OSA 5548C BITS/TSG Timing Signal Generator

Similar documents
The TimeHub 5500 System

DTS 4210.timecenter. High precision time server, grandmaster and PRC

Modular Master Clock!

DTS 4160.grandmaster. Swiss Time Systems. High precision time server, grandmaster and PRC

RME-V01. Digital Instruments. Time and Reference Measurement System

Synchronisation Supply Unit for PDH & SDH networks

TimeSource Enhanced PRTC Enhanced Primary Reference Time Clock

GILLAM-FEi US4G. Synchronisation Supply Unit Network Clock Distributor. for PDH & SDH networks PRODUCT SPECIFICATIONS

Application Note. Re-timing: Cost-effective Synchronization via Re-timed E1 and DS1 Signals. Precision, Stability, Innovation, Support.

KHUSHI COMMUNICATIONS

Packet-Based Primary Reference Source for Synchronizing Next Generation Networks

Kyland Technology Co., Ltd. White Paper KT/ZY-RD Kyland Technology Co., Ltd. White Paper. High Precision Time Synchronization

Network expansion. Economic approach to distribution of synchronisation references to network elements. Introduction

OSA 5410 Series. PTP grandmaster, GNSS receiver and sync probe. Your benefits

WECC Guideline Digital Circuits Synchronization

LANTIME M3000: Time and Frequency Synchronization Platform

IMS - LANTIME M500: Time and Frequency Synchronization in Rail Mount Chassis

ALIANT OMMUNICATIONS. VCL-MegaConnect-Jr. 16 Port E1/T1 Mixed Configuration DACS and Interface Converter

Options for Mitigating Potential GPS Vulnerabilities

A.1 Cisco ONS CL Shelf Specifications. This section includes hardware and software specifications.

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

ALCATEL-LUCENT 9500 MICROWAVE PACKET RADIO RELEASE 3 ANSI

Loop-O9330 Fiber Optical Mux

SyncServer S250. GPS Network Time Server with Timing Enhancements

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Traditional Synchronization Standards Overview

TCG 01-G & TCG 02-G Firmware Release Notes

TimeProvider 4100 Precise Timing Gateway Clock

V C ALIANT OMMUNICATIONS. VCL-EC E1 Echo Canceller 1U, 19 inch Version with Telnet E1, 1U Echo Canceller Product Brochure & Data Sheet

VCL-TP, Teleprotection Equipment with Trip Counter Display

PHYSICAL LAYER TIMING

V C ALIANT OMMUNICATIONS. 4 x Ethernet over T1 (IP over TDM) Data Sheet & Product Brochure U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

SyncServer S250 S250 NETWORKING EXCELLENCE. Examples of Network Timing Configurations

Integration of the module is easily facilitated with the included SDKs/drivers for 32/64 bit Windows and Linux, and 64 bit Solaris.

Kyland solution for IEEE1588 Precision Time Synchronization in Electric Utilities

The SyncServer S250 is your answer to bringing perfect timing to your network.

VCL-TP, Teleprotection Equipment

SyncServer S200. Enterprise Class GPS Network Time Server

Application RTU560 RJ45 RJ45. Management. Switch RJ45 RJ45. Switch 560NMS34 SDSL. Data Sheet Switch 560NMS34. Port 1. Port 2. Port 3.

LANTIME M600: High End NTP Time Server

GPS IRIG-B/NTP Time Server GPS-2-E-NTP

LANTIME M300: NTP Server in 1U Case for Server Rackmount

IMACS 600, 800, 900 and Integrated Solution for Advanced Voice and Data

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

xgenius Cutting edge Transmission & synchronization Tester

RION ORION TELECOM NETWORKS INC. VCL-EC T1 Echo Canceller 1U, 19 inch Version with Telnet. T1, 1U Echo Canceller Product Brochure & Data Sheet

Best Practices for IEEE 1588/ PTP Network Deployment

Precise time Event Interrupts Alarm interrupts (time compare/strobe)

bc635pci-v2 PCI Time & Frequency Processor KEY FEATURES IRIG A, B, G, E, IEEE 1344, NASA 36, XR3 & 2137 Time Code Inputs and Outputs Simultaneous AM o

Traverse System Documentation. Installation and Commissioning Guide

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

Cisco ONS CL Shelf Assembly Hardware

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

VIPEDIA-12. Cameo specification sheet. Product Description

in Synchronous Ethernet Networks

NETWORK SYNCHRONIZATION TRAINING COURSE

Features. Overview DATA SHEET IMACS 3000

The SyncServer S350 is your answer to bringing perfect timing to your network securely, reliably and easily and for many years to come.

