Configuring a Net2 Entry Panel

Similar documents
Configuring a Net2 Entry Panel

Configuring a Net2 Touch Entry Panel

Configuring a Net2 Entry Monitor


Intelligent Security & Fire Ltd

Configuring a Net2 Entry Audio Monitor

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

Packaging Contents. The following components are included in your W52P/W52H IP DECT phone packages

1. Product Specification

PROXIMITY Encoding System

Owner s Manual. 1833, 1834, 1835, 1837 PC Programmable Telephone Entry and Access Control Systems

Installation Manual & User Instructions. MultiCom 100 / 500

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

Classe 300. a STYLISH choice

Installation Manual & User Instructions

CMDR_Commander Key Phone W52P User Guide_GD_42095

Yealink BASIC PHONE GUIDE T48G POWERED BY XCHANGE TELECOM

Installation Manual & User Instructions. MultiCom 500

Wireless Digital Video Doorbell CL-3684 USER S MANUAL

Phone Information. IP2061 Quick Reference Guide. ICON Voice Networks REV 1.0. ICON Voice Networks

Net2 Entry. Overview. A door entry system for versatile security and building management

Quick Start Guide. Intermedia Hosted PBX Yealink W52 Wireless DECT Phone

Setup & Information Guide Zultys 37G VoIP Phones

GIGABIT COLOR IP PHONE

DASH 4.5 user manual 1

Grandstream Networks, Inc. Connecting GDS3710 with GXV3370 Configuration Guide

DG-800 Stand-Alone Proximity Reader Instruction Manual

Dolby Conference Phone. User's guide for BT MeetMe with Dolby Voice

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

Net2 Entry. An installer guide. A door entry system for versatile security and building management

Grandstream Networks, Inc. Connecting GDS3710 with WP820 Configuration Guide

Dolby Conference Phone 3.0 user's guide for BT MeetMe with Dolby Voice

*GA e9e* MODEL : AP-824 /AP-924

Stainless steel Keys Direct-button 1 Numeric Keypad. Optional Microphone 1 Amplifier 1.5W. Adjustable FDSP. RTP CODEC G.711, G.

Alpha-Numeric Display Pager. MODEL: AL-924e

2 IDS LCD Keypad User Manual C Issued March 2009

Wireless Digital Video Doorbell

TPGBizPhone. Standard T42G IP Phone User Guide

SOFTWARE VERSION 3.20

Polycom SoundPoint IP 450

Model MUGAPLM Multi-Unit Gate Access Panel. MUGAPLM Installation & Assembly

smartentry Wireless Video Doorphone User Manual

Cisco IP Phone User Guide

Log into a Lync TM Phone While Hoteling Polycom CX600 IP Phone

2000 Series e/em Style Keypad Installation and Programming Manual

DT243-D4 4.3" COLOR TFT MONITOR USER MANUAL. Please read this manual carefully before using the product you purchase,and keep it well for future use.

Bartley Ridge SECURITY SYSTEMS. User s Guide

TPGBizPhone. Cordless W56P IP DECT Phone User Guide

What s So Great About RF Technology?

User Manual RINS1209-5

EL Models. Keypad Programming Manual For. Telephone Entry/Access Control System. Models EL25, EL2000, and EL2000SS. call toll free at

Nortel IP Phone 1120E/1140E User Guide (CICM).

BT One Phone. Yealink SIP-T40 phone user guide

IDS X-Series User Manual E Issued June 2013

K44 Code lock. Technical manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Documentation on all Paxton products can be found on our web site -

Digital 2.4GHz 3.5 LCD Monitor

TPGBizPhone. CPE860 IP Conference Phone User Guide

Control Panels D9412GV4/D7412GV4. en Owner's Manual

TPG BizPhone. Premium T48G IP Phone User Guide


EN TECHNICAL MANUAL. ViP Mini hands-free monitor art. 6721W. Passion.Technology.Design.

USER S GUIDE. USA Mobility. Odyssey. Numeric Pager

ADVANCED USER S GUIDE

Polycom SoundPoint IP 320/330

Icon Instructions... 6 LED Instructions

NEO 4.5. User Manual

Nortel IP Phone 1120E User Guide

NUOVO TOUCH INTERCOM SYSTEM

Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512. en Owner's Manual

TSW-560/TSW-760/TSW ", 7", and 10.1" Touch Screens. Supplemental Guide Crestron Electronics, Inc.

Wireless Digital Video Doorbell ADB3219 USER S MANUAL

Installation & Operations Manual 2100 Series VOIP Phone

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Typical Wiring Diagram and programming for the FS1000 series 2-wire QwikBUS apt. intercom stations to a single entrance pushbutton door station.

Aastra 480i VoIP Telephone User s Guide

Icon Instructions LED Instructions Touch Screen Display Navigating Menus and Fields Entering Data and Editing Fields

D9412/D7412 Control/Communicator User s Guide Supplement

AE-2. Telephone Entry Control Console. Facility Manager s Programming Guide

Phone Quick Reference Guide. Rev2. M I T E L. EMEA CALA. Global Headquarters U.S. Asia Pacific

Aastra 673xi / 675xi. Telephony with SIP Phones at the Aastra 800/OpenCom 100 Communications System User Guide

Dash 4.0. User Manual

Configuration and Application of Phone and Door Control

LIFE PURE User Manual

Quick Guide MxSoftPanel. MxSoftPanel. This quick guide covers the initial operation and introduces the most important features.

