Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Similar documents
Protistor size 14x51 gr 690VAC (IEC) / 700VAC (UL)

Protistor size 22x58 ar 690VAC (IEC) / 700VAC (UL)

Protistor size 2x72 and 2x73 ar 550 to 1250VAC (IEC)

Ferrule fuse-links 10x38 gg 400 to 690VAC

NH fuse-links gg VAC with striker size 0, 1, 2, 3, 4

Ferrule fuse-links 14x51 am 500 to 690VAC

Ferrule fuse-links 22x58 am 500 to 690VAC

Limitor - PD Back-up Fuses without Controlled Power Dissipation

L50QS SERIES HIGH-SPEED ROUND BODY FUSES

DC Square-body Fuses Sizes 120 to 123 gr 750V DC

Industrial fuses NFC-DIN industrial fuselinks gg and am curves from 0.16 to 1250 A

AMP-TRAP Form 101 A15QS

Semiconductor (AC) fuses

Semi conductor fuses PSC 690 V DIN 43620

ECNR/ECSR Class RK5 Dual-Element Time-Delay Fuses. Catalog Number ECNR (1-600A) 250Vac or Less Catalog Number ECSR (1-600A) 600Vac or Less

4. CIRCUIT BREAKERS. Functional Emergency Switching

JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B. R-Rated Fuses For Motor Circuit Protection Medium Voltage.

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

FLQ SERIES MIDGET (10x38mm) FUSES

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

1492-SP Supplementary Protectors

FUSERBLOC LMDC Fuse combination switches FUSERBLOC Live Maintenance DC

C E R T I F I C A T E O F C O M P L I A N C E

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

TRADITIONAL HIGH-SPEED FUSES

Miniature Circuit-Breaker IEC Series 8562

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

UL 489 DIN rail branch circuit breakers

60103 Circuit Breaker

10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Now even more application possibilities In all facets of semiconductor protection

TeSys IEC Contactors and Overload Relays

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

Bulletin 1489 Circuit Breakers. Selection Guide

Applying branch circuit breakers and supplementary protectors in North America

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Miniature Circuit Breakers and Supplementary Protectors. Contents

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

Applying branch circuit breakers and supplementary protectors in North America

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Magnetic and Hydraulic-Magnetic Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

UL 489 DIN Rail Miniature Circuit Breakers

Type 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016

ABL8RPS24030 regulated SMPS - 1 or 2-phase V - 24 V - 3 A

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

UL 489 DIN Rail Miniature Circuit Breakers

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

ABL8WPS24200 regulated SMPS - 3-phase V AC - 24 V - 20 A

Product Guide. UL 1077 DIN Rail Supplementary Protectors

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

TeSys protection components

SOLITRON MINI - With Integrated Heatsink Types RJ1A, RJ1B

Non-Fusible Disconnect Switches

Section 4 Ground-Fault Protection Devices

Selection Guide. Control Circuit and Load Protection

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

L70S SERIES HIGH-SPEED FUSE

C E R T I F I C A T E O F C O M P L I A N C E

ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Non-Fusible Disconnect Switches

Special Purpose Fuses

FS Series PV Modules Reverse Current Overload

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

IELR Rail-Mount Series Magnetic Circuit Protectors

MEDIUM VOLTAGE FUSES. POWR-GARD Fuse Datasheet. 2,400-38,000 VAC Current-Limiting

PS2328 Integrated Power. System

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

System Specifications

IELR Series

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Motor protection relays

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

SPXI SERIES IN-LINE SOLAR FUSE

Power supply module, bus connection module

Selection Guide. Control Circuit and Load Protection

Jtec 10kA Miniature Circuit Breaker

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Innovative Technology line filters and surge protectors

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

L50S SERIES HIGH-SPEED FUSE

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

Special Purpose Fuses

Cutler-Hammer. January 2001

Transcription:

690VAC (IEC) / 0VAC (UL) Protistor size 4x gr 690VAC (IEC) / 0VAC (UL) SEMICONDUCTOR PROTECTION FUSES IEC HIGH-SPEED CYLINDRICAL FUSE-LINKS AC PROTECTION FEATURES & BENEFITS IEC standard 60269-4 compliant UL 248- compliant gr class Clearing all overloads Improved safety and protection Enabling selective coordination among all Distribution circuit fuses With or without trip-indicator These Protistor size 4x have been designed to protect power semi conductors, complying with standard IEC 60269- and -4. They are extremely high interrupting rating fuses: 690VAC, with large band of ratings (current rating to 6A). Two models are existing: with or without trip-indicator. TECHNICAL DATA OVERVIEW Ampere Range (A) Size per Standard Speed/Characteristic I.R. AC (IEC) I.R. AC (UL) I.R. DC (UL) Rated voltage AC (IEC) Rated voltage AC (UL) Rated voltage DC (UL)... 6 A 4x gr 60 ka ka ka 690 V 0 V 0 V STANDARDS IEC 60269-4 UL Recognized UL 248- CCC GB 9.4 RoHS compliant EP.MERSEN.COM

690VAC (IEC) / 0VAC (UL) PRODUCT RANGE CP 4x gr with striker Catalog number Item number Rated voltage AC (IEC) Rated current In Pre-arcing I²t Clearing I²t at Rated Voltage Power dissipation at In Package Weight FR4GR69V2T D8 690 V 2 A 0.9 A²s.8 A²s. W g FR4GR69V4T E9 690 V 4 A 6. A²s A²s 2.9 W g FR4GR69V6T F80 690 V 6 A 8 A²s A²s 2 W g FR4GR69V8T G8 690 V 8 A 4. A²s 40 A²s 2.2 W g FR4GR69VT H82 690 V A 4. A²s 4 A²s 2.9 W g FR4GR69V2T J8 690 V 2 A.4 A²s 60 A²s 4. W g FR4GR69V6T K84 690 V 6 A. A²s 2 A²s 4.6 W g FR4GR69VT L8 690 V A 26.8 A²s 2 A²s 4.8 W g FR4GR69V2T M86 690 V 2 A 2. A²s 8 A²s.9 W g FR4GR69V2T Q89 690 V 2 A 96. A²s 0 A²s 6.9 W g FR4GR69V40T S9 690 V 40 A 2 A²s A²s. W g FR4GR69VT T92 690 V A 8 A²s 22 A²s 8. W g FR4GR69V6T V9 690 V 6 A 6 A²s 2900 A²s 2. W g CP 4x gr without striker FR4GR69V6 Catalog number Item number Rated voltage AC (IEC) Rated current In Pre-arcing I²t Clearing I²t at Rated Voltage Power dissipation at In Package Weight FR4GR69V X9 690 V A 0.2 A²s 0. A²s. W g FR4GR69V2 Y96 690 V 2 A 0.9 A²s.8 A²s. W g FR4GR69V4 Z9 690 V 4 A 6. A²s A²s 2.9 W g FR4GR69V6 A98 690 V 6 A 8 A²s A²s 2 W g FR4GR69V8 B99 690 V 8 A 4. A²s 40 A²s 2.2 W g FR4GR69V C 690 V A 4. A²s 4 A²s 2.9 W g FR4GR69V2 D 690 V 2 A.4 A²s 60 A²s 4. W g FR4GR69V6 E2 690 V 6 A. A²s 2 A²s 4.6 W g FR4GR69V F 690 V A 26.8 A²s 2 A²s 4.8 W g FR4GR69V2 G4 690 V 2 A 2. A²s 8 A²s.9 W g FR4GR69V2 H 690 V 2 A 96. A²s 0 A²s 6.9 W g FR4GR69V40 J6 690 V 40 A 2 A²s A²s. W g FR4GR69V K 690 V A 8 A²s 22 A²s 8. W g FR4GR69V6 L8 690 V 6 A 6 A²s 2900 A²s 2. W g EP.MERSEN.COM 2

690VAC (IEC) / 0VAC (UL) TIME CURRENT CHARACTERISTIC CURVES Size 4x gr -6A 00 00 00 Pre-arcing time (s) 0 0 0 0 0 A 2 A a = A2 = 0. B =.2 B2 = 0.8 Cf = 0.8 4 A 2 6 A 0. 0. 0. 0.2 0. 0.0 0.0 0.0 0.02 0.0 0.00 0.00 0.00 0.002 0.00 0.000 0.000 0.000 0.0002 0.000 2 RMS value of prospective current (A) +/- 8% 0 0 0 EP.MERSEN.COM

