Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors and Multi-pole, Square Connectors are standard. Terminal blocks available with either M or M screws. Connecting Cables for Programmable Controllers available (sold separately). Ordering Information Connectors Flat Cable Twin-connector Type Connector No. of poles Appearance Model M screws M screws M screws Flat Cable Connectors * 0 XWB-0G XWB-G 0 XWB-0G XWB-G 60 XWB-60G 0 XWB-0G5 XWB-G5 0 XWB-0G5 XWB-G5 60 XWB-60G5 0 XWB-0G5-T Daisy Chain 0 XWB-0G5-D Multi-pole, Square Connector M screws M screws Multi-pole, Square Connector Plugs * Multi-pole, Square Connector Plugs * 0 XWB-0Y XWB-Y XWB-Y 0 XWB-0Y5 XWB-Y5 XWB-Y5 0 XWB-0X5 XWB-X5 XWB-X5 Board I/O M screws Multi-pole, Square Connector Plugs * 0 XWB-0F5-P *. Flat Cable Connectors have one polarity slot. *. These Plugs and Sockets are made by Honda Tsushin Kogyo. *. These Plugs are made by Fujitsu. Accessories (Order Separately) Connecting Cables for Connector- Conversion Units For details on the Connecting Cable used between XWB Daisy Chain-type Connectors, refer to the XWZ datasheet.
Ratings and Specifications XWB Type XWB-@@G@ Item Flat Cable Units Rated current A Rated voltage 5 VAC Insulation resistance 00 MΩ min. (at 0 VDC) Dielectric strength Ambient operating temperature 0 VAC for min (leakage current: ma max.) 0 to 55 C XWB-@@Y@ Multi-pole, Square-connector Units XWB-0F5-P Board I/O Unit (Unit: mm) Flat Cable Units with a with M Screws XWB-@@G Wiring Diagram Flat Cable Connector Triangular mark Model Note: All pins on the Flat Cable Connector correspond -to- to the terminal of the same number on the terminal block as shown above. XWB-0G XWB-G XWB-0G XWB-G XWB-60G *. Either the XG5M-@@-N or the XG5M-@@5-N may be used. *. Each Connector requires two Semi-covers. N- N- N- N- N N- N- N 9.5 (order separately) Flat Cable Connectors, MIL Sockets with Discrete-wire IDC Connectors, Double-row Sockets Strain Reliefs Connectors * Semi-covers * XGM-00-T XGM-0-T XGM-00-T XGM-0-T XGM-600-T 5.08 Flat Cable Connector (MIL Plug) A XG5M-0-N XG5M-05-N XG5M--N XG5M-5-N XG5M-0-N XG5M-05-N XG5M--N XG5M-5-N XG5M-60-N XG5M-605-N 5.5 dia. 0.5 *Flat Cable Connectors have one polarity slot. Note: Terminal block pitch is 5.08 mm. Use a wire size between 0. and.5 mm (AWG to AWG6). The wire insertion holes are.8.5 (H W) mm. 5 8. (5.) Model No. of poles Dimension A (mm) Applicable Connector models * XWB-0G 0 6.5 XGA-0 XWB-G.5 XGA- XWB-0G 0 5.0 XGA-0 XWB-G 5.5 XGA- XWB-60G 60 80.0 XGA-60 XG5S-00 XG5S-0 XG5S-00 XG5S- XG5S-00
XWB Flat Cable Units with a with M Screws XWB-@@G5 Flat Cable Connector (MIL Plug) 9.5 5.5 5 dia. 8.5. Terminal Block Wiring Diagram Flat Cable Connector Triangular mark Model Note: All pins on the Flat Cable Connector correspond -to- to the terminal of the same number on the terminal block as shown above. XWB-0G5 XWB-G5 XWB-0G5 XWB-G5 XWB-60G5 *. Either the XG5M-@@-N or the XG5M-@@5-N may be used. *. Each Connector requires two Semi-covers. N- N- N- N- N N- N- N *Flat Cable Connectors have one polarity slot. Note: Terminal block pitch is 8.5 mm. (order separately) Flat Cable Connectors, MIL Sockets with Discrete-wire IDC Connectors, Double-row Sockets Strain Reliefs Connectors * Semi-covers * XGM-00-T XGM-0-T XGM-00-T XGM-0-T XGM-600-T XG5M-0-N XG5M-05-N XG5M--N XG5M-5-N XG5M-0-N XG5M-05-N XG5M--N XG5M-5-N XG5M-60-N XG5M-605-N Model No. of poles Dimension A (mm) Applicable Connector models * XWB-0G5 0.5 XGA-0 XWB-G5 80.0 XGA- XWB-0G5 0 0.5 XGA-0 XWB-G5.5 XGA- XWB-60G5 60 9.5 XGA-60 XG5S-00 XG5S-0 XG5S-00 XG5S- XG5S-00 (5.) 0.5
