EC centrifugal fan - RadiPac

Similar documents
EC centrifugal module - RadiPac

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac

EC axial fan - HyBlade

Operating instructions

Operating instructions

Operating instructions

Operating instructions

Operating instructions

air comfort Centriflow 3D

Operating instructions

Operating instructions for built-in fans with three-phase powered motors, sizes 112 and 150

Operating instructions

EC/AC centrifugal fans - RadiCal

Operating instructions

Operating instructions

Operating instructions

Operating instructions

Operating instructions

Operating instructions

Operating instructions

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Operating instructions

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Operating instructions

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Operating instructions

Operating instructions

Operating instructions

Operating instructions

Operating instructions

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Operating instructions

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Operating instructions

Operating instructions

Operating instructions

Operating instructions

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Operating instructions

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

Operating instructions

Operating instructions

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Operating instructions

DI572 Digital Input Module

ebm-papst EC communication

Operating instructions

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Operating instructions

Operating instructions

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

DC562, digital input/output module,

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

Si 2035 Programmable Stepper Drive

DC561, digital input/output module,

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

Faults on the system Proximity switch connection technology:

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

DI561 Digital Input Module

PKS-FD432S-13 - Servo System

InBin-P Pressure switches from 5 Pa Pa

KNC-SRV-FD332S Servo Driver

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

DX561 Digital Input/Output Module

AI561 Analog Input Module

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

TM221M16TG controller M IO transistor PNP spring

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Energy 3000 Primary Switched Power Supply 3000W VE3PUID ,5/L programmable V/I

TM221CE40R controller M IO relay Ethernet

ATV32H018M2 variable speed drive ATV32-0,18 kw V - 1 phase - with heat sink

CFM-9225V XX - CXX

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

TF501, TF521 Terminal Bases

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Interface Relay CRINT-1x

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

TPE, TPED Series 2000

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

Transcription:

R3G31-AX54-21 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA 59344 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRB 59142 Nominal data Type Motor R3G31-AX54-21 M3G112-EA Phase 1~ Nominal voltage VAC Nominal voltage range VAC 2.. 277 Frequency Hz /6 Method of obtaining data ml Speed min -1 28 Power consumption W 127 Current draw A 5.6 Min. ambient temperature C -25 Max. ambient temperature C 6 ml = Max. load me = Max. efficiency fa = Free air cs = Customer specification ce = Customer equipment Subject to change Data according to ErP Directive Actual Req. 215 1 Overall efficiency η es % 59.4 52.6 2 Measurement category A 3 Efficiency category Static 4 Efficiency grade N 68.8 62 5 Variable speed drive Yes Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller combination in a standardized measurement setup. 9 Power consumption P ed kw 1.27 9 Air flow q v m³/h 279 9 Pressure increase p fs Pa 93 1 Speed n min -1 284 11 Specific ratio * 1.1 * Specific ratio = 1 + p fs / 1 Pa LU-1262 Item no. 235-5-998 ENU Change 84593 Approved 215-1-5 Page 1 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 () 7938 81- Fax +49 () 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com

R3G31-AX54-21 Technical description Weight Fan size Rotor surface Electronics housing material Impeller material Number of blades 7 Direction of rotation Degree of protection Insulation class Moisture (F) / Environmental (H) protection class Max. permitted ambient temp. for motor (transport/storage) Min. permitted ambient temp. for motor (transport/storage) Installation position Condensation drainage holes Mode Motor storage Technical features Touch current according to IEC 699 (measuring circuit Fig. 4, TN system) Electrical hookup Motor protection With cable Protection class Conformity with standards 11 kg 31 mm Painted black Die-cast aluminum Sheet aluminum Clockwise, viewed toward rotor IP54 "B" F4-1 +8 C -4 C Shaft horizontal or rotor on bottom; rotor on top on request On rotor side S1 Ball bearing - RS-485 MODBUS-RTU - Control input -1 VDC / PWM - Tach output - Thermal overload protection for electronics/motor - Alarm relay - PFC, active - Integrated PID controller - Input for sensor -1 V or 4-2 ma - Output for slave -1 V - Motor current limitation - Soft start - Line undervoltage / phase failure detection - Output 1 VDC, max. 1 ma - Output 2 VDC, max. ma <= 3.5 ma Via terminal box Thermal overload protector (TOP) internally connected Variable I (with customer connection of protective earth) Approval EAC; UL 14-7 + 6 CE Item no. 235-5-998 ENU Change 84593 Approved 215-1-5 Page 2 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 () 7938 81- Fax +49 () 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com

R3G31-AX54-21 Product drawing 1 Cable diameter min. 4 mm, max. 1 mm; tightening torque 4 ±.6 Nm 2 Accessory part: inlet ring 31575-2-413 not included in scope of delivery 3 Clearance for screw 12-16 mm 4 Tightening torque 3.5 ±.5 Nm Item no. 235-5-998 ENU Change 84593 Approved 215-1-5 Page 3 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 () 7938 81- Fax +49 () 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com

