Push button UP 287, 4 - fold

Similar documents
DELTA profil wall switch, single UP 241/2 5WG AB_2

584 5WG AB_1 DELTA

252F 5WG FB_1 DELTA

DELTA i-system wall switch single UP 221/2 5WG AB_2

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Push Button Interface UP 220D31

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and Application Description

Product and functional description

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and functional description

Product and functional description

Product and functional description

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

Product and Application Description

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

Product and Applications Description

Weather station AP 257/51

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Weather station GPS AP 257/61 Weather station AP 257/51

Product and functional description

Product and functional description

Product and Function Description

Operating and mounting instructions

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and function description

Product documentation

Product documentation

KNX/EIB Product documentation. Page 1 of 23. Order-No xx Order-No xx Order-No xx Order-No xx

Line Coupler, MDRC LK/S 3.1, GH Q R0001

Installation Instructions

Use of the application program

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

6173 AG GJB A0138

Technical Datasheet clima RCM-CC

Operating instructions only for authorized, skilled electricians with EIB training

Push-buttons 18. Light scenes push-buttons 21. Push-buttons with thermostat 22. Labelling ields 24

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

DELTA style 6/1. 6/6 Introduction. 6/7 Frames. 6/8 Switches and pushbuttons. 6/14 Socket outlets. 6/16 International plug-and-socket devices

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Room unit with PPS2 interface

Operating voltage Maximum

Use of the application program. Functional description. GAMMA instabus Application program description. March S1 rocker (BCU2)

Operating Instructions VEGAMET 381

Product documentation

Shutter/Blind Controls

Room unit with PPS2 interface

Communication objects. Use of the application program. Note. Functional description. Parameters General

ScreenLine Accessories MB model

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Operating instructions Evaluation system for flow sensors VS / / 2013

Digital input modules

TXM1.8RB. TX-I/O Blinds module

Use of the application program

Operating instructions. Switching amplifier DN0210 DN / / 2015

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

ABB i-bus KNX Binary Inputs BE/S Product Manual

EIB/KNX ENO Radio bus interface (32-channel)

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Bus coupler 3 Bus coupler 3 external sensor Order No

Technical Datasheet clima RCM-FC 1. Product description

Bus Connection Unit 560BCU04

UNIVERSAL DIMMER DIM02SA/500U

KNX USB INTERFACE UIMtp

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Water-protected surface-mounted push-button bus coupler Order No , , ,

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Operating instructions. Speed monitor D / / 2014

PHOENIX CONTACT - 07/2006

1. Function 1. System M multi-function push-button, 4- gang, with room temperature control unit. Table of Contents

Operating instructions. Standstill monitor A / / 2011

GVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

EY-SU 358: Push-button unit for room operating unit, ecounit358

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Power Supply HARTING pcon

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Electrical Actuators

Use of the application program

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Transponder card reader

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

Electrical Actuators

Transponder card holder

B.IQ push button comfort 1-4gang, Flush-mounted (Up) x, x, x, x

Demonstration Case BENNING DB 1

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

Extension module for lighting control

EDIFICIOS INTELIGENTES Y MULTIMEDIA: DOMOTICA Y CABLEADO ESTRUCTURADO

Power Supply HARTING pcon

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Transcription:

Product DELTA profil DELTA style Push button 1-fold pearl grey 5WG1 241-2AB01 titanium white 5WG1 285-2AB11 titanium white 5WG1 241-2AB11 basalt black 5WG1 285-2AB21 anthracite 5WG1 241-2AB21 titanium white metallic silver 5WG1 285-2AB81 silver 5WG1 241-2AB71 basalt black metallic silver 5WG1 285-2AB01 pearl grey titanium white anthracite silver 5WG1 242-2AB01 5WG1 242-2AB11 5WG1 242-2AB21 5WG1 242-2AB71 Push button 2-fold pearl grey 5WG1 243-2AB01 titanium white 5WG1 286-2AB11 titanium white 5WG1 243-2AB11 basalt black 5WG1 286-2AB21 anthracite 5WG1 243-2AB21 titanium white metallic silver 5WG1 286-2AB81 silver 5WG1 243-2AB71 basalt black metallic silver 5WG1 286-2AB01 pearl grey titanium white anthracite silver 5WG1 244-2AB01 5WG1 244-2AB11 5WG1 244-2AB21 5WG1 244-2AB71 Siemens AG UP 24_, 6 pages Technical Manual Electrical Installation Technology Siemens AG 2003 Update: http://www.siemens.de/gamma 2.16.1.5/1