XWB Twin-connector Units with a with M Screws XWB-0G5-T 0.5 Flat Cable Connector (MIL Plug: XGA-0 ) 9.5 5.5 5 dia. 8.5..8 (5.) Wiring Diagram Flat Cable Connector Triangular mark Model XWB-0G5-T Triangular mark *. Either the XG5M-@@-N or the XG5M-@@5-N may be used. *. Each Connector requires two Semi-covers. 0 9 Note: All pins on the Flat Cable Connector correspond -to- to the terminal of the same number on the terminal block as shown above. 9 0 8 8 0 9 9 (order separately) Flat Cable Connectors, MIL Sockets with Discrete-wire IDC Connectors, Double-row Sockets Strain Reliefs Connectors * Semi-covers * XGM-00-T 0 XG5M-0-N XG5M-05-N 0.5 XG5S-00
XWB Daisy Chain Units with a with M Screws XWB-0G5-D 9.5 Flat Cable Connector (MIL Plug: XGA-0 ) 5 5.5 5 dia. 8.5. Wiring Diagram Flat Cable Connector Triangular mark Model XWB-0G5-D 0 9 Triangular mark 9 Note: All pins on the Flat Cable Connector correspond -to- to the terminal of the same number on the terminal block as shown above. *. Either the XG5M-@@-N or the XG5M-@@5-N may be used. *. Each Connector requires two Semi-covers. 9 0 0 (order separately) Flat Cable Connectors, MIL Sockets with Discrete-wire IDC Connectors, Double-row Sockets Strain Reliefs Connectors * Semi-covers * XGM-00-T XG5M-0-N XG5M-05-N.8 (5.) 0.5 XG5S-00 5
XWB Multi-pole, Square-connector Plug Units with a with M Screws XWB-@@Y A 9.5 Multi-contact Connector (Plug) 5.5 dia. 5 5.08 Wiring Diagram (Example for Terminal Block with Poles) 0.5 8. Multi-contact, Square Connector Model * Hood * XWB-0Y XWB-Y XWB-Y 9 Note: All pins on the Multi-pole, Square Connector correspond -to- to the terminal of the same number on the terminal block as shown above. 5 6 MR-0F (soldered) MRP-0F0 (crimped) * MR-0FW (wrapped) MR-F (soldered) MRP-F0 (crimped) * MR-FW (wrapped) MR-F (soldered) MRP-F0 (crimped) * MR-FW (wrapped) MR-0L MR-L MR-L *. All applicable Connector Hoods are made by Honda Tsushin Kogyo. *. Use MRP-F or MRP-F0 crimp terminals made by Honda Tsushin Kogyo. 8 9 6 8 9 8 8 9 Model No. of poles Dimension A (mm) Applicable Connector models * XWB-0Y 0 6.5 MR-0RMD XWB-Y.5 MR-RMD XWB-Y 5.5 MR-RMD *These Connectors are made by Honda Tsushin Kogyo. Note: Terminal block pitch is 5.08 mm. Use a wire size between 0. and.5 mm (AWG to AWG6). The wire insertion holes are.8.5 (H W) mm. 6
XWB Multi-pole, Square-connector Plug Units with a with M Screws XWB-@@Y5 Multi-contact, Square Connector (Plug) A 9.5 5.5 5 dia. 8.5. Wiring Diagram (Example for Terminal Block with Poles) Multi-contact, Square Connector Model * Hood * XWB-0Y5 XWB-Y5 XWB-Y5 9 Note: All pins on the Multi-pole, Square Connector correspond -to- to the terminal of the same number on the terminal block as shown above. 5 6 MR-0F (soldered) MRP-0F0 (crimped) * MR-0FW (wrapped) MR-F (soldered) MRP-F0 (crimped) * MR-FW (wrapped) MR-F (soldered) MRP-F0 (crimped) * MR-FW (wrapped) MR-0L MR-L MR-L *. All applicable Connector Hoods are made by Honda Tsushin Kogyo. *. Use MRP-F or MRP-F0 crimp terminals made by Honda Tsushin Kogyo. 8 9 6 8 9 8 8 9 Model No. of Dimension A Applicable Connector poles (mm) models * XWB-0Y5 0.5 MR-0RMD XWB-Y5 80.0 MR-RMD XWB-Y5.5 MR-RMD *These Connectors are made by Honda Tsushin Kogyo. Note: Terminal block pitch is 8.5 mm..8 0.5