DESCRIPTION. Features

xgenius Cutting edge Transmission & Synchronization tester

The SyncServer S350 is your answer to bringing perfect timing to your network securely, reliably and easily and for many years to come.

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Optimux-4T1 Four-Channel T1 Multiplexer

IEEE 1588 Packet Network Synchronization Solution

6GK6022-8AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

Prisma II Platform. Optoelectronics

ORION TELECOM NETWORKS INC. VCL-XC

extended Transport Analysis Application Jitter and Wander Option

Loop-IP6700 TDMoEthernet

PTP650 Synchronous Ethernet and IEEE1588 Primer

LOOP-O 9100 STM1 ADM/TM

ISO 9001:2000 Certified Company

Testing Timing Over Packet With The Ixia Anue 3500

Timing in Packet Networks. Stefano RUffini 9 March 2015

Multilink. Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets. Multilin

TM2000A. PTP and NTP Time Server GPS Time Sourced. Installation and Operation Manual

Gmux Modular TDMoIP Gateway FEATURES

IPmux-14. TDMoIP Gateway FEATURES DESCRIPTION

LTC 8900 Series Allegiant Video Switcher/Control Systems

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

IPmux-1E. TDMoIP Gateway FEATURES

V C ALIANT OMMUNICATIONS. VCL-Ethernet over DS3 Switch (Ethernet to DS3 Switch) Product Brochure & Data Sheet

This document provides information about Cisco NCS users and node timing. The document contains the topics mentioned below.

Cisco Prisma II Platform

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05

LANTIME M600/GPS/PTP: PTPv2 / IEEE Grandmaster Clock and NTP Time Server with integrated GPS radio clock

Loop-O 9300 Fiber Optical Mux

Turn Up a Node. Before You Begin CHAPTER

Your Network. Optimized.

Alcatel 7515 Media Gateway. A Compact and Cost-effective NGN Component

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

SM Cirius LM 175/200+ Mbps Ethernet + 16 T1/E1

Introduction. Node Timing Parameters. Revised: June 5, 2017, OL This document provides information about Cisco NCS users and node timing.

FLASHWAVE 4100 Multiservice Provisioning Platform

Telecom Point to Point Radio

Reference Access and Interconnection Offer

Modeling technique and a simulation tool for analysis of clock synchronization in communication networks

Evaluating the performance of Network Equipment. Presenter: Tommy Cook, CEO Calnex Solutions Ltd

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

SpectraComm Quick Reference

Transcription:

OSA 5548C BITS/TSG Timing Signal Generator Features Unique design for Master, Expansion and Remote shelves Entirely new family of TSG with 3U and 6U shelves Adapts to all telecom node sizes, from a few 10 s up to 1000 s of Synchronization Intuitive and modular architecture (A&B groups, visual display of selected channels) Extremely compact: up to 200 DS1 or CC protected or unprotected in a 6U shelf Single System (Master and 4 expansions) allows up to 1000 protected Stratum 1 PRS with optional GPS card(s) Choice of Stratum 2 or Stratum 3E holdovers Universal input card design (DS1, CC, 5/10MHz) Universal output card design (DS1, CC) SSM on complete system (Master, Expansion, Remote) TL1 manageable with Local and Remote intuitive Graphical User Interface Up to 80 retiming channels Optional NTP and IRIG-B output blades The 5548C Timing Signal Generator (TSG) is designed to provide telecom operators with reliable synchronization, using the latest in hardware and software technologies. The 5548C system provides a scalable synchronization solution ranging from 20 unprotected up to thousands of 1:1 protected. Unparalleled flexibility The 5548C can be a Stratum 1 redundant source if you decide to include one of two possible GPS cards (this does not change the number of inputs or available). In addition to DS1 and Composite Clock (CC) output cards, any of the 10 main output slots can be equipped with time distribution modules (NTP or IRIG-B) or with DS1 retiming cards. With it s complete and consistent family (6U: 200, 3U: 60, expansions, ), the 5548C is the TSG of choice when you need scalability and reduced spare parts inventory. This flexibility makes the 5548C the most versatile TSG in the marketplace.

