It is important to install this product in accordance with the fitting instructions below. Failure to do so may render your guarantee void.

Similar documents
It is important to install this product in accordance with the fitting instructions below. Failure to do so may render your guarantee void.

Version 2. Inline Relay (500W) Model No. LW821. Instruction Manual. Connect Series.

Dimmable Energy Saving CFR with Mood Remote. Model No s: JSJS LW560/561/562

Power Socket (1 Gang)

Version 2. On/Off/Stop Switch. Model No LW826. Instruction Manual. Connect Series.

Version 2.1. Socket Locker. Model No. LW103. Instruction Manual. Connect Series.

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Rako RAK4-R Instruction Manual

Installation and Hardware Guide

PIR Movement Sensor. Instruction Manual. Connect Series. Model No. JSJSLW107. Version 2

Installation Manual for D244X Series 24-volt Power Supplies

lightwaverf Lightwave Link Model No. JSJSLW500 Instruction Manual Connect Series

Nokeval. FD100 series. User Manual

B60 Domestic Voltage Optimisation Unit

Digital Thermostat for drum heaters Model HCL 5536

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

DEEP SEA ELECTRONICS PLC

Extension module for lighting control

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

B60 Domestic Voltage Optimisation Unit. Installation Manual

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Documentation on all Paxton products can be found on our web site -

Supplementary manual UVR16x2E-DE/NP Relay versions

Slimline LED Floodlight

EMS-PT30X & EMS-PT50X

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Orbital smart Tunable Downlight


Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104

Instruction Manual. Electrical Management System (EMS) EMS-PT30X & EMS-PT50X

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

Weathersafe Vision. Installation & Operating Instructions

Mounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003

Quick Installation Guide

Installation Instructions

ZenNet Installation Guide:

PRO-HC IRRIGATION CONTROLLER

Wiring Accessories for a Smarter Home

B60 Domestic Voltage Optimisation Unit. Installation Manual

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

Digital Room Thermostat

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Wireless Control Systems

PRO-1250D CT MID DIN rail three phase four wire energy meter.

FIBARO SINGLE SWITCH

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

SSR 303 One Channel 3 Amp Switch (Rx Only) - Z-Wave. User and Installation Instructions

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Quick Start Installation and User Manual

INSTALLATION INSTRUCTIONS

Type: P9680 Combined Overcurrent and Earth Fault Relay

LC SmartGlass SPD SmartGlass

Non-communicating room controllers

Mini Energy Dimmer MH-P210

Wireless 7 Day Programmable Room Thermostat

SOLARIMMERSION IV Advanced Installation Manual v1.9

MCU-9201MT22 venetian blind controller

OT EASY 60 II. LED control unit Operating instructions

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

INSTALL & SET-UP GUIDE

Technical Data. Surface Boxes And Blank Plates. Brief product description: Features:

NEUTRAL GROUNDING RESISTOR WITH, N.G.R. MONITORING & PROTECTION RELAY

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Q. Can I use LED bulbs? A. Yes as long as the bulbs are dimmable variants and compatible.

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

Fire Shutter Electrically Operated. Insert address here OPERATING AND MAINTENANCE MANUAL SAFETY, SERVICE & REPAIR. flexability is our strength

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

VRp Three-Phase Precision AC Voltage Regulator

Z-Wave AC Motor Shutter Controller

120 lm HIGH LUMINOUS EFFICIENCY

Assembly and Operating Instructions Door Control

A11 User s Manual (ZigBee Wireless Smart Plug) Ver. 1.04

B60 PVM Domestic Voltage Optimisation Unit. Installation Manual

Technical Data. Wi-Fi Socket Range Extender. Features: 922WR

Application Techniques CENTERLINE 2100 Motor Control Centers

ECM-1220 User s Manual

StringPin Pinsetter with Electrical Requirements

Manual Simatek Control Unit GFC 32

Remote Time Delay Switch 3-wire version

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

Installation Instructions

Security and Convenience Components 519H Three-Channel Receiver

920 Remote Control (RC) Switches

7 Day Programmable Room Thermostat

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

SoundwebTM. Installation Guide

BLDA-1 & 2 Water Leak Detection Manual. CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel:

Sigma XT Ancillary Board (K588)

Product Data Sheet. Hochiki 8 Way I/O Card. Features

Transcription:

ightwaverf connect Inline Relay Operation Manual Model o: JSJS W821 It is important to install this product in accordance with the fitting instructions below. Failure to do so may render your guarantee void. IMPORTAT: PEASE RETAI THESE ISTRUCTIOS FOR FUTURE REFERECE AD FOR GUIDACE O THE ASSOCIATIO OF REMOTE HADSETS. FOR HEP AD SETUP GUIDACE PEASE VISIT www.lightwaverf.com OVERVIEW: ED Pairing Button Fuse Wiring Terminals

Wiring Terminals Separate Relay Circuit Volts Free Mains Power 230v - The Inline Relay is designed to work with devices such as blinds, curtain openers and garage doors. It can also switch lighting circuits up to 500w. - The relay is mains powered and rated at 500w. - The relay can be used to provide mains powered switching up to 500w OR separate volts free switching for low voltage circuits. IMPORTAT: The Inline relay is not designed to be left exposed once it is installed, as live mains wiring is connected to the terminals. Ensure that the device is mounted securely in a suitable housing.

