problems Affect PLC Reliability

Conect 121 Upgrade. Copyright 2013 Conqueror Design and Engineering Ltd.

Yield Reduction Due to Shading:

電氣規格書 ESD NA

Iowa State University

Analog Resistive Touch Screen Controller TSC-45/RSA-E User s Guide

Town of Georgetown Comprehensive Plan

Transcription:

AC System Monitoring Device Andrew Jarrett Project Advisor: Professor Gutschlag Department of Electrical and Computer Engineering October 1, 2015

Outline Background Problem Background Problem Statement Constraints Scope Functional and Nonfunctional Requirements Design Approach and Method of Solution Proposed and Alternate Solutions Testing Solutions Economic Analysis Proposed Solution Parts Schedule Milestones Preliminary Schedule Societal and Environmental Impacts Summary and Conclusion 2

Problem Background for the AC System Monitoring Device Alternating current (AC) monitoring device is a device to monitor voltages, current, power factor, and other AC power characteristics Primarily used in power transmission monitoring and power system protection Key part of the smart grid Reliability Networking Capability Power Factor Control 3

Problem Statement for the AC System Monitoring Device View AC power characteristics AC voltage AC current AC power factor Power Factor control Switching capacitors 4

Constraints for the AC System Monitoring Device Must be a digital system Must be secure Limiting unauthorized access and control Must operate from 120 to 250 volt AC systems ECE Power lab limits Must be safe using device To the user 5

Scope for the AC System Monitoring Device Scope Monitor AC Voltage Monitor AC Current Calculate Power Factor Power Factor Correction Single-Phase AC Systems Display Interface Digital Processing Out of Scope Monitor DC Voltage Monitor DC Current Calculate Current Differential Transformer Protection Three-Phase AC Systems Network Interface Electrical Mechanical Controls 6

Functional Requirements Shall monitor AC voltage Shall monitor AC current Shall monitor AC power factor Shall control power factor 7

Metrics for Functional Requirements Max Min Tolerance Voltage Range 250 V 100 V ±15% Current Range 5A 0 A ±15% Power Factor Calculation 1.0 0.3 ±15% Control Power Factor N/A 1 Switch Control N/A 8

Nonfunctional requirements AC monitoring device should be reliable Stable microcontroller operations Accurate AC power characteristic outputs AC monitoring device should be usable User experience with the device 9

High Level System Block Diagram of the AC System Monitoring Device User Input AC Voltage AC Current AC Power Supply AC System Monitoring Device Display Power Factor Control 10

Subsystem Block Diagram of the AC System Monitoring Device AC Power Supply AC to DC Power Conversion AC System Monitoring Device Microcontroller Display AC Voltage AC Current AC Voltage Signal Conditioning Analog-to- Digital Conversion Power Factor AC Current User Input Power Factor Control Signal Conditioning Power Factor Controller 11

State Diagram of the AC System Monitoring Device Power On Initialize Display Power Factor Control Read User Input Retrieve Data 12

Design Approach Morphological Chart Functional Requirements Different means Numerical Evaluation Different means Nonfunctional requirement metrics Constraints Personal Experience C Programming with Atmel Relay control from Ameren Internship 13

Proposed Solution Use a programmable logic controller (PLC) Schweitzer Engineering Laboratories (SEL) Automation Controller (SEL-2411) AC Voltage and Current I/O Card Digital I/O Card to control power factor Used in power distribution control at Ameren 615V 600uF Capacitors 14

Alternative Solution ATmega128A Development Board HITACHI HD44780U LCD Display Hall Effect Sensor Full wave bridge rectifier Transformer 117Vac to 24Vac 615V 600uF Capacitor 120V 120A Power-transistor 15

Testing Use equipment from power lab to compare outputs of the device Verify AC voltage and current displayed Verify AC power factor displayed Test power factor correction Run a motor varying the load to change the power factor Connect device to control capacitor Verify operation of device to correct power factor Run device for periods of time to test reliability Usability testing through surveying 16

Economic Analysis of the AC System Monitoring Device SEL-2411 Controller Premium price Industrial grade Customizable 10 Year warranty Donated from SEL Free software to program ECE Power Lab Equipment 3-Phase AC Motor 615V 600uF Capacitors 17

Proposed Solution Parts Parts Quantity Price SEL-2411 Automation Controller (Base Price) 1 $ 950 SEL-2411 Expansion I/O Cards 5 $ 100 Total = $1450 18

Milestones 1. Research and Design Components Circuit Design Programming 2. Primary Stage of Functional Components AC Voltage Measurement AC Current Measurement User Interface Control 3. Secondary Stage of Functional Components Power Factor Calculation 4. Third Stage of Functional Components Power Factor Control 5. Final Overall System Testing 19

