BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 3 from

Similar documents
POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

PSBOC PSBOC 27,6V/5,5A/OC

Features: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

Features: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras

Features: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space

Features: DS54 v1.0 DIN rail mounted switch 5-port DS54 for 4 IP cameras without power supply

Features: Example of use

PSBEN 3012C. PSBEN 13,8V/3A/17Ah/EN Buffer, switched mode power supply unit.

EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems

v.1.1/iv EN54 27,6V/7A/2x40Ah power supply for fire alarm systems

PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3

PSBEN 10A12E. PSBEN 13,8V/10A/65Ah/EN Buffer, switch mode power supply unit Grade 3.

PSBEN 2012B v.1.1/vii PSBEN 13,8V/2A/7Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

Buffer power supply units. compliant with EN are intended to alarm system devices

v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN/LCD buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3

PSBEN 5012D/LCD. PSBEN 13,8V/5A/40Ah/EN/LCD Buffer, switched mode power supply unit.

PSBEN 2012B/LCD. PSBEN 13,8V/2A/7Ah/EN/LCD Buffer, switched mode power supply unit.

EN54-2A17. EN54 27,6V/2A/2x17Ah power supply for fire alarm systems

Buffered Power Supply PS-30DR v1.0

Installation Manual for D244X Series 24-volt Power Supplies

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

2-Way Wireless I/O Expander Installation Guide

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

2 in 1 LAN Tester and Multimeter Model:

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

Mini Digital Multimeter

Mini Digital Multimeter

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Mini Digital Multimeter Model MN15. User's Guide

RXTH DUAL ROOM SENSOR / SWITCH

Model HM-535 Power Supply Installation and Service Instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

RXTP ROOM TEMPERATURE

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Rhino PSM Power Supplies. Operating Instructions

Operating instructions. Switching amplifier DN0210 DN / / 2015

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Switching Power Supply

CA-A480-A Elevator Controller. Reference & Installation Manual

Mini Digital Multimeter

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

RTU500 series Data Sheet Power Supply CP-E 24/2.5

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

ELV12 Series. Instruction Manual

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

ETHOS Auto Ranging Digital Multimeter

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Operating instructions. Speed monitor D / / 2014

User's Guide. Extech AM A AC Analog Clamp Meter

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

User Guide. Control Box. RoscoLED TM.

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Interface RS485-WiFi

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Operating Instructions Differential Pressure Transducer PS27

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Display Panel BAT 100 LSN. en Operation Guide

DC-D2212R / DC-D2212WR

7032 Digital-Analog Multimeter

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

IGLOO IGLOO EASY INSTRUCTION MANUAL

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

Redundancy unit CP-A RU

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

PRODUCT SPECIFICATION. PC Board Relays. Series.

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Industrial Power Supplies

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

S8VE (60/90/120/180/240-W Models)

Thread length (overall length)

POWER SUPPLY SYSTEM DSO 24V FOR PAVIRO SYSTEM BY BOSCH

American Power Design, Inc.

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Transcription:

BNC08128C v.1.0 BNC 13,8V/8x1A/17Ah Switch mode buffer power supply unit for CCTV. EN** Edition: 3 from 15.05.2014 Supersedes the edition: 2 from 25.03.2014 GREEN POWER CCTV BNC

PSU features: DC 13,8V/8x1A uninterruptible power supply* battery housing for one 17Ah/12V battery wide range of supply voltage: 176 264V AC High efficiency: 83% battery charging and maintenance control deep discharge battery protection UVP battery charging current: 1A/4A, jumper selectable battery output protection against short circuit and reverse connection BNC connectors for connecting the video signal Voltage control at the AUX1 AUX8 outputs FPS technical output indication of the output fuse activation relay and OC type LED optical indication protections: SCP short-circuit protection OVP overvoltage protection Surge protection Antisabotage protection OLP overload protection warranty 2 year from the production date TABLE OF CONTENTS: 1. Technical description. 1.1. General description 1.2. Block diagram 1.3. Description of components and connectors of the PSU 1.4. Technical parameters 2. Installation. 2.1. Requirements 2.2. Installation procedure 3. Power supply operation indication. 3.1. Optical indication 3.2. Technical outputs 4. Service and operation. 4.1. Overload or short-circuit of the power supply output 4.2. Battery operation 4.3. Maintenance 1. Technical description. 1.1. General description. The buffer power supply is intended for uninterrupted supply of CCTV systems requiring stabilized voltage of 12V DC (+/-15%). The PSU supplies voltage of 13,8V DC and total current capacity of: 1. Output current 8x1A + 1A battery charging 2. Output current 8x0,87A + 4A battery charging Total current of the receivers + battery is max. 11A *. The PSU is constructed on the basis of the switch mode PSU. The PSU is characterized by high energy efficiency and is housed in a metal enclosure (color RAL 9003) with battery housing for one 17Ah/12V battery. The power supply unit enables transmitting power and video using a 75 ohm coaxial cable integrated with two power wires (YAP type). Additionally, it is equipped with BNC sockets for connecting the video signal. The power supply outputs are independently protected by melting fuses or PTC polymer fuses. Failure (short circuit) in the output circuit will activate the melting fuse or PTC fuse and disconnect the circuit from DC power (+ U). Fuse failure is indicated by switching off the corresponding LEDs: L1 for AUX1, etc. In addition, the FPS output (hi-z state) and LFPS LED are activated and the relay contacts change their position. The PSU is housed in a metal enclosure with signaling panel equipped with a microswitch indicating door opening (front cover). * See diagram 1 2

