Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE
TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD... 3 B. CABLING TO THE TELEPHONE INTER FACE BOARD... 4 C. CABLING BETWEEN UNITS WITH DUAL SHORT HAUL MODEMS... 4 D. CABLING BETWEEN UNITS WITHOUT DUAL SHORT-HAUL MODEMS... 4 E. CABLING FOR ADDITIONAL FEATURES...4 F. CABLING FOR FACTORY-SUPPLIED VIDEO CAMERA OPTION... 5 3. DIMENSIONAL DRAWINGS OF INFINITY...6 A. INFINITY L SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV)... 6 B. INFINITY L FLUSH MOUNT SYSTEM... 7 C. INFINITY M SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV)... 8 D. INFINITY M WITH CAMERA FLUSH MOUNT SYSTEM... 9 E. INFINITY S SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV)... 10 F. INFINITY S FLUSH MOUNT SYSTEM... 11 G. INFINITY DI SURFACE MOUNT SYSTEM... 12 H. INFINITY DI FLUSH MOUNT SYSTEM... 13 I. INFINITY B SYSTEM... 14 J. CAMERA MOUNTING... 15 4. ILLUSTRATION OF PROCESSOR BOARDS...16 A. MAIN PROCESSOR BOARD (REVISIONS E THROUGH F )... 16 B. 1100329 MODEL TELEPHONE INTERFACE BOARD... 17 C. AUXILIARY RELAY MODULE BOARD... 18 D. 1110076 POWER SUPPLY BOARD... 19 IMPORTANT: The Sentex Systems, Inc. warranty on this system is conditioned upon Sentex Systems, Inc. being paid in full for this equipment. The warranty will not be honored until such payment is received by Sentex Systems, Inc. Copyright 2002 All Rights Reserved This document is protected by copyright and may not be copied or adapted without prior written consent of Sentex Systems, Inc. This document contains the information proprietary to Sentex and such information may not be distributed without the prior written consent of Sentex. The software and firmware included in the Sentex Infinity system as they relate to this documentation are also protected by copyright and contain information proprietary to Sentex. Sentex Systems Chatsworth, CA Visit us at www.sentexsystems.com The purpose of this guide is to assist you in meeting any specification requirements you may encounter in installing an Infinity system. The information enclosed in this manual is to be used for reference purposes only and is not intended to be an installation or programming manual. Page 2 of 19 Doc 6001564 Rev B
1. CABINET DIMENSIONS TYPE OF SYSTEM HEIGHT WIDTH DEPTH Infinity L or DI Surface Mount 21.0 16 7/16 4 1/4 Flush Mount Back Box 21 1/4 16 3/4 3 3/16 Flush Mount Bezel 23 11/16 19 3/16 Infinity M Surface Mount 16.0 11 3/4 4 1/4 Flush Mount Back Box 16 7/16 12 1/4 3 1/4 Flush Mount Bezel 18 3/4 14 1/2 Infinity S Surface Mount 16.0 11 3/4 3 1/4 Flush Mount Back Box 16 7/16 12 1/4 2 1/4 Flush Mount Bezel 18 3/4 14 1/2 Infinity B: 23.0 14.0 2 3/4 2. WIRE CHART PLEASE NOTE: If the wires you are pulling for this installation are going to be run through an indoor, weather-proof location, it is acceptable to use unshielded cable. If the wires are going to be run through an outdoor location, we recommend that you use shielded cable. Recommendations for both types of cable are provided where needed. A. CABLING TO THE MAIN PROCESSOR BOARD Cabling to the Main Processor Board Type of Wire Recommendations From the power transformer or power supply 2 conductor cable See chart below: 120 VAC outlet From the door strike or the door strike 2 conductor cable See specifications for power supply the device you are installing. DC POWER WIRE SIZE DISTANCE AC POWER WIRE SIZE 18 AWG 30' and under 14 AWG 16 AWG 30'-75' 12 AWG 12 AWG 75'-150' ----- 10 AWG 150'-250' ----- PLEASE NOTE: If you are using the larger sizes of cable (i.e., 12 awg or 10 awg), you may experience problems inserting the wires into the terminal block. If you encounter this problem, you can connect a 16-18 awg wire (with the use of a wire nut) to each end of the power cable, as long as the smaller gage wire is under 12 inches in length. Rev B Doc 6001564 Page 3 of 19