FITTIG AD WIRIG ISTRUCTIOS: Important Things to Consider Before you Begin 1). Before commencing work, AWAYS isolate the mains power supply and remove the fuse in the fuse box or switch off the circuit breaker in the consumer unit. 2). If unit is to be used as a replacement for an existing product, remove existing unit from its location and disconnect the wiring. 3). Connect the wires as shown in appropriate wiring diagrams. Use green/yellow sleeving on any earth conductors not insulated. Ensure terminals are properly tightened and no bare wire is visible. When mounting products into mounting boxes make sure conductors are not trapped. 4). Products must be installed in accordance with the latest building and IEE wiring regulations. If in any doubt, please contact a qualified electrician.

Installing power to the Inline relay 1) Switch off the mains power 2) Connect the ive and eutral Terminals to the mains circuit live and neutral wire as shown in the diagram. ive Wire eutral Wire OTE: Even if switching a low voltage or non-mains circuit, the relay must always have mains power to the live and neutral terminals (as shown above) for it to be able to function. Connecting the Inline Relay to a low voltage or non-mains powered circuit 1) Connect the incoming live wire from the low voltage circuit to the common (com) terminal. 2) Connect the outgoing wire load to either of the load terminals ( ).

oad ive Wire The relay now has 2 positions - on and off. The diagrams below show the on and off positions if a live were to be connected to the common and load to the leftmost load terminal. On Position - circuit connected Off Position - disconnected IMPORTAT: When operated via RF, it is always the lefthand load terminal that will be connected when the on button is pressed. Therefore, if the circuit is wired as shown, pressing on using an rf remote will turn on the circuit, and off will disconnect it.

Switching between two Circuits If a second load wire connected to another circuit is attached to the second load terminal (see diagram), the relay can be used to switch between two circuits. oad 1 ive Wire oad 2 Position 1 - circuit 1 connected Position 2 - circuit 2 connected

In addition to the on and off positions there is also a stop position which breaks contact with both of the right and lefthand circuits. Stop Position IMPORTAT: In this case, a standard handheld or other ightwaverf remote control will only be able to utilise the on and off commands to switch between circuits OT the stop command as each remote has only two buttons on each channel. To operate the stop command you will need a ightwaverf Stopswitch which includes on/off (open/close) and stop commands. OR a smartphone using the ightwaverf App and Wifiink. If you are using the app, when you set up the device you must set it to be an open/close device. This will give you the stop command as well as on/off (open/close) when you come to operate the device from the smartphone.

Curtains, Blinds and Doors Because of the Stop command feature, the relay can be used to operate a device that requires an on/off (or open/close) function AD a stop (or pause) function, such as blinds, curtains and doors. In this case, as before, the incoming live wire will be connected to the com terminal, and there will be two separate outgoing load wires each connected to the separate load terminals (see diagram). oad ive Wire oad OTE: Because of the stop command, a ightwaverf Stopswitch or Wifi-ink driven smartphone will be required to operate this setup. Connecting the Inline Relay to a Mains Powered Circuit If the relay is being used to control a mains powered circuit (max 500w load), then power must be taken from the relay s main live terminal via a jumper connection to the common terminal (see diagram). The neutral terminal must now also accommodate an incoming and outgoing connection to the mains circuit. oad ive eutral

SETUP: IMPORTAT: Make sure that the relay is accessible once installed in order to operate the pairing button Pairing with a ightwaverf transmitter 1) Press and hold the pairing button on the Inline Relay until the green ED starts to flash. 2) Press the on or up button on the transmitter. The ED will flash quickly for 2 seconds to indicate a successful pairing. OTE: The Inline Relay can be paired with up to 6 separate transmitters at any one time. Unpairing with a IghtwaveRF transmitter 1) Press and hold the pairing button on the Inline Relay until the green ED starts to flash. 2) Press the off or down button on the transmitter (the ED will flash quickly for 2 seconds to indicate a successful unpairing of that device. Complete Memory Reset Press and hold the pairing button on the Inline Relay until the green ED starts to flash. Release the button once it begins to flash. 2) Press the pairing button a second time. The ED will flash quickly for 2 seconds to indicate that the memory has been cleared.

OPERATIO: If using an on/off transmitter such as the handheld remote... 1) Press the on button on the transmitter to turn the circuit on or switch between circuits. 2) Press the off button on the transmitter to turn the circuit off or to switch between circuits. If using a ightwaverf 'Stopswitch' or smartphone... 1) 1) Press the on / open button on the transmitter to turn the circuit on or switch between circuits. 2) Press the off / close button on the transmitter to turn the circuit off or switch between circuits. 3) Press the stop button to disconnect both circuits and cut power to connected devices. Outdoor Use An IP 56 rated waterproof housing is available for the Inline relay, enabling safe indoor and outdoor use. OTE: If the RF range between the transmitter and receiver is too great to achieve reliable operation, the ightwaverf SIGA BOOSTER may be used in conjunction with this product to increase the signal strength over greater distances.

SPECIFICATIO: Radio frequency: 433.92 MHz Input: 230V~ / 50Hz Output: max. 500 watts for resistive load Operating distance: 30 meter closed field. Standby power consumption: 0.5 w. Birmingham Science Park Aston Faraday Wharf Holt Street Birmingham B7 4BB Tel: 01902 500 562 Email: support@jsjsdesigns.com