Add 10/100 copper ports to a High Density Media Converter Chassis.

Similar documents
Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

Choose from four different ways to power these hardened media converters.

These tiny media converters are perfect for bringing fiber to the desktop.

Multi-Power Miniature Media Converter 10/100/1000

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

PC Media Converter, Switching (TP-TX/FX)

Connects 1000BASE-T twisted-pair to 1000BASE-SX/LX fiber.

Converts any fiber optics type interface to any other fiber optics type interface.

Industrial SFP/SFP Multi-Power Mode Converter

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Giga-MiniMc TX & RX USER MANUAL

10/100 Autosensing PC Media Converter

Giga-MiniMc TX/FX Giga-MiniMc TX/SFP. Operation Manual

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual

PoE Giga-McBasic PoE+ Giga-McBasic with LFPT. Operation Manual

Bridge Module. Installation Guide and Users Reference Manual

MiniMc TP-TX/FX MiniMc TP-TX/SFP. Operation Manual

IE-iMcV-2xLIM, TX/SFP. Operation Manual

International Headquarters. European Headquarters

FiberLinX Modules Hardware Installation Manual

About PoE Compact Media Converters

Giga-MiniMc with LFPT. Operation Manual

IE-Giga-MiniMc. Operation Manual. FCC Radio Frequency Interference Statement. Limited Lifetime Warranty

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

imcv-ds3/e3/sts Repeater

5/8 Port Gigabit Ethernet Switch

Modular Media Converter Installation Guide (includes 10 Mbps Ethernet, 100 Mbps Fast Ethernet and Protocol-Independent Fiber Mode Conversion Modules)

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

Owner s Manual. Media Converters

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

HES-3106-PLUS SERIES

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

8 Port Gigabit Ethernet Switch User Manual (P/N: 41NE-G3800UD0-A00)

LineTerm SFP and 1x9. Operation Manual

USB USB Data Transfer

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

FCC Statement. Trademarks. Preface. Gigabit Ethernet Media Converter

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

FWRIII-2105 SERIES. 4 ports 10/100Mbps RJ-45; built-in IEEE802.11n WiFi and 1 port 100Mbps SFP slot uplink Residential Gateway. Residential Gateway

IE-iMcV-VDSL2-LANextender. Operation Manual

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

LVN5200A-R2, rev. 1, Hardware Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

IE-MediaChassis/1. Operation Manual

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Raven Series Standalone Media Converters

SP-PoE Splitter User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

High Density Media Converter System II 20-Slot Rackmount Chassis

Gigabit Ethernet Media Converter

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

MC100FX-TX-PoE Media Converter User Manual

International Headquarters

Perle Gigabit Media Converter Module. Installation Guide P/N

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

User Guide TL-SM321A / TL-SM321B. 1000Base-BX WDM Bi-Directional SFP Module. Rev:

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

FRG-3105 Series Residential Gateway

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

G.SHDSL NTU DECEMBER 2006 LB510A

4. 4 x Foot Pads 5. Rack-Mount Kit

Switch manual Models &

HD40H(X) Performance Series Camera. User Guide

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

16-SLOT IN-BAND MANAGEMENT CHASSIS

1000Base-SX (SC) Multi-Mode Fiber Gigabit PCI Express Card PEX1000MMSC

Allworx Tx 92/24 Telephone Expander Installation Guide

Express All-Fiber DVI. User s Manual (For M1-1000)

IFS MC201-1P/1FS User Manual

Gigabit Ethernet Media Converter

Quick Start Guide. Cisco Compatible 10Gbase-LR SFP+ Transceiver with DDM, SMF, 1310 nm, 10 km, LC. Model: N286-10GLR-SLC PROTECT YOUR INVESTMENT!

