Immersion Temperature Sensors

Similar documents
Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Electrical Actuators

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Electrical Actuators

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Heating Circuit Controller

Room Temperature Controller

Universal Controller

Room unit with PPS2 interface

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Room Temperature Controllers

Resistance measuring module

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

Electromotoric actuators

Heating Circuit Controller

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Compact Universal Controllers

Power supply module, bus connection module

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Electrical Actuators

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Temperature controller Ducted systems

ERF910. RF Repeater. Synco living

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Master room unit for RRV controllers

Room Temperature Controller

Communication module to connect M-bus devices to POL6xx.xxx controllers.

TXM1.8RB. TX-I/O Blinds module

Electrical actuators

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Temperature Controller (Heat Pumps)

Semi flush-mounted room temperature controllers with LCD

Room unit with PPS2 interface

Level sensor Stainless steel version Model RLT-1000, for industrial applications

VAV modular controller

Temperature Controller

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

Non-communicating room controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Digital input modules

Fast running actuators for air dampers

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Solenoid Valves PN16 for gas flow interception

Overview of types. Technical data

VAV compact controller GDB181.1E/3 GLB181.1E/3

Electromotive actuators for combi valves

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

SEH62.1. Digital Time Switch

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Semi flush-mounted room temperature controllers with LCD

Central control unit

M-Bus Central Unit. Use

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection

Room unit with PPS2 interface

7-day room temperature controller

Room unit with PPS2 interface

Rotary version, three-position control

VAV compact controller KNX / PL-Link

Installation Instructions Temperature transmitter TAA /00 06/2011

Compact universal controllers

Electromotoric actuators

Electromotoric actuators

Web interface BACnet/IP

Island bus expansion module

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Room automation station

Temperature Switches

Air damper actuators

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

7-day room temperature controller

Semi Flush-mount Room Temperature Controllers with LCD

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

Operating Instruction

Super universal modules

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Level measurement. Applications. Special features. Description

Switching and Monitoring Device

Screw-in resistance thermometers with terminal head Form B

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Positioning modules with DC V output signals, and storage of positioning value

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Transcription:

1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or 420 ma Use The sensors are for use in ventilation and air conditioning plants for: Controlling or limiting the flow temperature Limiting the return temperature Controlling the DHW temperature Type summary Type reference Outfit Immersion length Operating voltage Output signal QAE2164010 QAE2164015 QAE2174010 QAE2174015 100 mm AC 24 V ±20 % / DC 13535 V 150 mm AC 24 V ±20 % / DC 13535 V DC 010 V DC 010 V 100 mm DC 13535 V 420 ma 150 mm DC 13535 V 420 ma CE1N1782en 21012005 Siemens Building Technologies HVAC Products

Ordering When ordering, please give name and type reference, eg: Immersion temperature sensor QAE2164010 Equipment combinations All systems or devices that are capable of acquiring and handling the sensor s DC 010 V or 420 ma output signal Function The immersion temperature sensor acquires the temperature of the medium via its sensing element whose resistance value changes as a function of the temperature This change is converted to a DC 010 V or 420 ma output signal, depending on the type of sensor The output signal corresponds to the selected temperature range Dummy load diagram Output signal, terminal I1 900 800 700 Inadmissible 600 range! Admissible 500 range 400 300 200 100 0 0 10 20 30 40 Operating voltage [DC V] Dummy load [Ohm] 1782D02en Mechanical design The immersion temperature sensor consists of housing, printed circuit board, connection terminals, immersion rod and protection pocket The 2-sectional housing is comprised of base and removable cover (snap-on design) The measuring circuit and the setting element are located on the printed circuit board inside the cover, the connection terminals on the base Cable entry is made via the M16 cable entry gland (IP54) supplied with the sensor which can be screwed into the housing Immersion rod and housing are rigidly connected The rod sits inside the protection pocket Setting element Range 1 2 3 Messbereich 123 Testfunktion aktiv U1 I1 10 V 5 V 0 V 20 ma 12 ma 4 ma 5 V 12 ma 1762Z01 The setting element is located inside the cover It consists of 6 pins and a shorting plug It is used to select the required measuring range and to activate the test function The different plug positions have the following meaning: 2/6 Siemens Building Technologies Immersion temperatur sensors QAE2164, QAE2174 CE1N1782en HVAC Products 21012005

