TM600 Real time flow totalizer and transmitter

Similar documents
Harpagon wiring instructions

Auper Electronic Controls Inc. Eclipse 784 B. Quick User Guide

DVI Extender over Single CAT5 Model #: DVI-C5-M-SET

User Manual rev: Made in Taiwan

USB-A to Serial Cable

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

DVI Extender over Single CAT5 Mini SET

User Manual CV-87K. PS/2 extender over cat.x. rev: Made in Taiwan

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

DVI over Single CAT5 Series CV-17. DVI over Single CAT5 Extender. User Manual. Made in Taiwan

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

HDMI 1.3 Matrix Switch Receiver over CAT5 with IR Pass-Through

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

AC4G-D User s Manual

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

WARRANTY & LIMITATION OF LIABILITY

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

Owner s Manual. Audio/Video with RS-232 and IR Control over IP Extenders

WARRANTY & LIMITATION OF LIABILITY

Eagle PT-MP1 Pan Tilt Communications Multiplexer Installation and Operations Manual Revision 3.0 August 20, 2001

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

1x2 HDMI Splitter over Cat.X with HDBaseT-Lite, 4K2K, IR & RS-232

Installation Manual. Flow Max 110

User Manual HDM-IPBX-003C. Smar t Controller for HDMI over IP series. rev: Made in Taiwan

XC300 VDSL Network Extender Owners Manual

Owner s Manual HDMI Matrix Switch

MULTIPLEXER MX4. Operation and Installation Manual. Pacific Micro Systems

USB-C to RJ45 FTDI Console Cable USB-A to RJ45 FTDI Console Cable

Chapter 1 : FCC Radiation Norm...3. Chapter 2 : Package Contents...4. Chapter 3 : System Requirements...5. Chapter 4 : Hardware Description...

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

User Manual rev: Made in Taiwan

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

1x4 HDMI & Full 3D support over Single CAT5 Distribution Amplifier with Local Output. User Manual

USB Transfer Cable. for Windows and Mac User s Guide

KVM HDMI over IP PoE Extender Kit Operation Manual

Owner s Manual. HDMI Over Cat5 1x2 Extenders. Models: B126-2A1, B126-2A0

FA-2448 SIX POSITION Filter Wheel

SMART SWITCH. User s Manual. This product is to be used with the MySmartBlinds automation kit.

USB Server User Manual

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

UÊ, Ê* - 1 Ê Ê Ê " /",Ê

Manual Guide PT-SP-HD18-4K. Manual Guide. 1x8 HDMI Distribution Amplifier with 4K2K & HDCP Support. Model PT-SP-HD18-4K. Designed in Germany

Owner s Manual. Industrial-Grade USB to RS-422/485 Serial Adapter. Models: U IND (1-Port), U IND (2-Port), U IND (4-Port)

USER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter

DVI EDID Reader / Writer

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

Owner s Manual. VGA Over Cat5 Extender Kits with EDID Copy 2 Local, 2 Remote. Models: B and B A

1X2 HDMI Splitter with 3D Support

PRO-DVI-CAT. DVI over Single CAT5 Extender. User Manual. Made in Taiwan

Sonic Ruptor 400. User Manual

User Manual rev: Made in Taiwan

User Manual CV-57H. HDMI Extender over Single Cat.X with Direct Plug-in Receiver 7.1 CH AUDIO. rev: Made in Taiwan

USER MANUAL. Kramer Electronics, Ltd. Models:

Owner s Instruction Manual

MicroLink Installation Operation & Specifications Manual. General Description

MultiVideo DP. Installation and Operation Manual. 1 4 Multi-head KVM Switch DisplayPort USB2.0 Audio Stancliff Road Houston, Texas 77099

Harpagon flow meter system. User guide

DVIKVM Extra Long Range Extender

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

INSTALLATION AND OPERATIONS MANUAL

MP3 Speaker USER GUIDE

Owner s Manual. USB 3.1 Gen 1 USB-C to HDMI Adapter

MTX-A Temperature Gauge User Manual

FieldServer X-25 Start-Up Guide

1x4 Splitter HDMI Distribution Amplifier with 4K2K & HDCP Support

Proliphix EPA-60 Installation Guide

Product Manual. USB Charging Hub 10 Port Hi-Power 2.4A USB Charger Hub. Coolgear, Inc. Version 1.1 September 2017 Model Number: U2CHGRHUB10

