6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM

Similar documents
LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

LBO-DVI-AD LINK BRIDGE TM FIBER OPTIC DVI VIDEO CONVERTING TRANSMITTER SYSTEM

LBO-DVI-EAD LINK BRIDGE TM FIBER OPTIC DVI WALL PLATE AND STANDALONE TRANSMITTER SYSTEM

LBH-DVI-2PH Series LINK BRIDGE TM HDBASET DVI TRANSMISSION SYSTEM

4800 Series FIBER OPTIC DVI EXTENSION SYSTEM

LBC-H/V-T-WP LINK BRIDGE TM HDMI/VGA WALL PLATE TRANSMITTER SYSTEM

LBO-DVI Series DIRECTLY PLUGGABLE LINK BRIDGE TM FIBER OPTIC DVI TRANSMISSION SYSTEM

LBC-HDBT-R-DG LINK BRIDGE TM HDBASET HDMI RECEIVER W/POH

LBO-H/V-EAD LINK BRIDGE TM FIBER OPTIC HDMI/VGA WALL PLATE AND STANDALONE TRANSMITTER

LB-HDMI/DE LINK BRIDGE TM HDMI AUDIO DE-EMBEDDER SYSTEM

LB-HDMI/DE LINK BRIDGE TM HDMI AUDIO DE-EMBEDDER SYSTEM

LB-H2-E. Link Bridge 4K UHD + Audio Embedder

LBC-SPH8-1HB7-EIR LINK BRIDGE TM HDBASET 7X TRANSMISSION SYSTEM

LBC-HDV-T LINK BRIDGE TM HDBASET HDMI/DISPLAYPORT/VGA TRANSMISSION SYSTEM

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

LBH-H/V-EAD-T LINK BRIDGE TM HDBASET HDMI/VGA WALL PLATE AND STANDALONE TRANSMITTER

LB-H2-SP2 HDMI 2.0 DISTRIBTUTION AMPLIFIER 1X2 SPLITTER

LBC-H/V-T-WP LINK BRIDGE TM HDMI/VGA WALL PLATE TRANSMITTER SYSTEM

LB-ICP LINK BRIDGE TM INLINE CONTROL PROCESSOR

LBS-42H2 LINK BRIDGE TM 4x2 HDMI 2.0 Matrix Switcher

LBO-H/O-EAD-R-ICP LINK BRIDGE TM OPTICAL/HDMI RECEIVER SYSTEM WITH EXTERNAL AUDIO AND INLINE CONTROL PROCESSOR

LBH-H/O-EAD-R-ICP LINK BRIDGE TM HBASET/HDMI RECEIVER SYSTEM WITH EXTERNAL AUDIO AND INLINE CONTROL PROCESSOR

LBH-SDI-EAD-T LINK BRIDGE TM HDBASET SDI VIDEO CONVERTING TRANSMITTER SYSTEM

LBH-H-T/R-EAD-ICP LINK BRIDGE TM HBASET HDMI TRANSMISSION SYSTEM WITH EXTERNAL AUDIO AND INLINE CONTROL PROCESSOR

LBH-SV-EAD-T LINK BRIDGE TM HDBASET SV/CV VIDEO CONVERTING TRANSMITTER SYSTEM

LBH-H/O-EAD-R-ICP LINK BRIDGE TM HBASET/HDMI RECEIVER SYSTEM WITH EXTERNAL AUDIO AND INLINE CONTROL PROCESSOR

LBC-HDBT-T/R-ICP LINK BRIDGE TM HBASET HDMI TRANSMISSION SYSTEM WITH INLINE CONTROL PROCESSOR

HD-CVI / AHD / HD-TVI Video + Bi-Directional Data

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Serial Data DIN Fiber Link System

RS-232 Industrial Media Converter

USER MANUAL SES-FA4BAL

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

HDMI VIDEO SYSTEM USER S MANUAL

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

Fiber Optic Prism Switch USER S MANUAL

6400 CWDM Series. Fiberlink. 4 or 8 Channel Coarse Wave Division Multiplexers for Single Mode Fiber. User s Manual

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

DVI Extender over single LC Fiber with TMDS video and EDID data.

