MT1810A 4 Slot Chassis Operation Manual

Similar documents
EOS-6000 Series Optical A/B Switch User Manual DC Version

MP1800A Signal Quality Analyzer Installation Guide

B63/ NS MS. EtherNet/IP LINK

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

DS-1H05 Ethernet-over-Coax Extender. User Manual

Thin clients JC500X - 1 Reference guide

MP8931A Bit Error Rate Tester Operation Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

HD Mini IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.2.0

MP1861A 56G/64Gbit/s MUX Operation Manual

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

H3C S1016/1024 Ethernet Switch User Manual

POWER SUPPLY UNIT PSU-3

User s Manual Power Supply IM E. 5th Edition

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

TPC25 active crossover. user manual

MC 11 EB-2 Power supply cabinet with external bus, AC version

RZ5/RZ5D/RZ6 Processor. Operator s Manual

INSEBO2IRF 2.1MP 1080P IP Eyeball Camera with IR

1-36V, 0-3A DC Power Supply

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Dahua HD IR Vari-Focal Fixed Network Camera. Quick Start Guide

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

Table of Contents. 3.1 Front/Rear Panel and User Interface Front Panel Rear Panel User Interface...

1395 Node Adapter Board Troubleshooting

Installation Job Aid for Ethernet Routing Switch 3600 Series

Model 7705 Control Module

CS2 DMX Distribution Splitter

Model VC-SHIELD Shield Box

Blue Weapon Laser. User manual UK. Version 1.0

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

PA Series. Available in 6.0MP and 8.0MP

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

dedicated KVM switch and rackmount screen technology User Manual CV-1201D DVI-D KVM Designed and manufactured by Austin Hughes

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

A Series HD Wi-Fi Network Camera. Quick Start Guide. Version 1.0.1

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

Available in 2.0MP, 4.0MP and 8.0MP variants

High Precision Quad Output DC Power Supply

RZ2 BioAmp Processor. Operator s Manual

Installation Job Aid for Ethernet Routing Switch 5900 Series

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

PX Series Balances. Quick Start Guide. Please download the user manual from

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

Universal AC Power Source + AC Power Analyzer

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

HD Analog Camera User s Manual

Druck DPI 620 advanced modular calibrator

dedicated KVM switch and rackmount screen technology User Manual CV-801 PS/2 DB-15 KVM Designed and manufactured by Austin Hughes

Dahua HD Fixed-focal Pinhole Network Camera

LVN5200A-R2, rev. 1, Hardware Installation Guide

Manual Version: V1.01. Network Bullet Cameras Quick Guide

PF LED Profile. User Manual

Spectrum Laser. User manual UK. Version 1.0

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Hardware Manual. intelligent Touch Controller

Version /11/2015. User Manual. PowerLine AV HD Gigabit Passthrough Kit DHP-P601AV

VTPC190V / VS / VDC / VSDC

Model : ON-PS3016G. 16 Port 10/100/1000Mbps Gigabit + 2 Gigabit SFP Uplink Unmanaged PoE Switch

7032 Digital-Analog Multimeter

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Available in 2.0MP, 4.0MP, 6.0MP and 8.0MP, with 2.8mm and 3.6mm lenses.

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

User Manual. AN A GPON Optical Network Unit. Version: A. Code: MN Date: December 2011

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

TVAC25100 TVAC25110 User manual

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Junos WebApp Secure 5.0 Hardware Guide

4170 POS System Installation Guide

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

LED Pixel Rail Drive 640 controller. user manual

DS-2 RF DMX dimmer. user manual

Economy Single Channel Output DC Power Supply

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Manual of DS-9600NI-H8 DS-9600NI-H8. Installation Manual UD.7L0202A1730B01

FT-20 Fire Training Fog Machine User Manual English

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

USER S MANUAL Linear Programmable DC Power Supply APS

UV Power Flood. User Manual. Order code: EQLED029

MS2850A-053 External Interface for High Speed Data Transfer PCIe MS2850A-054 External Interface for High Speed Data Transfer USB3.

2260B-RMK-Series Rack Mount Kit

HV-CS kv Edge Mount Triaxial Jack

WA4204-G2/G3 and WA4304-G2/G3

APT20. User Manual.

