RZ7-FS Electronic Timing Relays

Similar documents
RZ7-FE Electronic Timing Relays

RZ7-FS Electronic Timing Relays

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

CS8 Industrial Control Relays

Syr-line TMR48D Digital Timer

Electronic timer CT-ERS.21

Syr-line TMR48D Digital Timer

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Electronic timer CT-ARS.11

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-AHD.22

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Electronic timer CT-ERD.12

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

General Purpose Relays R2N/R4N Miniature Power Plug-in Relays

Control, Timing + Ice Cube Relays

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Solid-state Timer H3YN

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

PROGRAMMABLE MULTI-FUNCTION

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

CS7 Industrial Control Relays

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

MasterINTERFACE 39 Series - Relay interface modules

Model Number Structure

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

TABLE OF CONTENTS Bulletin 700-HA General Purpose Relays and Timing Relays. Description Page Description Page. Description

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

3 Pole Contactors with AC operating coils

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Multi Voltage Options. Multi Voltage Options 110VAC + 24VAC/DC 230VAC + 24VAC/DC 24VAC/DC 110VAC 230VAC

1492-SP Supplementary Protectors

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

PRODUCT SPECIFICATION. PC Board Relays. Series.

CS7 Industrial Control Relays

93 SERIES. Timed socket for 34 series 93.68/93.69

ALLEN BRADLEY RELAY Bulletin 700-HF

Control & Timing Relays

PROGRAMMABLE MULTI-RANGE REPEAT CYCLE & DELAYED INTERVAL

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Electronic time relays ATI, BTI, SDT and MTI

TeSys IEC Contactors and Overload Relays

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Thermal-Magnetic Circuit Breaker 2216-S

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

02/11/2015

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Voltage Current Front-mounting bracket

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

NON-PROGRAMMABLE OFF DELAY, SINGLE SHOT

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

NON-PROGRAMMABLE ON DELAY, INTERVAL, TRUE OFF DELAY & FLASHER

70 SERIES. Line monitoring relay

Data sheet. CI-TI TM Contactors and Motor Starters Timers ATI, BTI, MTI 520B1307

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Bulletin 817 Thermistor Protection Relay

Bulletin 700-HA Tube Base Relay

Contact protection relay

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

em4 Accessories Digital expansions

Programmable Relay ZEN V2 Units

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Transcription:

RZ7-F Electronic Timing Relays Precision DIN-rail mounted timing relays for any industrial application The new multifunction RZ7-FM Electronic Timing Relay provides eight different timing functions and ten different timing ranges. 24 precher + chuh s new RZ7-F precision electronic timing relays offer 19 different output functions applicable to all types of industrial control. In addition to standard ON-Delay and OFF-Delay relays, the series also includes many specials such as an OFF- Delay that operates without supply voltage. Various timing ranges from 0.05 seconds to 60 hours are available, with many relays offering multi-time setting capability in the same device. olid state accuracy and reliability Except for their hard silver contacts, all RZ7-F timing relays are built with solid state electronics and controlled by a microprocessor. They are accurate to within 0.2 percent. Their ruggedness and high level of accuracy is due to the thorough testing of function, timing characteristics and surge voltage strength performed on each device prior to shipment. In addition, RZ7-F relays function reliably from % under rated operating voltage to 10% over rated voltage (AC). Voltage tolerance is even greater in DC applications. Eliminates additional relays The standard RZ7-F is supplied with one single pole double throw (PDT) contact within a compact case only 22.5mm wide. If more contacts are required, several relays are available that provide two separate, electrically isolated PDT contacts within the same narrow footprint. Output two is selectable as an instantaneous contact, which can eliminate the need for auxiliary relays in complex installations. These two pole relays can also be used with an external potentiometer for remote time setting. Multiple functions and timing ranges in one relay The RZ7-FM combines eight separate timing functions (plus ON and OFF functions) into one device. In addition, ten timing ranges are individually selectable from 0.05 seconds to 60 hours. These special relays reduce inventories and are ideal for maintaining remote installations where stocking several different timing relays would not be practical. Many safety and convenience features Every RZ7 accepts a broad range of AC and DC supply voltages without special ordering. Each relay is equipped with an LED that indicates four output status conditions. Finger and back of hand protection to IP40. Terminals are captive and supplied in the open position. All RZ7 s can be surface mounted, rail mounted, or mounted directly on our family of CA7/C7 or CA8/C8 devices. RZ7 relays can be mounted in any plane. Terminals, setting knob and LED s are all accessible from the front of the unit. are very compact, measuring approximately 1" x 3" x 4". Hazardous location timing relays also available. N014

