SCXI OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE

Similar documents
SCXI -1313A Terminal Block

TBX-1316 High-Voltage Attenuator Terminal Block

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

SCC-AO10 Isolated Analog Output Module

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

SCC-RLY01 Relay Module

TBX-96 TERMINAL BLOCK

CB-27T, TBX-68T, AND CB-68T ISOTHERMAL TERMINAL BLOCKS INSTALLATION GUIDE

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

You need the following to set up and use your terminal block:

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

Where to Start with NI ELVIS

Where to Start with NI ELVIS

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

NI PXI-1042 Series Power Supply Shuttle

The following conventions appear in this document:

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

Electrical. SPECIFICATIONS SH Cable

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

Electromagnetic Compatibility Guidelines

USB-2001-TC. USB-based Thermocouple Input. User's Guide

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

NI PXI-2567 Specifications

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

SCXI -1102/B/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

Low-Cost Multifunction DAQ for USB

GETTING STARTED GUIDE NI S/s/channel, 4-Channel C Series Universal Analog Input Module

SCXI -1104/C. Contents CALIBRATION PROCEDURE. For NI-DAQmx

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4339 and TB-4339/B/C 8 Ch, 24-bit, 25.6 ks/s Universal Bridge Input Module

FP-2000/2010 FieldPoint Quick Start Guide

SCXI SHIELDED MULTI-CHASSIS CABLE ADAPTER

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4322 and TB Channel, Isolated Voltage/Current Analog Output Module

General Specifications. P2-08THM Analog Input

SCC Quick Start Guide

USER GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4340 and TB Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

Ethernet/Serial Interfaces for Compact FieldPoint

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

NI 6703/6704 Calibration Procedure for NI-DAQ mx

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

NI 9213 Calibration Procedure

FP-AO-210 AND CFP-AO-210

NI PXIe-1062Q Power Supply Shuttle

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

NI PXI Contents CALIBRATION PROCEDURE

FP-AO-200 AND CFP-AO-200

1-Wire 4 x 128 Matrix Terminal Block for the NI PXI/PXIe-2532B

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

ESERIES CALIBRATION FIXTURE INSTALLATION GUIDE

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

High-Precision Data Acquisition

NI SMB-2145/2146/2147/2148

Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

VME-GPIB Installation and User Guide

24-Channel, ±24 V Precision PXI Source Measure Unit

Low-Cost Digital I/O Device for USB

FP-AIO-600 and cfp-aio-600

12-Channel, ±24 V Precision PXI Source Measure Unit

Electromagnetic Compatibility Guidelines

FP-PS-4. Features. Installation

8 AI (12-Bit, 10 ks/s), 2 AO (150 Hz), 12 DIO USB Multifunction I/O Device

NI crio-9101/9102/9103/9104

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

Model 7700 Multiplexer Module

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

SX90 Process Controller

For NI PXI and NI SCXI Switch Modules

NI 6521 Specifications

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

Safety and Radio-Frequency Interference

SCXITM. SCXI-1125 User Manual. SCXI-1125 User Manual. October C-01

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

SCXITM. SCXI Chassis User Manual. SCXI Chassis User Manual. April L-01

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

LabVIEW Real-Time Module for Mac OS X User Manual Addendum

NI 9375 DATASHEET. 16 DI/16 DO, 30 VDC, 7 μs Sinking DI, 500 μs Sourcing DO

Line Impedance Stabilization Network (LISN)

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

INSTALLATION INSTRUCTIONS LFH160 Cable

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Perle MCR200 Installation Guide

VXI-SC-1000 CARRIER MODULE

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Transcription:

SCXI -1321 OFFSET-NULL AND SHUNT-CALIBRATION HIGH-VOLTAGE TERMINAL BLOCK INSTALLATION GUIDE Conventions This guide describes how to install and use the SCXI-1321 offset-null and shunt-calibration terminal block with the SCXI-1121 module. You can only use the SCXI-1321 terminal block with SCXI-1121 revision C or later modules. In addition to the 18 screw terminals, the SCXI-1321 has circuitry for offset-null adjustment of Wheatstone bridges, and a socketed shunt resistor for strain-gauge shunt calibration. This terminal block was primarily designed for Wheatstone bridge transducers such as strain gauges, although it can easily accommodate thermocouples, RTDs, thermistors, millivolt sources, volt sources, and current-loop receivers. Thermocouples have cold-junction compensation (CJC) support. The following conventions are used in this guide:» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on the product, refer to the Read Me First: Safety and Radio-Frequency Interference document, shipped with the product, for precautions to take. bold Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. Bold text also denotes parameter names. LabVIEW, National Instruments, NI, ni.com, NI-DAQ, and SCXI are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. January 2003 321924C-01 ni.com 1998 2003 National Instruments Corp. All rights reserved.

