Powerware 5125 UPS. Features

Similar documents
Powerware. > Expansion Chassis > Connectivity Cards: ConnectUPS-M SNMP (2) Web/SNMP/xHub USB Relay Modbus

Powerware 9120 UPS. Product Snapshot. Features

Powerware Software Connectivity Service. > Powerware Software Suite ensures data integrity; free updates on

Product Snapshot. The Powerware Uninterruptible Power System. Product Focus

Powerware 9125 UPS. Features. Fourth-Generation Online topology ensures continuous clean power

Powerware 9170 Online

Eaton 5125 UPS family

Product Snapshot. Powerware Online Uninterruptible Power System

5125 Family Uninterruptible Power System

Powerware P64

Eaton UPS. Product Snapshot. Powerware series

Powerware 9910-P11 and 9910-P16

9910 P18. Advanced power protection for mission-critical System p, System x, Storage and Networking rack products and applications. P18.

Product Snapshot. the Powerware Uninterruptible Power System. Double-conversion, online design offers superior reliability and protection

Powerware TVSS (Transient Voltage Surge Suppression) ZoneMaster, ZoneSentinel, ZoneDefender

Powerware kVA

Powerware 9 Prestige UPS

QuickSpecs. HP Tower UPS T750 G2, T1000 G3, T1500 G3 Overview

HP UPS R1500 XR. Overview

Rackmount Product Guide

R/T2000 G2 HP R/T 2200 UPS INTL HP R/T 2200 UPS JPN/TWN

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

T1000 G2 and T1500 G2 1. Battery Compartment 1. Battery Compartment 2. LED display 2. LED display HP T1500 UPS INTL HP T1500 UPS JPN/TWN

Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models. Overview. Retired

QuickSpecs HP T750 UPS. Overview

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

Powerware P95

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartPro UPS System Intelligent, line-interactive battery backup and network power management

SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

Model #: SU1500RTXL2U

UPS Emergency Bed Power Unit

Product Snapshot Features Power Rating: VA Voltage: 120, 208 and 230 Vac Double conversion online technology

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets

Power protection as easy as Contents

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

QuickSpecs. Models HP UPS R3000 XR. Overview

Product Specifications

ConnectUPS -X and -BD Web/SNMP Cards and the ConnectUPS Family

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack, USB, DB9 Serial, LCD

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

Premium Online Series

SmartPro 120V 1.5kVA 1.44kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, USB, 8 Outlets

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

Powerware kVA

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

Uninterruptible Power Supplies

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

SmartPro 120V 700VA 450W Line-Interactive Sine Wave UPS, Tower, 120 or 230V input, Network Card Options, USB, DB9

OmniSmart 120V 1400VA 940W Line-Interactive UPS, Tower, USB port

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial

Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V

Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out

SmartPro 1kVA 800W Line Interactive Sine Wave UPS, SNMPWEBCARD option, 1U Rackmount, USB, RS232, EPO, 120V

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

OmniVS 230V 1500VA 940W Line-Interactive UPS, Extended Run, Tower, USB port, C13 Outlets

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

QuickSpecs. HP R1500 G3 Uninterruptible Power Supply (UPS) Overview

Smart-UPS APC Smart-UPS 750VA USB & Serial 120V

SmartPro 120V 1kVA 900W Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, 8 Outlets

SmartOnline 208/230V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, SNMP Card Option, LCD, USB, DB9, ENERGY STAR

SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, V Hardwire output

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V

OmniVS 230V 1000VA 500W Line-Interactive UPS, Tower, USB port, C13 Outlets

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartOnline 120V 2.2kVA 1.8kW Double- Conversion UPS, Tower, Extended Run, Network Management Card Slot, LCD, USB, DB9

SmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial

QuickSpecs HP R3000 UPS. Overview

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

TAA-Compliant OmniVS 120V 1000VA 500W Line-Interactive UPS, Tower, USB port

TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower, Extended Run, SNMPWEBCARD Option, USB, DB9 Serial

Transcription:

Powerware 5125 UPS Features Advanced Battery Management Plus (ABM TM Plus) doubles battery service life Buck/Double Boost voltage regulation with pure sine wave output Load Segment control (separate receptacle groups) enable scheduled shutdowns and maximize run time for each critical devices Network Transient Protector isolates networks, modems and cables from surges and spikes X-Slot option modules that extend the UPSs power management capabilities Hot-swappable batteries simplify service Extended Battery Modules (EBMs) extend run time capability Complete offering of power management software included to ensure data integrity 2400/3000VA model increases uptime via hot-swappable electronics and battery module. Two-in-One rack and tower form factor provides versatility Triple Power Warranty (U.S. and Canada) - 10-Year Pro-Rated Warranty - 60-Day Money Back Guarantee - $25,000 Load protection Guarantee The Powerware 5125 provides advanced power management for PCs, workstations, and servers. Available in both rack-mount and tower configurations, the Powerware 5125 is the most flexible UPS in the 1 3 kva power range. Featuring capabilities often found in higher kva units, the 5125 has load segments which enable scheduled shutdowns and load shedding, and offers advanced communications with Powerware s complete power management Software Suite for extensive control and monitoring. The Powerware 5125 features Powerware s Advanced Battery Management Plus (ABM TM Plus), which doubles battery service life, critical to maximizing system availability. ABM Plus also minimizes recharge time and provides up to 60 days notification when the batteries are approaching the end of their useful life. When alarm notification indicates the end of battery life is near, the batteries can be easily hot-swapped without powering down the connected load. User friendly design allows batteries to be exchanged through the front of the unit. Product Snapshot Power Rating: 1000-3000 VA Frequency: 50/60Hz (auto-sensing) Voltage: 100-127 Vac; 200-240 Vac Configuration: Two-in-One form factor and tower The Powerware 5125 s design provides high power density, which conserves valuable space in rack, bench, bookshelf or floor appliances. All models are manufactured to ISO 9001 standards and meet or exceed worldwide specifications for safety, performance and excellence.

Powerware 5125 Features Series 5 Power Protection Two-in-One Form Factor Install the Powerware 5125 Two-in-One Models as either a tower or rack-mount UPS. Powerware Series 5 UPSs are most effective against five power problems (power failures, power sags, power surges, undervoltage and overvoltage) and offer a degree of protection against other power problems. Some of the damages you risk by not using a series 5 UPS include premature hardware failure, data loss and corruption, data error, keyboard lockup, storage loss and system lockup. PW5125 1000 shown with EBM. Up to 3000VA of UPS power is packed into only 2U (3.5 inches) of rack space. UPS EBM Power Failures Power Sags Power Surges Undervoltage The Powerware 5125 Two-in-One Form Factor packs the same technology of the Tower model into a compact design for standard 19-inch equipment racks or use as a stand alone unit. By limiting the rack height (2U) of the UPS, the Powerware 5125 saves room for other critical equipment such as servers and disk arrays. In addition, installable X-Slot option modules provide enhanced communication and scalable power protection for computer equipment. Overvoltage PW5125 1000 RM Shown Acting as a defensive barrier between your equipment and corrupted power, the Powerware 5125 eliminates the threats caused by power anomalies, thus increasing productivity and your bottom line. Series 5 UPSs are recommended for small network systems all the way up to enterprise networking environments. 2400VA and 3000VA models Front Panel Display Bad Battery/Low Battery General Alarm Utility LED On Off/standby On Battery Site Wiring Fault Indicator Load level LEDs Test/alarm reset Hot-Swappable Battery Moduleswhen batteries reach the end of their useful life, replace battery modules without powering down connected equipment Hot-Swappable Electronics Modulesreplace electronics modules without shutting down connected equipment