eries RZ7-F Quick election uide ingle Function Timing Relays RZ7-F A 3 A 23 Type Function Contacts Time Ranges upply Voltages A On-Delay All functions: A 0.05 1 second tandard: B Off-Delay 3 One single pole B 0. 3 seconds 23 24 48VDC C On and Off-Delay double throw contact C 0.5 10 seconds 24 240V 50/60Hz D One hot / Watchdog D 1.5 30 seconds E Fleeting Off-Delay Functions A & B only: E 0.05 1 minute pecial Order: F ymmetric flasher starting with a pulse 4 Two single pole F 0. 3 minutes * 24 240VAC or DC ymmetric flasher starting with a pause double throw contacts 0.5 10 minutes A40 346 440V 50/60Hz I On-Delay pulse generator (Available with Time H 1.5 30 minutes Z12 12VDC J On-Delay (pulse controlled) Range only. Not I 0.05 1 hour * Not available with Time Range K One hot / Watch Dog (pulse controlled) available with J 0. 3 hours L Impulse Converter supply voltage) K 0.5 10 hours L 3.0 60 hours 0.05s 60 hours RZ7-F Q 3 Q Type Function Q Off-Delay Without upply Voltage Contacts 3 One single pole double throw contact 4 Two single pole double throw contacts Time Ranges Q 0.s 10 minutes upply Voltages 24 240VAC or DC Multi-Function Timing Relay RZ7-F M 3 23 Type Function Contacts Time Ranges upply Voltages M Multi-Function Eight single functions plus ON & OFF function (for installation/maintenance) - On-Delay - Off-Delay - On and Off-Delay - One hot / Watchdog - Fleeting Off-Delay - ymmetric flasher starting with a pulse 3 One single pole double throw contact 4 Two single pole double throw contacts 0.05 60 hours tandard: 23 24 48VDC 24 240V 50/60Hz pecial Order: 24 240VAC or DC A40 346 440V 50/60Hz Z12 12VDC pecial Function Timing Relays RZ7-F H 3 23 Type Function Contacts Time Ranges upply Voltages H Repeat Cycle Timer (Flasher) Includes four separate functions - upply voltage controlled, output starts with a pause - upply voltage controlled, output starts with a pulse - Pulse controlled, output starts with a pause - Pulse controlled, output starts with a pulse All functions: 3 One single pole double throw contact For equal timing of pulse and pause 0.05s 60 hours For separate timing of pulse and pause V 2 x 0.05s 60 hours tandard: 23 24 48VDC 24 240V 50/60Hz pecial Order: A40 346 440V 50/60Hz Z12 12VDC RZ7-F Y 2 C 23 Type Function Contacts Time Ranges upply Voltages Y Wye Delta Timing Relay 2 Two normally open C 0.5 10 seconds tandard: contacts D 1.5 30 seconds 23 24 48VDC E 0.05 1 minute 24 240V 50/60Hz F 0. 3 minutes 0.5 10 minutes pecial Order: A40 346 440V 50/60Hz Multi-time setting range. ee Technical ection for specific time settings. econd output selectable as timed or instantaneous. Timers with supply voltage code A40 (346...440VAC) are not L listed. RZ7-Fx4 models are not available with supply voltage code A40. N014 Discount chedule 1 25