italic monospace monospace italic Italic text denotes variables, emphasis, a cross reference, or an introduction to a key concept. This font also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames and extensions, and code excerpts. Italic text in this font denotes text that is a placeholder for a word or value that you must supply. What You Need to Get Started To set up and use the SCXI-1321, you need the following items: SCXI-1321 offset-null and shunt-calibration terminal block SCXI-1321 Offset-Null and Shunt-Calibration High-Voltage Terminal Block Installation Guide Installation Guide Read Me First: Safety and Radio-Frequency Interference SCXI chassis and documentation SCXI-1121 module (revision C or later) and documentation Numbers 1 and 2 Phillips screwdrivers 1/8 in. flathead screwdriver Long-nose pliers Wire cutter Wire insulation stripper SCXI-1321 Terminal Block Installation Guide 2 ni.com

Connecting the Signals Note Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers, or connecting or disconnecting any signal wires. To connect the signal to the terminal block, complete the following steps, referring to Figure 1 as necessary: 1. Unscrew the top-cover screws and remove the cover. 2. Loosen the strain-relief screws and remove the strain-relief bar. 3. Enable or bypass each of the nulling circuits, depending on the signal you are measuring. Note Disable the offset-nulling circuitry when you are not using a Wheatstone bridge or when the excitation channel of the SCXI-1121 is in current mode. 4. Run the signal wires through the strain-relief opening. You can add insulation or padding if necessary. 5. Prepare the signal wire by stripping the insulation no more than 7 mm (0.28 in.). 6. Connect the wires to the screw terminals by inserting the stripped end of the wire fully into the terminal. No bare wire should extend past the screw terminal. Exposed wire increases the risk of a short circuit and a hardware failure. 7. Tighten the screws to a torque of 0.57 to 0.79 newton-m (5 to 7 lb-in.). 8. Connect safety earth ground to the safety-ground lug. Refer to the Read Me First: Safety and Radio-Frequency Interference document for connection information. 9. Reinstall the strain-relief bar, and tighten the strain-relief screws. 10. Reinstall the top cover, and tighten the top-cover screws. 11. Connect the terminal block to the module front connector as explained in the Installing the Terminal Block section. National Instruments Corporation 3 SCXI-1321 Terminal Block Installation Guide

2 6 7 3 1 4 5 Back View Front View 1 Strain-Relief Bar 2 Strain-Relief Screws 3 Safety-Ground Lug 4 Mating Connector 5 Thumbscrew 6 Top-Cover Screws 7 Top Cover Figure 1. SCXI-1321 Parts Locator Diagram SCXI-1321 Terminal Block Installation Guide 4 ni.com

5 6 7 8 9 10 11 12 3 4 2 13 14 15 16 1 20 19 18 17 1 Screw Terminals 2 Product Information 3 W1 (CH0 Null Enabled) 4 W2 (CH1 Null Enabled) 5 R3 (CH0 Null Resistor) 6 R4 (CH0 Shunt Resistor) 7 R5 (CH1 Null Resistor) Note: R3 through R10 are socketed. 8 R6 (CH1 Shunt Resistor) 9 R7 (CH2 Null Resistor) 10 R8 (CH2 Shunt Resistor) 11 R9 (CH3 Null Resistor) 12 R10 (CH3 Shunt Resistor) 13 W5 (CJC Mode) 14 Warning Label 15 W4 CH3 Null Enabled) 16 W3 (CH2 Null Enabled) 17 R15 (CH3 Null Potentiometer) 18 R14 (CH2 Null Potentiometer) 19 R2 (CH1 Null Potentiometer) 20 R1 (CH0 Null Potentiometer) Installing the Terminal Block Figure 2. SCXI-1321 Circuit Parts Locator Diagram To connect the terminal block to the SCXI module front connector, complete the following steps: 1. Connect the module front connector to its connector on the terminal block. 2. Make sure that the module top and bottom thumbscrews do not obstruct the rear panel of the terminal block. 3. Tighten the top and bottom screws on the back of the terminal block to hold it securely in place. 4. Refer to the Performed or Supported Signal Conditioning section for information on specific signal conditioning. National Instruments Corporation 5 SCXI-1321 Terminal Block Installation Guide

