Overview and Application

Similar documents
IEC OBJECT MODELS OF MULTIFUNCTIONAL PROTECTION RELAYS

Introduction and Overview of IEC Communications. Schweitzer Engineering Laboratories, Inc.

Data Model of the Standard IEC 61850

IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China

ECE Supervisory Control & Critical Infrastructure Systems IEC Presented by Jake Groat Slides by Rick Liposchak, P.E.

ABB Automation & Power World: April 18-21, 2011 IEC connectivity, networking and state-of-the-art Relion protection/control technologies

ABB Group April 19, 2011 Slide 1

Trends, Lessons and Benchmarks

COLLABORATE TO WIN. 03/31/2017 Digital Substation Turning IEC61850 features into benefits. Peter Rietmann, Program Manager Digital Substation NA

Peter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO!

IEC Overview. Grant Gilchrist. Principal Consultant, Smart Grid Engineering November 2009

Communication networks and systems in substations Part 7-1: Basic communication structure for substation and feeder equipment Principles and models

IEC 61850: From Paper to Operation

IEC Test Equipment Requirements

An Insight into IEC Protocol mplementation with ERLPhase new generation Devices

/ Charlie Hsu, Sales, PSAC, Power System Division, TWABB, June.2013 IEC The Approach and the Standard. ABB Group July 1, 2013 Slide 1

How smart can the grid really be?

ABB Protective Relay School Webinar Series Using IEC61850 for Advanced, Reliable Feeder Automation. Bryan Shannon August 20, 2013

Impact of IEC communication protocol on substation automation systems

Program. 5 Day IEC Seminar and Training. XXXX Automation & Information Systems XXXX

Ethernet Network Redundancy in SCADA and real-time Automation Platforms.

Lecture #7 Substation Automation with IEC 61850

Pushing the limits. ABB product development based on the IEC standard

IEC Upgrade Instructions

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

IED Configurator. User Manual

IEC61850: Application Migration, Conformance and Interoperability Testing. International Conference IEC March 30, 2005 FURNAS Rio de Janeiro

Jim McGhee, Utility Market Manager, RuggedCom Inc.

User Manual.

Applications and Industry Activities

Entergy Development and Deployment of IEC Protection and Control Including Process Bus

Importance of Interoperability in High Speed Seamless Redundancy (HSR) Communication Networks

Trends in Station Bus and Process Bus Communications Via the Several IEC Protocols. Schweitzer Engineering Laboratories, Inc.

TR IEC Deterministic Networking

IEC The Digital Power System. Mark Thompson National Grid IEC Engineering Manager

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Utilization of IEC GOOSE messaging in protection applications in distribution network

THE MODELING APPROACH OF IEC

November 29, ECE 421 Session 28. Utility SCADA and Automation. Presented by: Chris Dyer

C I R E D 22 nd International Conference on Electricity Distribution Stockholm, June 2013

This webinar brought to you by the Relion product family Advanced protection and control from ABB

IEC SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS

This is a preview - click here to buy the full publication

Ahead of the challenge, ahead of the change. Beyond classical substation How seamless communication networks can be used in special applications

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

Copyright 2017 SUBNET Solutions Inc.

IEC61850 Server in RTU32 & STRATON. A short IEC61850 Introduction and How to configure RTU32 IEC61850 Server

A NEW APPROCH FOR TEST IN SUBSTATION WITH ENTIRE APPLICATION OF IEC INCLUDING THE PROCESS BUS

Substation Automation Products. Line differential protection RED670 Relion 670 series

A solution for applying IEC function blocks in the development of substation automation systems

Digital Substation Overview of Technology, Industry

PAP13 - Harmonization of IEEE C with IEC and Precision Time Synchronization

Digitizing copper Defining key elements to ensure a successful integration from concept to maintenance

INTERNATIONAL STANDARD

Integrating IEC & IEEE 1815 (DNP3)

Upgrading From a Successful Emergency Control System to a Complete WAMPAC System for Georgian State Energy System

COMMUNICATION NETWORKS. FOX615/612 TEGO1 IEC GOOSE Proxy Gateway interface module.

