Discover our 193nm excimer laser systems, incorporating Laurin Technic sample cells and GeoStar Software, for the very best in LA-ICP-MS.

Similar documents
Discover our 193nm excimer laser systems, incorporating Laurin Technic sample cells and GeoStar Software, for the very best in LA-ICP-MS.

Sample Introduction Systems SOLID LASER ABLATION

Sample Introduction Systems SOLID LASER ABLATION -II

Sample Introduction Systems SOLID LASER ABLATION -II

Sample Analysis Design

ION BEAM MILLING SYSTEM FOR TEM, SEM AND LM PREPARATION. Leica EM RES102

MPI TS150-THZ 150 mm Manual Probe System

MPI TS150-AIT 150 mm Manual Probe System

ACCURACY, SPEED, RELIABILITY. Turnkey Production for: MEMS. Multi-Chip Modules. Semiconductor Packaging. Microwave Modules.

A full description of the principles of the Matlab code used to produce the images is given below.

Because Frozen Sections are Vitally Important

OptoSLT nano. Preserve vision in record time

DESIGN AND IMPLEMENTATION OF LABVIEW TM BASED GUI FOR REMOTE OPERATION AND CONTROL OF EXCIMER LASER FOR PLASMA WAKEFIELD ACCELERATION EXPERIMENT

Thermo Scientific Spectronic 200 Visible Spectrophotometer. The perfect tool. for routine measurements

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

Progress of the Thomson Scattering Experiment on HSX

Technical Specifications for High speed PIV and High speed PIV-PLIF system

NANOMETRIC LAB PRINTER. Plug & Play Solution for ultra-precise printing of conductive lines in nano-scale

Precision Cutting of Printed Circuit Boards and Cover Layers UV Laser Cutting with LPKF MicroLine 2000 Systems

ksa MOS Ultra-Scan Performance Test Data

D-SCOPE The indispensable analysis tool for all diamonds

Chapter 3. Experimental Procedure

Increasing laser processing efficiency using multibeam and tailored beam profiles

The Perfect Fit for Over 40 Years

ProScan. High Performance Motorized Stage Systems

SPECTROTEST TEST. Metal analysis redefined. The New Standard for Performance and Flexibility

4800 Bondtester. Advanced Automated Wafer Testing.

Thermal Heads for Power and Single-Shot Energy - mw to KW, mj to 300J

Choice of Pumping Element Technology

Laser Micro-Fabricator. Innovative Laser Technology KORTherm Science

A U T O C O L L I M A T O R S

Spraybase Technical Specifications Sheet

Mu lt i s p e c t r a l

FLEXPOINT Laser Modules. Laser Modules For Your Application. laser-components.com

Laser Power Probes POWER PROBES OEM SOLUTIONS USB/RS232 SENSORS MONITORS & SW

VERTICAL CONTROL LASER OWNERS MANUAL

ONYX 32 MULTIFUNCTIONAL POSITIONING AND SOLDERING SYSTEM

ABM's High Resolution Mask Aligner Features:

Advancing Cancer Diagnostics Improving Lives. Leica RM2255. Rotary Microtome for High-Performance Motorized and Manual Sectioning

Short pulse laser milling effects on surface integrity. P V Petkov, S S Dimov, R. Minev and D T Pham

Beam Profilier - Beamage 3.0

Precision Cutting of Printed Circuit Boards and Cover Layers UV Laser Cutting with LPKF MicroLine 2000 Systems

SlicePlatform Fixed Platform System

TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING

SPIcam: an overview. Alan Diercks Institute for Systems Biology 23rd July 2002

TiTan Ion pumps (MINI - 75S) (100L LX) (150TV - 600TV)

LaserTower DESKTOP LASER MARKING AND ENGRAVING SYSTEM

Improvements in LA-ICP-MS for Trace Forensic Analysis of Common Household Products Using a Short Pulse Ultraviolet Laser

Spherical Crystal X-ray Imaging for MTW, OMEGA, and OMEGA EP

DC - Devices and Controller

Laser welding. New in the range Laser devices Accessories. Laser welding fillers

MegaPointe. MEGA bright with MEGA features and still compact. The MegaPointe from Robe. Light source Osram Sirius HRI 470 W RO