Type Quickstart

FT-20 Fire Training Fog Machine User Manual English

HDMI 1.3 Matrix Switch Receiver over CAT5 with IR Pass-Through

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

E-37-V Dome Network Camera. Quick Start Guide

Z-350 FAZER USER MANUAL

1 Channel Strobe Controller ORDERCODE 40226

UP-1-1 Channel Dimmer. User manual. dimmer pack

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

SUBWOOFER SYSTEM YST-MSW10

1. Safety Precautions (Read these precautions before use.)

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Transcription:

MT1810A 4 Slot Chassis Operation Manual Seventh Edition For safety and warning information, please read this manual before attempting to use the equipment. Additional safety and warning information is provided within the MT1810A 4 Slot Chassis Installation Guide. Please also refer to this document before using the equipment. Keep this manual with the equipment. ANRITSU CORPORATION Document No.: M-W2746AE-7.0

Safety Symbols To prevent the risk of personal injury or loss related to equipment malfunction, Anritsu Corporation uses the following safety symbols to indicate safety-related information. Ensure that you clearly understand the meanings of the symbols BEFORE using the equipment. Some or all of the following symbols may be used on all Anritsu equipment. In addition, there may be other labels attached to products that are not shown in the diagrams in this manual. Symbols used in manual DANGER This indicates a very dangerous procedure that could result in serious injury or death if not performed properly. WARNING CAUTION This indicates a hazardous procedure that could result in serious injury or death if not performed properly. This indicates a hazardous procedure or danger that could result in light-to-severe injury, or loss related to equipment malfunction, if proper precautions are not taken. Safety Symbols Used on Equipment and in Manual The following safety symbols are used inside or on the equipment near operation locations to provide information about safety items and operation precautions. Ensure that you clearly understand the meanings of the symbols and take the necessary precautions BEFORE using the equipment. This indicates a prohibited operation. The prohibited operation is indicated symbolically in or near the barred circle. This indicates an obligatory safety precaution. The obligatory operation is indicated symbolically in or near the circle. This indicates a warning or caution. The contents are indicated symbolically in or near the triangle. This indicates a note. The contents are described in the box. These indicate that the marked part should be recycled. MT1810A 4 Slot Chassis Operation Manual 27 November 2006 (First Edition) 10 October 2014 (Seventh Edition) Copyright 2006-2014, ANRITSU CORPORATION. All rights reserved. No part of this manual may be reproduced without the prior written permission of the publisher. The contents of this manual may be changed without prior notice. Printed in Japan ii

Notes On Export Management This product and its manuals may require an Export License/Approval by the Government of the product's country of origin for re-export from your country. Before re-exporting the product or manuals, please contact us to confirm whether they are export-controlled items or not. When you dispose of export-controlled items, the products/manuals need to be broken/shredded so as not to be unlawfully used for military purpose. iii

iv

About This Manual A testing system combining an MP1800A Signal Quality Analyzer or MT1810A 4 Slot Chassis mainframe, module(s), and control software is called the Signal Quality Analyzer Series. The operation manuals of the Signal Quality Analyzer Series consist of separate documents for the installation guide, the mainframe, remote control operation, module(s), and control software, as shown below. Installation Guide Configuration of Signal Quality Analyzer Series Operation Manual indicates this document. Installation guide, from module installation to the start of use. The Installation Guide varies depending on the mainframe used. Mainframe Operation Manual Describes basic operations of the mainframe. The Mainframe Operation Manual varies depending on the mainframe used. MT1810A 4 Slot Chassis Operation Manual Describes panels and their maintenance. Remote Control Operation Manual Describes remote control using the GPIB interface and LAN interface. Module Operation Manual Operation manual for the module. The Module Operation Manual varies depending on the module(s) used. Control Software Operation Manual Operation manual of the software that controls the Signal Quality Analyzer Series. I

Table of Contents About This Manual... I Chapter 1 Overview... 1-1 1.1 Product Overview... 1-2 1.2 Product Composition... 1-3 1.3 Specifications... 1-5 Chapter 2 Preparations... 2-1 2.1 Measures Against EOS and ESD... 2-2 Chapter3 Panels and Connections... 3-1 3.1 Front Panel... 3-2 3.2 Rear Panel... 3-3 Chapter 4 Maintenance... 4-1 4.1 Daily Maintenance... 4-2 4.2 Cautions on Storage... 4-2 4.3 Transportation... 4-3 4.4 Calibration... 4-3 4.5 Disposal... 4-4 II.