XWB Multi-pole, Square Connector Socket Units with a with M Screws XWB-@@X5 Multi-contact, Square Connector (Socket) A 9.5 5.5 5 dia. 8.5. Wiring Diagram (Example for with Poles) Multi-contact, Square Connector Model * Hood * XWB-0X5 XWB-X5 XWB-X5 9 5 Note: All pins on the Multi-pole, Square Connector correspond - to- to the terminal of the same number on the terminal block as shown above. 6 8 9 MR-0M (soldered) MRP-0M0 (crimped) * MR-0MW (wrapped) MR-M (soldered) MRP-M0 (crimped) * MR-MW (wrapped) MR-M (soldered) MRP-M0 (crimped) * MR-MW (wrapped) MR-0L MR-L MR-L *. All applicable Connector Hoods are made by Honda Tsushin Kogyo. *. Use MRP-F or MRP-F0 crimp terminals made by Honda Tsushin Kogyo. 8 6 9 8 8 9 Model No. of poles Dimension A (mm) Applicable Connector models * XWB-0X5 0.5 MR-0RFD XWB-X5 80.0 MR-RFD XWB-X5.5 MR-RFD *These Connectors are made by Honda Tsushin Kogyo. Note: Terminal block pitch is 8.5 mm. 0.5.8 8
XWB Board I/O Units with a with M Screws XWB-0F5-P M.6 I/O Board Connectors (0-pin Plug) 0.5 9.5 5.5 5 dia. 8.5. 0.5.8 Wiring Diagram FCN-6P00-AU Plug Model * Hood * XWB-0F5-P B A FCN6J00-AU (soldered) FCN6J00-AAU (crimped) 9 9 8 0 0 9 0 FCN60C00- B Model No. of poles and Circuits * XWB-0F5-P 0 *These Connectors and circuits are made by Fujitsu. Note: Terminal block pitch is 8.5 mm. FCN-6P0-AU (Connector) FCN-60A (Anchor) *. All applicable Connectors and Covers are made by Fujitsu. *. Refer to the OMNUC U Series user's manual for details on the Connecting Cable used between the XWB-0F5-P and the U-series AC Servo Driver. 9
Safety Precautions XWB Precautions for Correct Use Wiring Always turn OFF the power supply before wiring. Otherwise, cables or other conductors can short the terminals and cause the Unit to fail. Do not connect or disconnect Connectors with the power turned ON. Otherwise, it may cause malfunctions. Wiring s Direct Wire Connections with a with M Screws. Use a wire size between 0. and.5 mm (AWG to AWG6).. Prepare the end of each wire as shown in the following diagram.. The wire insertion holes are.8.5 (H W) mm on the terminal block with M screws. Direct Wire Connections with a with M Screws Round. mm dia. Applicable crimp terminals Round Forked.5- -.5Y- (With a with M Screws) Round rod Dia. 6 mm 6.8 mm max. Forked Y- Blade W. mm 6.8 mm max. Applicable wires AWG to AWG6 (0.0 to.5 mm ) AWG6 to AWG (.5 to.0 mm ) AWG to AWG6 (0.0 to.5 mm ) AWG6 to AWG (.5 to.0 mm ) Terminal Screw Tightening Torque Select a tightening torque from the following table when connecting wires or crimp terminals to the terminal block. Tightening torque N m With M screws 0.0 With M screws 0.59 Mounting Units to and Removing Units from DIN Track For terminal blocks with M screws, use a flat-heat screwdriver like the one shown in the following diagram..9- to -mm blade Screw slot width: 0. XWB Connector- Conversion Units can be mounted side-to-side on DIN Track. The flanges for mounting screws are located on each side at the bottom of the XWB. Secure both ends of the XWB with End Plates. When removing the Unit from a DIN Track, insert a flat-head screwdriver into the slider and pull the lock out. Applicable crimp terminals Rod Blade t = 0.5 TC-05 Dia. = TC-.5S Dia. =.5 BT.5-9- BT.5-0- W =. Applicable wires AWG to AWG8 (0.0 to 0.5 mm ) AWG to AWG6 (0.0 to.5 mm ) AWG to AWG6 (0.0 to.5 mm ) Note: Round rod and blade crimp terminals are made by Nichifu. 0