690VAC (IEC) / 0VAC (UL) TIME CURRENT CHARACTERISTIC CURVES Size 4x gr 8-6A Pre-arcing time (s) 00 00 00 0 0 0 0 0 8 A A 2 A 6 A A 2 A 2 A a = A2 = 0. B =.2 B2 = 0.8 Cf = 0.8 40 A A 2 0. 0. 6 A 0. 0.2 0. 0.0 0.0 0.0 0.02 0.0 0.00 0.00 0.00 0.002 0.00 0.000 0.000 0.000 0.0002 0.000 0 0 RMS value of prospective current (A) +/- 8% 0 0 0 00 00 00 EP.MERSEN.COM 4

690VAC (IEC) / 0VAC (UL) CUT-OFF CURRENT CHARACTERISTIC Size 4x gr -6A 0 0 lm = 2. lp 6 A 4 A Maximum peak let thru current Ic (A) 0 0 0 0 0 0 0 00 00 00 00 00 000 000 000 000 2 A A 000 Hz RMS symmetrical prospective current Ip (A) Size 4x gr 8-6A Maximum peak let thru current Ic (A) 00 lm = 2. lp 0 0 0 0 0 0 0 0 0 0 Hz RMS symmetrical prospective current Ip (A) 00 00 00 00 00 000 000 000 6 A A 40 A 2 A 2 A A 2 A A 8 A 000 000 EP.MERSEN.COM

690VAC (IEC) / 0VAC (UL) I²T MULTIPLIER COEFFICIENT Size 4x gr -6A, Clearing I²t and arcing time correction factor 0,9 0,8 0, 0,6 Applied AC voltage (V) 400 0 600 0 800 Size 4x gr 8-6A Clearing I²t and arcing time correction factor, 0,9 0,8 0, 0,6 0, 0,4 0, 0,2 0 Applied AC voltage (V) 400 0 600 0 800 EP.MERSEN.COM 6

690VAC (IEC) / 0VAC (UL) CHARACTERISTICS TOTAL I²T CURVE Size 4x gr -6A Operating I²t (A²s).0ms(.00ms).0ms(2.80ms) 8.ms(.60ms) 4.0ms(0.80ms).8ms(0.40ms) 0.9ms(0.ms) 0.4ms(0.ms) 6 A 4 A 2 A 2 0. 0. A 0. 0.2 0. 2 0 0 0 0 0 Hz RMS symetrical prospective current (Ip)(A) 00 00 00 00 00 000 000 000 000 000 0000 0000 e+06 EP.MERSEN.COM

690VAC (IEC) / 0VAC (UL) CHARACTERISTICS TOTAL I²T CURVE Size 4x gr 8-6A 00.0ms(.00ms).0ms(2.80ms) 8.2ms(.60ms) 4.6ms(0.80ms) 2.ms(0.40ms).4ms(0.ms) 0.8ms(0.ms) Operating I²t (A²s) 00 00 0 0 0 6 A A 40 A 2 A 0 0 2 A A 6 A 2 A A 8 A 0 0 0 0 0 00 00 00 Hz RMS symetrical prospective current (Ip)(A) 00 00 000 000 000 000 000 0000 0000 e+06 EP.MERSEN.COM 8

690VAC (IEC) / 0VAC (UL) POWER DISSIPATION Size 4x gr -6A 0,8 Correction factor for power dissipation 0,6 0,4 0,2 0 40 60 80 90 % of rated current Size 4x gr 8-6A Correction factor for power dissipation 0,8 0,6 0,4 0,2 0 40 60 % of rated current 80 90 EP.MERSEN.COM 9

690VAC (IEC) / 0VAC (UL) DIMENSIONS CP 4x gr with striker (2) CP 4x gr without striker (22) +0.6-0..2 Visual indicator Ø 4. ± 0. +0.6 - Ø 4. ± 0..2.2.2 Dimensions in mm Dimensions in mm EP.MERSEN.COM