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

OPERATOR MANUAL OSD8826 SERIES DIGITAL VIDEO AND DATA FIBER OPTIC TRANSMISSION SYSTEM

RS-232 Fiber Link Card System

FIBER OPTIC TRANSMISSION SYSTEM 3730 & 3530 SERIES. Digital Video with Bi-directional/Return Data. User Manual. Infinova

HDMI to DVI with Audio Converter

20W Tungsten-Halogen Light Source. Operation Manual

4 Channel Contact Closure DIN Fiber Link System

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

2 Channel POTS DIN Fiber Link System

5100 Series. Fiberlink. 10/100/1000 Base-T Etheret over one or two single mode or multimode fibers. User s Manual

TSD-DA28 2x8 Balanced Line Distribution Amplifier

OPERATOR MANUAL OSD730 FULL DUPLEX FOUR CHANNEL DIGITAL AUDIO/DATA SYSTEM

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

DVI Extender over Fiber with EMI Shielding

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

PIM-Mini Pulsed Current Source Operation Manual

PDC-X Digital Controller

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

PCM-7140 Pulsed Current Source Operation Manual

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Operation Manual for VXC4000 VXC4000 V

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider. AtlasIED.com

HD-1X4-4K User Manual

OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER

F271XA Fiber-Optic Telephone Modem Technical Manual

User Guide. Control Box. RoscoLED TM.

NT1B-300 Rack Installation Instructions

User Guide. Single-Link DVI Fiber Optic Extender DVI-7315

1 Channel Strobe Controller ORDERCODE 40226

IMS-9000 Intelligent Modem Switch USER S MANUAL. Document Part #: RDC-HDWIMS9K100

2 Channel POTS with I/O DIN Fiber Link System

PRO-DVI-CAT. DVI over Single CAT5 Extender. User Manual. Made in Taiwan

HDMI Extender SET over Single Fiber Optic Cable with EMI Shielding

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter

INSTRUCTION MANUAL ANI-23TCDTX/RX. Analog Stereo Audio & RS-232 over CAT5e/6/7 Extenders. A-NeuVideo.com Frisco, Texas (469)

DVI Extender over Single CAT5 Mini SET

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

DV-HDA-12AUD 1x2 HDMI Distribution Amplifier Manual

MIR-K16S-2101Q IR Distribution Kit with 6 Ports

HDMI Extender over Fiber

Cantata m100 Amplifier

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

HDEXT50M USER MANUAL Extend HD Signals over CAT 5/5e/6 up to 164ft.(50m) All Rights Reserved Version: HDEXT50M_2017V1.2

SATA II HDD Canister KISS DA 435 Quick Reference Guide

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

Owner s Manual. TSD-RL21 2x1 Mic/Line Mixer. TSD-RL21 2x1 Mic/Line Mixer with Remote Level

MPP200 User s Manual

3 Angled Connector Housing (MC) Installation

4 Channel 4-20mA/0-10V Industrial Media Converter

DVI Extender over Single CAT5 Model #: DVI-C5-M-SET

DV-HDA-14AUD 1x4 HDMI Distribution Amplifier Manual

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

Transcription:

00E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM WITH DATA OPTIONS BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability is assumed as a result of their use or application. All rights reserved. 00 Broadata Communications, Inc.

BCI 00E User s Manual SAFETY INSTRUCTIONS AND COMPLIANCE DECLARATIONS PLEASE OBSERVE THE FOLLOWING SAFETY PRECAUTIONS AS OUR PRODUCTS CONTAIN CLASS I LASER PRODUCTS WARNING Do not disconnect the fiber optic connector while the unit is powered up. Exposure to laser radiation is possible when the laser fiber optic connector is disconnected while the unit is powered up. Although the fiber optic connectors in this product emit only Class energy that is below the levels considered to be hazardous, one should never stare directly into a fiber optic connector or an unconnected fiber end unless one can be certain that no exposure to laser energy could occur. CAUTION This manual is intended for use by trained service personnel. The use of controls, making adjustments, or performing operations other than those specified may result in hazardous radiation exposure. The following label or equivalent is located on the surface of laser products. This label indicates that the product is classified as a CLASS LASER PRODUCT. CLASS LASER PRODUCT SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical spikes, surges, electric shock, lightning strikes, etc. Use of surge protection systems is highly recommended in order to protect and extend the life of your equipment. Broadata Technical Support, CustomerService@Broadatacom.com