1.2. Block diagram. Figure 1. Block diagram of the PSU. 1.3. The description of components and connectors of the PSU. Table 1. Component No. [Figure 2] [1], [11] [2] Description LED optical indication: green L IN indication of voltage at the IN input red L AC AC voltage indication red L FPS FPS failure indication Connector: IN power supply of the module (factory setting) AC 230V mains supply indication input [3] F1 F8 fuses in the AUX1 AUX8 (+), F1A circuits [4] Jumper to select melting fuse or PTC polymer fuse [5] Green LED L1 L8 voltage indication at the AUX outputs (during normal operation, these LEDs are on) [6] BNC connector of the video output to the DVR [7] BNC connector of the video input from the cameras [8] AUX1 AUX8 camera power supply outputs (12 15V) [9] FPS technical output indicating failure OC type [10] FPS technical output indicating failure relay type [12] Optional, external optical indication connector (factory setting) Table 1. The description of components of the BNC module. 3

Figure 2. Components arrangement. Component No. [Figure 3] Figure 3. The view of the PSU. [1] The module of the switch mode PSU Description [2] LED light indicating correct operation of the switch mode PSU [3] ADJ potentiometer regulation of the power supply output voltage [4] Selection jumper for charging current: Ibat =1 A Ibat =4 A Description: jumper on, jumper off. Factory setting: Ibat =1A (jumper on). [5] BNC module 4

[6] TAMPER microswitch (contacts) of antisabotage protection (NC) [7] Connectors for connecting the batteries: +BAT = red, - BAT = black 1.4. Technical parameters. - electrical parameters (Table 3) - mechanical parameters (Table 4) - safety of use (Table 5) - operation parameters (Table 6) Table 2. Components of the PSU (see Figure 3). Electrical parameters (Table 3). Mains supply 176 264V AC Current consumption 1,4A@230V AC max. PSU s power 152W max. Efficiency 83% Output voltage 11V 13,8V DC buffer operation 9,5V 13,8V DC battery operation The adjustment range of the output voltage 12 14V DC Output current t AMB <30 C 8 x 1A + 1A battery charging see diagram 1 8 x 0,87A + 4A battery charging see diagram 1 Output current t AMB =40 C 8 x 0,83A + 1A battery charging see diagram 1 8 x 0,46A + 4A battery charging see diagram 1 Ripple voltage 120 mv p-p max. Battery charging current 1A/4A max. @ 17Ah (± 5%) Current consumption by the PSU 0,18A Short-circuit protection SCP BNC MODULE 8 x F 1A or 8 x PTC 1,1A (jumper selectable) PSU MODULE 105% 150% of PSU power, electronic current limiting Overload protection OLP 105% 150% of PSU power, electronic current limiting Battery circuit protection SCP and reverse polymer fuse polarity connection Overvoltage protection OVP U>115% 150% of the output voltage - disconnection of the output voltage, automatic return Deep discharge battery protection UVP U<9,5V (± 5%) disconnecting the battery terminal Surge protection 8 x varistor Antisabotage protection: - TAMPER output indicating enclosure opening - microswitch, NC contacts (enclosure closed), 0,5A@50V DC (max.) Optical indication of operation: YES LED lights Technical outputs: - FPS technical output indicating output fuse - OC type, 50mA max. activation Normal operation: L state (0V), failure: H state (hi-z), (automatic return once the normal operation is restored) - relay type: 1A@ 30VDC/50VAC, delay time: approximately 10 seconds F1 F8 fuses F 1A or PTC 1,1A Mechanical parameters (Table 4). Enclosure dimensions 300 x 407 x 126 mm (WxHxD) Mounting See Figure 3 Battery housing: 17Ah/12V (SLA) max. H 250x165x105mm (WxHxD) max W D Net weight 4,65kg / 4,95kg Enclosure DC01 steel plate, 1,0mm, RAL 9003 Closing Cylindrical screw x 2 (at the front) lock assembly possible Terminals Switch mode power supply: Φ0,63-2,5 (AWG 22-10) BNC module : Φ0,5-2,1 (AWG 24-12) Input / output of the video signal: BNC TAMPER output: Φ0,8. Notes The enclosure has a 15mm distance from the mounting surface so the cables can be led. 5

