User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

Similar documents
FW-SP-ACA FW-SP-250 FW-SP-R

FLEXmax 100 with ICS Plus

Radian Series Inverter/Charger GS4048A GS8048A. Installation Manual

C5C Cross-Connect System

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

2U ATX12V 2.01 Power Supply

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

Project Olympus Chassis Mechanical Specification

FLEXware Integrated Combiner Solution Plus. Owner s Manual

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

iconverter 2-Module Power Chassis

Replacing the Power Supply

CA-A480-A Elevator Controller. Reference & Installation Manual

FX AND VFX SERIES INVERTER/CHARGER Programing Manual

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

Reliable ATX 12V 2.01 Power Supply

MONITORING INTELLIRACK USER MANUAL

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

ENERGIA RENOVABLE BACK-UP POWER APLICACIONES MOVILES

Kinetix 6000 Axis Module and Shunt Module

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

Resolver to Digital Expansion Board

ATX12V 2.2 Power Supply for HP & Compaq Systems

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

PIX 520. PIX 520 Product Overview CHAPTER

Basketball Shot Clock Set LX2180 Manual

FLEXmax 100 Charge Controller. Owner s Manual

NPort S8000 Series Quick Installation Guide

FDS / FDS-R / FDS-PS

INSTRUCTION MANUAL RA 60 SERIES RACK ADAPTER RA 60, RA 62, AND RA 63. 1) This manual is valid for the following Model and associated serial numbers:

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

PIX 535. PIX 535 Product Overview CHAPTER

Solar Combiner Enclosure

Chameleon Labs Model CPS-501 Powered Chassis

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

MATE3 System Display and Controller Owner s Manual

Power Supply (48Vdc, 2.5A)

Rackmount Keyboard Installation Instructions. Revision A A-0000

Site Preparation CHAPTER

Series Amp Pad Mount Quick Connect Input and Output Power Panels

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Multi-Mount for Mac Pro " to 5.25" Drive Bay Converter Bracket. Assembly & Installation Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Installing the Server into a Rack

Web Site: Forums: forums.parallax.com Sales: Technical:

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

User s Manual. Revision 1.0. Copyright 2016 Maretron, LLP All Rights Reserved

3.5 SATA Drive Enclosure

EATON Transformer Module

Breaker Panel Technical Practice NPDRP1114

USB Port Hub HO

C-POWER AC AUTOMATIC CONTROL

4-Port USB 3.0 Rugged Industrial Din Rail Mount Hub

Stalking the Elusive and Somewhat Strange PV System

G12/G12x USER S MANUAL

Part Name/Description Part Number Quantity

Addendum to the Actalyst Interactive Digital Signage Installation and User s Guide

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

Surge Protective Devices. STV25K Series. Instruction Manual

InfoSafe Mobile Drive Enclosure

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

hp uninterruptible power system r12000 xr models installation instructions

Innovative Circuit Technology Ltd.

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

PACSystems* RX3i IC695ACC650

PowerLogic High Density Metering System 1-Meter Enclosure

User s Guide. POWERVAR Single Phase Power Conditioners

and Network Interface Modules Installation Instructions

HT2000 Transverter Installation & Operation Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Steltronic Universal LCD Mounting Bracket Assembly

INSTALLATION INSTRUCTIONS

Model DMX8DIM Installation and Operations Manual

Westell. Breaker Panel Technical Practice NPDRP1114

NT1B-300 Rack Installation Instructions

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

Installation Job Aid for Ethernet Routing Switch 5900 Series

ClearCube Enclosure Installation Instructions

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch. ISW-500T/ISW-800T User s Manual

INJ-24A Series Quick Installation Guide

Modbus Header Temperature Sensor Kits: Standard Voltage Low Voltage

V.I.A. - Monitor Shroud

Vision OPLC V TR6/V350-J-TR6

to 48V DC Power Supply

USER MANUAL Revised August 2, 2011

SAVE THESE INSTRUCTIONS

Progressive Industries, Inc. EMS Electrical Management System

S82S (3/7.5-W Models)

Broadband Automatic Disconnect Switch. User Manual

Transcription:

User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com 900-0002-01-00

OutBack Power Systems FLEXware is a system of modular aluminum mounting hardware and installation components designed for convenient system installation and integration. About OutBack Power Systems OutBack Power Systems is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, a maximum power point charge controller, system communication components, as well as breaker panels, breakers, accessories, and assembled systems. Notice of Copyright FLEXware 500 Manual Copyright 2006 All rights reserved. Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER SYSTEMS: (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK. Revision September 2007 Contact Information OutBack Power Systems 19009 62nd Ave. NE Arlington, WA 98223 Phone (360) 435-6030 Fax (360) 435-6019 www.outbackpower.com Product Registration Please take a moment to register and provide us with some important information. Send to: OutBack Power Systems, 19009 62nd Avenue NE, Arlington, WA 98223 USA. Name: Address: City, State, Zip Code: Country: Telephone Number: E-mail: Sold by: Installer: Purchase Date: Model Number: Serial Number: Check all that apply: m Off-Grid Installation m Grid-Tie Installation m Residential Installation m Commercial Installation