Note To minimize the temperature gradient inside the terminal block, move the SCXI chassis away from any extreme temperature differential. Specifications All specifications are typical at 25 C unless otherwise specified. Electrical Cold-junction sensor Accuracy 1...0.9 C Output...10 mv/ C from 0 to 55 C Resistors R SHUNT...301 kω ±1% R NULL...39 kω ±5% R TRIM...10 kω Nulling potentiometer Range...0 to 10 kω Step size...infinite (user adjustable) Mechanical Resistor sockets Connecting lead size...0.023 to 0.026 in. Connecting lead length...0.110 to 0.175 in. Lead spacing...0.500 in. Maximum Working Voltage Maximum working voltage refers to the signal voltage plus the common-mode voltage. Channel-to-earth...300 V, Installation Category II Channel-to-channel...300 V, Installation Category II 1 The temperature sensor accuracy includes tolerances in all component values caused by temperature and loading, and self-heating. SCXI-1321 Terminal Block Installation Guide 6 ni.com

Environmental Operating temperature... 0 to 50 C Storage temperature... 20 to 70 C Humidity... 10 to 90% RH, noncondensing Maximum altitude... 2,000 meters Pollution Degree (indoor use only)... 2 Safety The SCXI-1321 is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control and laboratory use: IEC 61010-1, EN 61010-1 UL 3111-1, UL61010B-1 CAN/CSA C22.2 No. 1010.1 Note For UL and other safety certifications refer to the product label or to ni.com. Electromagnetic Compatibility Emissions... EN 55011 Class A at 10 meters; FCC Part 15A above 1 GHz Immunity... EN 61326:1997 + A2:2001, Table 1 EMC/EMI... CE, C-Tick and FCC Part 15 (Class A) Compliant Note For EMC compliance, operate this device with shielded cabling. CE Compliance The SCXI-1321 meets the essential requirements of applicable European Directives, as amended for CE Marking, as follows: Low-Voltage Directive (safety)... 73/23/EEC Electromagnetic Compatibility Directive (EMC)89/336/EEC National Instruments Corporation 7 SCXI-1321 Terminal Block Installation Guide

Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, click Declarations of Conformity Information at ni.com/hardref.nsf/. Performed or Supported Signal Conditioning This section provides information on types of signal conditioning performed by the SCXI-1321 or is supported by it. Offset Nulling Offset nulling is a hardware nulling procedure used with Wheatstone-bridge transducers that have an initial offset error. Correcting this error improves measurement accuracy. The nulling circuitry operates with quarter-bridge, half-bridge, and full-bridge strain-gauge configurations. Each channel has its own nulling circuitry and its own trimming potentiometer as listed in Table 1. Table 1. Trimmer Potentiometers and Corresponding Channels Channel Number To null the static offset voltage of the bridge, complete the following steps: 1. Connect the bridge configuration to the selected channel. 2. Select and read the channel output. Trimmer Potentiometer 0 R1 1 R2 2 R14 3 R15 3. While monitoring the output, rotate the trimmer wiper with a flathead screwdriver until you reach 0 V. You have nulled the bridge and are ready for a measurement. The nulling range that is provided with the terminal block is ±2.5 mv, assuming that you have a 120 Ω strain gauge quarter-bridge configuration and 3.3 V excitation voltage. You can change this range by replacing the nulling resistor with a resistor of another value. Each channel has an independent socketed nulling resistor. Therefore, you can mix the ranges to accommodate each channel requirement. Table 2 lists the nulling resistors and their corresponding channels. SCXI-1321 Terminal Block Installation Guide 8 ni.com