Software and Connectivity Options Powerware Software Suite The industry s most comprehensive software bundle, The Powerware Software Suite, is free and included with every Powerware 5125. Foreseer Facility & Data Center Management LanSafe III & CheckUPS Network Shutdown for UPSs Software Wizard guides you through software selection and installation. In addition to multimedia demonstrations, product data sheets, and video clips, the Software Suite contains the following power management software: LanSafe III & CheckUPS Network UPS shutdown software OnliNet SNMP-based network UPS shutdown and monitoring software PowerVision (30-day trial version) UPS performance analysis and monitoring software Foreseer (demonstration) facility and data center management software X-Slot Interface PowerVision UPS Performance Analysis & Monitoring SOFTWARE SUITE Powerware Software Suite OnliNet SNMP-Based Network Shutdown & Monitoring The Powerware 5125 has available connectivity options to suit nearly any communication requirement. RS-232 Single Serial Module (standard) for interface with power management software X-slot SNMP/web adapter module shown Rear Panels Tower Models SNMP/Web Module (optional) adds direct control and monitoring capabilities in SNMP-based networks. Ability to monitor UPS status and meters through web browser interface USB Module (optional) allows UPS to communicate with Windows 98 and ME computers Multi-Port Module (optional) six serial ports provides scalability by allowing you to attach multiple UPSs to a single network device Relay Module (optional) adds integration to industrial environment, building management systems, and shutdown capability for IBM AS/400 PW5125 1000/1500, 120V PW5125 2200, 120V PW5125 2200b, 208V PW 5125 1000i/1500i, 230V PW5125 2200i, 230V Two-in-One Models PW5125 1000i/1500i RM, 230V PW5125 1000/1500 RM, 120V PW5125 2400/3000 RM, 120V PW5125 2400i/3000i RM, 230V PW5125 3000g RM, 200-240V

Battery Features & Run times ABM Plus Doubles Battery Service Life Data based upon tests performed by an independent battery manufacturer. The lead-acid batteries typically used in a UPS are considered viable as long as they can maintain backup times of at least half that of new batteries. The illustratoin to the right shows that batteries that are constantly trickle charged (as are virtually all other UPSs on the market today) reach the end of their useful life in less than half the time of batteries charged using Advanced Battery Management Plus. ABM Plus uses a proprietary three-stage charging technique that not only doubles battery service life, but also optimizes recharge time and provides up to a 60-day advanced notification of the end of useful battery life. Load Segments, Network Transient Port and Remote Emergency Power Off (REPO) Port The Network Transient Protector isolates your modem, fax machine, and other electronic equipment from back door power surges. (1000-2200 VA models only) Shut down and power up Load Segments in user defined sequence Hot-Swappable Batteries You can hot-swap batteries without powering down the connected load on both tower and Two-in-One form factor models. This makes it possible to extend the life of your UPS without returning the unit for service. Extended Battery Modules (EBMs) Increasing battery backup time is as simple as plugging in an extended battery module. Hot-swap capability on all Powerware 5125 modules allows you to expand run time or replace battery modules while keeping your critical load up and running. Powerware 5125 shown with front cover removed and battery shown sliding out. Powerware 5125 Battery Run Time Chart (in minutes full load/half load)* VA Standard Internal Batteries 1 EBM 2 EBMs 3 EBMs 4 EBMs Tower Models 1000 5/14 25/60 55/170 83/199 109/228 1500 6/17 33/79 63/146 92/174 120/201 2200 5/14 26/60 55/170 81/198 106/224 Two-in-One Form Factor 1000 7/19 33/68 58/120 82/166 105/214 1500 5/13 23/57 49/161 73/172 96/205 2400 7/19 35/73 60/124 85/177 110/229 3000 5/15 25/61 49/103 69/146 90/190 * Up to 4 EBMs can be connected to 1000-3000VA models. EBM run times include internal batteries. Run time chart provides typical information. Battery run times are approximate and may vary with equipment, configuration, battery age, temperature, etc. Load Segments are groups of receptacles that can be independently controlled and extend battery backup times for critical equipment. To preserve battery power for more critical equipment. To preserve battery power for more critical equipment connected to Load Segment 1, shut down Load Segment 2 supporting less critical equipment The REPO port enables you to shut down the UPS and connected equipment from a remote location in an emergency.(two-in-one models only)