INTERNATIONAL STANDARD

Peter Kreutzer, PSSAM/Automation Power World 2011 New Delhi, Secure and reliable Redundant communication network and cyber security

Industrial & Plant Communication Applications Seminar. April 3, 2006 College Station TX

Smart Grid Communications. WFCS 2016 May 3-6, 2016, Aveiro, Portugal

More Than Communication the Engineering Approach of IEC 61850

OfprintofarticleinPACWorld,Spring2008

Migration Paths for IEC Substation Communication Networks Towards Superb Redundancy Based on Hybrid PRP and HSR Topologies

Way Too Expensive & Complex

Jehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600

Engineering Approach for the End User in IEC applications

Process Bus and Sampled Values Based Applications

Substation Automation based on IEC Claes Rytoft ABB Power Systems

Designing a new IEC substation architecture

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

UNLOCK YOUR IEC TESTING EXCELLENCE

October 05, ECE 421 Session 12. Utility SCADA and Automation. Presented by: Chris Dyer

IEC INTEROPERABILITY BETWEEN RECORDERS AND RELAYS. R. Midence* Hugo Davila* Nan Zhan* * ERLPhase Power Technologies, Winnipeg, MB, Canada

Substation Configuration Language. Summary August 2006

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Application of IEC61850 in smart grid visualization, simulation and diagnosis

GOOSEING YOUR PARALLELING SCHEME

Protective Relays & SCADA Systems

Performance considerations in digital substations

IEC meets Industrial IT

FAST BUS PROTECTION USING IEC Cassandra Ha Goff

Energy Infrastructure Demands Mission Critical Networking

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Grid Automation Controller COM600 How it fits into the Smart Grid?

Learn IEC Configuration In 30 Minutes

An Investigation into the Testing and. Commissioning Requirements of IEC Station Bus Substations. Robert Peter Accendere

AMA ServerSim-G Server-Simulator for IEC Data Sheet

IEC Engineering Process and Multi-Vendor System Configuration Tools Reduce Engineering Costs of Substation Automation Projects

Electrical Integration with Smart Communication

////// SUBSTATIONS. Control command and local Scada

Designing Non-Deterministic PAC Systems to Meet Deterministic Requirements

TECHNICAL REPORT IEC/TR

Simplifying Protection System Design for Distribution Substations

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Using GOOSE with SPA-ZC 400 Ethernet Adapter and RE_541/3/5 Terminals

IEC Conformance Testing

Station Integration for Reduced Costs and Improved Operational Efficiency

Smart Grid Architecture Committee (SGAC) Standard Review IEC Suite of Standards White Paper November 2011

Transcription:

IEC 61850 Overview and Application Who am I? Rich Hunt Market Development Leader GE Grid Solutions Over 25 years in the power systems industry At GE for 10 years (almost) Member of IEEE PSRC, U.S. Representative to CIGRE B5 (protection and control), Member of IEC TC57 WG10 (the 61850 WG) 2 1

What we ll talk about Overview of IEC 61850 concepts Definition of terms maybe Using IEC 61850 in specific applications What can be done, and why Main-Tie-Main Autotransfer scheme 3 IEC 61850 Concepts 2

IEC 61850 2 concepts We can know a piece of information What it represents Where it comes from We can trust it We can share this information with other devices Publish/subscribe MMS 5 What 61850 is All 61850 defines How we know information How we share information What 61850 does not define What to do!!! Applications Devices Architectures 61850 is all nouns and no verbs 6 3

IEC 61850 Standard is 1200 pages over 10 parts (!!) Referenced by other standards Dependent on other standards The goal of the Standard is to define digital communications within a substation Protocols, data types, message formats Not applications Long term vision is interoperable devices Communications only Interoperable <> interchangeable 7 Parts of the IEC 61850 Standard Basic principles Part 1 Glossary Part 2 General Requirements Part 3 System and project management Part 4 Communication requirements Part 5 Substation Automation System Configuration Part 6 Basic Communication Structure (4 sections) Part 7 Part 8 Mapping to MMS and Ethernet Sampled Measured Values Mapping to Ethernet Part 9 Conformance testing Part 10 Structured Using Extensive Past Experience 8 4

Communications interfaces 9 Bay level 10 5

Station level 11 Process level 12 6

Station bus 13 Process bus 14 7

IEC61850 System Architecture To EMS/DMS/SCADA HMI Engineering Station WAN Station Interface NERC CIP SECURITY BOUNDARY Viewpoint Monitoring Station LAN (IEC61850 Station Bus) EnerVista Tools - Viewpoint Engineer UR UR UR Process Interface Brick Brick Brick Brick Brick Brick PROCESS BUS, IE 61850 15 IEC61850 Basics How 61850 works: Functional modeling of the power system Self-description of information Application-based transmission Publish-subscribe for right now data Client-server for must trust data XML for configuration, documentation 16 8

IEC 61850 Definitions Terms you hear: Station Bus & Process Bus Self description & Logical nodes Ethernet, VLANs, 7 Layer Stack GOOSE MMS and Client/Server SCL / XML 17 Functional Modeling of Data Logical Nodes Nothing more than object-oriented programming 18 9