Chapter 1 Overview This Chapter provides an overview and the specifications of the MT1810A 4 Slot Chassis (hereinafter, referred to as MT1810A ). 1.1 Product Overview... 1-2 1.2 Product Composition... 1-3 1.2.1 Standard composition... 1-3 1.2.2 Options... 1-3 1.2.3 Application parts... 1-4 1.3 Specifications... 1-5 1-1

Chapter 1 Overview 1.1 Product Overview Various plug-in modules (hereinafter, referred to as module ) can be installed into the MT1810A, to support research, development and production of module devices for the optical communication market or interconnection within a Gbit/s class high-speed device. The MT1810A is also useful for research and development for the next-generation communication market, including optical packet transmission. Up to 4 modules can be installed into the MT1810A. For the MU181020A 12.5 Gbit/s PPG and MU181040A 12.5 Gbit/s ED, among the installable modules, the number of controllable modules can be increased to 2 or 4 by selecting an optimal option to the MT1810A. As a way of reducing cost, the display and control parts have been omitted from the MT1810A, which is then controlled by the MX180000A Signal Quality Analyzer Control Software installed in the external control PC. Remote control by the control PC can also be performed via the GPIB or LAN interface. For the latest information on the modules that can be mounted on the main unit, refer to the Anritsu homepage (http://www.anritsu.com). 1-2

1.2 Product Composition 1.2 Product Composition 1.2.1 Standard composition Table 1.2.1-1 shows the standard composition of the MT1810A. For the latest information, refer to the Anritsu homepage (http://www.anritsu.com/en-us/products-solutions/products/mp1800a.aspx ). Table 1.2.1-1 Standard composition of MT1810A Item Model Product Q ty Remarks Main unit MT1810A 4-Slot Chassis 1 Accessories Z0306A Wrist strap 1 Z0897A Operation Manual 1 CD-ROM Z0918A MX180000A Software CD 1 CD-ROM - Power Code (13A) 1 J1109B LAN cable 1 CAT5, Crossover, 5 m B0575A MT1810A protective cover 1 G0342A ESD Discharger 1 J1627A GND connection cable 1 1.2.2 Options Table 1.2.2-1 shows the options for the MT1810A. All options are sold separately. Table 1.2.2-1 Options installed at shipment Model Product Remarks MT1810A-x14 2-slot for PPG and/or ED Enables control of 2 units of the MU181020A 12.5 Gbit/s PPG or MU181040A 12.5 Gbit/s ED in total. MT1810A-x15 4-slot for PPG and/or ED Enables control of 4 units of the MU181020A 12.5 Gbit/s PPG or MU181040A 12.5 Gbit/s ED in total. MT1810A-032 32Gbit/s PPG and/or ED Support Enables control of 4 units of the MU183020A 28G/32Gbit/s PPG, MU183021A 28G/32Gbit/s 4ch PPG, MU183040A 28G/32Gbit/s ED, or MU183041A 28G/32Gbit/s 4ch ED in total. 1-3

Chapter 1 Overview 1.2.3 Application parts Table 1.2.3-1 shows the application parts for the MT1810A. All application parts are sold separately. Table 1.2.3-1 Application parts Model Product Remarks J0008 GPIB connection cable, 2.0 m 2 m W2746AE MT1810A 4 Slot Chassis Operation Manual Printed version W2748AE MT1810A 4 Slot Chassis Installation Guide Printed version J1109B LAN cable CAT5, crossover, 5 m B0593A Blank panel B0587A Rack mount kit 1-4