BCI 00E User s Manual TABLE OF CONTENTS.0 PRODUCT DESCRIPTION....0 SETUP.... MOUNTING.... CABLING AND CONNECTORS...9.. AUDIO CABLE CONNECTION...9.. OPTICAL FIBER CONNECTION.... AC POWER CONNECTION....0 OPERATION....0 MAINTENANCE AND TROUBLESHOOTING.... MAINTENANCE.... TROUBLESHOOTING....0 SPECIFICATIONS....0 SERVICE PROCEDURE...0. REPLACEMENT POLICY...0. RETURN AND REPAIR SERVICE...0.0 LIMITED WARRANTY... Broadata Technical Support, (00) -0

BCI 00E User s Manual.0 PRODUCT DESCRIPTION The 00E Series provides simultaneous transmission of multiple channels of digitized audio over one or one pair of fiber. The standard 00E system comes with -, -, and -channel versions and transmits these audio channels in one direction. Models up to -channels are also available as a custom version. Many versions of optical transmitter and receiver combinations are available to address different distance requirements. The 00E features a digital fiber optic transmission technology, capable of providing crisp audio, little or no maintenance, high functional reliability, and low operating costs. The quality of BCI's audio transmission digital design is much superior to the analog transmission counterparts (based on amplitude or frequency modulation) available from other manufacturers. In addition, no user adjustments are required in the 00E system, enabling quick setup and trouble-free operation. The 00E is available with two packaging options: a rugged, standalone, and compact unit, or a plug-in card for a card cage system. Panel connectors are provided for audio (terminal block) and fiber connection (FC-type for singlemode fiber or ST-type for multimode fiber). They are also easily monitored by separate LED indicators for power, optical link, and channel activity. Due to its digital transmission design, the 00E is capable of addressing a variety of non-standard configurations. Contact us to discuss your custom, OEM/private brand and high volume requirements. Figures - through - illustrate the connections, LED indicators, and other elements displayed in the front and rear panels of the 0E and E. The E is a -channel audio version and the 0E is our -channel audio version. The 0E is a subset of the 0E and is the -channel audio version. Broadata Technical Support, CustomerService@Broadatacom.com

BCI 00E User s Manual RX 9 0 PWR 00E-T 9 0 A U D I O + - I N P U T S CHANNELS VDC Figure - E-T Front/Rear Panels 9 RX 0 9 0 A U D I O PWR 00E-R LINK O U T P U T S + - CHANNELS VDC Figure - E-R Front/Rear Panels Broadata Technical Support, (00) -0

-- BCI 00E User s Manual RX 00E A U D I O I N P U T S PWR CHANNELS VDC Figure - 0E-T Front/Rear Panels RX PWR 00E A U D I O O U T P U T S RX LINK + -- + CHANNELS + -- + - VDC Figure - 0E-R Front/Rear Panels Broadata Technical Support, CustomerService@Broadatacom.com

BCI 00E User s Manual.0 SETUP The BCI 00E Series units are used in pairs. One 00E-T transmitter unit is located at the near end and connected to an identical 00E-R receiver (0E or E, respectively) located at the far end of the link through two optical fibers. Each unit provides a separate electrical interface connector for the audio data signals. Connections are one to one between both units. Figure - depicts a typical installation. Figure - 00E Series Setup. Mounting Before installing the units into your housing, make sure there is enough space to pull and connect both the electrical and optical cables without stressing them beyond the manufacturer s limitations (also known as the bend radius minimum). Rack Mount kits are available through special order. Broadata Technical Support, (00) -0