1x4 HDMI Splitter over Single Cat.X with HDBaseT-Lite, 4K2K, IR & RS-232. User Manual. rev: Made in Taiwan

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

Chore-Tronics Mobile Server

NIMBUS a personal dashboard for your digital life

USB Audio Converter. Installation and Operation Manual. USB to Analog Audio Converter Stancliff Road Houston, Texas 77099

Dual-Link DVI over 2CAT6 Extender

Broadband Automatic Disconnect Switch. User Manual

Owner s Manual. USB 3.1 Gen 1 USB Type-C to DVI Adapters

Kramer Electronics, Ltd. USER MANUAL. Model: RC-BT1 / BT-1. Bluetooth controller

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo

Installation and Operation Manual

URC Light Sensor SEN-LITE for use with MRX units containing sensor ports

An ISO-9001 Certified Company

USB2004EXT USB2004EXTGB. Instruction Manual. USB Extender. 4-Port USB 2.0 Extender over Cat5 or Cat6

WR-5e Remote Control

2GI. Touch Screen Wireless Keypad

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

Harpagon/Harpagon SRP 160 Flow meter systems User s Guide

PUSH-TO-TALK USER GUIDE

CV-505ZA. HDMI 2.0a Audio Extractor & Embedder. User Manual. rev: Made in Taiwan

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

K x2 HDMI 2.0a Splitter with Built-in & User Adjustable EDID Management. User Manual. rev: Made in Taiwan

fiber optic gateway control box

User Manual rev: Made in Taiwan

CI-1 and CI-8. Communications Interface Betsy Ross Drive Santa Clara, CA (408) FAX (408) P/N Rev.

Transcription:

TM600 Real time flow totalizer and transmitter Installation and user guide Rev 1 Auper Electronic Controls Inc All rights reserved 2013

GENERAL INFORMATION FCC INFORMATION This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and, (2) this device must accept any interference received including interference that may cause undesired operation. Note: The user is cautioned that any changes or modifications not expressly approved by the party responsible for FCC compliance could void the user s authority to operate the equipment. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of Auper Electronic Controls Inc. LIMITED ONE YEAR WARRANTY Auper Electronic Controls Inc. warrants that this product is in good working condition, according to its specifications at the time of the shipment, for a period of one (1) year from the date of purchase. Should the product, in Auper Electronic Controls Inc opinion, malfunction within the warranty period, Auper Electronic Controls Inc. will repair or replace the product without charge. Any replaced parts become the property of Auper Electronic Controls Inc. This warranty does not apply to the software component of a product or a product which has been damaged due to an accident, misuse, abuse, improper installation, usage not in accordance with product specifications and instructions, natural or personal disaster or unauthorized alterations, repairs or modifications. THIS WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT (AT AUPER S OPTION) ONLY AND DOES NOT INCLUDE ANY LABOR OR TRANSPORTATION CHARGES OR COMPLIANCE WITH ANY FEDERAL, STATE OR LOCAL LAWS, CODES OR REGULATION.

Notice of any claimed breach of said Warranty must be promptly given to the Auper authorized dealer from whom the product was purchased or leased. Upon request, all systems or parts which are claimed to be defective must be made available for inspection by and/or return to (at AUPER S option) such authorized dealer and/or Auper. No repair or replacement under said warranty will extend the original warranty period. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, ORAL OR WRITTEN, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE. LIMITATIONS All warranty for this product, expressed or implied, are limited to one year from the date of purchase and no warranty, expressed or implied, will apply after that period. No warranties for this product expressed or implied will apply to any person who purchases the product in used condition. The liability of Auper Electronic Controls Inc. with respect to any defective product will be limited to the repair or replacement of such product. In no event shall Auper Electronic Controls Inc be responsible or liable for any damages arising (a) from the use of the product; (b) from the loss of use, revenue or profit of the product; or (c) as a result of any event, circumstances, action or abuse beyond the control of Auper Electronic Controls Inc.; whether such damage be direct, indirect, consequential, special or otherwise and whether such damages are incurred by the person to whom this warranty extends or a third party. 2 P a g e

DISCLAIMER OF OTHER WARRANTIES AND LIABILITIES While all reasonable care has been taken in preparation of this product, it is provided as is, without warranty as to performance or fitness except as expressly stated above. The entire risk as to the quality of output developed with this product is assumed by the user. Auper Electronic Controls Inc does not warrant that the software or system will meet any particular requirements of the user, other than as expressly stated above, and specifically denies any liability for incidental or consequential damages resulting from the use of this software or system. Auper Electronic Controls Inc also specifically denies all liability for any technical or editorial omissions in its product documentation, and for any incidental or consequential damages resulting from the furnishing, performance or use of its documentation.

