AS-CVTPROx00-0 Zone Bus/N2 Bus Interface Converter

Similar documents
Auxiliary Gear. Auxiliary Gear...2. Introduction Key Concepts... 3

TECHNICAL BULLETIN. Auxiliary Gear. Introduction Page *3. Actuators 5 AS-CBLPRO-2 9 AS-CBLCON AS-CVTPROx00-0 *15

N2 Dialer Module. Features and Benefits

VAV Modular Assembly (VMA) 1410/1420

Modular Room Control (MRC) Series Expansion Board

TC-9102 Terminal Controller

M-Tool. Features and Benefits System Configuration and Project Management. Allows fast adjustment and commissioning of systems

Variable Air Volume Modular Assembly (VMA) 1400 Series

Medium User Interface (MUI) Version 3

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

DX-9100 Digital Controller, Version 2

FX Input/Output (I/O) Modules XM07 and XM14

Extended Digital Controller

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Metasys Checkout Tool User s Guide

S66 Series Electronic Fan Speed Control

LN Series Remote Input/Output (I/O) Modules

FX40 Supervisory Controller

Metasys System Configuration Tool (SCT)

TM-2100 Series Room Command Module

Polling the N2 Network or Zone Bus for Devices

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

Metasys N1 Network Integration

Lab and Central Plant Controller

TM-2100 Series Room Command Module

FX Tools Express Software Package

FXVMA Variable Air Volume (VAV) Box Controller

Network Control Engine Catalog Page

Metasys Integrator Northern Application

FX06 Field Controller

LX Series Remote Input/Output (I/O) Controller

Smart Equipment Controls (SEC)

Fiber optic converter audio and CAN TA OPERATION MANUAL

P216 Series Condenser Fan Speed Controller

LN Series Communicating Sensors

NIE59 Network Integration Engine Figure 1: NIE59 Network Integration Engine

Johnson Controls ComBus Quick Tester

FX14 Field Controller

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

RCM Room Command Module New Style

HE-6800 Series Humidity Transmitters with Temperature Sensor

Installation Instructions

Introduction to the N30 Supervisory Controller

TC-8900 Controller Units with PM-8900 Power Modules

Software Details and Hardware Connections

Network Control Engine

FX Tools Software Package - FX CommPro N2 User s Guide

Application and Data Server (ADS) Lite-A System Catalog Page

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

N30 Supervisory Controller Installation

LCS85 Turnkey User's Guide Part No , Rev. F Software Release 6.1 Issued June 17, 2013 Supersedes January 30, 2011

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued June 2018

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

Metasys Smoke Control Wiring

LONWORKS Compatible DX-9200 Digital Controller

Metasys Integrator Multistack Application

Input/Output Module (IOM) Series Catalog Page

Features Communication Using Commonly Accepted IT Standards, Including Web Services, at the Automation and Enterprise Level Web-Based User Interface

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Installing the DX LCD Display

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

Network Integration Engine (NIEx9) for Third-Party Integrations Catalog Page

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Metasys Integrator United Power Application

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

XT-9100 Technical Bulletin

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

Field selectable application type and room module series, via dip-switches on controller

5401 and 5402 Digital I/O Modules

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

ENGINEERING SPECIFICATION 90 WATT POWER SUPPLY PART NUMBER PA P1

Models HP Z VR Backpack G1 Dock

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

* * Agilent Power Distribution Unit (PDU) Installation Guide

ETM-2040 Service Manual

P216. Condenser fan speed controller. Product bulletin. Features

2U Congestion Alert Rack Insert for UK

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

FX Tools Software Package - FX Builder Express User Guide

Discontinuation of N2 and Select LONWORKS Field Controllers and Associated Products. Notice of Plans for Long-Term Support of N2 Devices.

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

clarity 3 Programmable Controller

Rotary version, three-position control

PHS Series. PowerHUBB Node - Satellite

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

4170 POS System Installation Guide

EP/2 Installation Instructions

Network Automation Engine Catalog Page MS-NAE35xx-x, MS-NAE45xx-x, MS-NAE55xx-x, NAE Software Release 8.1 Issued February 2017

Allure EC-Smart-Comfort Series

ELAN DIGITAL SYSTEMS LTD.