Self-Description of Data 19 Self-Description Example Examples Feeder12.LD3.MMXU.MX.A.phsA Device location Feeder 12 Subset of device LD3 used for metering Logical Node Measurement Data Attribute Phase A Current Data Attribute Current Functional Constraint Measurands Examples Feeder12.LD6.XCBR.ST.Pos Device location Feeder 12 Subset of device LD6 used for control Logical Node XCBR = breaker status Data Attribute Position Functional Constraint Status 20 10

IEC 61850 Concepts Data Structures Logical Node Concept Definition: A Logical Node is an abstract model of a real device or function XCBR Circuit Breaker RSYN Protection Related YPTR Transformer The Model includes Data, Data Attributes, and Behavior 22 11

Logical Node Information Categories 23 Anatomy of an IEC61850 Object Names V A Functional Constraint MX MX Logical Nodes MMXU1 MMXU2 Logical Device (e.g. Relay1) Physical Device (network address) PhyDev-LD1.MMXU2.MX.A = Feeder #2 Current Measurements Intuitive, Standardized Object Naming 24 12

Circuit breaker model XCBR Information Tree 25 Logical Node Groups L System LN (2 9) P Protection (28 30) R Protection related (10 11) C Control (5 6) G Generic (3 4) I Interfacing and archiving (4 6) A Automatic control (4 5) M Metering and measurement (8 13) Examples: PDIF: Differential protection RSYN: Synchrocheck XCBR: Circuit breaker S Sensor and monitoring (4 11) X Switchgear (2) T Instrument transformers (2 20) Y Power transformers (4) Z Further power system equipment (15 18) F Functional Blocks (0 9) K Mechanical (0 5) Q Power Quality (0 6) Edition 2: Adds 3 new LN Groups Goes from 91 to 159 LNs Other LNs defined in TRs 26 13

Logical Node Objects IEC 61850 7-4 defines Logical Nodes IEC 61850 7-3 defines common data classes IEC 61850 7-2 defines functional constraints 27 PDIF example LN descriptions in 7-4 define data objects by: Name Data Class Required 28 14

PDIF Op ACT CDC descriptions in 7-3 define data attributes: Type Functional Constraint Trigger Operation Required 29 PDIF Op ACT ST 30 15

So let s define this: 31 To finish 32 16

Trust prottfmr01/primpdif1.st.op.general defines some information: Where it comes from What it represents But what about we can trust it? 33 Back to ACT All CDCs include: Quality TimeStamp TimeStamp is time when data changed Quality is what we know about this data 34 17

Quality 35 XCBR Logical Node Description SPS DPC SPC Mandatory/Optional Common Data Class Data Name Description 36 18

Single Point Status (SPS) Common Data Class (CDC) stval Attribute Name Type Functional Constraint Range of Values Mandatory/ Optional/ Conditional 37 Why functional modeling matters Reuse of information Once information is modeled in 1 device, it can be shared with other devices Configuration / mapping Once information is described in one location, it is known / mapped to all locations Described in Standard Parts 7-1, 7-2, 7-3, 7-4 38 19

Why we care Need to know LNs and data attributes to take share data Sharing can be used for information, for status, for control Need to know how other devices accept this data Example: XCBR, Pos, and DPS XCBR.Pos.stVal is a DPS Can end device accept DPS? 39 IEC 61850 Concepts Ethernet 20

Ethernet Interface Layers Gateway Router Bridge / Switched Hub Repeater / Shared Hub 41 Ethernet and the 7 Layer OSI Model 7. Application 6. Presentation 5. Session 4. Transport 3. Network 2. Data Link 1. Physical Logical Link Control Media Access Control (MAC) Network Access Card Network Media IEEE Std. 802.2 802.3 CSMA/CD 42 21

Why we care GOOSE, SV traffic are MAC address only Layer 2 traffic only Works with switches, does not pass routers MMS are Network traffic Layer 3 (uses IP address) Can theoretically pass routers 43 IEC 61850 Concepts GOOSE 22

Publish - Subscribe Data types Peer-to-peer messaging ( GOOSE ) Instantaneous sampled values ( SV ) Client-server messaging (HMI) Reporting (metering data for SCADA) 45 Publish Subscribe (Multicast) 46 23

Why we care GOOSE can replace field wiring One GOOSE can carry multiple pieces of information GOOSE goes everywhere on network segment Requires traffic shaping on large networks GOOSE uses retransmit for reliability Message sent multiple times to ensure receipt 47 IEC 61850 Concepts MMS 24

MMS Machine Messaging Service Uses a two party association model Essentially a point-to-point connection through the network Used for services, reporting Services means control, data access, file access, etc. 49 Services Concept Client-Server Functionality Summary 50 25