B. CABLING TO THE TELEPHONE INTER FACE BOARD Cabling to the Telephone Interface Board Type of Wire Recommendations From the telephone company jack 2 conductor, Shielded-Belden #9501 18 to 22 awg cable Unshielded-Belden #8740 C. CABLING BETWEEN UNITS WITH DUAL SHORT HAUL MODEMS (Multi-Link Systems only) Type of Wire Recommendations From LINE 2 on the first unit and 2 conductor, 16 to 24 awg Shielded-Belden #9501 LINE 1 on the second unit (5000 ft. max.) twisted pair cable Unshielded-Belden #8740 D. CABLING BETWEEN UNITS WITHOUT DUAL SHORT-HAUL MODEMS (Multi-Link Systems only) Type of Wire Recommendations From TB3 on the first unit and 5 conductor, Shielded-Belden #9929 TB2 on the second unit (50 ft. max.) 18 to 24 awg cable Unshielded-Belden #8445 E. CABLING FOR ADDITIONAL FEATURES On an Infinity System Type of Wire Recommendations From a computer terminal 3 conductor Use shielded cable only to the Main Processor Board (50 ft. max.) 16 to 24 awg cable Shielded-Belden #9925 From a printer 3 conductor Use shielded cable only to the Main Processor Board (50 ft. max.) 16 to 24 awg cable Shielded-Belden #9925 From a Stand-Alone Modem 3 conductor Use shielded cable only to the Main Processor Board (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9925 From a Remote Keypad 7 conductor Use shielded cable only to the Main Processor Board (500 ft. max.) 20 to 24 awg cable Shielded-Belden #9932 From a Wiegand, Barium Ferrite, Proximity, or Clikcard card reader to the 5 conductor Use shielded cable only Main Processor Board (500 ft. max.) 24 awg cable Shielded-Belden #9929 On a Multi-Link System Type of Wire Recommendations Between a Computer Terminal 3 conductor Use shielded cable only and the first unit of the system (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9925 Between A Computer Terminal 2 conductor, Use unshielded cable only and a Stand-Alone Short Haul Modem (50 ft. max.) 16 to 24 awg, Unshielded-Belden #8740 twisted pair cable Between a Printer and the 3 conductor Use shielded cable only first (or last) unit of the system (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9925 Between a Printer and a 2 conductor, Use unshielded cable only Stand-Alone Short-Haul Modem (50 ft. max.) 16 to 24 awg, Unshielded-Belden #8740 twisted pair cable Between a Printer and 2 conductor Use shielded cable only the AUX port of a terminal (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9501 Page 4 of 19 Doc 6001564 Rev B
On a Multi-Link System (Continued) Type of Wire Recommendations Between an External Telephone Modem 3 conductor Use shielded cable only and the first unit of the system (50 ft. max.) 18 to 24 awg cable Shielded-Belden #9925 Between an External Telephone Modem 2 conductor, Use unshielded cable only and a Stand-Alone Short-Haul Modem (50 ft. max.) 16 to 24 awg, Unshielded-Belden #8740 twisted pair cable Between a Remote Keypad 7 conductor Use shielded cable only and a unit within the system (500 ft. max.) 20 to 24 awg cable Shielded-Belden #9932 Between a Wiegand, Barium Ferrite, Proximity, or Clikcard card reader 5 conductor Use shielded cable only and a unit within the system (500 ft. max.) 24 awg cable Shielded-Belden #9929 F. CABLING FOR FACTORY-SUPPLIED VIDEO CAMERA OPTION Cabling for Factory-Supplied Video Camera Option From the separate power transformer at the 120 VAC outlet Between the video output and a Video Monitor (1000 ft. max max length based on monitor with.25 volt p-p. composite signal sensitivity) Type of Wire Recommendations 2 conductor cable See chart below: Single Conductor 75 Ohm Cable: Belden #9240 or equiv. RG-59/u coaxial cable BNC Connectors: Amphenol #31-71008 or equiv. DC POWER WIRE SIZE DISTANCE AC POWER WIRE SIZE 18 AWG 30' and under 18 AWG 18 AWG 30 75 18 AWG 18 AWG 75 150 14 AWG 16 AWG 150 250 12 AWG 12 AWG 250 500 10 AWG Rev B Doc 6001564 Page 5 of 19