An ISO-9001 Certified Company

PTDT V Quick Installation & Reference Guide. Ver Battery Management Solutions by. PowerDesigners

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

Metasys Integrator GE Lighting Application

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

Transcription:

Installation Instructions Issue Date June 11, 2002 AS-CVTPROx00-0 Zone Bus/ Interface Converter Ports The back of the CVTPRO (Figure 1) has ports for connection to a Personal Computer (PC) and the Palm handhelds, power input source, and the Zone Bus/ RJ11 jack. Cabling Figure 3 shows the 6-pin phone plug end of the N2 cable used by the CVTPRO for communication. For Zone Bus communication, always use standard Zone Bus cables. Blue (N2+) White (N2-) Red (N2 REF) phonewire Figure 3: N2 Cable 6-Pin Phone Plug Zone Bus/ RJ11 Jack 6-Pin Serial Port for Palm m1xx or m5xx Devices or PC Power Input cvtdorsal Figure 1: CVTPRO Back The front of the CVTPRO (Figure 2) shows the mating connector for a Palm III, Palm V adapter, or Palm VII. Green and yellow Light-Emitting Diodes (LEDs) display the N2 communication status of the unit relative to the field device. The red LED shows power status. Connector for Palm V Adapter, Palm III, or Palm VII Yellow LED (Receiving) Green LED (Transmitting) Red LED (Power) Pin Signal 1 N2+ 2 Zone Bus Power 3 GND 4 N2 Ref 5 Zone Bus Signal 6 N2- n2zone Figure 4: Zone Bus/ RJ11 Jack Pinout! CAUTION: Risk of Equipment damage. Check all wire connections. Improperly connected wires result in permanent damage to the CVTPRO unit. Battery Cover cvtfront Figure 2: CVTPRO Front 2002 Johnson Controls, Inc. 1 Part No. 24-9544-0, Rev. B www.johnsoncontrols.com

Table 1: Cables Included with the CVTPRO To Connect the CVTPRO To: PC via RS232 Use This Cable: CVTPRO serial cable (18 inches/457 mm) Controller via the Zone Bus 8-pin RJ45 to 6-pin RJ11 phone cable (6 ft/1.8 m) Controller via the 4-pin N2 socket/3-pin N2 plug to 6-pin RJ11 phone cable (6 ft/1.8 m) Note: Remove the 4-pin N2 socket from the cable and use the bare wires to connect to N2 screw terminal devices. Controller Zone Bus (via TE-6x00/ 6-pin to 6-pin RJ11 phone cable (6 ft/1.8 m) TMZ sensor) Table 2: Connections to Palm Devices To Connect the CVTPRO To: Use: In This Sequence Palm III and Palm VII Devices Nothing Palm III/Palm VII CVTPRO Palm V Device Dock V Pro Adapter 1 Palm V Dock V Pro Adapter CVTPRO Palm m100 and m105 Devices Palm HotSync Cable 2 Palm m100/m105 Palm HotSync Cable null Null Modem Adapter 2 modem adapter CVTPRO Serial Cable CVTPRO Palm m125, m130, and m5xx Devices CVTPRO Serial Cable 3 Belkin Serial Sync Cable 2 Null Modem Adapter 2 CVTPRO Serial Cable 3 Palm m125/m130/m5xx Belkin Serial Sync Cable null modem adapter CVTPRO Serial Cable CVTPRO 1 The Dock V Pro is available from Solvepoint Corporation at www.palmdock.com and local retailers. 2 Order through Johnson Controls e-purchasing (ITAS). See Table 3. 3 Included with the CVTPRO unit. Table 3: CVTPRO Part Numbers Part Number Description AS-CVTPRO100-0 AS-CVTPRO200-0 AS-CVTPRO-700 AS-CVTCBL-700 Dock V Pro adapter** F3X1082-03* ME213* P10701U* Zone Bus/ Interface Converter with 120VAC/3VDC power adapter (North American version) Zone Bus/ Interface Converter without power adapter (European version) CVTPRO unit without cables or case Replacement set of cables used with the CVTPRO converter Adapter to connect the CVTPRO to a Palm V device Belkin Serial Sync Cable for use with CVTPRO and Palm m125/m130/m5xx Devices Black Box Null Modem Adapter for use with CVTPRO and Palm m100/m105/m125/m130/m5xx Devices Palm HotSync Cable for use with CVTPRO and Palm m100/m105 Devices * These are the manufacturer s code numbers, not Johnson Controls code numbers. Order through Johnson Controls e-purchasing (ITAS). ** The Dock V Pro is available from Solvepoint Corporation at www.palmdock.com and local retailers. 2 AS-CVTPROx00-0 Zone Bus/ Interface Converter Installation Sheet