Requirements and Warnings The OutBack FLEXware 500 enclosures (FW500-AC and FW500-DC) are listed by ETL as indoor enclosures to UL standard UL 508A Industrial Control Panels. This enclosure is intended for battery circuits configured for 12 to 48 volts nominal. Grounding Instructions Each enclosure should be connected to a grounded, permanent wiring system. For most installations, the negative battery conductor should be bonded to the grounding system at one (and only one) point in the DC system. All installations must comply with all national and local codes and ordinances. System grounding as required by the National Electric Code, ANSI /NFPA 70-1996, is the responsibility of the system installer. The equipment ground on FLEXware 500 is marked with this symbol: FLEXware is designed for indoor mounting only with appropriate fasteners and a secure mounting surface that can handle the full weight of an assembled system.

Welcome to OutBack Power Systems FLEXware FLEXware is a convenient all-aluminum power system offering simpler, code-compliant installation of OutBack power electronics components. Three versions of FLEXware are available: FLEXware 250 for single FX Series Inverter/Charger installations along with the desired AC and DC disconnects FLEXware 500, which supports up to two FXs and two MX Charge Controllers, accommodating both split-phase and/or higher power output as needed FLEXware 1000 accommodates up to four FXs and four MX Charge Controllers Please Note: Both the FLEXware 500 and the FLEXware 1000 power systems provide locations for FW-X240 Auto-Transformers, multiple DC shunts and other essential components required in higher kw systems. 1

Getting to Know FLEXware 500 MX60s AC Breakers ACA FX (with DCC) DCA HUB IOB Kit FW500-AC FW Mounting Plate DC Breakers MX60 DC FW500-DC Disconnect Breaker Figure 1: Complete FLEXware 500 System installed (vertical installation is acceptable when mounting space is limited) Note: Although FLEXware 500 supports two MX Charge Controllers, both locations top and side are shown in Figure 1. 2

Knockouts and Dimensions 11.40 Front View 12.06 18.27 Side View Figure 2 Figure 15: Wiring Diagram 3 16

Installing an OutBack HUB An OutBack HUB allows the FX Series Inverter/Chargers, MX60 Charge Controllers, and MATE to communicate with each other. It attaches to the outside of the FW500-AC (hardware included with the HUB). HUB connection A complete FLEXware 500 System consists of the following in addition to the FW500-AC and FW500-DC: FLEXware Mounting Plate (FW-MP) two FX Series Inverter/Chargers AC Conduit Adapter (ACA) and a DC Conduit Adapter (DCA), which connect each FX to the FW500-AC and FW500-DC MX Charge Controller(s) (normally part of this system) and mounting brackets AC and DC breakers including a specific AC Input/Output/Bypass Breaker (IOB) Kit per installation bus bars and DC current shunts as required per specific installation DC and AC ground fault protection Some systems will work optimally with an FW-X240 Auto-Transformer installed. Note: Be sure you have all the parts required for your intended system installation. As every installation is different, consult with your dealer or installer for further information. FLEXware 500 Parts List FLEXware 500 consists of the FW500-AC and FW500-DC. Each is an aluminum chassis for mounting AC and DC breakers, respectively, along with the components listed below: Figure 14: OutBack HUB FW500-AC components: aluminum enclosure DIN rail bracket Breaker and Bypass Mounting Bracket TBB-GROUND flex nylon conduit and fittings (conduit runs between the FW500-AC and FW500-DC as needed) FW500-DC components: aluminum enclosure 500 amp shunt with TBB attached TBB-GROUND FW breaker bus DC Breaker Mounting Bracket FW500-DC Hardware Kit DC positive bus bar jumper wire from DC negative to ground 15 4