TM600 Real-time flow totalizer/transmitter PACKAGE TM600 control unit Two i-button manager keys 12 Volts DC transformer Flow meter junction box 25 ft (7.62 m) flow meter collector cable OPTIONAL RS-232 serial cable (serial printer, POS or computer) Serial printer Draft Manager Live software 4 P a g e

POSITIONING YOUR SYSTEM The TM600 being a control system, it should be installed in such a way as to be tamper proof that you choose to install it at the bar or in your office. Cables and connections should be protected and secured out of reach. The power source should not be installed where it can easily be disconnected. Do not connect the TM600 power source to an electrical outlet that can be turned off at night. 5 P a g e

SERIAL COMMUNICATION The TM600 is equipped with two programmable serial ports: The RS-422 port serial port connector is a RJ11 jack (phone jack). The RS-232 port connector is a Dsub 9 pin connector (male) SPECIFICATIONS Standard EIA RS-422 Physical Media Twisted Pair Network Topology Point-to-point Maximum Distance RS-422 1500 metres (4,900 ft) Mode of Operation Differential Maximum Baud Rate RS-422 100 kbit/s 10 Mbit/s Voltage Levels 6V to +6V (maximum differential Voltage) Mark(1) Negative Voltages Space(0) Positive voltages Available Signals Tx+, Tx-, Rx-, Rx+ (Full Duplex) RS-422 connector type RJ11 6 P a g e

The RS-232 port can be used with one system connected directly to a serial port of a computer running with the Draft manager software. Maximum distance RS-232 15.25 metres (50 ft) with straight cable or 44 metres (147 ft) using UTP Cat 5 cable RS-232 connector type DB9 male Maximum Baud Rate RS-232 115kbit/s Using RS-422 and the Auper AP821 RS-422 eight port hub, you can link several Auper metering systems to the same serial port on a computer or printer. This feature is useful to build large metering systems that require more than one control system. The system is also equipped with a real-time interface. When turned on, the TM600 will send the amount served through the serial port two seconds after the flow meter has stopped recording following a special communication protocol. To use this feature, you must use the Draft Manager Live software with the real-time interface. RED LED POWER FAIL INDICATOR The red LED on the TM600 will flash to signal that there was a power failure. To stop the LED from flashing apply a manager i-button key. 7 P a g e

CONNECTING THE FLOW METERS Figure 1 TM600 junction box Follow the instruction sheet supplied with the flow meters for complete step by step instructions. Since the flow meters are supplied with a 25 ft (7.6 M) cable, you should try to position your junction box to reach as many flow meters as possible. Flow meter cables can be extended 300 feet should you need to. The junction box will connect to the TM600 using a regular Cat 5 network cable terminated with RJ45 connectors. Cables are available for up to 150 ft (46M). Longer cables can be made on demand and can reach 300 ft (100 M). This is the same kind of cables used for computer networks, so you can always find them in computer stores or have them installed by local computer network contractors. Figure 2 RJ45 cable end 8 P a g e

The ends of flow meter cables have been stripped at the factory. Pull the insulation off the wire and cut the copper wire to get ¼ in (6mm) exposed only. Inspect each wire after to verify that you have not cut the copper wire and that all the strands are intact. Auper flow meters do not use an external power source. There is no voltage going to the flow meters so you cannot damage them even if you touch the wires. There is no positive or ground either. You do not have to worry about polarities. Connect the flow meters to terminals 1 to 6 and tighten the screw to secure the connection. DO NOT OVER TIGHEN SCREWS AS YOU MAY CUT THE WIRE. Inspect your connections before closing the cover to make sure that no wires are touching each other. If two wires are touching, the flow meter signal will be shorted and the flow meter will not send any signal to the TM600. Connect the network cable to the junction box. Secure all your cables using cable ties. Loose wires should be avoided at all times. 9 P a g e