P A A P L ME IC AT N U I O N S e FIND P P L M IC E N AT IO U S N 1 5 FIND Connection Figure 5 is a diagram of the connections between the CVTPRO and other devices. Refer to Table 1 and Table 2 for more information on cables and Palm devices. See Figure 6 and Figure 7 for more detail about connections. Palm III, Palm V with Dock V PRO Adapter, or Palm VII 1, 2 a b cd e 2 3 4 CALCULA T O R TE-6x00/TMZ Room Sensor RJ11 Jack, 6-Pin External Power 3 1 Personal Computer or DB9 Port CVTPRO Serial Cable DB9 Connector CVTPRO Serial Port Zone Bus/ RJ11 Jack 6-pin or or Zone Bus Compatible Controller RJ45 Jack, 8 Pin Interface, 4-Pin N2 Socket/ 3-Pin N2 Plug with Tab a b c d 1 23 4 5 CALCULA TOR Palm m1xx or m5xx (with additional connectors) See Table 2. Notes: 1. Do not connect the CVTPRO to the Palm device and laptop/pc at the same time. 2. Unplug the Palm from the CVTPRO when not in use (conserves battery power). 3. The CVTPRO200-0 (European version) does not ship with an external power adapter. cvtschematic Figure 5: Overview of Possible CVTPRO Connections AS-CVTPROx00-0 Zone Bus/ Interface Converter Installation Sheet 3

Connecting the CVTPRO to a Controller with N2 Screw Terminals To connect the CVTPRO to a controller with screw terminals (Figure 6): 1. Disconnect the N2 wires from the controller and temporarily protect the bare wires with insulating tape. 2. Remove the 4-pin N2 socket from the CVTPRO N2 cable to expose the three wires. 3. Connect the N2+ (blue), N2- (white), and Ref (red) wires to the controller. 4. Connect the CVTPRO N2 cable 6-pin RJ11 phone plug end to the CVTPRO. CVTPRO N2 Cable 3-Pin N2 Plug To scan the : 1 Disconnect the from the N2 master controller. 2 Remove the N2 plug (with attached N2 wires) from the controller (4-pin on the VMA, 3-pin on other controllers). 3 Connect the CVTPRO 4-pin N2 socket to the 4-pin or 3-pin controller N2 plug from Step 2. Observe polarity (N2+ [blue], N2- [white] Ref [red]). 4 Connect the 6-pin RJ11 phone plug of the CVTPRO N2 cable to the CVTPRO. VMA To CVTPRO Converter Ref (Red) N2- (White) N2+ (Blue) Wire Directly to Controller cvtunt Figure 6: CVTPRO N2 Connection to Controllers with Screw Terminals CVTPRO N2 Cable 3-Pin N2 Plug S R N N H E 2 2 L F - + D Use these components to talk to the controller. Connecting the CVTPRO to a Controller with a Removable N2 Plug Note: Figure 7 shows the possible connections with a Variable Air Volume Modular Assembly (VMA) (controller with a removable N2 plug). To connect the CVTPRO to a controller with a removable N2 plug: 1. Remove the 4-pin N2 plug from the controller. 2. Plug the CVTPRO N2 plug into the controller (4-pin on the VMA, 3-pin on other controllers). Observe polarity [N2+ (blue), N2- (white), Ref (red)]. 3. Connect the 6-pin RJ11 phone plug of the CVTPRO N2 cable to the CVTPRO. To Next N2 Device To CVTPRO Converter 4-Pin N2 Socket 4-Pin N2 Plug Unplugged from the VMA N2 REF N2- N2+ SH LD REF N2- N2+ N2+ N2- N2 REF To Next N2 Device Use these components to scan the. CVTVMA Figure 7: CVTPRO N2 Connection to a VMA with Removable N2 Plugs 4 AS-CVTPROx00-0 Zone Bus/ Interface Converter Installation Sheet