BCI 00E User s Manual. Cabling and Connectors In order to setup the BCI 00E properly, make sure to observe the following instructions when installing the proper cables. The 00E requires two parts to the cabling setup: the audio and the optical... Audio Cable Connection The only cable connections on the electrical side are for the terminal block audio interfaces. To connect the audio component, connect your terminal block connectors to the appropriate channels, as illustrated in Figure -. The pinout assignment for the terminial block connector is shown in Figure -. 00E-T Unit CHANNELS One Level Audio Receiver RX PWR 00E-T 9 0 9 0 00E-T A U D I O I N P U T S Audio Cable with Terminal Block Connector One Fiber Cable To 00E-R Unit Audio Cable with Terminal Block Connector Figure - Audio Connection Broadata Technical Support, CustomerService@Broadatacom.com 9

BCI 00E User s Manual RX A U D I O I N P U T S 00E PWR CHANNELS Ch Ch Ch Ch Ch Ch Ch Ch + + _ G + _ G + + + _ G + _ G + J J Figure - Terminal Block Pinout Assignment RX A U D I O I N P U T S 00E PWR CHANNELS Pin CH (+) Pin CH (-) GND Pin CH & Pin CH (+) Pin 9 CH (-) Pin CH (+) Pin CH (-) Pin CH & GND Pin CH (+) Pin 0 CH (-) Table 00E-T/00E-R Terminal Block (J) Pinout 0 Broadata Technical Support, (00) -0

BCI 00E User s Manual RX A U D I O I N P U T S 00E PWR CHANNELS Pin CH (+) Pin CH (-) GND Pin CH & Pin CH (+) Pin 9 CH (-) Pin CH (+) Pin CH (-) Pin CH & GND Pin CH (+) Pin 0 CH (-) Table 00E-T/00E-R Terminal Block (J) Pinout The following sections provide installation procedures for connecting 00E audio channel interfaces. Please refer to Figure -. The audio interface in the 0E/E system supports transmission of eight/sixteen channels of high fidelity audio, respectively. Line-level audio signals are connected to the 00E units over balanced terminal block cable. Use the following steps for transmission of high-fidelity audio:. Connect and label or terminal block cables to the output connectors of the or line-level audio sources to be sent.. Connect the terminal block cables of the or signals to be transmitted to the corresponding 00E-T rear panel terminal block female receptacles labeled channels,,, /.. Repeat Steps and for the receiver end (00E-R). Broadata Technical Support, CustomerService@Broadatacom.com

BCI 00E User s Manual. Connect the terminal block cables of the or signals to be received to the corresponding 00E-R rear panel terminal block male receptacles labeled channels,,, /. Connect and label these or terminal block cables to the input connectors of the or line-level audio receivers/amplifier... Optical Fiber Connection Most cable manufacturers identify individual fibers in the fiber cable. Select an appropriate terminated fiber. Each unit s optical ports in the system are specified for use with Multimode (./ micron) fiber, or Singlemode (9/ micron) fiber. Follow the ensuing instructions for installing and connecting the fiber optic links:. Ensure the power is off before proceeding with the fiber optic cable installation.. Prior to connecting the fiber optic cables, remove and save the dust caps from the optical port of both the 00E units. Wipe the inside of the sleeve with a lint-free pipe cleaner moistened with regent-grade isopropyl alcohol. Clean the fiber optic connector and use a lint-free cloth dampened with alcohol to thoroughly wipe the side and end of the ferrule. Table shows the connection mechanisms for both ST and FC connectors.. Connect the fibers from one unit to the other connecting the near end 00E unit s optical port to the far end 00E unit s optical RX port as illustrated in Figure -. Observe the type of connector you have and connect the optical connector by following the instructions and guidelines from the legend provided below. Broadata Technical Support, (00) -0