eries RZ7-F RZ7-F Timing Relays ingle Function, One and Two Pole Description Diagram Terminal Arrangement Type Catalog Number Price u One PDT contact ingle timing range RZ7-FA3 23 102 ON-Delay Timing Relay (A) When supply voltage is applied, output contact(s) change state after time delay t. OFF-Delay Timing Relay (B) When control contact closes, output contact(s) change state immediately. When control contact opens, output contact(s) change state after time delay t. Constant supply voltage required on terminals /. Note: Control pulse duration minimum 50ms (AC) - 30ms (DC). Off-Delay Without upply Voltage (Q) ➏ When supply voltage is applied, output contact(s) change state immediately. When supply voltage is removed, output contact(s) change state after time delay t. u tp tp 25 26 / / / 25 26 / / 25 26 16 25 Z1 Z2 16 26 16 25 Z1 Z2 16 26 16 25 16 26 One PDT contact (from 0.05s to 60h) ➍ Two PDT contacts (from 0.05s to 60h) ➍ One PDT contact ingle timing range One PDT contact (from 0.05s to 60h) ➍ Two PDT contacts (from 0.05s to 60h) ➍ One PDT contact (from 0.s to 10min) ➎ Two PDT contacts (from 0.s to 10min) ➎ RZ7-FA323 107 RZ7-FA423 141 RZ7-FB3 23 102 RZ7-FB323 107 RZ7-FB423 141 RZ7-FQ3Q 203 RZ7-FQ4Q 237 upply Voltage ingle Function RZ7-F...23 timers (except RZ7-FQ) accept supply voltages of 24 48VDC and 24 240VAC (RZ7-FQ accepts 24 240VAC or DC). Other voltages are available by special order. ee Quick election uide on page 25 for details or contact your precher + chuh representative for information. For timing control, a voltage other than the supply voltage can also be used. Output two is selectable as an instantaneous contact by sliding a switch on the faceplate. Bridge or potentiometer 10kΩ, min. 0.25W (low voltage) for external time setting. ➍ Timing range is screwdriver selectable from the faceplate. Timing range selections include those found in the Timing Range Code chart. ➎ Timing range is screwdriver selectable from the faceplate. Exact timing ranges can be found in the Technical ection. ➏ Due to shock during shipment, the state of the contacts should be verified before initial use. Timing Range Codes Replace (Q) with Timing Range Code Timing Range Code 0.05 1 sec A 0. 3 sec B 0.5 10 sec C 1.5 30 sec D 0.05 1 min E 0. 3 min F 0.5 10 min 1.5 30 min H 0.05 1 hour I 0. 3 hour J 0.5 10 hour K 3.0 60 hour L RZ7-F two pole timing relay 26 Discount chedule 1 N014

eries RZ7-F RZ7-F Timing Relays ingle Function, One Pole Description Diagram Terminal Arrangement Type Catalog Number Price ON and OFF-Delay Timing Relay (C) When control contact closes, output contact changes state after time delay t. When control contact opens, output contact changes state again after time delay t. Constant supply voltage required on terminals /. Note: Closure duration of must be greater than t. / / 16 One PDT contact ingle timing range RZ7-FC3 23 114 One hot / Watchdog Relay (D) When supply voltage is applied, the output contact changes state for time period t. / 16 One PDT contact ingle timing range RZ7-FD3 23 114 Fleeting OFF-Delay Timing Relay (E) When control contact is pulsed, output contact changes state for time period t. Note: Control pulse duration minimum 50ms (AC) - 30ms (DC). ymmetric Flasher tarting With A Pulse (F) When supply voltage is applied, output contact changes state immediately and then repeatedly changes after every time period t, continuing until supply voltage is removed. / / / 16 16 One PDT contact ingle timing range One PDT contact ingle timing range RZ7-FE3 23 114 RZ7-FF3 23 114 upply Voltage ingle Function RZ7-F...23 timers accept supply voltages of 24 48VDC and 24 240VAC. Other voltages are available by special order. ee Quick election uide on page 25 for details or contact your precher + chuh representative for information. Timing Range Codes Replace (Q) with Timing Range Code Timing Range Code 0.05 1 sec A 0. 3 sec B 0.5 10 sec C 1.5 30 sec D 0.05 1 min E 0. 3 min F 0.5 10 min 1.5 30 min H 0.05 1 hour I 0. 3 hour J 0.5 10 hour K 3.0 60 hour L RZ7-F one pole timing relay For timing control, a voltage other than the supply voltage can also be used. N014 Discount chedule 1 27