DRILLING SERIES MULTISTATION EVOLUTION LZ NEW HIGH SPEED MODULAR MICRODRILLING STATION

Particle Insight Dynamic Image Analyzer

Versatile laser Raman Spectrometer. RMP-500 series

Optics for nonlinear microscopy

MegaPointe. MEGA bright with MEGA features and still compact. The MegaPointe from Robe. Light source Osram Sirius HRI 475/5 W RO

Dia Lens Finishing Products & Accessories. The best solutions for your finishing laboratory. solutions

IX-280-MXF Dual Laser Machining

XCAM CCD Camera with e2v Technologies CCD42-90 or CCD44-82

nyloflex processing equipment

LBP2-SAM Series Beam Sampler for C-mount Cameras. User Notes

PatchStar Micromanipulator. Control. Productivity through control

Mass Flow Meters, Controllers and Manifolds

1.3 Customized Solutions (OEM)

Tutorial: Instantaneous Measurement of M 2 Beam Propagation Ratio in Real-Time

A New Generation of Reliability FOM2 NT. FO3015M2NT Laser Cutting System

Development of automated ultraviolet laser beam profiling system using fluorometric technique

The new 6300 Series. The new dual range

Chapter 2: Wave Optics

evue Digital Imaging System DATA SHEET FEATURES / BENEFITS

MPI TS150-HP 150 mm High Power Manual Probe System For accurate High Power measurements up to 10 kv, 600 A

Geometry Measurements

DL7S Profile. Light source 800 W 7 colours LED engine. Light output lm. Zoom range 7-43

Introduction of the Industry's Broadest Tunable Quantum Cascade Lasers. February Block Engineering 1

The location of the bright fringes can be found using the following equation.

MEXICO (52) NETHERLANDS (31) SINGAPORE (65) SOUTH AFRICA (27) / 5 SPAIN (34)

LaserTowerPRO CM 3D MARKING AND ENGRAVING SYSTEM. LaserTower COMPACT 3D LASER MARKING SYSTEM. LaserTower COMPACT 3D LASER MARKING SYSTEM

MPS50SL Miniature Mechanical-Bearing Screw-Driven Linear Stage

Complete Barrel Measuring and Inspection System. PS Series. User s manual

Versatile. Innovative. Customizable M CVAF Mercury Analyzer

LIGHT OUTPUT Beam mode: lm, m; Spot mode: lm, m

XT550. Intrinsically safe for potentially explosive environments. Shaft Alignment

NexGen Series FTS Combi

Next Generation In-House PCB Prototyping The New LPKF ProtoMat Circuit Board Plotters

Next Generation In-House PCB Prototyping The New LPKF ProtoMat Circuit Board Plotters

TABLE OF CONTENTS PRODUCT DESCRIPTION VISUALIZATION OPTIONS MEASUREMENT OPTIONS SINGLE MEASUREMENT / TIME SERIES BEAM STABILITY POINTING STABILITY

Effiziente Designverfahren für optische Laser- und Beleuchtungssysteme

HIE ISOLDE ALIGNMENT AND MONITORING SYSTEM TECHNICAL DESIGN AND PROJECT STATUS

XT550. Intrinsically safe for potentially explosive environments. Shaft Alignment

MPS75SL. Miniature Mechanical-Bearing Screw-Driven Linear Stage. Compact 75 mm width, with travel to 100 mm. Precision ground ball-screw drive

Beam Position Monitor For High Energy Particle Beams

MPI TS2500-RF 200 mm Fully Automated Probe System For RF Production Test Measurements

Stress-Free Depaneling of Assembled Boards LPKF MicroLine 6000 S

Dual Fiber SWIR Laser Doppler Vibrometer

Acoustic, Vibration, and EMI Isolation Specialists. AVI-600 Series

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

AVI-400 Series. Overview. Acoustic, Vibration, and EMI Isolation Specialists.

