UEP10M005 Power Supply User s Manual

Similar documents
Fan Tray Unit UEL03M User Manual

NIM / CAMAC User s Manual

CAMAC CERN CE 600W. Main Features. Request Quote

NIM CERN CE 600W. Main Features. Request Quote

VME Mini Crate slot VME Mini Crate slot. Operation Instructions *00682.A0

Modular Floating Power Supply System. PL 500 / PL 6021, F8 RATON-Version <3,1krad. User Manual

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

6U VME Request Quote

VME Mini Crate 195 Operation Instructions

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

W-Ie Ne-R VPX3C Power Supply

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

Energy 3000 Primary Switched Power Supply 3000W VE3PUID ,5/L programmable V/I

UEL 6020 fan tray equipped with 3 individually controlled long-life DC fans, MTBF >60,000h/40ºC

W-Ie Ne-R VPX340DM_A

Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER

WIENER, Plein & Baus, Ltd. LCLS Service Training. WIENER Training- LCLS 10/06 - Tim Hoagland 1

First of all, thank you for purchasing R2W series redundant power supply.

HERCULES-5000 INSTRUCTION MANUAL

INSTALLATION MANUAL SLI 50 INVERTER

Series Watt DC Power Supplies

Modular Floating Power Supply System PL 500 F6, F8. User s Manual. Floating 3U and 6 U Size

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

M1000 INTELLIGENT ZONE CONTROL SYSTEM

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

Firmware/Bootloader Update Manual

DC POWER SUPPLY. Model: PW-3063R / PW-4063R

CAEN. Electronic Instrumentation. NIM slot 5U CERN Compliant NIM Crate. Rev July Tools for Discovery

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

The 2U package makes the unit suitable for using in workstations, storage systems, racks for industrial and many other applications.

User's Guide. Model W 3-in-1 Switching DC Power Supply

Model Number: DZ300-12EU

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

1.2 Intel Server Chassis SC5400BASE Summary

TXP3500/4000 Series AC-DC Industrial PSU

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

EFE300 / EFE400 EFE300M / EFE400M

EFE300 / EFE400 EFE300M / EFE400M

Stepper motor driver HEM-545 last change:


RT4F-120V/20A-WAC RECTIFIER

User Guide Automatic Transfer Switch (ATS)

The ATF YE meets UL/CSA and all international safety requirements. CE mark is pending. Min Typ Max

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

RT4F-110V/25A RECTIFIER

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-20 PELTIER TEMPERATURE CONTROL SYSTEM

RECTIFIER PSR380 (48V VERSION) USER MANUAL UM_PSR380_48V_E_R1.0

Operating instructions. Speed monitor D / / 2014

MODEL DRIVER Ic Ip VDC

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

RT4F-48V/50A-WAC RECTIFIER

RT4B-110V/12A RECTIFIER

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

G-MAX TM. ATX Series User s Manual

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

Brushless DC Motor Controller Specification Assembly 025A0053

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Thermoelectric Cooler Controller TED1000

E-Series Site Preparation Guide

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

AC-DC Converter REC /60-K20

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

PFC Mini TM Power Factor Corrected AC-DC Switchers

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

CSPS-6K (Shelf Type) POWER you need POWER SHELF

CPCI - 6U - AC - 600W

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

ac wave 2 supply ( analog device )

TFX PC Power Specifications

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

Ultra Low Noise Laser 1550nm

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

CERBERUS. Cerberus multi I/O. Datasheet. Shaping the future of sound reinforcement. Cerberus. Applies to Part Number:

midon design A 1-Wire Multi-purpose Sensor 1WIO Figure 1 MD2083 As-Shipped August 23, WIO User Guide Version 1.

MC 11 EB-2 Power supply cabinet with external bus, AC version

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Manual Control Unit GFC 32

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Service Manual Saprom S

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Other standard features include current and voltage monitoring, overvoltage, overtemperature as well as short circuit protection.