Technical Specifications 1 E LECTRICAL I NPUT 1000 2200 VA 2400 3000VA Nominal Voltage 120, 208 and 230 Vac; See Model Selection Guide for 120, 208, 230 and 240Vac; See Model Selection Guide user-selectable volages for user-selectable voltages Input voltage ranges for Low voltage: 77-152V; High voltage: 154-288V user-selectable voltages Operating Frequency 50/60Hz, Auto-sensing Frequency Range E LECTRICAL O UTPUT On Utility Voltage Regulation On Battery voltage Regulation Voltage Wave Shape (on battery) Output protection B ATTERY Battery Type Battery Run time Battery Replacement Recharge Time Start-On-Battery G ENERAL Diagnostics 46-65Hz -10% to +6% of nominal ±5% RMS Sine Wave Short circuit protection Sealed, lead-acid; maintenance free See Battery Run Time table Hot-swappable internal batteries and external batteries modules <3 hours to 90% usable capacity Allows start of UPS without utility input Full System self-test on power up UPS Bypass No Bypass Internal Bypass Transfer Time Dimensions and weights 2-4ms typical See Model Selection Guide Overload (normal operation) 110% overload, shutdown after 3 minutes. 110% overload for 30 seconds short circuit protected 150% overload, shut down 10 cycles C OMMUNICATIONS User Interface Front Control Panel Audible Alarms Network transient Protector REPO Port X-Slot Interface Cable Power Management Software E NVIRONMENTAL Safety Certifications For various UPS alarm conditions, including: On Battery, Low Battery, Overload, UPS fault UL 497 A, In/out jacks RJ45 (high voltage models network protection) & RJ11 (low voltage models modem protection) Meets NEC code 645-11 intent and UL requirements RS-232 Single Serial Module (standard), Other options available: RS-232 Multi-Port Module (6), SNMP/Web Module; USB Module; Relay Module 6-foot communications cable included Powerware Software Suite CD-ROM (bundled with UPS) UL; cul; NOM; C-Tick; CE mark EMC Compliance FCC Part 15, EN50091-2, Class A for 2.2KVA and RM; FCC Part 15, EN50091-2, Class A Class B for 1000 and 1500VA tower models Operating Temperature 0 to 40º C (32 to 104º F) Storage Temperature -15 to 50º C (5 to 122º F) Relative Humidity Lightning & Surge Protection Surge energy rating Audible Noise Altitude 0% to 95% non-condensing ANSI/IEEE C62.41 (IEEE 587), IEC61000-4-5 480 Joules Less than 40 dba typical 3000m (10,000 ft) without derating 1. Specifications are subject to change without notice due to continuing product improvement programs.