Safety of use (Table 5). Protection class PN-EN 60950-1:2004 I (first) Protection grade PN-EN 60529: 2002 (U) IP20 Insulation electrical strength: - between input (network) circuit and the output circuits of the PSU (I/P-O/P) 3000 V/AC min. - between input circuit and PE protection circuit (I/P-FG) 1500 V/AC min. - between output circuit and PE protection circuit (O/P-FG) 500 V/AC min. Insulation resistance: - between input circuit and output or protection circuit 100 MΩ, 500V/DC Operation parameters (Table 6). Operating temperature Storing temperature Relative humidity Vibrations during operation Surges during operation Direct insolation Vibrations and surges during transport -10ºC...+40ºC (see Figure1) -20ºC...+60ºC 20%...90%, no condensation unacceptable unacceptable unacceptable According to the PN-83/T-42106 standard Diagram 1. Acceptable output current from the PSU depending on ambient temperature. 2. Installation. 2.1. Requirements. The buffer PSU should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative humidity (RH=90% maximum, no condensation) and temperature range from -10 C up to +40 C. The power supply sh ould operate in a vertical position in order to provide free and convectional air flow through ventilating holes of the enclosure. The power supply load balance should be done before installation: 1. Output current 8x1A + 1A battery charging 2. Output current 8x0,87A + 4A battery charging Total current of the receivers + battery is max. 11A *. The power supply is designed for a continuous operation and is not equipped with a power-switch. Therefore, an appropriate overload protection in the power supply circuit should be provided. Moreover, the user should be informed how to disconnect the power supply unit from the mains supply (usually by assigning an appropriate fuse in the fuse box). The electrical system shall be made in accordance with applicable standards and regulations. * See diagram 1 6

2.2. Installation procedure. 1. Before installation, cut off the voltage in the 230V power-supply circuit. 2. Mount the PSU in a selected location and lead the connecting cables. 3. Connect the power cables (230V AC) to L-N terminals of the PSU. Connect the ground wire to the terminal marked with grounding symbol:. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. The power cables should be connected to the appropriate terminals on the connection board through the bushing. The shock protection circuit shall be done with a particular care: the yellow and green wire coat of the power cable should be connected to the terminal marked with the symbol in the PSU enclosure. Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE! It can cause damage to the equipment or an electric shock. 4. Connect the power supply line and video signal to the BNC module (See Figure 4): - connect the supply voltage of the camera to the AUX1 AUX 8 outputs - connect the video signals from the cameras and the DVR to the BNC sockets Figure 4. Connecting the camera and DVR to the BNC module. 5. Use the F1/PTC1 F8/PTC8 jumpers to select the type of short circuit / overload protection of individual circuits. Jumper in the Fx position melting fuse activation, PTCx PTC fuse activation. 6. If needed, the following technical connections can be made: - FPS technical output of the PSU status indicates the voltage loss at any of the outputs (AUX1 AUX8). - TAMPER indicating enclosure opening. 7. Check the power supply output voltage: - output voltage of the unloaded power supply without a battery should amount to U=13,8V DC. 8. Set the battery charging current using the jumper (component 4, Figure 5): 7