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

AirTest Model CN9000 Series Sensor Controller

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

PAS 9732/AI ENGINEERING SPECIFICATION

Operating instructions. Switching amplifier DN0210 DN / / 2015

NIM / CAMAC Crates User & Service Manual

FMP VDC RECTIFIER 42 Amps 2000 Watts

Laboratory Switch Mode Power Supply Series. Instruction Manual

Home Theater PC Chassis

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

AC-DC Converter RECE K21

Transcription:

W-Ie Ne-R UEP10M005 Power Supply User s Manual UEP10M005-A0

General Remarks The only purpose of this manual is a description of the product. It must not be interpreted a declaration of conformity for this product including the product and software. W-Ie-Ne-R revises this product and manual without notice. Differences of the description in manual and product are possible. W-Ie-Ne-R excludes completely any liability for loss of profits, loss of business, loss of use or data, interrupt of business, or for indirect, special incidental, or consequential damages of any kind, even if W-Ie-Ne-R has been advises of the possibility of such damages arising from any defect or error in this manual or product. Any use of the product which may influence health of human beings requires the express written permission of W-Ie-Ne-R. Products mentioned in this manual are mentioned for identification purposes only. Product names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies. No part of this product, including the product and the software may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means with the express written permission of W-Ie-Ne-R. Kommentar [vh1]: Versionen dieses Dokuments: Wann... [1] January 13 i UEP10M005-A0

Table of contents: 1 DESCRIPTION OF UEP10M005... 1 2 TECHNICAL DATA SUMMARY... 1 2.1 TRIMMER POSITION TOP VIEW... 1 3 OPERATING INSTRUCTIONS... 2 3.1 GLOBAL OPERATIONS... 2 3.2 FAN-OPERATIONS... 3 3.3 POWER-SUPPLY MONITORING AND CONTROL OPERATIONS... 3 3.4 CAN-BUS INTERFACE OPERATION... 4 3.5 ERROR MESSAGE LIST... 6 3.5.1 Run time error messages... 7 4 PIN-ASSIGNMENT... 8 4.1 DC OUTPUT CONNECTOR 75 PIN... 8 4.2 FAN CONNECTOR (EXT.) 15 PIN... 8 4.3 MONITOR CONNECTOR 36 PIN... 8 4.4 CANBUS-CONNECTORS > ITEM 3.4... 8 January 13 ii UEP10M005-A0

1 Description of UEP10M005 The W-Ie-Ne-R UEP10M005 is a linear regulated Power Supply for a special application. Output voltages and load currents accord to the specification of the customer. Mechanical construction fits into a 19 cabinet. The required height is 5 units plus1 unit for air flow. All switches, displays and fuses are located in the front of the unit. The mains plug, the dc output plug, the external fan plug, the monitor plug and the CANbus plugs are mounted on the rear. Two fans are mounted inside the power supply to cool down the power transistors. It is very important to provide a good airflow and to avoid any suppression of free air circulation. The circuit is a classical one of a linear regulated power supply. The bipolar power transistor are driven by a regulator circuit which contains the necessary elements such as references, operational-amplifiers, small signal transistors and the required trimmers. These components are accommodated on two similar boards each regulating one positive and one negative voltage. An additional board provides control functions such as trip off, overload and overtemperature. The required dc-voltages are supplied by a mains transformer via rectifiers and electrolytic capacitors An additional auxiliary power supply drives the mains relay and soft start circuit. A micro controller circuit is built in to achieve comfortable watching over the complete unit. The display and switches in front, the internal- and external fans, the status of power supply, the air temperature and the CANbus are serviced and controlled by this processor circuit. The top- and bottom covers can be removed for access to internal components. Only specially trained personal with the necessary equipment must maintain the power supply. For access to the voltage trimmers the necessary holes in the top cover can be used. Severe malfunction may result adjusting any other trimmer. January 13 1 UEP10M005-A0