CONNECTING THE TM600 Warning: Although this cable is the same as computer network cables, it is used to bring the flow meter signals to the TM600. This is not a computer network device. DO NOT CONNECT THIS CABLE IN ANY HUB, ROUTER OR OTHER ETHERNET DEVICE OR JACK. Run the UTP Cat 5 network cable between the junction box and the TM600 system. Securing the connector Use one of the small cable ties provided with the junction box to secure the connector in place. Slip the cable tie between the connector s body and the tab. The cable tie will prevent the tab from being pushed thus preventing anyone from disconnecting the cable. REMINDER: Securing the flow meter cables and junction box cables will effectively prevent people from tampering with the flow meter system. You should visually inspect the cables regularly. POWER SUPPLY Use a 12 Volts DC transformer at 0.5 amp to power the TM600. It s a good idea to plug the power supply into a surge protector or UPS (Uninterrupted Power Supply) to insure stable power to the unit. 10 P a g e

Connect the transformer to a power outlet. Avoid using inexpensive power bars as the transformer may fall and disconnect. Make sure the power source cannot be disconnected by the staff. A UPS (battery backup) is an added security since it will supply power to a TM600 for a long time in case of power failures insuring continuous power to the unit. 11 P a g e

POWER UP AND SET UP PRESS AND HOLD AS YOU APPLY A MANAGER I BUTTON KEY to enter the programming mode. Mode 1: IMPULSE MODE From left to right, 6 dots representing flow meters 1 to 6. When a flow meter is connected to a line, the corresponding dot is up. If no flow meter is connected to a line, the corresponding dot is down. When a flow meter detects liquid flowing through it, the corresponding dot will alternate up and down. If a flow meter is installed backward, the corresponding dot will be up but will not alternate when product is flowing. Verify that your flow meters are connected and registering by serving a little bit at each faucet. If you had not yet removed the air pocket from your beer lines, now is the time to do it. 12 P a g e

Mode 2 : UNIT SELECTION MODE The TM600 can be set to measure ounces or units of 1 (litres, gallons glasses etc ). To calibrate, you will serve a measured amount of liquid into a graduated cylinder during which time the system will read the number pulses sent by the flow meter. At this stage, you choose how you want the system to count and the amount you will serve into the graduated cylinder to calibrate. Press the button to toggle between ounces and units. To calibrate to count ounces, select Cal with 20 oz. To count units of 1, select Cal with 1 unit. Mode 3: CALIBRATION MODE As soon as you enter this mode, all six channels (lines) are ready to be calibrated. DO NOT LET ANYONE DISPENSE ANY LIQUID WHILE THE SYSTEM IS IN THIS MODE. Use the button to change the line number displayed on screen. TIP: For draft beer, you can kill the foam by spraying WD40 into the graduated cylinder before serving. You can stop to let the foam go down when you are in calibration mode. We recommend you watch the video on Youtube. Access is available from the Auper web site. You can search AUPERCONTROLS on Youtube to find the channel.. Serve 20 oz in a graduated cylinder as accurately as possible. If you selected Cal. with 20 oz. Serve 1 litre in a graduated cylinder as accurately as possible if you selected Cal with 1 unit and wish to count litres. 13 P a g e

Serve 1 glass if you selected Cal with 1 unit and wish to count glasses. If you serve too much on one line, stop and proceed with serving the selected amount at the other beer taps. Press the S/R button to calibrate after you have poured the amount at each tap. The value on the right will change to the new calibration value. You can view the calibration values of each line by pressing the button. If you need to recalibrate one of the lines, remain in that mode and serve the selected amount on this line only. As long as you do not touch the other taps, the registered pulses will remain 0000 and the system will not recalibrate. Mode 4: CLEAR MASTER COUNTER MODE This is the counter showing the amount of liquid dispensed since you started the system. You can clear a specific line counter in this mode. Select the line number with the button. Press S/R to clear the counter. Mode 5: CLEAR POWER FAIL COUNTER MODE The PWF (Power Fail) counter counts the number of times the TM600 was disconnected. As a precautionary measure, you should read this counter every time you read the line counters. The red LED on the TM600 will flash to signal that there was a power failure. To stop the LED from flashing apply a manager i-button key. Press the S/R button to clear the counter. 14 P a g e

Mode 6: MANAGER KEY Use this mode to program up to four manager keys in the system. Each key has a unique serial number and must be programmed into the TM600 to get access to the program modes. If you have lost a key, you can program a new one by applying it to the FOB. If you apply an already programmed key, you will exit the programming mode. Press to move between manager keys 1 to 4 Apply the new key Press S/R to accept it To delete a manager key Select the key number using the buttons Press and hold the S/R button and then press Mode 7: USER KEY User keys can be used to clear the daily counters only. They do not provide access to the programming modes. Up to 4 user keys can be programmed in the system. Press to move between user keys 1 to 4 Apply the new key Press S/R to accept it To delete a user key Select the key number using the buttons Press and hold the S/R button and then press 15 P a g e

