ACP 1703 Ax 1703 CM Fieldbus Interface Ring (3x FO, 1x el.)

Similar documents
Manual Fiber Optic Interfaces

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

Accessories / 7XV5461

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

SICAM RTUs. PS-663x. Power Supply Modules 24-60/ VDC (EMC+)

SHEET. AI-FR Series Redundant Fibre Ring Hubs. AI-FR Series. Compatible with the baseband 2.5 Mbps ARCNET network

Data Sheet Rev DALLIS Serial Data

HARTING econ 3000 Introduction and features

PA ROUTERS. The following criteria can be applied when choosing the network transition:

Accessories / 7XV5662

Installation Manual rev

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

FL MC 2000E (SM40) LC

Industrial Switches Industrial Switches

ACP 1703 Platforms. Automation Units and Automation Networks DC Preface, Table of Contents. Configuration of Automation Units 1

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 5 kilometers

TCP. Control and Protection Terminal Data sheet

RightWON Satellite Ethernet switch module (ESM), multi-mode

10/100 AUTO-SENSING MEDIA CONVERTERS

Media Converters. Media Converters. Product Selection Guides

Converter Box Data Sheet

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

MED102A. Industrial Serial to Single-mode Fiber Converter

MC-4TX Series Industrial 4 Port Ethernet to Media Converter. Industrial 4 Port Ethernet to Fiber Media Converter. Part of GE Security

Optic Fiber Comverters DSC POWER, PARADOX EVO, SATEL INTEGRA Buses FIWRE-S-PDS BOX* BOX + DIN35-LOCK* ** BUS supply

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

GEVISTA. CWDM Pluggable OC-48 SFP Transceiver. Description

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

ADAM Fiber Optic to RS-232/422/485 Converter

B Dyx ope mec n S in er g ies Dymec Models operate as Features Dymec Ethernet Links 3340/3350 & Links and Repeaters, optically 3344/3354

7SG18 Solkor N Numeric Differential Protection

Industrial Media Converters

Optimux-4T1 Four-Channel T1 Multiplexer

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

Fieldbus Extender for DeviceNet

. PC cards for all common fieldbus. systems Industrial Ethernet switches. . EtherCAT junctions and media converters in IP 20 and IP 67 ratings

PROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05

ICF-1150 Series Quick Installation Guide

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

M1600 Parallel Input / Output

Brief instruction. Version. 3en.

114FX6. Phone: Fax: Web: -

VCL-TP, Teleprotection Equipment

308FX2-N. Phone: Fax: Web:

Volition. Fast Ethernet Fiber Optic Media Converters. Installation Manual VOL-0205/VOL-0206 /VOL-0207/VOL December

PHOENIX CONTACT - 10/2009

317FX-N. Phone: Fax: Web: -

STF-502C Series High Performance Dual Fiber Industrial Serial-to-Fiber Converter User Manual

Industrial 3-Port Fast Ethernet Media Converter Switches

Proteus Node Return Digital Transmitter with Ethernet

Serial Data DIN Fiber Link System

TCF-142-RM Series Hardware Installation Guide

Accessories / 7XV5820

Optimux-34, Optimux-25

ICF-1150 Series Quick Installation Guide

Optimux-1032, Optimux-1025

305FX-N. Phone: Fax: Web:

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

PSI-MOS-PROFIB/FO 850 T

PSI-MOS-PROFIB/FO 850 T

2G-1.1.0, 200M-2.0.3, 200M-1.0.1

Extract from the online catalog

Features and Benefits. Certifications

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

WaveLine managed switches with IOs

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Fibre Optic and Wireless Solutions

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors

IFC-FDC, IFC-FDC-E Industrial Fiber Converter

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

MEDIA CONVERTERS AND CHASSIS

4897 Bus Extender. Hostile Environment, Noise Immunity and Data Security

Product type designation. General information. Supply voltage. Input current

General information. Display. Control elements. Supply voltage

Optimux-34 Fiber Optic Multiplexer

PTC-101 Quick Installation Guide

Remote Bus Extender Slave Module

IMC-P111FX / IMC-P111P Series

General information. Configuration control. Display. Control elements. Supply voltage

Fieldbus slave modules w/o I/Os

CPU module for zone 2 Series 9442/35

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

HARTING scon Introduction and features

Allen-Bradley 1786-RPFRXL

The configuration of the features can be done by the network management or the integrated configuration switches.