2 Technical data summary Input Fuses Noise and ripple 115VAC +10%/-15% 48 63Hz 8A time lag 5x20mm full load <0,6mV eff, 3mVpp, 1mV at 80% rated power Regulation load 10% to 100% <0,05% line +/-10% <0,02% Recovery time Output impedance Derating Temperature error Thermal protection Current characteristics load change 10% to 100% <0,15ms static <0,2mOhm no derating at 50degrees Celsius <200ppm switches on heat sink and transformer current limit adjusted to 115% rated current short circuit current <3A Voltage-range adjustment range >5% (attention: tripoff at 2,5%) Crow bar +/- 7,3V DC outputs U0 +6V 32A U1-3,3V 32A U2 +3,3V 8A U3-6V 8A 2.1 Trimmer position top view U0 U2 U1 U3 January 13 1 UEP10M005-A0

3 Operating Instructions 3.1 Global operations POWER ON/OFF switch up : on (green POWER LED lights) switch down : off SYSRESET not used MODE SELECT switch up : next mode switch down : previous mode On the alphanumeric display in the centre of the front panel the values of fan speed, temperatures, voltages and currents as well as the adjusted voltage and current limits will be shown. To choose between the available modes push the MODE SELECT switch. The following table gives a look about all available modes and shows examples for the displayed values. Mode Voltage Current Description reserved reserved +3V 3.30 2.00 +12V channel -6V 6.00 2.00-12V channel +6V 6.00 30.0 +12V channel -3V 3.30 30.0 +12V channel FANS 3000 RPM Fan Speed PS TEMP 32 C power supply temp. AIR TEMP 28 C fan air inlet temp. POWER 150 W total output power CAENET ADR 16 opt. CAENET interface addr. CANBUS ADR 1 opt. CAN interface addr. SPEED 1 MBAUD CAN: serial link speed GENERAL CALL 127 CAN: general call address January 13 2 UEP10M005-A0

3.2 Fan-operations FAN SPEED switch up : step wise increase of fan speed switch down : step wise decrease of fan speed AUTO OFF switch up : auto off enabled, a fan failure will set off the crate switch down : auto off disabled, a fan failure will not set off the crate, only local and remote warning is given The maximum value of fan speed is up to 3120 rpm. If the speed is lower than 3000 rpm the red SLOW SPEED LED lights. Change of fan speed is possible independently from the displayed mode. If another range of the display was set before pushing the FAN SPEED switch the display shows the speed for 5 sec. and returns back to the previous range. The display shows the nominal speed of the blowers and twinkles if it differs from the given real speed. The yellow FAN FAILURE LED lights in the case of any fan-failure. 3.3 Power-supply monitoring and control operations All present voltage and current values of the several voltage output lines as well as the temperature inside the power supply can be shown on the alphanumeric display of the fan-tray. To select between the display modes push the MODE SELECT switch as given in 2.2. In case of using the linear regulated power supplies (UEP series) it is possible to define the current resolution for each voltage. These values which are stored within the fan-tray unit can be programmed by the following switch algorithm, 1. Switch on fan-tray and select channel (e.g.+12v) with MODE SELECT switch. 2. Switch up both POWER and MODE SELECT switches together for about 5 sec. Then the controlling mode menu including selected channel, and the current resolution will be shown on the display. 3. Change the value by pushing the MODE SELECT switch down (value will decrease) or up (value will increase). 4. To accept the new value switch down POWER. To change the other limits repeat step 1-4. 5. Disconnect mains to end programming. January 13 3 UEP10M005-A0

The following table represents possible values for the current resolution and the standard settings Resolution Full scale current Default for channel 5mV/A 80A +6V/-3,3V 10mV/A 40A 25mv/A 16A +3,3V/-6V 50mV/A 8A Further, it is possible to define the unit behavior after AC on or AC failure. It is possible to select either a general crate is off after connecting to AC or an automatic power on to allow the unit to switch automatically on after AC fail. 1. Switch on fan-tray and select channel POWER with MODE SELECT switch. 2. Switch up both POWER and MODE SELECT switches together for about 5 sec. Then the controlling mode menu including auto power on or no auto power on be shown on the display. 3. Change the value by pushing the MODE SELECT switch down or up 4. To accept the new value switch down POWER. 3.4 CAN-bus interface operation If equipped with the optional CAN-bus interface the front panel is equipped with additional elements for network operation: SWITCHES ADDR CAN - bus crate address LOCAL not used LED - INDICATORS LOCAL green large LED lights if CAN Net OK January 13 4 UEP10M005-A0

