NI USB-6211/6218 OEM

Similar documents
M Series USB-6221/6225/6229/6251/6255/6259 OEM Devices

NI USB-622x/625x/628x OEM

USER GUIDE USB-634x/635x/636x OEM X Series USB-6341/6343/6356/6361/6363/6366 OEM Devices

The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

INSTALLATION INSTRUCTIONS LFH160 Cable

NI-Industrial Communications for EtherCAT

Where to Start with NI ELVIS

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

Foundation Fieldbus Hardware and NI-FBUS Software

NI 653x Cable Adapter

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

Foundation Fieldbus Hardware and NI-FBUS Software for Windows 2000/XP

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9870E

SCC-AO10 Isolated Analog Output Module

PXI and PXI Express Chassis Fan Replacement

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

LabVIEW for FTC Release Notes

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

Electromagnetic Compatibility Guidelines

Electrical. SPECIFICATIONS SH Cable

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871E

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

Where to Start with NI ELVIS

Getting Started with the NI 783x R

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

SCC-RLY01 Relay Module

You need the following to set up and use your terminal block:

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

ESERIES CALIBRATION FIXTURE INSTALLATION GUIDE

NI PXI-2567 Specifications

NI ELVIS RIO Control Module

Using Desktop PCs as RT Targets with the LabVIEW Real-Time Module

NI PXI Installing the NI PXI-8104 INSTALLATION GUIDE

NI R Series. Contents. Software CALIBRATION PROCEDURE

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

Caution Electrostatic discharge can damage your controller. To avoid such damage, handle the controller only in a proper ESD-controlled environment.

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9476E. 32-Channel, 24 V Sourcing Digital Output Module

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

SH Cable Specifications

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

Programming for the LabVIEW Real-Time Module Using LabWindows/CVI

NI PXI-1042 Series Power Supply Shuttle

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

NI-DAQ mx for USB Devices

NI PXIe-1062Q Power Supply Shuttle

NI 6521 Specifications

NOTE TO USERS NI 65xx Pinout Labels for the SCB-100 Digital I/O Modules/Devices Using the 100-Pin Shielded Connector Block

Bracket and Mounting Dimensions

TBX-1316 High-Voltage Attenuator Terminal Block

24-Channel, ±24 V Precision PXI Source Measure Unit

USER GUIDE I/O Accessory For the NI PCIe-8237R GigE Vision Interface Device

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

USER MANUAL NI 9755 NI Powertrain Controls CompactRIO NOx Sensor Module Kit

NI TSM-101x. LCD Characteristics NI TSM-1012 NI TSM-1015 SPECIFICATIONS. NI TSM-1012, NI TSM-1015, NI TSM-1017 Touch Screen Monitors

12-Channel, ±24 V Precision PXI Source Measure Unit

Contents. Software. CALIBRATION PROCEDURE NI Channel, ±5 V, 24-Bit Software-Selectable IEPE and AC/DC Analog Input Module

NI WSN-9791 Ethernet Gateway

INSTALLATION INSTRUCTIONS Data Management Software Suite in the Evaluation Mode

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

CALIBRATION PROCEDURE CAL Contents. Software

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

IMAQ Vision Deployment Engine Note to Users

IMAQ Vision Deployment Engine Note to Users

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

Introduction... 1 System Diagram... 2 Hardware... 2 Powering the Hardware... 3 Wiring Harness... 5

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

VXI-MXI-Express Series

SCC Quick Start Guide

±10 V, 20 MS/s/ch, 14-Bit, 4-Channel C Series Digitizer Module

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

NI 6581/6581B Specifications

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

NI Contents. Hardware Overview INSTALLATION GUIDE. NI 8221 Features

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

FP-2000/2010 FieldPoint Quick Start Guide

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

SCXI -1313A Terminal Block

Getting Started with R Series Multifunction RIO

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

Getting Results with the NI PXI-6585R

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

NI USB Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, ±10 V, 16-Bit Analog Voltage Output Module

USB Definitions. Conditions. Analog Input SPECIFICATIONS. 8 AI (10 ks/s), 4 DIO USB Multifunction I/O Device

GETTING STARTED GUIDE

NI-DAQ mx Base 1.x. Contents GETTING STARTED GUIDE

NI SMB-2145/2146/2147/2148

Transcription:

USER GUIDE NI USB-6211/6218 OEM This document provides information about the dimensions, mounting options, connectors, and other components of the NI USB-6211/6218 OEM devices. Caution There are no product safety, electromagnetic compatibility (EMC), or CE marking compliance claims made for the USB-6211/6218 OEM devices. Conformity to any and all compliance requirements rests with the end product supplier. Figure 1 shows the USB-6211 OEM and USB-6218 OEM devices. USB-6211 USB-6218 Figure 1. USB-621x OEM Devices Refer to the NI USB-621x Specifications document for USB-6211/6218 specifications and the NI USB-621x User Manual for more information about USB-6211/6218 devices. You can find all documentation at ni.com/manuals.