Reporting Automatic Transmission of Information based on Change Detection Unbuffered Reporting is typically used to feed an HMI Buffered reporting enables the server to retain data if associations are lost enabling the client to retrieve ALL data 51 Analog Data Change Detect The Deadband (db) is calculated as a % of the total RANGE of the value being measured (the % is a usersetting) In a Report, ONLY the mag value from the last Deadband detection is reported In a poll, the instmag value is read 52 26

Some architecture thoughts HMI client Unbuffered reporting for metering, status Local control commands Gateway Buffered reporting for metering, status, historical data Remote control commands Interlocking (maybe) Relays / meters as data servers Relays / distributed I/O as control points 53 Why we care If DCS / SCADA master is 61850 compliant Configuration is simpler (no point mapping!) Reporting is better than polling Trust but verify controls (SBO) 54 27

IEC 61850 Concepts Configuration SCL Substation Configuration Language Common description language configuring IEC 61850 communications in all IEDs XML based language that allows a formal description of Substation automation system and the switchyard and the relation between them IED configuration Standard Part 6 56 28

SCL File Types SSD: SCD: SED: ICD: CID: IID: System Specification Description XML description of the entire system Substation Configuration Description XML description of a single substation System Exchange Description XML description of a project IED Capability Description XML description of items supported by an IED Configured IED Description XML configuration for a specific IED Instantiated IED Description XML description of commissioned device 57 IEC 61850 configuration process 58 29

Top Down Configuration 59 Bottoms Up Configuration 60 30

Takeaways Need to have some understanding of basic Logical Nodes Need to know how GOOSE works Need to know which files to use Need to understand your application first! 61 An Example 31

Example: Main-Tie-Main Autotransfer Example M-T-M scheme: Open residual voltage transfer Close transfer to restore Auto-restore possible GOOSE messaging makes this simpler, faster, repeatable Use Bottoms Up configuration approach 63 M-T-M Hardwired 64 32

Fuse 1A Wiring count trip close 52a TOC Mandatory Hardwiring Inter-Relay Hardwiring Controls Hardwiring # of Relay Terminations Contact Inputs Used Outputs Used Incomer 1 VT #1 6 VT #2 2 Phase CT's 6 Trip Incomer 1 2 1 Close Incomer 1 2 1 Incomer 1 Status 1 1 Incomer 1 Racked In/Out 1 1 Incomer 1 Status to IN 2 2 1 Incomer 1 Status to Tie 2 1 Incomer 1 Undervoltage to IN2 2 1 Close Tie 2 1 Incomer 2 Status 1 1 Incomer 2 Undervoltage 1 1 Tie Connected 1 1 Tie Closed 1 1 Source Trip (94 or 87T) 1 1 Remote Close (52CS) 1 1 Remote Trip (52CS) 1 1 Selected to Trip (43-10) 1 1 Off/Auto Selector (43-83) 1 1 TOTAL (Fully Hardwired): 37 11 6 TOTAL (Inter-Relay Digitization): 25 7 2 TOTAL (Inter-Relay & Control Digitization): 20 2 2 65 Control Voltage Isolation Fuse 2A 66 33

Digitizing I/O trip close 52a TOC 67 Digitizing outputs with GOOSE 68 34

Main 1 Dataset 69 Tie, Main 2 Config 70 35

Main 1 RX GOOSE 71 Main 2 RX GOOSE 72 36

Tie RX GOOSE 73 Digitizing Inputs with GOOSE 74 37

Configuring Inputs: Main 1 75 Configuring Tie 76 38

Extending: ZSI 77 Some Ethernet network thoughts 39

Network Using 61850 requires an Ethernet network For a small sub, or switchgear lineup: 2 switches, with RSTP, is probably OK 5-10ms reconfig time means GOOSE gets through on retransmit Large sub, large network: not OK 79 GOOSE retransmit 80 40

PRP Parallel Redundancy Protocol Message duplicated across redundant networks Networks are normal networks 81 HSR High-availability Seamless Recovery Message duplicated both directions around ring Uses non Ethernet frames, so all devices must be HSR 82 41

The Big Finish Ethernet Networks RSTP network (1-2 switches) good enough for most applications PRP / HSR make sense on larger applications PRP is simpler: standard networks, testing is clear HSR can make sense: if HSR devices are available 84 42

Final Thoughts IEC 61850 is not an abstract thing: it has value for some applications M-T-M Scheme: GOOSE eliminates field wiring Allows standard, repeatable design Field changes are simple configuration (that can be lab tested!) Don t need to know the Standard inside and out Everything documented in XML Instantly, and consistently, understood by others 85 43