BCI 00E User s Manual 00E-T Unit RX PWR 00E-T 9 0 9 0 One Fiber A U D I O I N P U T S RX + PWR -- CHANNELS 9 0 LINK 9 00E-R + 0 A U D I O -- O U T P U T S + 00E-R Unit -- + - CHANNELS Figure - Fiber Optic Connection Connector Illustratio n Description ST FC SC * * * Hold the connector by the strain-relief boot* and insert the connector ferrule into the port. Rotate the boot until the "key" engages in the slot of the coupling. Push the connector housing forward until it can be turned clockwise to latch to the port. Hold the connector by the strain-relief boot* and insert the connector ferrule into the port. Rotate the boot until the "key" engages in the slot of the coupling. Push the connector housing forward and screw clockwise until it is tight. Hold the connector by the connector casing* and insert the connector into the port. Make sure the key, signified by the notch on one side of the connector aligns with the connector on the fiber optic equipment. Table Fiber Optic Connector Legend Broadata Technical Support, CustomerService@Broadatacom.com

BCI 00E User s Manual. AC Power Connection Congratulations! You are now ready to power up the BCI 00E and set up your network connection. In order to make sure that you have a proper installation, please observe the following:. Your AC jack has power.. Your electrical system has proper grounding (this ensures that your power supply does not suffer from voltage variations).. Power Surge Protection. This is optional, but highly recommended. A UPS system provides voltage regularity as well as prevents spikes from occurring, thus protecting your 00E from sensitive voltage conditions. The 00E derives power from an external VDC/.A power supply (0E and 0E) or from an internal 9-0 VAC/.A power supply (E). This power supply comes standard for the 00E unless otherwise specified. To provide power to the 00E, simply connect the power cord, already provided with the units, and connect it to the wall jack. (You will find one power cord per unit). Once the power cord has been connected to the wall jack, connect the other end to the unit. Once the power cord has been connected, turn the switch ON (I) on the provided back panel. If you have any problems or concerns, regarding the installation, make sure that you have taken the proper steps to ensure a proper power connection. Otherwise, feel free to contact us for any questions you may have. Broadata Technical Support, (00) -0

BCI 00E User s Manual.0 OPERATION After the installation procedure is completed, the units are ready for operation. To operate the 00E units, simply apply power as indicated in the previous step. Note that the front panel link status indicator, shown in Table, will be activated. Power Optical Link Audio Out Audio In This RED LED indicates that the 00E-T or 00E-R unit is connected to a power source and the unit is switched on. The ON state of this GREEN LED on the 00E-R unit indicates that the fiber optic cable is properly connected and that optical transmission is operating between the 00E-T and the 00E-R units. This GREEN LED FLASHES ON when the 00E-R transmits audio signals to the user's audio receiver equipment. This GREEN LED FLASHES ON when the 00E-T receives audio signals from the user's audio source equipment. Table Status Indicators Broadata Technical Support, CustomerService@Broadatacom.com

BCI 00E User s Manual.0 MAINTENANCE AND TROUBLESHOOTING. Maintenance There is no operator maintenance other then keeping the units clean. However, observe the light indicators (shown in Table ) to make sure that the unit is working properly.. Troubleshooting If the BCI 00E units do not operate properly after installation, check for possible cable breaks, loose connections, and incorrect cable connections. If a problem exists on the fiber link, please check your fiber connectors for improperly cleaned fiber cables and connectors. If problems persist that may be fiber related, contact BCI at -00--0 for further assistance. For electrical problems, perform the following troubleshooting procedures:. If the POWER indicator is OFF, check for the following: a. The line cord is plugged into the unit and your outlet has power. b. The 00E unit is switched on. c. Check for blown fuses (located in the rear panel-entry module).. If the POWER indicator is ON, but the Optical Link indicator is OFF, check for the following: a. Make sure the appropriate (singlemode or multimode) fibers are being used. Broadata Technical Support, (00) -0

BCI 00E User s Manual b. Fiber and fiber connectors are not broken. Ensure that the optical loss does not exceed the specified optical power attenuation (see Section.0 Specifications for the optical power budget). c. For each unit, the transmit () fiber is connected to the other unit s receiver (RX).. If the POWER indicator and Optical Link indicator are ON, but the audio/video channels are not operating, then: a. Check to see that the attached user equipment is turned on. b. Both ends of the link are connected to the corresponding equipment and to the same corresponding channel port. c. Cable connections at both the video/audio channels are securely fastened to each connector. Turn the power off, then back on to reset the link. d. Output levels of the user s video and audio sources are not above the allowed input levels of the 00E units (see Section.0 Specifications). Broadata Technical Support, CustomerService@Broadatacom.com