Transcription:

ACP 1703 Ax 1703 CM-0821 Fieldbus Interface Ring (3x FO, 1x el.) Bus interface for an optical field bus or multi-point traffic as optical ring or optical star Features: 3 optical transmitter and receiver for each channel (ST-connector) for optical fibres up to 1300m long 1 electrical interface V.28 (RJ45-plug) for patch cable up to 3m long Transmission rate max. 115.2kbps Power supply alternatively via the electrical interface, or via PS-663x or PS-6621 Copyright Siemens AG 2007 MC0-031-2.01

Application CM-0821 is used for the construction of networks with optical or electrical branching (signal add/drop to/from ring): Modes of operation IEC 60870-5-101 Balanced Point-Point (point-to-point-traffic, full-duplex) IEC 60870-5-101 unbalanced multi-point (multi-point traffic) IEC 60870-5-103 unbalanced multi-point (multi-point traffic) Network structure Ring redundant masters (redundant) bi-directional communication in the ring signaling of a ring interruption Star, tree redundant masters Up to 115.2 kbps transmission rate 3 optical transmit and receive channels Receive channel stuck at zero monitoring 1 electrical interface V.28 Power supply Via the electrical interface can supply power to one module only PS-6630 or PS-6632 redundant power supply is supported (but not to increase power) PS-6621 Not more than 6 CM-0821 modules on a power supply PS-663x or PS-6621 Differences between versions --, -A, -B, -C, -D At present there are three versions of CM-0821 with the following differences Version -- Version -A Version -B/ -C / -D Item numbert GA0-821-- GA0-821-A GA0-821-B / -C / -D Designation in data sheet CM-0821-- CM-0821-A CM-0821-B / -C / -D Supported configurations Star Star ring, star Redundant masters Star Star ring, star Balanced point-point from version -D Recognizable outside differences DIP-switch S2 not present DIP-switch S2 has 2 switches DIP-switch S2 has 3 switches 2 ACP 1703 Ax 1703, CM-0821

Configurations Star, singular master, up to max. 2 slaves Master Slaves Star, redundant masters, > 2 slaves redundant masters Slaves CH3 CH3 1 2 3 6 CH3 CH3 Slaves PS-663x PS-663x CM-0821 CM-0822 ACP 1703 Ax 1703, CM-0821 3

Ring, redundant masters redundant masters Slave Slave Slave Slave Further configurations see ACP 1703 Platforms Configuration Automation Units and Automation Networks. 4 ACP 1703 Ax 1703, CM-0821

Features Ring 1 CM-0821 per branch Supports redundant masters (2 branches) Channels 3 (CH3, optical) and 4 (, electrical) together can be set for a connection in direction to a master or in direction to the slaves Channel 3 (CH3, optical) transmission rate for stuck at zero monitoring can be set using DIP switch line-idle state can be set using DIP switch Using channels 1 () and 2 (), the ring is made Features Star / Tree 1 CM-0821 and up to 7 CM-0822 can be attached side by side Supports redundant masters (optically and electrically connected) Channels 3 (CH3, optical) and 4 (, electrical) together are set for a connection in direction to a master Channels 1 () and 2 () connect to one slave each Optical channels transmission rate for stuck at zero monitoring can be set using DIP switch line-idle state can be set for each interface using DIP switch Protocol Elements that support Power Supply and Signaling The following protocol elements support supplying power to the CM-0821 and signaling a ring interruption over the serial interface: Protocol Elements SM-2551/UMPMA0 SM-2551/UMPSA0 SM-2551/SFBMA1 SM-2551/SFBSA1 SM-2551/103MA0 SM-2551/103SA0 Designation Standard Protocol for Multi-Point Traffic Standard Protocol for Field Bus Standard Protocol for Interfacing of Protective Devices ACP 1703 Ax 1703, CM-0821 5

Block Diagram (Module) 6 ACP 1703 Ax 1703, CM-0821

Block Diagrams Data Flow Ring from/to either master or slave CM-0821 Rx_3 Tx_3 Rx_4 Tx_4 TTL_ Bus ring administrator Tx_1 Rx_1 Tx_2 Rx_2 ring Star / Tree (Module Row) from/to redundant masters from/to slaves CM-0821 Rx_3 Tx_3 Rx_4 Tx_4 CM-0822 Rx_3 Tx_3 Rx_4 Tx_4 TTL_ Bus TTL_ Bus Tx_1 Rx_1 Tx_2 Rx_2 Tx_1 Rx_1 Tx_2 Rx_2 from/to slaves ACP 1703 Ax 1703, CM-0821 7