eries RZ7-F RZ7-F Timing Relays ingle Function, One Pole Description Diagram Terminal Arrangement Type Catalog Number Price ymmetric Flasher tarting With A Pause () When supply voltage is applied, output contact changes state after time period t and then repeatedly changes again after every period t, continuing until supply voltage is removed. / 16 One PDT contact ingle timing range RZ7-F3 23 114 On-Delay Pulse enerator (I) When supply voltage is applied, output contact changes state after time period t. Output contact changes state again after 0.5 seconds. / 16 One PDT contact ingle timing range RZ7-FI3 23 114 On-Delay (pulse controlled) (J) When control contact is pulsed, the output contact changes state after time period t. One hot / Watchdog (pulse controlled) (K) When control contact closes, the output contact changes state immediately. After the last pulse of contact, the output contact changes state after time delay t. Impulse Converter (L) When a pulse is applied to control contact, the output contact changes state immediately for time period t. Pulses received during timing period t have no further effect. Note: The period t is not dependent on the length of the control pulse. Control pulse duration minimum 50ms (AC) - 30ms (DC). / / / / / / 16 16 16 One PDT contact ingle timing range One PDT contact ingle timing range One PDT contact ingle timing range RZ7-FJ3 23 114 RZ7-FK3 23 114 RZ7-FL3 23 114 upply Voltage ingle Function RZ7-F..23 timers accept supply voltages of 24 48VDC and 24 240VAC. Other voltages are available by special order. ee Quick election uide on page 25 for details or contact your precher + chuh representative for information. Timing Range Codes Replace (Q) with Timing Range Code Timing Range Code 0.05 1 sec A 0. 3 sec B 0.5 10 sec C 1.5 30 sec D 0.05 1 min E 0. 3 min F 0.5 10 min 1.5 30 min H 0.05 1 hour I 0. 3 hour J 0.5 10 hour K 3.0 60 hour L RZ7-F one pole timing relay For timing control, a voltage other than the supply voltage can also be used. Discount chedule 1 N014

eries RZ7-F RZ7-F Timing Relays Multi-Function, One and Two Pole RZ7-FM Multi-Function Relay Description Type Catalog Number Price Multi-Function Relay (M) The RZ7-FM multifunction relay combines eight timing functions plus ON and OFF functions (for installation and maintenance). Each timing function and timing range is selectable from the face of the relay with a screwdriver actuated knob. The RZ7-FM offers the following timing functions: On-Delay On and Off-Delay Fleeting Off-Delay On-Delay Pulse enerator ON Function (see below) OFF Function (see below) Off-Delay One hot / Watchdog Impulse Converter ymmetric Flasher tarting With a Pulse The two pole RZ7-FM4 offers two separate, electrically isolated single pole double throw (PDT) contacts which allow applications in complex installations without additional auxiliary relays. This series may also be operated remotely via an external potentiometer. One PDT contact Multifunction, multi-timing range relay (from 0.05s to 60h) ➍ Two PDT contacts Multifunction, multi-timing range relay (from 0.05s to 60h) ➍ RZ7-FM323 170 RZ7-FM423 203 On-Delay (A) u On and Off-Delay (C) Fleeting Off-Delay (E) Z1 Z2 16 26 25 Off-Delay (B) 25 / / 25 26 Z1 Z2 16 26 25 One hot / Watchdog (D) 25 26 ymmetric Flasher tarting With a Pulse (F) 25 Z1 Z2 16 26 25 Z1 Z2 16 26 25 On-Delay Pulse enerator (I) Z1 Z2 16 26 25 Impulse Converter (L) Z1 Z2 16 26 25 Z1 Z2 16 26 Z1 Z2 16 26 ON-Function OFF-Function Function display LED (reen) upply Voltage The RZ7-FM timer accepts supply voltages of 24 48VDC and 24 240VAC. Other supply voltages are available by special order. ee Quick election uide on page 25 for details or contact your precher + chuh representative for information. Output in rest position, no timing Output in rest position, time running Output in operation position, no timing Output in operation position, time running For timing control, a voltage other than the supply voltage can also be used. Output two is selectable as an instantaneous contact by sliding a switch on the faceplate. Bridge or potentiometer 10kΩ, min. 0.25W (low voltage) for external time setting. ➍ Function selection and timing range is screwdriver selectable from the faceplate. Exact timing range selections can be found in Technical Information. N014 Discount chedule 1 29