MARQUE: TP-LINK REFERENCE: TPL_TLSF1016D CODIC:

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

Perle Protocol Transparent Media Converter Modules

Signamax Connectivity Systems Gigabit Ethernet SFP Media Converter

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C)

BTK-A21 Bluetooth Headset User Manual

Wireless Palm Style Keyboard with Touchpad PKA-1720A. User s Manual. Version /08 ID NO:

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

NA502 Multiple RF Home Gateway

10/100BASE-TX to 100BASE-FX Media Converter. User s Guide. Rev. 01 (JUN. 2002) 1907M110MM16003 RECYCLABLE

W INSTRUCTION MANUAL: Q7TEH1026G

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

SNMP Management Module USER MANUAL

FCN-3112 Series. 10/100/1000TX to 1000SX SNMP Managed Media Converter. Version 1.0 User Manual

AX3000 Platine Terminal Ethernet TCP/IP

Transcription:

LMC5605C LMC5603C-SC-2KM LMC5603C-SC-40KM LMC5603C-50SC-40KM LMC5604C-1SFP LMC5603C-ST-5KM LMC5603C-10SC-20KM LMC5603C-2SFP LMC5603C-SC-5KM LMC5603C-50SC-20KM LMC5603C-ST-2KM LMC5603C-ST-40KM LMC5603C-10SC-40KM HDMCII 10/100 TX Modules Add 10/100 copper ports to a High Density Media Converter Chassis.

FCC and IC RFI Statements FCC and Industry Canada RF Interference Statements Class B Digital Device. This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or telephone reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult an experienced radio/tv technician for help. CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. To meet FCC requirements, shielded cables and power cords are required to connect this device to a personal computer or other Class B certified device. This digital apparatus does not exceed the Class B limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Page 2 724-746-5500 blackbox.com LMC5605C

Certifications Certifications Class 1 Laser product, Luokan 1 Laserlaite, Laser Klasse 1, Appareil A Laser de Classe European Directive 2002/96/EC (WEEE) requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste. This symbol indicates that the equipment should be disposed of separately from regular household waste. It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities. Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about proper disposal, please contact local authorities, waste disposal services, or the point of purchase for this equipment. LMC5605C 724-746-5500 blackbox.com Page 3

Table of Contents Table of Contents Part Numbers... 5 1. Specifications... 6 2. Overview: About the HDMCII 10/100 TX Modules... 7 2.1 Priority Queuing... 7 2.2 Flow Control... 7 3. Install the HDMCII 10/100 TX Modules... 8 3.1 Managed Modules... 8 3.2 Unmanaged Modules... 8 4. Operation... 9 4.1 Port LEDs... 9 4.2 HDMCII 10/100 TX/5... 9 4.3 HDMCII 10/100 TX/4 + SFP... 10 4.4 HDMCII 10/100 TX/3 + SFP... 11 4.5 HDMCII 10/100 TX/3 + FX... 12 5. Contacting Black Box... 13 6. Fiber Optic Cleaning Guidelines... 14 7. Electrostatic Discharge Precautions... 15 Page 4 724-746-5500 blackbox.com LMC5605C

Part Numbers Part Numbers Part Number LMC5605C LMC5604C-1SFP LMC5603C-2SFP LMC5603C-ST-2KM LMC5603C-SC-2KM LMC5603C-ST-5KM LMC5603C-SC-5KM LMC5603C-ST-40KM LMC5603C-SC-40KM Single Strand Fiber LMC5603C-10SC- 20KM LMC5603C-50SC- 20KM LMC5603C-10SC- 40KM LMC5603C-50SC- 40KM Description HDMCII 5-Port 10/100 TX Module HDMCII 4-Port 10/100 TX +1 Port SFP Module HDMCII 3-Port 10/100 TX +2 Port SFP Module HDMCII 3-Port 10/100 TX +1 PRT 850MMST Module HDMCII 3-Port 10/100 TX +1 PRT 850MMSC Module HDMCII 3-Port 10/100 TX +1 PRT 1300MMST Module HDMCII 3-Port 10/100 TX +1 PRT 1300MMSC Module HDMCII 3-Port + FX-SM1310/PLUS-ST HDMCII 3-Port + FX-SM1310/PLUS-SC HDMCII 3-Port + SSFX-SM1310-SC (1310xmt/1550rcv) HDMCII 3-Port + SSFX-SM1550-SC (1550xmt/1310rcv) HDMCII 3-Port + SSFX-SM1310/PLUS-SC (1310xmt/1550rcv) HDMCII 3-Port + SSFX-SM1550/PLUS-SC (1550xmt/1310rcv) LMC5605C 724-746-5500 blackbox.com Page 5