Extreme Compactness Each card is only 4 inches tall, contributing to a higher overall port/volume ratio, and therefore reducing the size of the 5548C 6U shelf design to accommodate overcrowded Telecom Hub Rooms and Switching Center rack spaces. High Availability All cards are intelligent and communicate with each other to implement a distributed intelligence message passing system. This approach ensures absence of single points of failure and reliable uptime. Inputs The 5548C TSG uses a universal Input Card (INC) designed to reduce spare count. Each input card can accept up to four signals and can be 1:1 protected with an adjacent identical B card. Two input groups (four slots) are available for Input Cards, giving flexibility from 4 unprotected inputs (one card) to 8 protected inputs (4 cards). GPS Modules* In addition to line input card, one or two GPS input cards can fitted to meet Stratum 1 requirements without the need of installing and managing external receiver(s) or Cesium clock. This allows the simplification of the sync plan by flattening the sync distribution hierarchy and results in a reduction of the overall provisioning, operating and maintenance costs. The presence of GPS input also gives access to precise time information that can distributed via NTP or IRIG-B. Additionally, 5548C can accept any external GPS reference as one on the input Line of the INC. Input Selection The active reference input is selected among the set of eligible input signals based on one of the following criteria: Priority table SSM value Performance Threshold mask User selection Tracking & Holdover This card forms the beating heart of the OSA 5548C TSG. The input reference jitter and wander are filtered by a high quality oscillator with DDS technology. Rubidium (Rb) Double Oven Quartz (OCXO)

Pass-through In the extreme case of total failure of both oscillator cards or if they are pulled out, the pass-through feature of the 5548C TSG still keeps the office alive. In this case synchronization is obtained from one input reference of the first INC s group and distributed without filtering to the INC s output section. Outputs The 5548C TSG uses a universal Output Card of 20 that will configure itself automatically (20 DS1, 20CC or 10 DS1 & 10CC) when detecting the output tile set. Output cards slots are, like all the other functionalities on this TSG, separated in intuitive A and B groups (adjacent cards slot). The 5548C 6U TSG counts 10 groups of, giving you the flexibility from 20 unprotected to 200 protected on one shelf (and the flexibility of having some protected and some unprotected). Performance Measurement All active inputs are constantly measured against the current output reference with 1ns resolution. The local processing of performance data presents the data in a way that reduces network overhead for remote retrieval. The computed MTIE and TDEV curves are used internally for the input selection compared to standard masks to raise alarms if the curves are out of limits sent to the management station(s) for display, user validation, and storage. Time Code Units (TCU)* Time Code Units (TCU) allow precise time distribution when at least one GPS card is installed. This is a major advantage compared to having to additionally install and manage an external receiver with its GPS antenna and cabling. Two kinds of Time Code Units output cards are available: TCU-NTP and TCU-IRIG-B. The NTP card provides full NTP server functionality on a separate 10 BaseT RJ-45 connector. The IRIG-B card provides four IRIG-B signals (two 1 khz AM, two DC level shift) on BNC connectors. Time output cards can be fitted into any main output card slot. Re-Timing* Each re-timing card provides 8 DS1 re-timing channels and the card occupies only one output card slot. Configurable alarm thresholds can be set via management software in terms of slips per hour/day/week. This allows continuous monitoring and immediate detection of synchronization problems on the incoming traffic signals and results in a higher Quality of Service..Expansion or remote shelves* Up to 4 expansion shelves can be chained to the main shelf for a total of 1000, optionally protected 1:1. Chaining of the expansion shelves is redundant in order to ensure maximum reliability.