BCI 00E User s Manual.0 SPECIFICATIONS Audio Channel Capacity,, or (Standard) (Custom) Operating Mode Balanced/Unbalanced Input/Output Impedance 00/00 Ohms (Balanced) Max. Input/Output Level+0dBm @ 00 Ohms (Balanced) Magnitude Freq. Response 0Hz to 0kHz @ -db SNR (Weighted) 0dB @ khz, 0dBm Input Level (Balanced) Connector Terminal Block Serial Data Channel Number Signal Format RS- or RS- Data Rate Up to Kb/s Connector Terminal Block Physical Dimension: (H x W x D) Standalone*.'' x.'' x.0'' Standalone**.'' x.0'' x.0'' Card-cage Plug-in Card. x 0.9 x. Power + VDC @. A ( or -ch) Operating Temperature 0 to +0 o C Humidity 0 to 9% RH, non-condensing Status Indicators Power, Optical Link, Audio Activity Broadata Technical Support, (00) -0

BCI 00E User s Manual * For - or -channel, and for -channel unidirectional ** For -channel bi-directional Optical Fiber Type Multimode and Singlemode Number of Fibers Wavelength 0 and/or 0 nm Fiber Optic Connector ST (Multimode) FC (Singlemode) Broadata Technical Support, CustomerService@Broadatacom.com 9

BCI 00E User s Manual.0 SERVICE PROCEDURE. Replacement Policy Standard products found defective on arrival (DOA) will be replaced, based on availability, within to hours anywhere in the U.S. Please call Customer Service at 00--0 for information.. Return/Repair Service The 00E System contains no user serviceable components. If you have a problem with your unit, please contact the Customer Service Department. To facilitate our return/repair processing please contact Broadata Communications, Inc. to obtain a Return Material Authorization (RMA). Please include the following information: Product model number Serial Number Complete description of problem Hardware installation description Broadata Communications, Inc. West th Street, Suite K Torrance, CA 900-00--0 (0) 0- (0) 0-9 (Facsimile) e-mail: CustomerService@Broadatacom.com Website: www.broadatacom.com 0 Broadata Technical Support, (00) -0

BCI 00E User s Manual.0 LIMITED WARRANTY Broadata Communications, Inc. (BCI) warrants, for a period of one year from date of shipment, each product sold shall be free from defects in material and workmanship. BCI will correct, either by repair, or at BCI s election, by replacement, any said products that in our sole discretion prove to be defective and are returned to the manufacturing location within 0 days after such defect is ascertained. All warranties are limited to defects arising under normal use and do not include malfunctions or failure resulting from misuse, abuse, neglect, alterations, electrical power problems, usage not in accordance with product instructions, improper installation, or damage determined by BCI to have been caused by the Buyer or repair made by a third party. Limited warranties granted on products are to the initial customer end-user and are not transferable. OUR LIABILITY UNDER THIS WARRANTY SHALL IN ANY CASE BE LIMITED TO THE INVOICE VALUE OF THE PRODUCT SOLD AND BCI SHALL NOT BE LIABLE TO ANYONE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM THE USE OF ITS PRODUCTS OR THE SALE THEREOF. We make NO WARRANTY AS TO THE MERCHANTABILITY OF ANY GOODS, OR THAT THEY ARE FIT FOR ANY PARTICULAR PURPOSE OR END APPLICATION NOR DO WE MAKE ANY WARRANTY, EXPRESSED OR IMPLIED OTHER THAN AS STATED ABOVE. Broadata Technical Support, CustomerService@Broadatacom.com

BCI 00E User s Manual Broadata Technical Support, (00) -0

000E-00-C Broadata Communications, Inc. West th Street, Suite K Torrance, CA 900-00--0 (0) 0- (0) 0-9 (Facsimile) e-mail: CustomerService@Broadatacom.com Website: www.broadatacom.com