Powerware 5125 Model Selection Guide Model Power Rating Input/Output Input Output Dimensions Weight Number 1 (VA/Watt) Voltage (VAC) 2 Connection Receptacles 4 HxWxD (in/mm) (lb/kg) Tower Models (North America) PW5125 1000 1000/700 120 5-15P, (6) 5-15R 9.45 x 6.38 x 15.79/ 34.3/15.6 6 ft line cord 240 x 162 x 401 PW5125 1500 1440/1050 120 5-15P, (6) 5-15R 9.84 x 6.38 x 18.39/ 50.7/23.0 6 ft line cord 250 x 162 x 467 PW5125 2200 1920/1600 120 5-20P, (6) 5-15R, 9.84 x 8.07 x 19.41/ 68.3/31.0 6 ft line cord (2) 5-20R 250 x 205 x 493 PW5125 2200b 2080/1600 208 IEC-320-15A, (9) IEC-320-10A 9.84 x 8.07 x 19.41/ 68.3/31.0 inlet 3 250 x 205 x 493 Tower Models (International) PW5125 1000i 1000/700 230 IEC-320-10A, (6) IEC-320-10A 9.45 x 6.38 x 15.79/ 34.3/15.6 Inlet 3 240 x 162 x 401 PW5125 1500i 1500/1050 230 IEC-320-10A, (6) IEC-320-10A 9.84 x 6.38 x 18.39/ 50.7/23.0 Inlet 3 250 x 162 x 467 PW5125 2200i 2200/1600 230 IEC-320-10A, (9) IEC-320-10A 9.84 x 8.07 x 19.41/ 68.3/31.0 Inlet 3 250 x 205 x 493 Two-in-One Form Factor Models 5 (North America) PW5125 1000 RM 1000/900 120 5-15P, (6) 5-15R 3.5 x 17.0 x 19.4/ 34.0/15.0 12 ft line cord 89 x 432 x 494 PW5125 1500 RM 1440/1050 120 5-15P, (6) 5-15R 3.5 x 17.0 x 19.4/ 50.0/23.0 12 ft line cord 89 x 432 x 494 PW5125 2400 RM 2400/2250 120 L5-30P, (1) L5-30R, 3.5 x 19.0 x 24.5/ 101.0/45.8 12 ft line cord (6) 5-15R 89 x 482.6 x 622.3 PW5125 3000 RM 2880/2700 120 L5-30P, (1) L5-30R, 3.5 x 19.0 x 24.5/ 101.0/45.8 12 ft line cord (6) 5-15R 89 x 482.6 x 622.3 Two-in-One Form Factor Models 5 (International) PW5125 1000i RM 1000/700 230 IEC-320-10A, (6) IEC-320-10A 3.5 x 17.0 x 19.4/ 34.0/15.0 Inlet 3 89 x 432 x 494 PW5125 1500i RM 1500/1050 230 IEC-320-10A, (6) IEC-320-10A 3.5 x 17.0 x 19.4/ 50.0/23.0 Inlet 3 89 x 432 x 494 PW5125 2400i RM 2400/2250 230 L6-20P, (1) IEC-320-16A, 3.5 x 19.0 x 24.5/ 101.0/45.8 12 ft line cord (9) IEC-320-10A 89 x 482.6 x 622.3 PW5125 3000g RM 3000/2700 200-240 IEC-320-16A, (1) IEC-320-16A, 3.5 x 19.0 x 24.5/ 101.0/45.8 Inlet 3 (9) IEC-320-10A 89 x 483 x 622 PW5125 3000i RM 3000/2700 230 IEC-309-16A, (1) IEC-320-16A, 3.5 x 19.0 x 24.5/ 101.0/45.8 12 ft line cord (9) IEC-320-10A 89 x 483 x 622 Optional Extended Battery Modules (EBMs) PW5125 24V EBM Standard 9.84 x 6.38 x 18.66/ 59.5/27.0 1000VA tower models only Connector 250 x 162 x 474 PW5125 48V EBM Standard 9.84 x 6.38 x 18.66/ 59.5/27.0 1500/2200VA tower models only Connector 250 x 162 x 474 PW5125 48V EBM RM Standard 3.5 x 17.0 x 19.4/ 65.0/29.5 1000/1500VA RM models only Connector 89 x 432 x 494 PW5125 120 RM Standard 3.5 x 19.0 x 24.5/ 121.0/54.9 2400/3000VA RM models only Connector 89 x 483 x 622 1. 50/60 automatic frequency selection. 2. 120V models 110V, 120V, 127V user-selectable. 230V models 220V, 230V, 240V user-selectable. 208V models 208V 220V, 230V, 240V user-selectable 3. Includes (2) each IEC interconnect cables. 4. 1000-1500VA models divided into (2) Load Segments (receptacle groups). 2200-3000VA models divided into (3) Load Segments (receptacle groups). 5. Unit fits in standard 19- inch racks. Mounting kits are sold separately. Available Options Order Number Description 05141562-0021 4 post rack-mount kit (fits 19-inch racks) 05146726-5501 2 post rack-mount kit (fits 19-inch racks) 05146447-5501 X-slot multi-port module 05146508-5501 X-slot USB module To be announced X-slot relay module IPK-0330 X-slot SNMP/Web adapter module Invensys Power Systems 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.877.797.9273 or 919.872.3020 Fax: 1.800.753.9433 www.invensys-power.com 5125FXA Revised 08/01 Reprint 08/01 Europe/Middle East/Africa Berkshire, England: 44.1753.608700 Southeast Asia Singapore: 65-8610377 China and North Asia Hong Kong: 852.2745.6682 Japan Shinagawa Tokyo: 813.3447.5251 Australia and South Pacific Sydney, Australia: 612..9878.5000 Canada Toronto, Ontario: 416.798.0112 Brazil Sao Paulo, Brazil: 55.11.3933.8555/855.8500 Mexico Col. Napoles C.P., Mexico 525.527.61.69/ 525.488.33.33