For the temperature measuring range: Shorting plug in the left position (R1) = 0100 C, Shorting plug in the mid position (R2) = 10+120 C (factory setting), Shorting plug in the right position (R3) = 070 C For activating the test function: Shorting plug in the horizontal position: The values according to the table "Test function active" will be made available at the signal output Fault In the event of fault, the output signal will reach 0 V (4 ma) after 60 seconds Accessories (not included with standard delivery) Name Material Nominal pressure Type of sealing Immersion length Type reference Protection pocket V4A (14571) PN16 Threaded with sealing means 100 mm ALT-SS100 Protection pocket V4A (14571) PN16 Threaded with sealing means 150 mm ALT-SS150 Protection pocket V4A (14571) PN40 With flange for flat seal 100 mm ALT-SSF100 Protection pocket V4A (14571) PN40 With flange for flat seal 150 mm ALT-SSF150 For other protection pocket accessories, refer to Data Sheet N1194 Engineering notes Cable routing and cable selection If the nominal pressure exceeds PN10, protection pockets made of stainless steel (V4A) are required The temperature measuring range must be selected on the sensor, if required To power the sensor, a transformer for safety extra low-voltage (SELV) with separate windings for 100 % duty is required When sizing and electrically protecting the transformer, local safety regulations must be observed When sizing the transformer, the power consumption of the temperature sensor must be taken into consideration For correct wiring, refer to the Data Sheets of the devices with which the sensor is used The permissible cable lengths must be observed When laying the cables, it must be observed that the longer the cables run side by side and the smaller the distance between them, the greater the electrical interference Twisted pair cables are required for the secondary supply lines and the signal lines Mounting and installation notes Depending on use, the sensor should be located as follows: For flow temperature control (heating flow): Directly after the pump if the pump is located in the flow 15 to 2 m after the mixing valve if the pump is located in the return For return temperature limitation: In the return at a location where the temperature can be correctly acquired The sensor should be installed in an elbow such that the immersion rod or the protection pocket faces the direction of flow The water must be well mixed where the temperature is acquired This is downstream from the pump or, if the pump is mounted in the return, at least 15 m after the mixing point The sensor should be mounted such that the cable does not enter from the top With all types of sensors, the immersion length must be a minimum of 60 mm! The sensor must not be covered by lagging Siemens Building Technologies Immersion temperatur sensors QAE2164, QAE2174 CE1N1782en HVAC Products 21012005 3/6

To fit the sensor, a threaded fitting or T-piece G ½ must be welded into the pipe Mounting min 60 mm G ½ a b 1781Z02 c d 1781Z01 Note! For sensors with non-sealing threaded nipples G ½, sealing means must be used with the threaded connection (eg hemp, Teflon tape or similar) Mounting Instructions are printed on the packaging Technical data Power supply Cable lengths for the measuring signal Functional data Protective data Electrical connections Environmental conditions Operating voltage Frequency Power consumption Max perm cable lengths refer to "Type summary" 50/60 Hz at AC 24 V 1 VA refer to Data Sheet of the device handling the signal Measuring ranges 10+120 C (R2 = factory setting), 0100 C (R1), 070 C (R3) Immersion length refer to "Type summary" Sensing element Pt 1000 class B to DIN EN 60 751 Time constant With pocket Without pocket Measuring accuracy in the range of 070 C 40+120 C 30 s at 2 m/s 8 s at 2 m/s ±1 K ±14 K Output signal, linear (terminal U1) DC 010 V 10+120 C (factory setting) or 0100 C or 070 C, max ±1 ma Output signal, linear (terminal I1) 420 ma 10+120 C (factory setting) or 35+35 C or 070 C Dummy load refer to "Function" Nominal pressure PN 10 Housing IP 54 to IEC 529 Safety class III to EN 60 730 Connection terminals for 1 x 25 mm 2 or 2 x 15 mm 2 Cable entry gland (enclosed)) M 16 x 15 Operation Climatic conditions Temperature (housing) Humidity (housing) Transport Climatic conditions Temperature Humidity Mechanical conditions IEC 721-3-3 class 3K5 40+70 C 595 % rh IEC 721-3-2 class 2K3 25+70 C <95 % rh class 2M2 4/6 Siemens Building Technologies Immersion temperatur sensors QAE2164, QAE2174 CE1N1782en HVAC Products 21012005

Materials and colors Standards Weight Base polycarbonate, RAL 7001 (silver-grey) Cover polycarbonate, RAL 7035 (light-grey) Immersion rod stainless steel to DIN 17 440 steel 14571 Protection pocket brass (CuZn37) Cable entry gland PA, RAL 7035 (light-grey) Packaging corrugated cardboard Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Immunity Emissions -conformity to -conformity to Australian EMC Framework Radio Interference Emission Standard conformity UL 873 Incl packaging QAE2164010 QAE2164015 QAE2174010 QAE2174015 EN 61 000-6-2 EN 61 000-6-3 EMC Directive 89/336/EEC Radio Communication Act 1992 AS/NZS 3548 approx 022 kg approx 024 kg approx 022 kg approx 024 kg 5/6 Siemens Building Technologies Immersion temperatur sensors QAE2164, QAE2174 CE1N1782en HVAC Products 21012005

Connection terminals QAE2164 G G0 R1 = 0100 C / R2 = 10+120 C / R3 = 070 C U1 1782G01 QAE2174 G1 R1 = 0100 C / R2 = 10+120 C / R3 = 070 C I1 1782G02 G, G0 Operating voltage AC 24 V (SELV) or DC 13535 V G1 Operating voltage DC 13535 V I1 Signal output 420 ma for measuring range 10+120 C (factory setting), 0100 C or 070 C U1 Signal output DC 010 V for measuring range 10+120 C (factory setting), 0100 C or 070 C Dimensions 39 SW 22 G½ A ø 9 80 28 60 13 53,5 L M16 x 1,5 1782M01 Typ L QAE2164010 100 QAE2164015 150 QAE2174010 100 QAE2174015 150 Dimensions in mm 6/6 2004 Siemens Switzerland Ltd Subject to alteration Siemens Building Technologies Immersion temperatur sensors QAE2164, QAE2174 CE1N1782en HVAC Products 21012005