PERT Chart PERT Chart Estimated Days to Complete Forward Pass Early Start Early Finish Backwards Pass Late Start Late Finish Free Float Component Research 8.2 0.0 8.2 4.0 12.2 0.00 Circuit Design 16.7 8.2 24.9 12.2 28.9 0.00 Program Design 7.3 24.9 32.2 28.9 36.2 0.00 Monitor AC Voltage Build 12.0 32.2 44.2 36.2 48.2 0.00 Monitor AC Voltage Testing 6.0 44.2 50.2 48.2 54.2 4.00 Monitor AC Current Build 16.0 32.2 48.2 32.2 48.2 0.00 Monitor AC Current Testing 6.0 48.2 54.2 48.2 54.2 0.00 Calculate Power Factor Build 16.7 54.2 70.9 54.2 70.9 0.00 Calculate Power Factor Testing 12.0 70.9 82.9 70.9 82.9 0.00 Power Factor Control Control Build Critical Path Non-Critical 8.3 82.9 91.2 82.9 91.2 0.00 Power Factor Control Testing 6.0 91.2 97.2 91.2 97.2 0.00 User Interface Control Build 8.1 32.2 40.3 81.1 89.2 0.00 User Interface Control Testing 8.0 40.3 48.3 89.2 97.2 48.89 Overall System Testing 9.3 97.2 106.6 97.2 106.6 0.00 20

Preliminary Schedule Activity Start End Component Research 08/26/15 09/24/15 Circuit Design 09/24/15 10/15/15 Program Design 10/15/15 10/31/15 Monitor AC Voltage Build 10/29/15 11/26/15 Monitor AC Voltage Testing 11/26/15 12/09/15 Monitor AC Current Build 10/29/15 11/26/15 Monitor AC Current Testing 11/26/15 12/09/15 Calculate Power Factor Build 12/09/15 02/10/16 Calculate Power Factor Testing 02/10/16 02/25/16 Power Factor Control Build 10/29/15 02/17/16 Power Factor Control Testing 02/17/16 02/25/16 User Interface Control Build 10/29/15 02/25/16 User Interface Control Testing 02/25/16 03/09/16 Overall System Testing 03/09/16 03/24/16 21

Societal & Environmental Impacts More Reliable Energy Conservation Less periodic maintenance Safer 22

Summary & Conclusions Monitoring of 120/250 Vac systems and power factor correction. Proposed and Alternative solutions Testing device Economic analysis Preliminary Schedule Societal and environmental impacts 23

Q & A 24

Detailed Gantt Chart AC System Monitoring Device Schedule Expected Days to Complete Days to Complete 26-Aug 15-Sep 5-Oct 25-Oct 14-Nov 4-Dec 24-Dec 13-Jan 2-Feb 22-Feb 13-Mar 2-Apr 22-Apr Project proposal presentation Project proposal written report Webpage Release Progress Presentation & Performance Review Component Research Circuit Design Program Design Monitor AC Voltage Build Monitor AC Voltage Testing Monitor AC Current Build Monitor AC Current Testing Calculate Power Factor Build Calculate Power Factor Testing Power Factor Control Control Build Power Factor Control Testing User Interface Control Build User Interface Control Testing Overall System Testing Progress Presentation Student Expo Abstract Project Demonstration Final Presentation Student Expo Poster Printing Student Expo Poster Setup Student Expo Final Report Draft Final Report Final Web Page Advisory Board Poster Printing Deadline Advisory Board Poster Presentation 25

Metrics for Reliability Nonfunctional Requirements Performance Index MTBF (Mins) Points 480 > 10 360 7.5 240 5 120 2.5 < 60 0 26

Metrics for Usability Nonfunctional Requirements Objective: Units: Metric: The AC System Monitoring Device should be usable User subjective satisfaction Points will be assigned based on the following scale User is very satisfied with all key functions of the device - 10 points User is satisfied with key functions of the device missing other functionality - 5 points User is not satisfied with all the key functions of the device 0 Points 27

Morphological Chart Functions Means Monitor AC Voltage Full wave bridge rectifier to DC voltage signal Dual half wave rectifier to DC voltage signal Center tap bridge rectifier to DC voltage signal Industrial PLC Monitor AC Current Hall effect sensor Industrial PLC Monitor Power Factor Use data from AC voltage and AC current conversion with internal calculations done by microcontroller Look-up table to calculate the power factor from the AC voltage and AC current Industrial PLC Power Factor Control Output control from the same microcontroller that performs calculations. Power amplifiers will be used to interface with the AC system. Output control from separate microcontroller that receives voltage and current data will perform programmable logical operations. Power amplifiers will be used to interface with the AC system. Industrial PLC 28

Full wave bridge rectifier Hall Effect sensor Look-up table Output logic from same microcontroller Full wave bridge rectifier Hall Effect sensor Internal calculations Output logic from same microcontroller Numerical Evaluation Design 1 Design 2 Design 3 Industrial PLC Design objectives (O) & constraints (C) O: Reliable 10 7.5 10 7.5 10 7.5 10 7.5 5 O: Usable 10 10 10 10 5 C: Safe X X X C: Secure X X X X X C: Operate up to 250V X X X X X C: Digital system X X X X X 29

Alternative Solution Parts Parts Quantity Price Atmel ATmega128A development board 1 $ 58.79 HITACHI HD44780U LCD display 1 $ 14.99 117vac to 24vac Power Transformer 2 $ 47.90 12A 600V full wave bridge rectifier 2 $ 14.80 615V 600uF capacitors 2 $ 14.86 Hall effect sensor (SparkFun ACS712) 1 $ 7.95 120V 120A Power-transistor (IPP041N12N3 G) 5 $ 13.30 Total = $182.59 30