eries RZ7-F RZ7-F Timing Relays pecial Function, One Pole Description Diagram Terminal Arrangement Type Catalog Number Price Wye-Delta Timing Relay (Y) When supply voltage is applied, output contact Y closes for time period t. After time period t, plus a fixed time period t u, (50-65ms) output contact Δ closes. / 17/ 17/ L N 17 Y Δ Two single pole N.O. contacts ingle timing range RZ7-FY2 23 136 / / 16 Repeat Cycle Timer (H) - (Flasher) The Repeat Cycle Timer offers four different operating characteristics within the same relay. Depending on how the unit is wired, cycles are initiated either by supply voltage being applied or by a pulse from control contact. Regardless of the activation method, each cycle may begin with a pause or a pulse. The RZ7-FH3 relay sets the pulse and pause durations within one timing range setting. The RZ7-FH3V allows individual time settings of pulse and pause within two timing range settings. Both relays offer multiple time settings between 0.05s and 60h, selectable in ten increments. upply voltage controlled, output starts with a pause witch is up upply voltage controlled, output starts with a pulse witch is down Pulse controlled, output starts with a pause witch is up / / 16 / / 16 / / 16 16 16 16 One PDT contact (from 0.05s to 60h) Provides (1) range setting for t 1 and t 2 RZ7-FH323 136 Provides (2) range settings for t 1 and t 2 RZ7-FH3V23 136 Pulse controlled, output starts with a pulse witch is down 16 upply Voltage These timers accept supply voltages of 24 48VDC and 24 240VAC. A supply voltage of 346 440VAC is also available by special order. ee Quick election uide on page 25 for details or contact your precher + chuh representative for information. t 2 etting Timing Range Codes Replace (Q) with Timing Range Code Timing Range Code 0.5 10 sec C 1.5 30 sec D 0.05 1 min E 0. 3 min F 0.5 10 min 1 Range etting RZ7-FH3 RZ7-FH3V p witch Down eparate Range ettings t 1 etting For timing control, a voltage other than the supply voltage can also be used. Timing range is screwdriver selectable from the faceplate. Exact timing range selections can be found in Technical Information. 30 Discount chedule 1 N014

eries RZ7-F...-EX RZ7 Hazardous Location Electronic Timing Relays precher+chuh's RZ7 hazardous location relay timers have been designed to meet the stringent requirements of hazardous location applications while maintaining the functionality of the existing RZ7-F family of timing relays. The RZ7-FM4...-EX is a multi-function timing relay with 8 single-functions, PDT or DPDT contact output, and adjustable timing ranges. The -EX models are ideal for control panels installed in hazardous location areas such as in the oil, gas and petrochem industries. Multiple Approvals RZ7-FM423-EX RZ7-FK3C23-EX clus Industrial Control Equipment for Hazardous Location Listed 87L L Class 1, Div. 2, roups A,B,C,D L Class 1, Zn 2, roup IIC Temperature Code T4A, 2A 32VDC max. RZ7-F Hazardous Location Timing Relay ingle Function, One Pole Description Diagram Terminal Arrangement Type Catalog Number Price One hot / Watchdog (pulse controlled) (K) When control contact closes, the output contact changes state immediately. After the last pulse of contact, the output contact changes state after time delay t. / / 16 One PDT contact ingle timing range 0.05...1 second 0.5...10 second RZ7-FK3A23-EX RZ7-FK3C23-EX 124 upply Voltage ingle Function RZ7-FK3...-EX timers accept supply voltages of 24 48VDC and 24 240VAC. For timing control, a voltage other than the supply voltage can also be used. Technical data and dimensional information for the RZ7-F...-EX models are the same as the standard RZ7-F models. N014 Discount chedule 1 31