3. DIMENSIONAL DRAWINGS OF INFINITY A. INFINITY L SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV) This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity L system itself. NOTE: Camera is optional. Page 6 of 19 Doc 6001564 Rev B
B. INFINITY L FLUSH MOUNT SYSTEM FLUSH MOUNT BOX This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity L Flush Mount system itself. Rev B Doc 6001564 Page 7 of 19
C. INFINITY M SURFACE MOUNT SYSTEM (SHOWN WITH OPTIONAL CCTV) 11 3/4" 2 X 20 LCD Display Enclosure Lock Speaker Camera Keypad 1 2 3 4 5 6 7 8 9 0 # Postal Lock Microphone 16.0" 3 1/2" 4 1/4" 3/4 1564F1 FRONT VIEW SIDE VIEW This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity M system itself. NOTE: Camera is optional. Page 8 of 19 Doc 6001564 Rev B
D. INFINITY M FLUSH MOUNT SYSTEM 3 1/4" 2 1/4" 3 3/4" 5 1/4" 1.0" 7 1/4" 16 7/16" 7.0" 1.0" 1564F2 12 1/4" FRONT VIEW 7/8" 5 1/8" 5 1/8" 1 1/8" REAR VIEW FLUSH MOUNT BOX This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity M Flush Mount system itself. Rev B Doc 6001564 Page 9 of 19
E. INFINITY S SURFACE MOUNT SYSTEM 11 3/4" Small LCD Display Enclosure Lock Keypad 1 2 3 4 5 6 7 8 9 0 # Microphone 16.0" Speaker Postal Lock 2 1/2" 3/4" 3 1/4" 1114F7 FRONT PANEL SIDE VIEW This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity S system itself. Page 10 of 19 Doc 6001564 Rev B
F. INFINITY S FLUSH MOUNT SYSTEM FLUSH MOUNT BOX This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity S Flush Mount system itself. Rev B Doc 6001564 Page 11 of 19
G. INFINITY DI SURFACE MOUNT SYSTEM This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity DI system itself. Page 12 of 19 Doc 6001564 Rev B
H. INFINITY DI FLUSH MOUNT SYSTEM FLUSH MOUNT BOX This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity DI Flush Mount system itself. Rev B Doc 6001564 Page 13 of 19
I. INFINITY B SYSTEM This line drawing is intended for dimensional reference purposes only and is not intended to be an actual drawing of the Infinity B system itself. Page 14 of 19 Doc 6001564 Rev B
J. CAMERA MOUNTING This drawing is provided for your information only. Side View Rev B Doc 6001564 Page 15 of 19
4. ILLUSTRATION OF PROCESSOR BOARDS A. 1100072 MAIN PROCESSOR BOARD (REVISION H ) KEYPAD LIGHT 12V AC/ 13.5V DC POWER GROUND SCREW CLEAR TO SEND RS232 OUT GROUND RS232 IN REQUEST TO SEND CLEAR TO SEND RS232 OUT GROUND RS232 IN REQUEST TO SEND LED A A READER DATA 1 A READER DATA 0 +5 VDC GROUND +12VDC READER POWER LED B B READER DATA 1 B READER DATA 0 +5 VDC GROUND STATUS LINE 3 COMMON STATUS LINE 4 HEATER A TB1 J19 J18 TB2 TB4 TB6 CTS OUT GND RS232 IN PORT 1 RTS TB3 CTS OUT GND RS232 IN PORT 2 IN HI RTS GRN RED LED A A RDR 1 A RDR 0 +5VDC GND TB5 LED B B RDR 1 B RDR 0 +5VDC GND TB7 +12VDC RDR POWER STATUS 3 COM STATUS 4 RED LO FAN B FAN A J17 J3 SMALL DISPLAY CONNECTOR 300 1200 2400 4800 J16 J1 LARGE DISPLAY CONNECTOR RS232 BAUD SEL MONTIOR CLEAR STATUS LINE 1 COMMON STATUS LINE 2 COMMON NOR. OPEN NOR. CLOSED COMMON NOR. OPEN NOR. CLOSED COMMON NOR. OPEN NOR. CLOSED COMMON NOR. OPEN NOR. CLOSED TB8 STATUS 1 COM STATUS 2 TB9 COM NO NC TB10 COM NO NC TB11 COM NO NC TB12 COM NO NC RELAY 2 RELAY 4 RELAY 1 RELAY 3 HANDHELD PROGRAMMER CONNECTION HAND HELD TERMINAL J14 MAIN KEYPAD A KEYPAD J7 CONTRAST ADJUSTMENT POT J9 TEMP SENSE CONTRAST ADJ REMOTE A KEYPAD 1 2 3 4 5 6 7 TB14 REMOTE B KEYPAD 1 2 3 4 5 6 7 TB15 1114F17 Page 16 of 19 Doc 6001564 Rev B
B. 1100329 MODEL TELEPHONE INTERFACE BOARD Telephone Interface Board (SN1100329) LINE RING OFF HOOK CLICK DETECT CLICK LEVEL VR3 CLICK LEVEL SPEAKER LEVEL VR4 PANEL SPEAKER J1 Daughter Board (SN1110080) HANDSET TB1 LINE BAL 1 LINE BAL 2 MIC SENS PANEL MIC TELCO LINE 1564F3 GROUND Rev B Doc 6001564 Page 17 of 19
C. AUXILIARY RELAY MODULE BOARD Page 18 of 19 Doc 6001564 Rev B
D. 1110076 POWER SUPPLY BOARD WITH BOARD MOUNT CAMERA IMPORTANT NOTE: Do not use the same power supply for this board as for the telephone entry system. The power inputs must be isolated. Rev B Doc 6001564 Page 19 of 19