Tundra Extreme Scale (ES) Open Compute Solutions Guide

Similar documents
Open Compute Solutions Guide

Linkedin Open19 Deep Dive

Linkedin Open19 Deep Dive

Cisco UCS C200 M2 High-Density Rack-Mount Server


AMD Disaggregates the Server, Defines New Hyperscale Building Block

Arista 7010 Series: Q&A

Cisco HyperFlex HX220c M4 Node

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n

Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches

UCS M-Series + Citrix XenApp Optimizing high density XenApp deployment at Scale

Mellanox Virtual Modular Switch

Intel Rack Scale Architecture. using Intel Ethernet Multi-host Controller FM10000 Family

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Veritas NetBackup on Cisco UCS S3260 Storage Server

POWERMAX FAMILY. Appliance-based packaging. PowerMax 2000 and Specifications. Specification Sheet. PowerMax Arrays

3331 Quantifying the value proposition of blade systems

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Telecom Open Rack Concept

Cisco UCS Mini Software-Defined Storage with StorMagic SvSAN for Remote Offices

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Cisco UCS B230 M2 Blade Server

Warehouse-Scale Computers to Exploit Request-Level and Data-Level Parallelism

This work is licensed under a Creative Commons Attribution 4.0 International License.

Thermal management. Thermal management

CPS VS UPS FOR POWERING DATA CENTERS

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Achieve Optimal Network Throughput on the Cisco UCS S3260 Storage Server

Arista 7160 series: Q&A

Fidelity. Open Bridge Rack v1.0

Cray XC Scalability and the Aries Network Tony Ford

Intel Select Solutions for Professional Visualization with Advantech Servers & Appliances

IBM System Storage DS8800 Overview

DELL EMC VMAX3 FAMILY

Networking Terminology Cheat Sheet

TECHNOLOGIES CO., LTD.

Sugon TC6600 blade server

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

DCEngine Rack, Compute and Storage System Specification for CG-OpenRack-19 Version 1.0. Author: Matt St Peter, Radisys Corporation

Topics. CIT 470: Advanced Network and System Administration. Google DC in The Dalles. Google DC in The Dalles. Data Centers

Deep Dive QFX5100 & Virtual Chassis Fabric Washid Lootfun Sr. System Engineer

Arista 7320X: Q&A. Product Overview. 7320X: Q&A Document What are the 7320X series?

About 2CRSI. OCtoPus Solution. Technical Specifications. OCtoPus servers. OCtoPus. OCP Solution by 2CRSI.

EMC SYMMETRIX VMAX 10K

Network Design Considerations for Grid Computing

About 2CRSI. OCtoPus Solution. Technical Specifications. OCtoPus. OCP Solution by 2CRSI.

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

Charles Nolan. Do more with less with your data centre A customer s perspective. Director IT Infrastructure, UNSW. Brought to you by:

Data Center Server Agnostic Power Management

Next Generation Computing Architectures for Cloud Scale Applications

How Smarter Systems Deliver Smarter Economics and Optimized Business Continuity

<Insert Picture Here> Exadata Hardware Configurations and Environmental Information

Close-coupled cooling

Mika Hatanpää Head of AirFrame data center solutions R&D Nokia

CG-OpenRack-19 Sled and Rack Specification Version 1.0

Introduction to EDSFF

Cisco UCS B440 M1High-Performance Blade Server

SUSE OpenStack Cloud Production Deployment Architecture. Guide. Solution Guide Cloud Computing.

Virtualization and consolidation

Arista 7300X and 7250X Series: Q&A

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Maailman paras palvelinjärjestelmä. Tommi Salli Distinguished Engineer

Cisco UCS Virtual Interface Card 1225

Radisys* and Intel Deliver Agile and Flexible Rack-Scale NFV Infrastructure for. Communications Service Providers

Scaling to Petaflop. Ola Torudbakken Distinguished Engineer. Sun Microsystems, Inc

CAS 2K13 Sept Jean-Pierre Panziera Chief Technology Director

Rack Systems. OpenBlade High-Density, Full-Rack Solution Optimized for CAPEX & OPEX

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Cisco Nexus 9500 Platform Switches for Cisco Application Centric Infrastructure

Concepts Introduced in Chapter 6. Warehouse-Scale Computers. Programming Models for WSCs. Important Design Factors for WSCs

Cold Storage Hardware v0.7 ST-draco-abraxas-0.7

EMC SYMMETRIX VMAX 40K SYSTEM

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

IBM Virtual Fabric Architecture

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Pass-Through Technology

ETHERNET SWITCHING PORTFOLIO

BS2000/OSD Business Server S210

SSG-6028R-E1CR16T SSG-6028R-E1CR24N/L SSG-2028R-E1CR48N/L SSG-6048R-E1CR60N/L

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

IP Video Network Gateway Solutions

Yuval Bachar. Principal Engineer, Global Infrastructure & Strategy at President, Open19 Foundation