1.3 Specifications 1.3 Specifications Table 1.3-1 MT1810A specifications No. Item Specifications 1 1.1 1.2 1.3 1.4 1.5 Electrical performance Functions Remote interface Mainframe ID GPIO Maintenance 2 Environmental performance Power supply* Buzzer which sounds during measurement 10 BASE-T, 100 BASE-TX Ethernet (dedicated port for external control PC) Used to identify the MT1810A units when multiple (up to 4) MT1810A units are connected. Reserved connectors. This function is currently not available Connector for maintenance. Do not connect this connector. AC 100 to 120 V, 200 to 240 V (automatic switching between 100- and 200-V systems), 50 to 60 Hz 450 Vac or less +5 to +40 C (without condensation) Power consumption Operating temperature range Operating humidity range 20 to 80% Storage temperature range 20 to +60 C (Recommended storage temperature range: +5 to +30 C) Storage humidity range 20 to 80% (Recommended storage humidity range: 40 to 75%) 3 Mechanical measurements Dimensions Mass 350 mm (W) 132.5 mm (H) 400 mm (D) (Protrusions excluded) 13.0 kg (excluding modules and blank panels) *: Operating voltage: within the range of +10% to 15% from the rated voltage Refer to the Anritsu homepage (http://www.anritsu.com), for information on options and application parts which can be installed into the MT1810A. 1-5

Chapter 1 Overview 1-6.

Chapter 2 Preparations This chapter describes preparations for using MT1810A. 2.1 Measures Against EOS and ESD... 2-2 2.1.1 How to use the GND connection cable... 2-2 2.1.2 How to use the ESD Discharger... 2-3 2-1

Chapter 2 Preparations 2.1 Measures Against EOS and ESD This section describes how to prevent MT1810A from being damaged by electrical over-stress (EOS) or electrostatic discharge (ESD). 2.1.1 How to use the GND connection cable There is a risk of damaging MT1810A due to EOS if MT1810A and other peripheral equipment (including experimental circuits) are not connected to the common ground. When connecting MT1810A and other peripheral (including experimental circuits), connect other peripheral equipment to the ground terminal of MT1810A s chassis with the GND connection cable before connecting the I/O connectors. MT1810A Other Peripheral Equipment Figure 2.1.1-1 How to Use the GND Connection Cable 2-2

2.1 Measures Against EOS and ESD 2.1.2 How to use the ESD Discharger There is a risk of damaging MT1810A if the coaxial cable you connect to MT1810A is charged electrostatically. To prevent MT1810A from being damaged by ESD, remove electrostatic charges from the cable by using the ESD Discharger before cabling the connectors. The ESD Discharger can be used with one of SMA connector (and its compatible connector) and V connector (and its compatible connector). Figure 2.1.2-1 How to Use the ESD Discharger 2-3

Chapter 2 Preparations 2-4.

Chapter 3 Panels and Connections This Chapter describes panels and connections of the MT1810A. 3.1 Front Panel... 3-2 3.2 Rear Panel... 3-3 3-1

Chapter 3 Panels and Connections 3.1 Front Panel 3 4 1 5 2 6 Fig. 3.1-1 Front panel Table 3.1-1 Front panel No. Name Function 1 Power switch Turns the power to the MT1810A on/off. When this switch is turned on, power is turned on and the Power LED above the switch lights. 2 Earth jack Connects to the wrist strap during operation, as a countermeasure against static electricity. Be sure to use the wrist strap when using the MT1810A. 3 Module slots Up to 4 modules can be installed into the MT1810A. See MT1810A 4 Slot Chassis Installation Guide for how to install/remove the modules to/from the slots. 4 Mainframe ID Used to identify the MT1810A units when multiple (up to 4) MT1810A units are connected. Refer to MT1810A 4 Slot Chassis Installation Guide for details on 4-unit serial connection. 5 Volume Volume for measurement error sound 6 Ethernet connectors Two RJ45 Ethernet connectors are provided. A 10 BASE-T or a 100 BASE-TX cable can be used. The internal hub provides the same function to the two connectors. In addition to direct connection, the control PC can be connected to the MT1810A via an Ethernet interface device. Note that the IP address for the MT1810A is fixed, so it cannot be directly connected to a network. Each connector has two LEDs. The left one indicates the Link/Act status. The connector is in Link status when the left LED is on, No Link status when it is off, and Act status when it blinks. The right LED indicates the collision status. When it is off, collision is not detected. It blinks when collision is detected. 3-2