The factory default value of all the nulling resistors on the terminal block is 39 kω. Note These resistors are socketed for easy replacement. These sockets best fit a 1/4 W resistor lead size. To determine the nulling range, use the following formula while referring to Figures 3 through 5: where V exc is the excitation voltage (3.3 V or 10 V) R d is either a completion resistor or a second strain-gauge nominal resistance R null is the nulling resistor value (range of trim potentiometer + nulling resistor) R g is the nominal strain-gauge resistance value For example, V nulling range = ±2.56 mv V exc = 3.3 V R d = 120 Ω R null = 39 kω R g = 120 Ω Table 2. Nulling Resistors and Corresponding Channels Channel Number V nulling range Nulling Resistor 0 R3 1 R5 2 R7 3 R9 = ± V --------- exc 2 V exc R d ( R null + R g ) ---------------------------------------------------------- R null R g + R d ( R null + R g ) National Instruments Corporation 9 SCXI-1321 Terminal Block Installation Guide

Assuming a strain-gauge range with a gauge factor of GF = 2 and a quarter-bridge configuration, this range corresponds to ±1,498 µε, as given by the strain formula for a quarter-bridge strain-gauge configuration: ε = 4V ------------------------------- r GF( 1 + 2V r ) where strained voltage static unstrained voltage V r = ------------------------------------------------------------------------------------------------------- V exc SCXI-1121 SCXI-1321 Transducer + R SCAL 301 kω CH CH R 4 (gauge) V EX + R 1 R 2 4.5 kω 4.5 kω EX R Trim 10 kω R Null 39.1 kω EX R 3 (dummy) R Trim (Screw Adjusts Potentiometer) Note: R 1 and R 2 are completion resistors. Figure 3. Quarter-Bridge Nulling Circuit SCXI-1321 Terminal Block Installation Guide 10 ni.com

SCXI-1121 SCXI-1321 Transducer + R SCAL 301 kω CH CH R 4 (gauge) V EX + R 1 R 2 4.5 kω 4.5 kω EX R Trim 10 kω R Null 39.1 kω EX R 3 (gauge) EX R Trim (Screw Adjusts Potentiometer) Note: R 1 and R 2 are completion resistors. Figure 4. Half-Bridge Nulling Circuit National Instruments Corporation 11 SCXI-1321 Terminal Block Installation Guide

SCXI-1121 SCXI-1321 Transducer + CH R SCAL 301 kω CH R 1 (gauge) CH R 4 (gauge) V EX + R Trim 10 kω R Null 39.1 kω R 2 (gauge) R 3 (gauge) EX EX R Trim (Screw Adjusts Potentiometer) Figure 5. Full-Bridge Nulling Circuit Shunt Calibration Shunt calibration provides a method of adjusting for gain error to improve accuracy. The shunt-calibration circuitry configuration places a shunting resistor in parallel with the resistive element connected between and (element R4) of the Wheatstone bridge gauge, as shown in Figure 5. Shunt calibration circuits of each channel are independent from each other, although they are controlled together in software; therefore, when SCAL is engaged on a channel, all the shunt switches of the channels are closed. When SCAL is disengaged, all the switches are open. At startup or reset, all switches are open by default. You can control SCAL with the NI-DAQ function SCXI_Calibrate_Setup. Set the Cal_Op parameter to 2 for engaged or 0 for disengaged. You can use LabVIEW to take measurements from channels with the shunt resistors connected by using the SCXI channel string obx! scy! mdz! shuntw. where x is the onboard channel number (0 for single chassis systems) y is the chassis ID (1 by default) SCXI-1321 Terminal Block Installation Guide 12 ni.com