VibroFlex Compact Compactness meets versatility Preliminary datasheet. VibroFlex Compact

Transcription:

Discover our 193nm excimer laser systems, incorporating Laurin Technic sample cells and GeoStar Software, for the very best in LA-ICP-MS. www.asi-pl.com.au email resolutionsales@asi-pl.com.au

The RESOlution 193nm excimer laser ablation systems are a robust design, offering an industry leading Laurin Technic sample cell and pioneering GeoStar μgis TM software. Incorporating the latest in excimer laser technology for longest laser life, increased optical performance and minimal laser maintenance. S155 Ablation Cell The Laurin Technic laser ablation cell was developed by Mike Shelley, formerly of the ANU. Its design incorporates many sophisticated features that combine to deliver excellent results. The S155 is the only constant volume, dualvolume sample cell available on the market. This unique design ensures that your sample reaches the ICP as quickly and efficiently as possible. Published results demonstrate that this cell delivers: Fast washout times Outstanding signal sensitivity Highly uniform signal across the entire cell Minimal fractionation The S155 Laurin Technic laser ablation cell incorporates the same advanced features as the earlier M50A sample cell, with over six times the accessible area. Movement range of 155mm x 105mm Mount up to 20 standard 1 mounts Mount up to 6 full-size thin section slides No performance compromise

Samples in the cell are imaged using a motorised off-axis viewing system and a high resolution camera, all effortlessly controlled via our GeoStar software. All gas controls are completely automated, making sample exchanges easy and safe for the torch. Gas operations are customised to specific ICP requirements using a powerful scripting language. To assess how this cell will revolutionise your research, please consult the reference below or contact us for more information. Müller W et al., Initial performance metrics of a new custom-designed ArF excimer LA-ICPMS system coupled to a two-volume laser-ablation cell, JAAS 24, (2009), 209-214, (DOI: 10.1039/B805995K) S155 Flexible Mounting Options Combination holder for 30mm & 40mm round mounts Universal holder for arbitrarily-sized objects, thin sections and round mounts The S155 sample cell includes three (3) sample holders as standard. These can be chosen from a wide selection including a universal holder, all thin sections, all round mounts, or a combination of the two. Combination holder for thin sections and round mounts The universal holder is the most versatile and flexible holder available and can handle arbitrarily sized objects, while ensuring they present a flat surface to the incident laser beam. Additional holders are designed to accommodate thin section slides with widths of 25mm (1 ), 28mm or 30mm, and epoxy round mounts with diameters of 12mm, 25mm (1 ), 30mm or 40mm. Sample holders are also available with combination thin section/round options. Image courtesy of Dr. Axel Gerdes, Goethe-University Frankfurt S155 Cryogenic Development The M50A cryo cell achieved successful results with ice core sample studies (Müller et al., JAAS, 2011, 26, 2391) and as a result, a cryo sample holder will soon be available for the leading S155 sample cell.

100um GeoStar µgis TM Software GeoStar μgis software has been specifically written for RESOlution instruments. Its intuitive interface is easy to learn and it allows new users to get started very quickly. An extensive range of sophisticated features ensures that any researcher can easily program an ablation sequence. The software is great for both manual point selection and for automated runs thousands of points long. Special design features make sample navigation a breeze: rich sample imagery and automated mosaic collection will ensure you always choose the correct grain, phase, or growth band for ablation. The unique structured interface is simple for users to learn, along with many powerful features for the conscientious laboratory manager: Completely automated instrument control Integrated on-sample fluence calibration and laser energy management Visual-Stage-Correction offers sub-micron positioning Import images from any source, such as an SEM or petrographic microscope Integrate with any ICP-MS Import SEM images. Laser fluence management ensures the correct on-sample fluence throughout the working week. Laser output is continuously monitored for reliable gas handling and exceptional laser ablation.