Installation Tips Never use less than the minimum recommended number and type of fasteners when installing the FLEXware Mounting Plates. Each FX weighs in excess of 50 lbs and is often more easily installed by two people rather than one. Be sure the DC enclosure is secured to the FLEXware Mounting Plate before attaching the MX Charge Controller to it. Installation of each enclosure and breakers is normally easier by removing the breaker brackets first. Do not remove any breaker knockouts from these brackets without referring to the chosen AC IOB kits and DC breaker selections first. It is also easier if all conduit knockouts are removed before mounting the enclosures. MX Knockouts Mounting and Installation FLEXware 500 is designed for mounting on the FLEXware Mounting Plate (FW-MP). Although the components can be secured to other surfaces, the FW-MP is an engineered platform designed for the FLEXware 500 installation. This manual illustrates such an installation. OutBack does not endorse other installation methods and therefore cannot recommend fasteners or other means of attachment due to the variety of installations possible in the field. Please see the FLEXware Mounting Plate Instructions for further information. Charge Controller knockouts In addition to installing the AC and DC chassis, a typical installation includes two FX Series Inverter/Chargers, an MX60 Charge Controller, a HUB Communications Manager, and AC and DC conduit adapters. The installation of these components is also displayed in these instructions. T Slot indicates this is the top edge of the FW-MP Figure 13: MX Charge Controller 1 knockouts The MX Charge Controller attaches to the chassis using three #10 X 3/8 sheet metal screws included in the hardware kit. Two are inserted from inside the MX and the third through the hanger on the top of the MX. Figure 3: FLEXware Mounting Plate 5 14

With the Mounting Plate and the hanging screws (for the FX Inverter/Chargers) inserted, MX60 Installation A FLEXware 500 System will normally have up to two MX Charge Controllers installed on the FW500-DC. The chassis accommodates both side and top installation. Newer MXs have rear knockouts allowing them to be mounted directly to the side of the enclosure without the need for additional mounting brackets. Mounting brackets are available for top installation of all MX models and for side installation less recent models. install the FXs. Start with the top FX. Hang the FX on the hanging screws, but continue to hold onto it. Loosely install four M6 X 20 mm screws, included with the FW-MP, one in each corner; tighten them when all four are installed and the FX is aligned. Install the remaining FX in the same manner. Bracket screw locations are shown below Screw locations for directly attaching an MX Charge Controller are shown below Figure 4: First FX installed AC side DC side Figure 13: MX Charge Controller mounting options Figure 5: Both FXs installed 13 6

After the FXs are installed, mount the AC chassis and the DC chassis in either order. Each ACA fits against the AC chassis Note: It is easier to remove the appropriate side knockouts from both the AC and DC chassis before installing either of them. If needed, the back knockouts must be removed before installation. Figure 6: Removing chassis side knockouts Figure 12: ACAs installed With both the AC Chassis and DC Chassis installed, the breaker brackets, AC din rail(s), and optional AC and DC breakers can be installed. Please see the individual Input/Output/Bypass Breaker (IOB) kit for instructions. When installing the AC chassis and the DC chassis: Either chassis can be installed first, the order is not important. Only loosely install the four screws securing each chassis. The screws will be tightened later. 7 12

Plastic bushing, DC side Installation of the AC Chassis and DC Chassis To install the chassis: Hold each chassis up to its respective mounting holes on the FW-MP. Place one M6 X 10mm machine screw (provided with the FW-MP) in each corner, tightening only enough to keep the chassis in place. AC side DC side Figure 11: DCA bushing Note: The DCA will be held firmly in place when the DCC (FX cover) is secured at the end of the installation. To install an ACA: Follow the separate ACA instructions for mounting to the FX. Line each ACA up with its conduit hole in the AC chassis. When aligned, move the AC chassis snug against the ACAs after the ACA installations. Press a 1 plastic bushing from inside the AC chassis out to the ACA through each previously removed knockout, sliding the AC chassis against the ACAs until snug. Install two M5 X 25mm screws (provided in ACA hardware kit) in each ACA and tighten securely. AC Chassis Mounting Holes Figure 7: Chassis Mounting Holes DC Chassis Mounting Holes 11 8

Corrugated Conduit installs between the chassis Line up either the ACA or DCA on its respective side of the FX, starting at the top. To attach a DCA, line up its two screw holes with the upper and lower right DCC screw holes. When lined up, loosely install the upper screw to hold the DCA in place. Slide the DC chassis over snug against the DCA (the screw slots in each chassis are oval-shaped to allow for movement) so the DCA lines up with the conduit adapter hole on the chassis. Install the plastic bushing from inside the chassis into the DCA (see Figure 11). After inserting the bushing into the top DCA, the remaining DCA will line up and the other bushing installed. With all the DCA s aligned with the DC chassis and the bushings installed, tighten the DC Chassis screws against the FW-MP. The single screws holding each DCA in place can be removed later when the DCC s are installed. Figure 8: AC and DC chassis mounted With each chassis loosely mounted, the AC Conduit Adapter (ACA) and DC Conduit Adapter (DCA) are installed on each FX. Remove the clear plastic AC cover and AC Conduit Plate from each FX. A single screw holds each DCA conduit adapter in place. Slide the DC chassis against each DCA and line it up with the plastic bushing. Clear plastic AC cover DC Wiring Cover (DCC) AC Conduit Plate Figure 9: FX Series Inverter/Charger Figure 10: DCA in place 9 10