Keypad LCD (software version 3.10) CA-10 plus

I1000M Operation Manual

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation


Integriti User Manual. Elite / EliteX LCD Terminal Keypads

SVT-WIFI Video Intercom System C

Cisco Small Business Model SPA 303g

B T H A L O U S E R G U I D E

AS Keypad User Manual

Commander Phone Essentials Cordless W52P

Algo 8028 SIP Doorphone Manual. Empowered by Innovation P/N ALGO

2-Wire Video Monitor 27

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

ADVANCED USER S GUIDE

Transcription:

Configuring a Entry Panel Overview The Entry Standard panel is a robust external panel for use with Paxton s door entry system and is used to remotely communicate with visitors. It is powered using power over Ethernet (PoE) and communicates with the other elements of the system using IPv6, providing 'plug and play' installation. If used in conjunction with access control software, this must be version 4.25 or later. Use the up and down arrows on the panel to view all the menu options. Use the key to Cancel Initialising a new system The first time the system is powered up the panel will request that the Language to be used is confirmed. It then asks for an Engineer code to be set up. Enter the required code and press the bell key. Confirm the code and press bell to complete the process. The Entry system uses a separate control unit to operate the door. To associate a panel with its control unit, the Serial Number of the control unit must be entered. Calling a monitor unit As Monitor units are added to the system, they will automatically become active. To call a monitor type in the monitor ID and press the Bell button. 1

Single occupancy When only one monitor ID is in use, pressing the Bell button will call the monitor. How an occupant gains entry For access control, a system is required for administration. Once set up, a user can gain entry by presenting their token to the panel. For PIN or Code entry, the # key must be pressed first before pressing the numbers on the panel. Using the engineer menu To access the Engineer menu from the default screen press * twice, enter the Engineer code and press the Bell button. Door open time From the Engineer menu - Press key 1 This is the time period that the lock will stay released once the open door button has been pressed on a monitor. This value may only be changed when not administered by. Volume settings From the Engineer menu - Press key 2 1. Set volume volume - from volume settings menu - Press key 1 This sets the volume of the entry panel speaker. Use the up and down arrow buttons to adjust then press Bell.

2. Set ring volume - from volume settings menu - Press key 2 This sets the volume of the ring tone when making a call. Use the up and down arrow buttons to adjust then press Bell. 3. Set keypress tone - from volume settings menu - Press key 3 This sets the tone that the entry panel will make when a key is pressed Press 1. Click Press 2. Beep Press 3. Silent 4. Set door open tone - from volume settings menu - Press key 4 This sets the tone that the entry panel will make while the lock is released Press 1. Beep Press 2. Buzz Press 3. Silent Call timeout From the Engineer menu - Press key 3 This is the maximum time period that one call can last. This ensures that the entry panel is not held busy if a call is not terminated correctly. View options From the Engineer menu - Press key 4 1. Allow video without being called - from View options menu - Press key 1 This allows the camera to be viewed at any time even when not being used to grant access. 2. Allow audio without being called- from View options menu - Press key 2 This allows the microphone to be turned on at any time even when not being used to grant access. 3. Open the door without being called - from View options menu - Press key 3 This allows the Unlock door button to be used while viewing with the camera. The visitor does not need to initiate the call

Panel settings From the Engineer menu - Press key 5 1. Set control unit - from Panel settings menu - Press key 1 This sets the control unti that that the Entry panel is associated with. Enter the serial number of the control unit and then press bell. 2. Factory reset - from Panel settings menu - Press key 2 This returns the entry panel to factory settings. 3. LCD Backlight - from Panel settings menu - Press key 3 This sets when the entry panel LCD backlight will be on. Press 1. Always on Press 2. Never on Press 3. Only on in low light 4. Video quality - from Panel settings menu - Press key 4 This option slows the video rate to reduce the load on busy networks. Press 1. Low - busy networks Press 2. Med - small networks Press 3. High - private wiring 5. Video Lighting - from Panel settings menu - Press key 5 This allows you to adjust the video lighting for low light conditions. Press 1. On Press 2. Off Press 3. Auto 6. Set Reader - from Panel settings menu - Press key 6 This allows you to set which reader port on the controller is used by the panel. Press 1. Reader 1 Press 2. Reader 2 7. Demo mode - from Panel settings menu - Press key 7 This allows you to put the panel into demonstration mode so it no longer needs to be connected to a controller.

Operating mode From the Engineer menu - Press key 6 1. Number only - from set operating mode menu - Press key 1 This requires the visitior to enter the number without the assistance of a list 2. Numbered list - from set operating mode menu - Press key 2 This displays the monitor IDs to the visitor as a numeric list with its name which they can scroll or enter the number The menu will also respond to numeric input 3. Text selection - from set operating mode menu - Press key 3 This displays the monitor names to the visitor in alphabetical order which they can scroll through and select. Engineer access From the Engineer menu - Press key 7 1. Set engineer code - from Engineer access menu - Press key 1 This allows the engineer to change the engineer code. 2. Change engineer token- from Engineer access menu - Press key 2 This allows the engineer to add/change the engineer token. This engineer can create a token that can be presented to the proximity reader instead of using the engineer code to gain access to the engineer menu. Language From the Engineer menu - Press key 8 This displays the language options available for the monitor About From the Engineer menu - Press key 9 This displays information about the panel (e.g. the current version number)