eries RZ7-F...-EX RZ7-F Hazardous Location Timing Relays Multi-Function, One and Two Pole ➎ RZ7-FM Multi-Function Relay Description Type Catalog Number Price Multi-Function Relay (M) The RZ7-FM multifunction relay combines eight timing functions plus ON and OFF functions (for installation and maintenance). Each timing function and timing range is selectable from the face of the relay with a screwdriver actuated knob. The RZ7-FM offers the following timing functions: On-Delay On and Off-Delay Fleeting Off-Delay On-Delay Pulse enerator ON Function (see below) OFF Function (see below) Off-Delay One hot / Watchdog Impulse Converter ymmetric Flasher tarting With a Pulse The two pole RZ7-FM4 offers two separate, electrically isolated single pole double throw (PDT) contacts which allow applications in complex installations without additional auxiliary relays. This series may also be operated remotely via an external potentiometer. One PDT contact Multifunction, multi-timing range relay (from 0.05s to 60h) ➍ Two PDT contacts Multifunction, multi-timing range relay (from 0.05s to 60h) ➍ RZ7-FM323-EX 3 RZ7-FM423-EX 220 On-Delay (A) u On and Off-Delay (C) Fleeting Off-Delay (E) Z1 Z2 16 26 Off-Delay (B) 25 / / 25 26 25 Z1 Z2 16 26 25 One hot / Watchdog (D) 25 26 ymmetric Flasher tarting With a Pulse (F) 25 Z1 Z2 16 26 25 Z1 Z2 16 26 25 On-Delay Pulse enerator (I) Z1 Z2 16 26 25 Impulse Converter (L) Z1 Z2 16 26 25 Z1 Z2 16 26 Z1 Z2 16 26 ON-Function OFF-Function Function display LED (reen) Output in rest position, no timing Output in rest position, time running Output in operation position, no timing Output in operation position, time running upply Voltage The RZ7-FM timer accepts supply voltages of 24 48VDC and 24 240VAC. For timing control, a voltage other than the supply voltage can also be used. Output two is selectable as an instantaneous contact by sliding a switch on the faceplate for RZ7-FM4 model. Bridge or potentiometer 10kΩ, min. 0.25W (low voltage) for external time setting for RZ7-FM4 model. ➍ Function selection and timing range is screwdriver selectable from the faceplate. Exact timing range selections can be found in Technical Information. ➎ Technical data and dimensional information for the RZ7-F...-EX models are the same as the standard RZ7-F models. 32 Discount chedule 1 N014

Accessories - Field Installable eries RZ7-F Electronic Timing Relays Accessories Accessory Description Catalog Number Price etting Knob With cale - For time setting without tools. RZ7-FK 8.50 Panel Mounting Adaptor - For surface mounting RZ7-F/FE timing relays. RZ7-FA 6.75 DIN-rail - 2 meter lengths ( 6' 6") Top Hat, low profile (price per rail Top Hat, high profile (price per rail) 3F 3AF ee page A54 Marking ystems Component Description Pkg. Qty. Catalog Number Price Each Label heet 1 sheet with 105 self-adhesive paper labels each, 6 x 17mm 1 CA7-FM Marking Tag heet - 1 sheet with 160 perforated paper labels each, 6 x 17mm. To be used with transparent cover. Transparent Cover - To be used with Marking Tag heets. 1 CA7-FMP 100 CA7-FMC ee page A54 Tag Carrier - For marking with eries V7 Clip-on Tags. 100 CA7-FM Minimum order quantity is one package of 100. Price each x 100 = total price. Previously catalog number 26.506.2-01. N014 Discount chedule 1 33