Management The management card provides connectivity with local and remote synchronization management systems via a TL1 interface over RS-232 (local) and TCP/IP (remote). OSA Local Manager and SyncView Next Generation Management software provide, locally and remotely, powerful fault, configuration, accounting/inventory, performance and security management functions through an intuitive graphical user interface. Local alarm information is provided as: Internal buzzer (audible) Relay contacts (electrical) Status LED s on front panel (visual) Third party equipment can easily be managed through a set of 10 electrical alarm collection inputs; a specific user-configurable alarm message can be associated to each alarm input. As a future option, the 5548C will also be manageable directly by SNMP with embedded agent. Simplified Maintenance TSG and Expansion Shelves share the same cards; this reduces homologation activity, stock of spare parts as well as overall administrative complexity and results in reduced cost of ownership. All cards are easily reprogrammable via a simple software download and managed via a global shelf release.

OSA 5548C TSG Specifications Overall Architecture 5548C 6U TSG main shelf: 8 inputs + 2 GPS receivers, 200 5548C 3U* mini TSG main shelf: 4 inputs + 2 GPS receivers, 60 Up to 4 Expansion Shelves per main shelf, 200 each for 1000 total (dedicated redundant communication bus between master and expansion shelves). Remote shelves can also be connected, using CC or DS1 in order to propagate correctly the Bytes alignment (CC signal) or the SSM (DS1 signal). This allows a virtually unlimited output capacity. All cards can be protected 1:1 Re-timing Re-timing modules take same slots as main output modules 8 DS1 traffic carrying signals per module Up to 80 re-timed DS1 signals on TSG Configurable alarm thresholds in slips per hour/day/week Protection with by-pass relay Inputs Up to 8 line inputs in 6U TSG (4 in 3U mini TSG), optionally 1:1 protected, 4 inputs/ module Input types: DS1, CC, 5 MHz, 10 MHz individually SW-selectable Up to 2 GPS inputs, active L1 antenna, 1575.42 MHz DS1 inputs can be terminated, terminated 20dB or bridged (high impedance) Management Status LED s on front panel Contact relay alarm closures (2x3 N.O. or N.C. contacts) Electrical alarm collection inputs(10),specific user-defined alarm messages Local RS-232 port, TL1 protocol on front and rear panel Remote 10 BaseT Remote management via OSA SyncView New Generation Synchronization Management software supporting full FCAPS capability Input Selection Priority table SSM value Performance Threshold Mask Manual selection Performance Measurement Phase measurement on all inputs, GPS included 1ns resolution MTIE, TDEV, Ym curves computed locally Alarm thresholds, user settable Tracking and Holdover DDS-based Tracking & Holdover functionality Stratum 1 reference with embedded GPS (or external Cesium) source Stratum 2 based on Rubidium holdover <2e- 12/day (at 25 C) Stratum 3E based on OCXO SC-P3 holdover <1e-10/day (at 25 C) Expansion Shelves* Up to 200 per shelf, optional 1:1 protection Up to 4 Expansion Shelves for a total of 1000 per node (dedicated redundant communication bus between master and expansion shelves) Power 5548C TSG: -48 VDC power (-40 to 60 VDC) Power cards are redundant and user changeable Current: master shelf 6A max Outputs 20 per module (2 groups of 10) Up to 200, optionally 1:1 protected, on 5548C TSG Output type configurable by group of 10 Simplified Maintenance Universal Input and universal Output cards Upgrade of all cards via SW download Dynamic inventory data accessible via management SW All cards software included in the same system release Time Code Outputs* Up to 10 Time Code cards on TSG NTP, SNTP v4 (RFC 2030) Each time distribution module occupies one main output slot PTP - IEEE 1588 v2 on demand Mechanical 5548C 6U TSG: 19 /6U rack: 10.5 H x 19.0 W x 9.7 D 5548C 3U* mini TSG: 19 /3U* rack: 5.25 H x 19.0 W x 9.7 D Standards compliance ANSI T1.101 and T1.403 Telcordia GR-2830/1244/378/253-CORE NEBS, CE Standards compliance (continued) IETF RFC 2030 (SNTP v4), RFC 1305 (NTP) ITU-T G.703, G.811, G.812, G.704, G.781 ETSI EN 300 462-6, -4