The 9-pin Sub-D connector for CAN-bus interfacing is prepared according to CiA DS 102-1: Pin Line Comment 1 - reserved by CiA 2 CAN_L CAN_L bus line (dominant low) 3 GND Ground 4 - reserved by CiA 5 - reserved by CiA 6-7 CAN_H CAN_H bus line (dominant high) 8 - reserved by CiA (failure signal) 9 - To change the CAN-bus address the ADDR switch has to be pressed. The address can be selected within the range 1... 127. The chosen net address is displayed on the fan tray display. If the display has been showing another parameter (voltage, fan speed,...9 before changing the net address it will return to the previous display. To shut the crate for remote control the position CANBUS DISABLED has to be chosen. Within the W-Ie-Ne-R CAN-bus protocol a broadcast call to all connected crates is possible (see CAN-BUS Interface report). The address for this general call is factory prepared 127 however it can be changed by the following procedure: 1. Select display channel GENERAL CALL with MODE SELECT switch. 2. Switch up or down the ADDR switch to change the value. If the crate has to be disabled for general call the position GENERAL CALL OFF has to be selected. January 13 5 UEP10M005-A0

According to the CAN bus specification the data transfer speed is depending on the net length as given within the following table: Max. Distance Bit Rate Type 10 m 1.6 Mbit/s 40 m 1.0 Mbit/s 130 m 500 kbit/s high- speed 270 m 250 kit/s 530 m 125 kbit/s 620 m 100 kbit/s 1300 m 50 kbit/s 3300 m 20 kbit/s low-speed 6700 m 10 kbit/s 10.000 m 5kbit/s To adjust the net speed for a given net length select the bit rate according to this table and set on the crates: 1. Select display channel SPEED with MODE SELECT switch. 2. Switch up or down the ADDR switch to select the required rate. 3.5 Error message list Both, W-Ie-Ne-R power supplies and fan-trays are equipped with micro-processor based monitoring and control units. Thus, any fan or power module failure will be detected and on the alphanumeric display an error message is shown. This is a useful information for trouble shooting. January 13 6 UEP10M005-A0

3.5.1 Error messages during self test after switching on Unit failures CHKS CONF Configuration check sum error CHKS UCAL Check sum error of calibration voltage CHKS ICAL Check sum error of calibration current PROM CONN internal CPU error CHKS ADDR Check sum error of netware address CHKS STAT Check sum error of previous mains on/off status CHKS FAN Fan-tray check sum error 3.5.1 Run time error messages FAN OFF Fan failure TEMP OFF Temperature of power supply too high AC FAIL Failure of ac power (line) January 13 7 UEP10M005-A0

4 Pin-assignment 4.1 DC output connector 75 pin U0 +6V/32A 39/40/41/42/66 Sense 29 U1-3,3V/32A 47/48/49/50/67 Sense 30 U2 +3,3V/8A 55 Sense 31 U3-6V/8A 57 Sense 32 Ground (Common) 43/44/45/51/52/53/56/58/60/63 Sense 26/27 PE (chassis ground) 65 4.2 Fan connector (ext.) 15 pin +Ufan <24V 1/9 -Ufan Gnd. 2/10 Pulse Fan 1 3 Pulse Fan 2 4 Pulse Fan 3 5 4.3 Monitor connector 36 pin Uo Monitor 3 Statusbit 23 U1 Monitor 4 Statusbit 11 U2 Monitor 2 Disable 28 U3 Monitor 5 Inhibit 26 Gnd analog 9 Power fail 12 Rearming + 35 Gnd digital 8 Rearming - 34 4.4 CANbus-Connectors > Item 3.4 January 13 8 UEP10M005-A0

Seite i: [1] Kommentar [vh1] Dr. Lüder von Horn Versionen dieses Dokuments: Wann Was Wer 5. Juli 99 Manual erstellt L. von Horn