Dimensions Figure 2 shows the dimensions of the USB-6211 OEM device. 6.250 (158.75) 5.877 (149.28) 0.420 (10.66) Ø 0.130 (3.30) 5.372 (136.45) 2.582 (65.58) 3X Ø 0.142 (3.61) 0.489 (12.42) 1.484 (37.68) 1.958 (49.72) 3.101 (78.77) 0.420 (10.66) 0.516 (13.11) 0.433 (11.00) 0.063 (1.60) 0.091 (2.31) Ø 0.144 (Drill Size 27) Recommended Front Panel Hole Cutout for LED Figure 2. USB-6211 OEM Dimensions in Inches (Millimeters) NI USB-6211/6218 OEM User Guide 2 ni.com

Figure 3 shows the dimensions of the USB-6218 OEM device. 6.250 (158.75) 5.877 (149.28) 0.420 (10.66) Ø 0.130 (3.30) 5.372 (136.45) 2.582 (65.58) 3X Ø 0.142 (3.61) 0.489 (12.42) 0.340 (8.64) 0.420 (10.66) 1.484 (37.68) 1.958 (49.72) 3.101 (78.77) 0.433 (11.00) 0.063 (1.60) 0.516 (13.11) 0.091 (2.31) Ø 0.144 (Drill Size 27) Recommended Front Panel Hole Cutout for LED Figure 3. USB-6218 OEM Dimensions in Inches (Millimeters) National Instruments Corporation 3 NI USB-6211/6218 OEM User Guide

I/O Connector Pinouts Figure 4 shows the connector pinout on the USB-6211 OEM device. PFI 0 PFI 1 PFI 2 PFI 3 PFI 4 PFI 5 PFI 6 PFI 7 AI SENSE AI 0 AI 9 AI 2 AI 11 AI 4 AI 13 AI 6 AI 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 AO 0 AO 1 AI 8 AI 1 AI 10 AI 3 AI 12 AI 5 AI 14 AI 7 = No Connect Figure 4. USB-6211 OEM Connector Pinout NI USB-6211/6218 OEM User Guide 4 ni.com

Figure 5 shows the connector pinouts on the USB-6218 OEM device. PFI 0 PFI 1 PFI 2 PFI 3 PFI 4 PFI 5 PFI 6 PFI 7 AI SENSE AI 0 AI 9 AI 2 AI 11 AI 4 AI 13 AI 6 AI 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 = No Connect AO 0 AO 1 AI 8 AI 1 AI 10 AI 3 AI 12 AI 5 AI 14 AI 7 PFI 8 PFI 9 PFI 10 PFI 11 PFI 12 PFI 13 PFI 14 PFI 15 AI SENSE 2 AI 16 AI 25 AI 18 AI 27 AI 20 AI 29 AI 22 AI 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 = No Connect AI 24 AI 17 AI 26 AI 19 AI 28 AI 21 AI 30 AI 23 Figure 5. USB-6218 OEM Connector Pinout Note In non-referenced single-ended (NRSE) mode, the USB-6218 OEM device measures AI <0..15> relative to the AI SENSE input, and AI <16..35> relative to AI SENSE 2. Refer to the NI USB-621x User Manual at ni.com/manuals for more information about USB-6211/6218 signals and how to connect them. National Instruments Corporation 5 NI USB-6211/6218 OEM User Guide

Board Mounting the USB-621x OEM The USB-621x OEM device can be mounted on a motherboard using the 50-pin connector(s) and board mount socket(s), as shown in Figures 6 and 7. Note You can use either one or both 50-pin connectors to board mount the USB-6218 OEM device. 5 3 4 1 2 1 Mounting Standoff 2 Board Mount Socket 3 50-Pin Connector 4 USB-6218 OEM Device 5 Mounting Screws Figure 6. USB-621x OEM Mounting Using 50-Pin Connectors (USB-6218 OEM Device Shown) Figure 7. USB-621x OEM Device Installed on Motherboard (USB-6218 OEM Device Shown) Refer to the Device Components section for more information about mounting components. NI USB-6211/6218 OEM User Guide 6 ni.com

Device Components Component Table 1 contains information about the components used for interfacing and interacting with the USB-621x OEM device. Table 1. USB-621x OEM Components Reference Designator(s) on PCB Manufacturer Manufacturer Part Number 50-pin connector J6 *, J7 3M N2550-6002UB USB connector J5 AMP 787780-1 50-pin board mount socket 3M 8550-4500PL (or equivalent) Mounting standoff, using board mount socket Mounting standoff, using ribbon cable RAF Electronic Hardware RAF Electronic Hardware * J6 is available on USB-6218 OEM devices only. You can use either one or both 50-pin connectors to board mount the USB-6218 OEM device. 3/16 in. HEX female-to-female, 14 mm long. ** 3/16 in. HEX female-to-female, 1/4 in. long. M1261-3005-SS with M3 0.5 screw 2053-440-SS ** with 4-40 screw National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents. 2006 2007 National Instruments Corporation. All rights reserved. 372083B-01 Jan07