Push button 4-fold pearl grey 5WG1 245-2AB01 titanium white 5WG1 287-2AB11 titanium white 5WG1 245-2AB11 basalt black 5WG1 287-2AB21 anthracite 5WG1 245-2AB21 titanium white metallic silver 5WG1 287-2AB81 silver 5WG1 245-2AB71 basalt black metallic silver 5WG1 287-2AB01 pearl grey titanium white anthracite silver 5WG1 246-2AB01 5WG1 246-2AB11 5WG1 246-2AB21 5WG1 246-2AB71 ordered separately from the DELTA ranges Frame cut-out frames Bus coupling unit UP 110; UP 114; UP 115 C2 C1 C1 Bus coupling unit C2 Frame Fixing screws *) Basic push button module *) Rockers *) *) Scope of supply Bild 1: Mounting the push buttons Product and Applications Description There is an upper and a lower operating field on the push buttons. In the middle of the push button there is a note panel in which pictograms can be inserted. This panel also contains display elements (LEDs) for orientation lighting and also for status displays. Opposing rockers are combined to form a pair e.g. for defined switching, dimming, controlling shutters and blinds. It is also possible to carry out the switching functions ON and OFF e.g. via a push button UP. Using an application program, the flush-mounted push buttons give commands via the flush-mounted bus coupler for example to actuators for defined switching on/off, for dimming lamps, raising/lowering shutters or for louvre adjustment or other parameterisable functional units. The device push buttons + IR is placed together with the relevant DELTA frame on the flush-mounted bus coupler and can only function in combination with the bus coupler UP and an appropriate application Technical Manual UP 24_, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2003 Electrical Installation Technology 2.16.1.5/2

program, i.e. the push buttons (with bus coupler UP) consist of the devices (hardware) and the application programs (software). The bus coupler UP and the relevant frame are not supplied with the device but must be ordered separately. Using the ETS program (EIB Tool Software), the application programs can be selected and the specific parameters and addresses can be assigned. Application Programs 12 S1 On-off-toggle/Dim/Shu/Display 211301 1 x switching on/off/toggle or 2 x toggle 1 x dimming or 1 x blinds control 1 x display actual state and 1 x orientation light 20 S1 Rocker (BA 2) 907402 (When using UP 114/02) 1 x switching on/off/toggle or 2 x toggle 1 x dimming or 1 x blinds control Scene (recall/store) 1 x display actual state and 1 x orientation light Notes for installation The device can be used for permanent interior installations, in dry rooms and for insertion in flush-type boxes. WARNING The device may only be installed and commissioned by an authorised electrician. The device may not be inserted in the same box as 230 V devices. The device may be used in switch sockets, if VDE approved devices have been used. The prevailing safety and accident regulations must be observed. The device may not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Technical data Power supply Via the flush-mounted bus coupler Operating elements 1, 2 or 4 pairs of rockers, idle in the middle position The pairs of rockers are interlocked via software so that malfunctions are not triggered when they are operated simultaneously. Number of switching cycles: > 20,000 Display elements per flush-mounted push button device 1 LED red as a display for orientation per pair of push buttons 1 LED red for status display e.g. 4-fold push button = 4 LED red. Connections 10-pole plug connector (PEI): for connection to the flush-mounted bus coupler Mechanical data Housing: plastic Dimensions: - DELTA profil (L x W x D ): 65 x 65 x 11 mm - DELTA style (L x W x D ): 68 x 68 x 14 mm Weight: approx. 40 g Fire load: approx. 950 kj 10 % Mounting: placed on the flush-mounted bus coupler Electrical safety Degree of pollution (according to IEC 60664-2): 2 Type of protection (according to EN 60529): IP 20 Protection class (according to IEC 61140): III Overvoltage category (according to IEC 60664-1): III Bus: safety extra-low voltage SELV DC 24 V Device complies with EN 50090-2-2 and IEC 60664-1: 1992 Reliability Rate of failure: 27 fit at 40 o C EMC requirements complies with EN 50081-1, EN 61000-6-2 and EN 50090-2-2 Siemens AG UP 24_, 6 pages Technical Manual Electrical Installation Technology Siemens AG 2003 Update: http://www.siemens.de/gamma 2.16.1.5/3