3.2 Rear Panel 3.2 Rear Panel 1 2 3 Fig. 3.2-1 Rear panel Table 3.2-1 Rear panel No. Name Function 1 GPIO Reserved connector. Currently not available. 2 Maintenance Maintenance connector. Do not use. 3 Inlet Connect to a 100 to 120 Vac or to a 200 to 240 Vac power supply via the 3-pin power cord. 3-3

Chapter 3 Panels and Connections 3-4.

Chapter 4 Maintenance This Chapter describes the maintenance of the MT1810A. 4.1 Daily Maintenance... 4-2 4.2 Cautions on Storage... 4-2 4.3 Transportation... 4-3 4.4 Calibration... 4-4 4.5 Disposal... 4-4 4-1

Chapter 4 Maintemance 4.1 Daily Maintenance Wipe off any external stains with a cloth damped with diluted mild detergent. Vacuum away any accumulated dust or dirt with a vacuum cleaner. Tighten any loose parts fixed with screws, using the specified tools. 4.2 Cautions on Storage Wipe off any dust, soil, or stain on the device prior to storage. Avoid storing the device in any of the following locations: In direct sunlight for extended periods Outdoors In excessively dusty locations Where condensation may occur In liquids, such as water, oil, or organic solvents, and medical fluids, or places where these liquids may adhere In salty air or in place chemically active gases (sulfur dioxide, hydrogen sulfide, chlorine, ammonia, nitrogen dioxide, or hydrogen chloride etc.) are present Where toppling over may occur In the presence of lubricating oil mists At low atmospheric pressure In the presence of frequent vibration or mechanical shock, such as in cars, ships, or airplanes Under the following temperature and humidity conditions: Temperature range of 20 C or 60 C Humidity range of 85% Recommended storage conditions In addition to the abovementioned storage cautions, the following environment conditions are recommended for long-term storage. Temperature range of 5 to 30 C Humidity range of 40 to 75% Slight daily fluctuation in temperature and humidity 4-2

4.3 Transportation 4.3 Transportation Use the original packing materials, if possible, when packing the MT1810A for transport. If you do not have the original packing materials, pack the device according to the following procedure. When handling the MT1810A, always wear clean gloves, and handle it gently so as not to damage it. <Procedure> 1. Use a dry cloth to wipe off any stain or dust on the exterior of the MT1810A. 2. Check for loose or missing screws. 3. Provide protection for structural protrusions and parts that can easily be deformed, and wrap the MT1810A with a sheet of polyethylene. Finally, cover with moisture-proof paper. 4. Place the wrapped MT1810A into a cardboard box, and tape the flaps with adhesive tape. Furthermore, store it in a wooden box as required by the transportation distance or method. 5. During transportation, place it under an environment that meets the conditions described in Section 4.2 Cautions on Storage. 4-3

Chapter 4 Maintemance 4.4 Calibration Regular maintenance such as periodic inspections and calibration is essential for the Signal Quality Analyzer Series for long-term stable performance. Regular inspection and calibration are recommended for using the Signal Quality Analyzer Series in its prime condition at all times. The recommended calibration cycle after delivery of the Signal Quality Analyzer Series is twelve months. If you require support after delivery, contact an Anritsu Service and Sales office. Contact information can be found on the last page of the printed version of this manual, and is available in a separate file on the CD version. We may not provide calibration or repair if any of the following cases apply. Seven or more years have elapsed after production and parts for the instrument are difficult to obtain, or it is determined that reliability cannot be maintained after calibration and repair due to significant wear. Circuit changes, repair, or modifications are done without our approval. It is determined that the repair cost would be higher than the price of a new item. 4.5 Disposal Confirm the notes described in the Signal Quality Analyzer Series Installation Guide and observe national and local regulations when disposing of the MT1810A. Before disposal, dismantle or physically destroy any non-volatile memory media in the MT1810A to ensure that data in memory cannot be recovered by third parties. 4-4.