Mode 8: BAUD RATE The baud rate is used only when connecting the TM600 to a computer or a serial printer. The default baud rate of most computers and printers is 9600 bps. Press the button to toggle between 9600, 19.2 K and 2400. Mode 9: SYSTEM NUMBER The system number is used to identify the TM600 on a printed report or by the computer if you use the Draft Manager software. You can set the number between 00 and 99. No more than one system can have the same system number if you connect several systems to the same computer or printer using an AP821 hub. Press to change the system number. Mode 10: INTERFACE MODE The TM600 is equipped with a real time interface mode. This mode can be used with the Draft Manager Live software. The TM600 will send the new counters for the line(s) used, 2 seconds after the tap was closed. The data will be sent through the serial port following a special communication protocol. TURN THE INTERFACE TO OFF IF YOU DO NOT USE DRAFT MANAGER LIVE. Press the S/R button to turn the interface ON/OFF 16 P a g e

Mode 11: PC COM RS232 If you connect the TM600 to a computer using the RS-232 port set this mode to RS-232. If you connect the TM600 to a PC using the RS- 422 port, set this mode to RS-422. Press to alternate between RS232 and RS422 Mode 12: PRINTER COM RS232 If you connect the TM600 to a serial printer using the RS-232 port set this mode to RS-232. If you connect the TM600 to a serial printer using the RS-422 port, set this mode to RS-422. Press to alternate between RS232 and RS422 Mode 13: VERSION MODE This mode identifies the firmware version and the MCU used to build your TM600. to go to mode 1. APPLY A MANAGER KEY TO EXIT. 17 P a g e

OPERATION RUN MODE Use to change the line on display The top line on display will show the amount currently being dispensed. The bottom number is the total dispensed for the shift. MCTR (MASTER COUNTERS) Use to change the line on display This is the amount measured since the day the system was started. Only managers can clear these counters from the programming modes. If you use the software, you should not clear these counters. POWER FAILURE COUNTER Shows the number of times the power was lost. PRINT REPORT Press S/R to start printing to the serial printer Press M to skip 18 P a g e

CLEAR DAILY COUNTERS Press S/R and hold as you apply a user/manager key The message counters cleared will appear and the system will revert to the normal run mode screen. 19 P a g e

ANNEXE PRINTER SETTINGS Baud rate: 9600 Parity: none Stop bit: 1 Handshaking: Xon/Xoff Print columns: 40 You can connect your TM600 to your computer (PC) to use the Draft Manager software and the Draft Manager LIVE software (cable and software purchased separately). USE RS-232 NULL MODEM CABLE PART 70-010 USB TO SERIAL CONVERTER Newer computers may not be equipped with 9-pin serial ports. A USB to serial adapter can be used. Drivers are provided with the converter and must be installed on the computer. Windows will assign the serial port automatically. You can find to which port your converter has been assigned at: USB to serial converter Control panel/system/device manager/ports (Com & LPT) Use default Windows serial port settings: 9600 bps 8 bits no parity, 2 stop bits Flux control to none. 20 P a g e

RS-422 SERIAL PORT CONNECTIONS You will use the RS-422 port for the following reasons: You wish to connect your TM600 to a computer more than 150 ft (50M) away. You have more than one metering system that you want to connect to the same computer or printer. SHORT DISTANCE RS-422 CABLE Short distance RS-422 connections (no more than 50 ft/ 15M) can be achieved using modular cables. The cables will connect directly from the system(s) into the AP821 hub. (Order the cables separately P/N 70-040-X). Modular cables are not twisted and offer no protection against ambiant noise. LONG DISTANCE RS-422 CABLE INSTALLATION RS422 modular cable RJ45 jack Option 1: Using UTP Cat5e 2 pair cable if you want to connect the devices directly to the RJ11 jacks of each RS-422 device. You can order those from the factory.the cables must be inverted if you make your own. Option 2: Using Cat5e 4 pair cable terminated with RJ45 jacks. And modular cables at each end. The RS-422 modular cables fit directly in the middle of the RJ-45 wall plate or coupler. You will need two modular cables for each Cat5e cable to reach the devices (one at each end). One modular cable must be straight (70-041) and one must be inverted (70-040) to end up with an inverted connection. RJ45 female coupler 21 P a g e

Flow meter N0. Brand Dispense point Calibration value 1 2 3 4 5 6 22 P a g e