Selection jumper for charging current: Ibat =1 A Ibat =4 A Description: jumper on, jumper off. Factory setting: Ibat =1A (jumper on). Figure 5. Selection jumper for charging current. 9. Connect the battery according to the color markings: - battery output (+V): BAT+ cable / red - battery output (0V): BAT- cable/ black 10. Check the optical indication of the PSU status: green LED light on the BNC module. 11. Close the cover after installing and checking the operation of the power supply. 3. Power supply operation indication. 3.1. Optical indication. The PSU has 11 LED lights at the front panel: RED LED: on The PSU supplied with 230V AC voltage off no 230V AC mains supply RED LED: on DC voltage at the output of the switch mode PSU off no DC voltage at the output of the switch mode PSU RED LED: on fuse failure at one of the AUX1 AUX8 outputs off no failure GREEN LED: on DC voltage at the AUX1 AUX8 output off no DC voltage at the AUX1 AUX8 output Additionally, the PSU is fitted with LED lights inside the enclosure see Figure 2 and 3: - L AC red LED (Figure 2, component 1) is permanently illuminated during normal operation (AC power ON). No AC power is indicated by turning off the L AC LED. - L IN green LED (Figure 2, component 1) indicates DC voltage at the BNC module input. During normal operation (DC supply) the LED is permanently illuminated. No DC no DC voltage at the module input is indicated by turning off the L IN LED. - L FPS red LED (Figure 2, component 10) is not illuminated during normal operation (no failure). In case of activation of the short circuit / overload protection at any output, the LED is permanently illuminated. - L1 L8 green LEDs (Figure 2, component 5) indicate voltage at the individual outputs of the module (L1 for AUX 1 etc.). Activation of the short circuit / overload protection of a given circuit is indicated by turning off one of the Lx LEDs. 8

3.2. Technical outputs. The PSU has the following indication outputs: FPS technical output of the PSU status: - OC type output indicating failure (short-circuit, overload). During normal operation, shorted to ground L state (0V). In case of power loss, the FPS technical output is switched into hi-z state (high impedance) at least at one of the AUX outputs. Figure 6. Electrical diagram of the OC output. - relay output. In case of failure, relay contacts are switched automatically. Figure 7. Electrical diagram of the relay output CAUTION! The arrangement of contacts at the figure 7 shows a potential-free status of the relay, which is equivalent to a state with no voltage at any of the AUX1 AUX8 outputs. TAMPER output indicating enclosure opening: - volt free contact input indicating the status of the power supply doors, PSU closed: contacts closed (NC), PSU open: contacts open (NO). 4. Service and operation. 4.1. Overload or short-circuit of the power supply output. The AUX1 AUX8 outputs of the PSU are protected against short-circuit by melting fuse inserts or PTC fuses. In case of melting fuse replacement, use only compatible replacement parts. If the PTC polymer fuses are used, then automatic disconnection of the output voltage, indicated by switching off the green LED, takes place. In such case, disconnect the load from the power supply output for approximately 1 minute. 4.2. Battery operation In case of mains power loss, the unit will instantly switch to battery operation. The power supply is equipped with a discharged battery disconnection system. If the voltage at the battery terminals has dropped below 9.5 V during battery operation, the batteries will be disconnected. 4.3. Maintenance. All maintenance procedures can be performed after disconnecting the power supply from the power network. The PSU does not require any specific maintenance; however, its interior should be cleaned with compressed air if used in dusty conditions. In case of fuse replacement, use only compatible replacement parts. 9

WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. CAUTION! The power supply unit is adapted for cooperation with the sealed lead-acid batteries (SLA). After the operation period they must not be thrown but recycled according to the applicable law. GENERAL WARRANTY CONDITIONS 1. Pulsar K. Bogusz Sp.j. (manufacturer) grants a two-year quality warranty for the equipment, starting from the production date. 2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (selected by the manufacturer) if the malfunction is due to the manufacturer. It includes manufacturing or material defects, provided that such defects have been reported within the warranty period (point.1). 3. The equipment subjected to warranty should be brought to the place of purchase or directly to the main office of the manufacturer. 4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect. 5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, however not later that within 14 days from the delivery to the service centre of the manufacturer. 6. The repair period mentioned in point 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant. 7. All the services are carried out at the service centre of the manufacturer, exclusively. 8. The warranty does not cover the defects of the equipment, resulting from: - reasons beyond the manufacturer's control, - mechanical damage, - improper storage and transport, - use that violates the operation manual or equipment s intended use - fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents, - improper installation and configuration (failure to follow instruction). 9. The warranty is void in case of construction changes and repairs carried out by any unauthorized service center or in case of damage or modifications to warranty stickers and serial numbers. 10. The liability of the manufacturer towards the buyer is limited to the value of the equipment determined according to the wholesale prices suggested by the manufacturer on the day of purchase. 11. The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or inability to operate the equipment especially when resulting from failure to comply with the recommendations and requirements contained in the manual. Pulsar K.Bogusz Sp.j. Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 E-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl 10