GeoStar is designed for complete automation, while also offering manual point-by-point ablation. When creating an automated sequence the software supports many thousands of points, and offers: Drag and drop reordering Cut and paste reordering Undo and redo operations ll the colours should be same as your document, aside from the 75% opacity on the bottom box. 11 mj 15%T 30%T 50%T 100%T 9 mj 7 mj 5 mj 3 mj 1.3kV 1.2kV 1.1kV 1.0kV 0.9kV 0.8kV Visual and name-based selection 1 mj 1J.cm -2 6J.cm -2 11J.cm -2 16J.cm -2 Distribute feature automatically brackets samples with standards Ablation Cell RESOlution Model Laser Safety -SE Specifications S155 - LR Compliant to FDA/CDRH 21 CFR, Class I laser system, laser fully interlocked, fully enclosed beam path. Laser Wavelength 193 nm Laser Pulse Width 5-7 ns 20 ns Internal Energy Meter Yes (closed-loop feedback) *Maximum Pulse Energy 12 mj 200 mj Maximum Average Power 1.5 W 4 W Pulse-to-PulseEnergy Stability < 2 % RSD < 1 % RSD Maximum Repetition Rate 300 Hz 20 Hz Laser Cooling Air Air Maximum Fluence >20 J/cm 2 30 J/cm 2 Round / Square Spot Sizes Rectangular Slit Sizes Stage Movement Range 2 300 μm* (*with Beam Expander Option) Length: 2 300 μm* Width: 2 300 μm* (*with Beam Expander Option) 155 x 105 mm 2 380 μm Length: 2 380 µm Width: 2 380 µm Stage Reproducibility < 3 micron 2 sigma System Weight 725 kg (1600 lbs.) 1240 kg (2740 lbs.) System Width 119 cm (47 ) 179 cm (71 ) System Depth 89 cm (35 ) 89 cm (35 ) System Height 195 cm (77 ) 172 cm (68 ) *Measured at low repetition rate. Measured at maximum repetition rate.

Firsts in LA-ICPMS First dual-volume cell brought to market that delivers highly precise analytical abilities to all of our users. This cell ensures: Minimal fractionation Signals stable in time Sensitivity uniform over the entire 155x105 sample area Fast wash-out time, and optional smoothing when required First exhaust valve for diversion of unwanted ablation material from the ICP, reducing the service interval on the ICP: less cone cleaning! First off-axis camera on a LA instrument, for improved sample imaging and navigation. First rotating rectangular slit for dynamic highresolution tracking of banded samples. First ultra large spot sizes available for bulk analyses, maximized sensitivity, or delicate surface and thin film analyses. First software with powerful image import to assist with identification of complex structures in samples, such as inclusions and growth zones. GJ-1-10 pulses - 29um rectangle First software with freely available offline point definition for collaboration with remote users and improved efficiency of instrument use. First software with advanced μgis sample navigation for ease of use, fast user training times, and enhanced convenience. First system with secondary mass flow controller (MFC) for N 2 (or other diatomic gas by request) as standard, for improved sensitivity. First system with advanced squid device for perfect signal smoothing at low repetition rates without over extending washout time or introducing memory effects. First independent cross platform ICP-MS torchout detection system First system with fully integrated support for remote control and remote work-station options. GJ-1-10 pulses - 20um circle QUARTZ - 100 pulses - 29um circle

RESOchron for double dating Combining the well-established RESOlution and Alphachron TM technologies, RESOchron integrates a 193nm excimer laser ablation sampling system, ultra--high vacuum (UHV) sample cell and 3 He/ 4 He mass spectrometer (both pictured right). A RESOchron coupled to an ICPMS (not supplied by ASI) enables researchers to: 1. Rapidly determine both the (U-Th)/Pb and (U-Th- Sm)/He ages on a single mineral; 2. Avoid using hazardous chemicals for mineral dissolution; 3. Generate up to 50 mineral ages in the time it previously took to obtain a single age result. This new instrument platform permits more accurate and cost-effective thermochronology and geochronology age determination in addition to novel applications such as He distribution visualisation and thermal history reconstruction. The ASI RESOchron instrument (ICP-MS not pictured) UHV Cell for Noble Gas Geochemistry The noble gas cell is designed to provide an Ultra High Vacuum (UHV) environment for the analysis of nobles gases in geological samples via laser ablation. The cell is mounted on top of an XY stage and enables analysis of multiple samples mounted in two styles of sample holder. The noble gas cell is integrated with the RESOlution system via the GeoStar software. Connection of the sample cell to the mass spectrometer is made through a flexible bellows. 43 sample conical well Multi-sized flat bottom holder Key specifications: Fully compatible with existing RESOlution instruments. Stage reproducibility <+/- 3um. Hot plate and wrapped gas transfer lines are controlled with an integrated PID heater control unit for both manual and timed automated bake-out of samples prior to analysis. The standard unit is supplied with a 43 position conical sample holder and a multi-sized flat bottom sample holder. Multiple sample holders are available and custom styles upon request. Available fused silica or Z-cut quartz window.

Crater Gallery 111-113 Gladstone Street (PO Box 857) FYSHWICK ACT 2609 Australia Phone +61 2 6126 2100 email resolutionsales@asi-pl.com.au www.asi-pl.com.au