Compatibility Table 4 lists compatible tools, Operating Systems (OSs), and controllers used over the Zone Bus and with the CVTPRO converter. Compatible controllers include the Air Handling Unit (AHU), Unitary Controller (UNT), Variable Air Volume Controller (VAV), Network Dialer Module (NDM), and VMA. Table 4: Compatibility Chart Tool Bus Operating System Compatible Controller HVAC PRO Software (part of M-Tool Release 5.0 or later) Zone Bus Windows 98 SE/Windows NT / Windows 98 SE OS AHU1xx UNT1xx UNT11xx VAV1xx VMA14x0 Zone Bus Windows NT/ VMA14x0* VBT1400 Zone Bus Palm Personal Digital Assistant (PDA) with OS Version 3.5 or later VMA14x0 VBT1200 Zone Bus Palm PDA with OS Version 2.x or later VMA12x0 GX-9100 Software Configuration Tool (part of M-Tool Release 5.0 or later) Windows 98 SE/Windows NT/ XTM Configuration Tool Windows 98 SE/Windows NT/ NDM Configuration Tool Windows 98 SE/Windows NT/ DT-9100 DX-9100 XP91xx XTM-905 (XPx-xxx) XT9100 XTM-105 (XPx-xxx) Note: The CVTPRO converter is not compatible with Zone Terminal Units (ZTUs). For ZTUs, use the CBLPRO-2 converter. See the Auxiliary Gear Technical Bulletin (LIT-6363080) for details on Johnson Controls converters. * When using the VMA14x0 with HVAC PRO software over the Zone Bus with Windows NT or Windows 2000 software, a Device Conflict box appears whenever the user attempts an operation (for example, upload or download). To bypass the box, select Yes or No and the box disappears. The selected operation continues as expected. NDM AS-CVTPROx00-0 Zone Bus/ Interface Converter Installation Sheet 5

Technical Specifications Product AS-CVTPROx00-0 Zone Bus/ Interface Converter AS-CVTPRO100-0 with 120VAC/3VDC power adapter (North American version) AS-CVTPRO200-0 without power adapter (European version) Power Requirements Zone Bus: Controller supplied power (standalone or via thermostat) (24 VAC or 15 VDC [for VMA applications]) : External Adapter 120 VAC to +3 VDC 200 ma (included with CVTPRO in North America only) or Batteries (2 AAA) (not included) Agency Listings UL 916 Plastic Housing Meets UL 94-5V CSA 22.2 No.205 FCC Part 15m Subpart B, Class A CE Mark: EN50081-1 (Electromagnetic Compatibility, EN55011, Class B) EN50082-2 (Electromagnetic Compatibility, EN61000-3-2 and EN61000-3-3) Ambient Operating Conditions Ambient Storage Conditions Shipping Weight 0 to 50 C (32 to 122 F) 20-80% RH (Relative Humidity) 30 C (86 F) Maximum Dew Point -40 to +60 C (-40 to 140 F) 5-95% RH 30 C (86 F) Maximum Dew Point 0.227 kg (0.5 lb.) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Refer to the Auxiliary Gear Technical Bulletin (LIT-6363080) for necessary information on ordering, operation, and performance specifications of this product. Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 Printed in U.S.A. www.johnsoncontrols.com 6 AS-CVTPROx00-0 Zone Bus/ Interface Converter Installation Sheet