z is the module slot of the SCXI-1121 w is the channel of the module that you want to engage the shunt and take measurements For example, if you want to measure the voltage at channel 0 with the shunt resistor enabled, use the SCXI channel string ob0! sc1! md1! shunt0. You also can specify a list of channels by using ob0! sc1! md1! shunt0:w, for example. Refer to the LabVIEW Measurements Manual for information on using SCXI channel strings. The shunting resistors R SCAL are socketed so that you can replace them with a resistor of another value to achieve the required nulling range for your application. The sockets and corresponding channels are shown in Table 3. The factory installed R SCAL provided on the terminal block have a 301 kω ±1% value. Channel Table 3. Socket to Channel Relationship Shunt Resistor Socket 0 R4 1 R6 2 R8 3 R10 Assuming a quarter-bridge strain-gauge configuration with a gauge factor of GF = 2, the equivalent strain change introduced by the R SCAL shunting resistor is 199 µε. Refer to the Traditional NI-DAQ User Manual for more information on strain-gauge bridge configurations and formulas. Use the following formula to determine the change due to this shunting resistor: V V ex R d ( R SCAL + R g ) V change = ---------------------------------------------------------------- ------- ex R g R SCAL + R d ( R SCAL + R g ) 2 Next, using the appropriate strain-gauge strain formula, and assuming that you have no static voltage, determine the equivalent strain the R SCAL should provide. For example, R SCAL = 301 kω and a quarter-bridge 120 Ω strain National Instruments Corporation 13 SCXI-1321 Terminal Block Installation Guide

Cold-Junction Compensation gauge with a gauge factor of GF = 2, V exc = 3.3 V, and R = 120 Ω produces the following: V change = 0.3321 mv Replacing the strained voltage by V change in the quarter-bridge strain equation produces an equivalent 199 µε of change. Refer to the NI-DAQ User Manual for more information on voltage to strain conversion equations. CJC is used only with thermocouples and provides improved accuracy of temperature measurements. The CJC temperature sensor, mounted in the SCXI-1321, outputs 10 mv/ C and has an accuracy of ±0.9 C over the 0 to 55 C temperature range. To determine the temperature, use the following formulas: T ( C) = 100 V TEMPOUT T ( C) 9 T ( F) = ------------------------ + 32 5 where V TEMPOUT is the temperature sensor output voltage, and T ( F) and T ( C) are the temperature readings in degrees Fahrenheit and degrees Celsius, respectively. Note Use the average of a large number of samples to obtain the most accurate reading. Noisy environments require averaging for greater accuracy. You cannot use virtual channels to take the readings. You can enable the CJC sensor in one of two ways depending on the input mode configuration of the SCXI-1121. Jumper W5 switches the temperature sensor output between MTEMP (multiplexed mode) and DTEMP (parallel mode) modes. In MTEMP mode, you must scan the cold-junction temperature independently of the other AI channels on the SCXI-1121 using the LabVIEW Getting Started Analog Input VI, available in examples\daq\run_me.llb, with the channel string ob0! sc1! md1! mtemp. This reads the temperature sensor on the terminal block connected to the module in slot 1 of SCXI chassis 1. You then can average several measurements of the cold-junction temperature and use this average to compensate for the cold junction of the thermocouple. Using this averaging method compensates for temperature variations during the measurement period and makes the CJC temperature more accurate. SCXI-1321 Terminal Block Installation Guide 14 ni.com

RTD and Thermistor Excitation You can read a temperature at the beginning of the test and use that value with the data that follows. Using this method assumes that there are no temperature variations during the measurement period. If there are temperature variations, the measurements can be less accurate. You also can read the cold-junction temperature once per scan of the thermocouple channels. Use the DTEMP mode if you are operating the SCXI-1121 in parallel mode. DTEMP uses CH4 analog input, therefore CH3 is not available. By properly setting the excitation, you can configure the SCXI-1321 on a per channel basis for RTD and thermistor measurements. With the SCXI-1121 excitation set in the current mode, you must disable the nulling circuit of the channel of interest. You can do this in two steps: 1. Place the enable/disable jumper in position D (disable) as shown in Table 4. 2. Remove the nulling resistor from its sockets. Table 4. Jumper Settings of the Nulling Circuits Jumper Position Description W1 Nulling circuit of Channel 0 D is enabled (factory default setting) E D Nulling circuit of Channel 0 is disabled E W2 Nulling circuit of Channel 1 D is enabled (factory default setting) E D Nulling circuit of Channel 1 is disabled E National Instruments Corporation 15 SCXI-1321 Terminal Block Installation Guide

Table 4. Jumper Settings of the Nulling Circuits (Continued) Jumper Position Description W3 D Nulling circuit of Channel 2 is enabled (factory default setting) E D Nulling circuit of Channel 2 is disabled E W4 Nulling circuit of Channel 3 D is enabled (factory default setting) E D Nulling circuit of Channel 3 is disabled E *321924C-01* 321924C-01 Jan03