R3G31-AX54-21 Connection diagram No. Conn. Designation Function/assignment KL1 1 L1 Supply connection, power supply 1-phase 2-277 VAC; /6 Hz KL1 2 N Supply connection, power supply 1-phase 2-277 VAC; /6 Hz PE PE Ground connection, PE connection KL2 1 NO Status relay, floating status contact; Option 1: Make for failure; Option 2: Make for run monitoring error message KL2 2 COM Status relay, floating status contact; changeover contact; common connection; contact rating 2 VAC/ max. 2 A (AC1)/min. 1 ma KL2 3 NC Status relay, floating status contact; Option 1: Break for failure; Option 2: Break for run monitoring error message KL3 1 RSA Bus connection RS485; RSA; MODBUS RTU KL3 2 RSB Bus connection RS485; RSB; MODBUS RTU KL3 3 GND Reference ground for control interface KL3 4 Ain1 U Analog input 1 (set value); -1 V; Ri = 1 kohms; adjustable curve; only for use as alternative to input Ain1 I KL3 5 +1 V Fixed voltage output 1 VDC; +1 V ±3%; max. 1 ma; short-circuit-proof power supply for ext. devices (e.g. potentiometer) KL3 6 Ain1 I Analog input 1 (set value); 4-2 ma; Ri = 1 ohms; adjustable curve; only for use as alternative to input Ain1 U KL3 7 Din1 Digital input 1: Enable electronics; Enable: Pin open or applied voltage 5... VDC; Disable: Bridge to GND or applied voltage <.8 VDC; Reset function: Triggering of software reset after level change to <.8 V KL3 8 Din2 Digital input 2: Parameter set 1/2 switching; Depending on EEPROM setting, the valid/used parameter set can be selected via BUS or digital input DIN2. Parameter set 1: Pin open or applied voltage 5... VDC; Parameter set 2: Bridge to GND or applied voltage <.8 VDC KL3 9 Din3 Digital input 3: Direction of action of integrated controller; According to EEPROM setting, the direction of action of the integrated controller can be selected as normal/inverse via bus or digital input; Normal: Pin open or applied voltage 5... VDC; Inverse: Bridge to GND or applied voltage <.8 VDC KL3 1 GND Reference ground for control interface KL3 11 Ain2 U Analog input 2; Measured value -1 V; Ri = 1 kohms; adjustable curve; only for use as alternative to input Ain2 I KL3 12 +2 V Fixed voltage output 2 VDC; +2 V +25/-1%; max. ma; short-circuit-proof power supply for ext. devices (e.g. sensors) KL3 13 Ain2 I Analog input 2; measured value: 4-2 ma; Ri = 1 ohms; adjustable curve; only for use as alternative to input Ain2 U Item no. 235-5-998 ENU Change 84593 Approved 215-1-5 Page 4 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 () 7938 81- Fax +49 () 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com

R3G31-AX54-21 No. Conn. Designation Function/assignment KL3 14 Aout Analog output -1 V; max. 5 ma; output of current motor modulation level/of current motor speed Adjustable curve. Item no. 235-5-998 ENU Change 84593 Approved 215-1-5 Page 5 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 () 7938 81- Fax +49 () 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com

R3G31-AX54-21 Curves: Air performance Hz Druck p f s[pa]für Rho=1,2kg/m^3 1.3 1. qv[cfm] 1. 2. 2. 3. 5,2 1.2 5 1.2 4,8 1.1 1.1 1. 1. 9 9 8 8 7 7 6 6 5 12 8 4 7 3 4,6 4,4 4,2 4 3,8 3,6 3,4 3,2 3 2,8 2,6 2,4 2,2 2 pfs_e[in H2O] Measurement: LU-1262 Measurement: LU-131413 Measurement: LU-131415 Measurement: LU-131416 Air performance measured according to ISO 581 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit. 4 4 3 3 16 11 6 2 1,8 1,6 1,4 1,2 2 2 15 1 1,8 1 1 14,6,4 1. 1. 2. 13 2. 3. qv[m^3/h] 9 3. 5 4. 4. 1 5.,2 Measured values 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 U V f Hz n min -1 293 2895 28 28 243 243 243 243 P ed W 946 1147 127 1237 529 663 743 751 299 36 398 4 139 159 177 184 I A 4.14 5.1 5.6 5.41 2.34 2.91 3.26 3.29 1.36 1.61 1.77 1..72.79.86.89 LpA in db(a) 81 76 72 75 77 7 66 65 66 64 59 58 59 LwA in db(a) 88 83 79 83 84 77 72 67 65 66 LwA out db(a) 94 9 87 89 89 85 84 85 83 79 79 76 72 qv m 3 /h 498 434 341 4165 3585 2925 198 3345 286 2335 1585 25 213 15 1185 p fs Pa 425 76 1 39 556 1 193 356 499 16 196 28 U = Power supply f = Frequency n = Speed P ed = Power consumption I = Current draw LpA in = Sound pressure level intake side LwA in = Sound power level intake side LwA out = Sound power level outlet side qv = Air flow p fs = Pressure increase Item no. 235-5-998 ENU Change 84593 Approved 215-1-5 Page 6 / 6 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-746 Mulfingen Phone +49 () 7938 81- Fax +49 () 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com