Technical Specifications Interfaces Optical interfaces channel 1 (, X1/X2) channel 2 (, X3/X4) channel 3 (CH3, X5/X6) Electrical interface channel 4 (, X8) Multimode glass fibre optic: (1) 50/125µm fibre (typ. 2.3dB/km) max. 115.2kbps (2) 62.5/125µm fibre (typ. 3.0dB/km) max. 115.2kbps In a ring configuration, because of higher data rate, a 62.5/125µm fibre must be used in the ring. Transmitter (820nm): Power launched into the fibre: max min Receiver (820nm): (1) -13.8dBm -18.8dBm (2) -10dBm -15dBm Received power: max min Data rate R D: (1), (2) -10dBm -40dBm max. 115.2kBit/s Line lenghts (3dB system reserve): (1) 0.. 0.5km (2) 0.. 1.3km in the ring 0.. 1.5km else V.28 asynchronous Status signal for ring interruption signaling allwos to supply power via the electrical interface For connecting patch cables (RJ45 connector), 3m maximum length Data rate max. 115.2kBit/s Signal propagation delays Ring in the Ring ( ) add to ring (CH3/ /) drop from ring (/ CH3/) in the optical fibre T [µs] = 8,65 + (6,25*10 5 ) / R D [Bit/s] T CH3/ / [µs] = 4,78 + (5*105) / R D [Bit/s] T / CH3/ [µs] = 11,5 + (6,25*10 5 ) / R D [Bit/s] Approx. 5ns/m (approximate value) The signal propagation delays do not depend on direction. Note: In order to obtain the total signal propagation delay from one master to one specific slave, the above mentioned signal propagation delays and the signal propagation delay of all fibre optics sections have to be taken into consideration (see an example in ACP 1703 Platforms Configuration Automation Units and Automation Networks) 8 ACP 1703 Ax 1703, CM-0821

Signal propagation delays Star / Tree Between CH3/ in the CM-0821 and an optical channel in the same CM-0821 ( ) in a CM-0822 of the same row (//CH3/) in the optical fibre T CH3/ / [µs] = 4,78 + (5*105) / R D [Bit/s] T CH3/ CM-0822/CHx [µs] = 4,78 + (5*105) / R D [Bit/s] approx. 5ns/m (approximate value) The signal propagation delays do not depend on direction. Note: In order to obtain the total signal propagation delay from one master to one specific slave, the above mentioned signal propagation delay (in cascaded structures: repeatedly, if applicable) and the signal propagation delay of all fibre optics sections have to be taken into consideration (see an example in ACP 1703 Platforms Configuration Automation Units and Automation Networks) Power Supply Operating voltage 3.5.. 5.25 VDC, typ. 0.5W.. 1W (depending on the set line-idle state) Mechanics and Connectors Optical interfaces Ring channel 1 (, X1/X2) channel 2 (, X3/X4) channel 3 (CH3, X5/X6) Star / Tree channel 1 (, X1/X2) channel 2 (, X3/X4) channel 3 (CH3, X5/X6) Electrical interface DIP switch Dimensions Weight Power to be supplied by PS-663x or PS-6621 Multimode optical fibre (2) Multimode optical fibre (2) Multimode optical fibre (1), (2) Multimode optical fibre (1), (2) Multimode optical fibre (1), (2) Multimode optical fibre (1), (2) channel4 (, X8) RJ45 8-pin according to IEC 60603-7 8 switches ST compatible ST compatible ST compatible ST compatible ST compatible ST compatible 131 x 63 x 73 mm (H x W x D, dimensions w/o DIN rail) Approx. 160 g ACP 1703 Ax 1703, CM-0821 9

Engineering Front View CM-0821-- CM-0821-A 10 ACP 1703 Ax 1703, CM-0821

CM-0821-B / -C / -D Connectors CM-0821--, CM-0821-A, CM-0821-B / -C / -D ACP 1703 Ax 1703, CM-0821 11

Settings CM-0821-- 12 ACP 1703 Ax 1703, CM-0821

CM-0821-A ACP 1703 Ax 1703, CM-0821 13

CM-0821-B / -C / -D 14 ACP 1703 Ax 1703, CM-0821

Literature ACP 1703 Platforms Configuration Automation Units and Automation Networks Data Sheet SM-x551/PROTOCOL Data Sheet CM-0822 Data Sheet CM-0823 Data Sheet PS-663x DC0-021-2 MC0-003-2 MC0-033-2 MC0-034-2 MC6-027-2 ACP 1703 Ax 1703, CM-0821 15

16 ACP 1703 Ax 1703, CM-0821