Technical Information eries RZ7-F Electronic Timing Relays Technical Data Timing Characteristics (according to VDE 0435, Part 20) Timing ranges for RZ7-FM-A, B, C, D, E, F, I, & L (1s) 0.05 1 sec RZ7-FH (3s) 0. 3 sec (10s) 0.5 10 sec (1mn) 0.05 1 min (3mn) 0. 3 min (10mn) 0.5 10 min (1h) 0.05 1 hour (3h) 0. 3 hours (10h) 0.5 10 hours (60h) 3 60 hours RZ7-FQ (2.5s) 0. 2.5 sec (10s) 0.5 10 sec (80s) 4 80 sec (10mn) 0.5 10 min etting accuracy ±5% of full scale value Repeatability ±0.2% of the setting values Tolerance Voltage: ±0.001%/%Δ Temperature: ±0.025%/ C Power upply upply voltages 24 48VDC and 24 240VAC, 50/60Hz (multi voltage) 12VDC 24 240V AC or DC (universal voltage) 346 440VAC, 50/60Hz Voltage tolerance AC: -%... +10% DC: -20%... +20% Power consumption AC: 5VA at 240V DC: 0.5W at 24V Time energized 100% Reset time 50ms Voltage interruption 20ms without reset (supply voltage) Input Impedance Relay On: 3k-13k ohms Relay Off: 0.7k-4k ohms Cable length 250 meters (800 ft.) max. (supply voltage control) Pulse Control () Impulse duration 50ms (AC), 30ms (DC) Input voltage upply voltage range Input current 1 ma Max. Leakage Current 400 micro Amps Cable length max. 250 m (800 ft.) without parallel load between & max. 50 m (160 ft.) with load (<3kΩ) between & Outputs Type of outputs Relay contacts: hard silver Maximum admissible operating voltage Alternating current: 440VAC Dielectric Coil to contact Withstand 5,000 V Voltage witching capacity Current I th : (AC1) 8A (5A for RZ7-FQ) Power: 2000VA according to IEC947-5-1: 3A/440VAC (inductive load, AC14) 3A/250VAC (inductive load, AC) 1A/24VDC (inductive load, DC13) according to L 508: 1.5A/250VAC (B300) 3A/120VAC (B300) hort circuit resistance 10 A gl (fast blow fuse) Life expectancy (electrical) 4 million ops. at 1A/250VAC, cosϕ = 1 0.2 million ops. at 6A/250VAC, cosϕ = 1 1.5 million ops. at 1A/250VAC, cosϕ = 0.3 0.3 million ops. at 3A/250VAC, cosϕ = 0.3 0.5 million ops. at 6A/24VDC, resistive 2 million ops. at 4A/24VDC, resistive 2 million ops. at 0.2A/230VDC, resistive 1 million ops. at 0.4A/24VDC, L/R = 20ms 1 million ops. at 0.2A/110VDC, L/R = 20ms 1 million ops. at 0.1A/230VDC, L/R = 20ms Life expectancy (mechanical) 30 million operations eneral Data Insulation Characteristics EMC/Interference Immunity 2 kvac/50 Hz test voltage according to VDE 0435 and 6 kv 1.2/50 ms surge voltage according to IEC 947-1 between all inputs and outputs Performance of following requirements: - urge capacity of the supply voltage according to IEC1000-4-5: 4 kv 1.2/50 μs - Burst according to IEC 1000-4-4: 6 kv/ 6/50ns - ED discharge according to IEC 1000-4-2: - Contact 8 kv, air 8 kv - Electromagnetic HF field according to IEC 801-3 and conducted electromagnetic HF signal according to IEC 801-6: Level 3 Electromagnetic fields according to EN 55 022: Class B EMC/Emission afe isolation According to VDE 106, part 101 Climatic withstand 56 cycles (24h) at 25 40 C and 95% relative humidity according to IEC 68-2-30 and IEC 68-2-3. Vibration resistance 4 g in 3 axis at 10 500 Hz, test FC according to IEC 68-2-6 hock resistance 50 g according to IEC 68-2-27 Protection class Enclosure: IP40 IP30 (single function) Terminal: IP20 according to IEC 947-1 Weight 100g Approvals/tandards L File E14840, C-L up to 240VAC, CE Ambient temperature Open: 25 C +60 C Enclosed: 25 C +45 C torage 40 C +85 C Connections crew terminal - M3.5 for Pozidrive No.2, Phillips and slotted screws No.2 suitable for power screwdriver. Rated tightening torque - Wire ize - Finger Protection - According to VDE 0106 Mounting Relays Disposal 0.8 Nm (max. 1.2 Nm) - [8.8 lb-in] Dual-chamber system for terminal cross-sections of 1 x 0.5mm 2 (solid) or 2 x 2.5mm 2 (flexible with sleeve), AW 20 14. nap-on mounting (35mm DIN-rail) ide mounting on CA7contactors and C7 with dovetail joint [surface mounting in any position] crew fixing by Panel Mount Adapter and two screws (M4) [surface mounting in any position] ynthetic material without dioxin according to EC/EFTA notification No. 93/0141/D. Electrical contacts contain cadmium. tandards EN 60947-1, EN 60947-5-1, EN 50081-1, IEC 947, L 508. CA 22.2 No. 14 RZ7 Relative cale etting Knob eries have a relative scale setting knob numbered 0 to 1.0. Think about this as 0 to 100% of the relay s built-in time range. Example: To set an RZ7-F timing relay (with a 0.05 to 1 minute range) to activate after 25 seconds: 1) Divide the desired activation time (25 seconds) by the maximum time limit of the relay (60 seconds). 25 60 =.416 2) Rotate the setting knob to just past the.4 mark. 34 Discount chedule 1 N014

Dimensions eries RZ7-F Electronic Timing Relays eries RZ7-F Timing Relays (one and two pole) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. RZ7-F (1 PDT contact) Panel Mount Adaptor (RZ7-FA) 22,5 13 RZ7-F (2 PDT contacts) 17 12 35 58 75 4,3 9 4,3 2 5,5 N014 Discount chedule 1 35