Environmental conditions Climatic withstand capability: EN 50090-2-2 Ambient operating temperature: - 5... + 45 C Storage temperature: - 25... + 70 C Relative humidity (not condensing): 5 % to 93 % Approval EIB-certified CE mark in accordance with the EMC guideline (residential and functional buildings) and the low voltage guideline Location and function of the operating and display elements A5 A5 Push button 1-fold Push button 2-fold A1 A2 A3 A4 A1 A2 A3 A4 Mounting General description The push button + IR is placed together with the relevant frame on the flush-mounted bus coupler. The flush-mounted bus coupler (C1) is connected to the flush-type box and fixed in position (refer to the installation instructions for the bus coupler). Mounting sequence Place the basic push button module (, diagram 3) with the relevant frame (C2) on the flush-mounted bus coupler (C1) and press the one strongly upon the other. Using fixing screws: If the fixing screws () are used first of all the rockers () have to be lifted out altogether. This can be achieved by inserting the screwdriver between the frames in the recess () and applying leverage (diagram 4). Important: The push button module (, diagram 3) and the rockers () together with the frame (C2) must be held down / pressed down. Screw down the fixing screws (). The rockers () have to be orientated properly and clicked upon the mounting rack (). Push button 4-fold C 1 A5 A1 A2 A3 C2 A4 Diagram 2: Location of display and operating elements A1 Upper operating field A2 LEDs for display A3 LED as an orientation light A4 Lower operating field A5 Cover for pictograms Diagram 3: mounting sequence Technical Manual UP 24_, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2003 Electrical Installation Technology 2.16.1.5/4

Drawing for mounting the fixing screws Lay the pictograms onto the foundation. Snap on the pictogram cover (A5) again. DELTA style Push button 1-fold 1) 2) 1) Insert the screwdriver between the frame and the push button module. 2) Swivel the screwdriver towards the wall. Diagram 6: Lifting out the pictogram cover Push button 2-fold / push button 4-fold Holding down as shown with push button 1-fold Diagram 4: Lifting out the rockers pictogram foundation a X) pictogram foundation Inserting pictograms Lift out the pictogram cover (A5) with the screwdriver by applying leverage, during this hold down the push button module (). DELTA profil Insert the screwdriver into the slot (A2) until it reaches the stop and then wiggle it. retaining tongue Diagram 7: inserting the pictograms Snap on the pictogram cover (A5) again. Dismantling Without fixing screws Remove the push button (, diagram 3) completely together with the frame from the flush-mounted bus coupler (C1): a) with the mere hand b) with a screwdriver beneath the frame / wall 1) 2) Diagram 5: Lifting out the pictogram cover Siemens AG UP 24_, 6 pages Technical Manual Electrical Installation Technology Siemens AG 2003 Update: http://www.siemens.de/gamma 2.16.1.5/5

a) b) General Notes Any faulty devices should be returned to the local Siemens office. If you have further questions about the product, please contact our Technical Support: With fixing screws Diagram 8: Dismantling +49 (0) 180 50 50-222 +49 (0) 180 50 50-223 adsupport@siemens.com Remove the rockers as described at Mounting / Using fixing screws. Screw out the fixing screws () Snap on the rockers () again Remove the whole push button module () as described at Without fixing screws. Dimension Diagram Dimensions in mm DELTA profil 65 65 10 DELTA style 68 68 14 Technical Manual UP 24_, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2003 Electrical Installation Technology 2.16.1.5/6