Cutting Cabling Costs By Mike Martin

Power+ Family Products. P+ Family Products: Seth Davis- Global Marketing Manager

Cisco UCS C24 M3 Server

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

HUAWEI Tecal X6000 High-Density Server

John Fragalla TACC 'RANGER' INFINIBAND ARCHITECTURE WITH SUN TECHNOLOGY. Presenter s Name Title and Division Sun Microsystems

Switch to Perfection

Power & Cooling Considerations for Virtualized Environments

Results of Study Comparing Liquid Cooling Methods

Transcription:

Tundra Extreme Scale (ES) Open Compute Solutions Guide Awarded the Department of Energy s National Nuclear Security Administration (NNSA) Advanced Simulation and Computing (ASC) CTS-1 contract www.penguincomputing.com 1-888-PENGUIN (736-4846) twitter: @Penguin HPC

Tundra Rack and Power Infrastructure Open Compute Open Bridge Rack contribution from Fidelity Convertible from 19in EIA to 21in OCP and back as needed Optimized serviceability with cold aisle maintenance Up to 26.4kW with a Single Zone and N+1 Redundancy/ Up to 30 kw with a Dual Zone and N+3 Redundancy Available in 40 OU/42 RU and 44 OU/48 RU heights Cost reduction in delivering power to the racks Power shelves fed with 120/208V, 230/400V or 277/480V circuits High voltages mean lower current, smaller wires, fewer breakers Distributing power to all equipment in the rack at 12V Voltage conversion steps eliminated, Power infrastructure can be re-used Dramatic ROI improvements over multiple generations of hardware power redundancy features Phase currents balanced by design of load sharing modules Optional A/B redundant feeds, and/or N+1 redundant power supplies Servers, network and storage equipment can be powered from 12V TUNDRA TUNDRA SERVER RACK SHELF AND POWER COMPUTE/STORAGE INFRASTRUCTURE SERVERS

Tundra Server Shelf width boards, up to 173mm wide. Tundra OpenHPC Compute Server Shelf supports mixed Tundra OpenHPC Shelf is 1 OU height (Open U) Compatible with third party motherboards Compute and Storage Servers timized clusters and virtualized server farms. A variety of compute, application optimized and storage server options are available, including a dual-processor, high performance x86 server, an Intel Xeon Phi server, a power optimized high core count ARM 64-bit server and a 4 drive storage server optimized for Swift or Ceph storage architectures. Relion 1930g Relion 1930e IceBreaker 1905g Valkre 1030c Relion 1930g is a high density, Relion 1930e is a high IceBreaker 1905g is a high den- Tundra Valkre product family is high performance x86 platform performance compute node sity storage solution designed based on the emerging 64-bit to support up to 4x 3.5 or 2.5 ARM architecture. Tundra Valkre SATA HDDs. 1030c features the Cavium Thun- for technical comp uting and VM hosting workloads. 100Gbps fabric technologies. derx processor and built-in high performance network interfaces. TUNDRA SERVER SHELF AND COMPUTE/STORAGE SERVERS

Network and Interconnect Network shelves support standard 19in EIA 1U switches 1G Ethernet, 10G Ethernet, 40G Ethernet Arctica switches Allow for in-rack cabling of nodes to Leaf and TOR using short copper cables Arctica Ethernet switches from Penguin Computing Open source Cumulus Linux software option Can be managed like any other node using standard provisioning tools High speed uplinks to avoid bottlenecks and oversubscription In rack leaf switches are preferred Active Optical Cable (AOC) preferred for leaf to spine links Cooling Options Tundra designed to use air/liquid cooling CoolIT/Asetek direct-to-chip central pump/distributed cooling Optional rear chilled water radiator can support local cooling Access to hot aisle side of rack not required for service mounting of radiator Can be coupled with: Free Cooling Chiller Systems Chilled Water Systems Ground Source Water Systems River or other natural water sources NETWORKING/INTERCONNECT AND COOLING FEATURES

Total Cost of Ownership Leverage the TCO savings Facebook reported Cost reduction in delivering power to the racks High voltages mean lower current, smaller wires, fewer breakers Cost reduction in delivering power to the racks Distributing power to all equipment in the rack 12V Voltage conversion steps eliminated, Power infrastructure can be re-used Dramatic ROI improvements over multiple generations of hardware Fewer power supplies mean fewer failures Reduced infrastructure cost during technology generation transition Facebook Statement Facebook s first generation Open Compute 1.0 hardware had world-classtco and ROI. As we looked to improve on that with Open Rack, we foundthat it wasn t giving us the reductions in TCO and improvements in ROIthat we were looking for... Until we factored in the savings overtwo generations of hardware in the same Open Rack. Then the TCO androi became obvious and undeniable. Frank Frankovsky, Facebook TOTAL COST OF OWNERSHIP

For any questions regarding these systems and their email: sales@penguincomputing.com phone: 1-888-PENGUIN (477-2206) http://www.penguincomputing.com/products/open-compute-project/ http://www.penguincomputing.com/products/tundra-es/