Chapter 1: Specifications 1. Specifications Industry Standards Ethernet Connections IEEE 802.3x Ethernet Standards IEEE 802.3u Auto Negotiation Standards 10/100 BaseT, Auto Negotiation, AutoCross, Flow Control, 1916 MTU, Full Line - Rate Forwarding Power Consumption TX/5: 0.19A @ 5V (typical) TX/4 + SFP: 0.57A @ 5V TX/3 + 2SFP: 0.65A @ 5V TX/3 + FX: 0.444A @ 5V Operating Power 2.5W Operating Temperature +32 F to +122 F (0 C to +50 C) Storage Temperature Humidity Dimensions -31 F to +158 F (-35 C to +70 C) 5 to 95% (non-condensing); 0 to 10,000 ft. altitude 4.19 x.78 x 2.75 (106.4 mm x 19.81mm x 69.85 mm) Page 6 724-746-5500 blackbox.com LMC5605C

2. Overview: About the HDMCII 10/100 TX Modules Chapter 2: Overview The HDMCII 10/100 TX Modules are 5-port Ethernet modules that allow the user to increase the port density and service area of Ethernet networks. The store and forward switch function allows the user to extend Ethernet service to locations a total of 100 meters from the Ethernet source. All RJ-45 ports Auto Negotiate 10/100BaseT, full/half duplex, and automatically configure for MDI or MDIX operation. Each port allows a maximum frame size of up to 1916 bytes, with support for Flow Control and priority queuing. Each SFP or fixed fiber port supports 100 Mbps FDX; the fiber is available in a variety of SM and MM types, including SSF. 2.1 Priority Queuing The HDMCII 10/100 TX Modules support two levels of priority queuing at the egress of every port. All frames with high priority will egress the port ahead of low priority frames at a 10:1 ratio. Priority is determined, first, through VLAN Tag priority. If no VLAN Tag is available then the DiffServ (ToS) bits are used. The VLAN Tag priority is based on a 3 bit PRI word where the base priority is set to 4. Values of 4 or greater have high priority. 2.2 Flow Control Flow Control is based on the outcome of the Auto Negotiate function. If Flow Control is enabled then a port will stop transmitting frames when a PAUSE frames is received. When the internal buffers become congested the unit will send PAUSE frames to all congested ports. Frames will be dropped if no internal buffer space is available at ingress. LMC5605C 724-746-5500 blackbox.com Page 7

Chapter 3: Install the HDMCII 10/100 TX Modules 3. Install the HDMCII 10/100 TX Modules The HDMCII 10/100 TX Module is a media converter module that provides 5- port 10/100 Auto Negotiating Ethernet ports. The module can be installed in any High-Density Media Converter System II chassis. 3.1 Managed Modules In order to manage HDMCII 10/100 TX Modules, an SNMP agent must be present in the chassis. To manage the module, first install the module into the chassis. After installing SNMP software, iview², port status per port can be monitored. There is no port configuration; the Graphical User Interface (GUI) provides LED status information only. SFPs with DDMI will not offer an SFP Table through iview². 3.2 Unmanaged Modules The HDMCII 10/100 TX Modules are unmanaged 5-port 10/100 modules; there are no DIP Switch settings to configure. If installed in an unmanaged chassis, the LEDs will indicate the status of each port. Page 8 724-746-5500 blackbox.com LMC5605C

Chapter 4: Operation 4. Operation 4.1 Port LEDs The ports on the HDMCII 10/100 TX Module include diagnostic LEDs that indicate unique information about the port functionality and status. 4.2 HDMCII 10/100 TX/5 For all units with 5 copper ports, the two LEDs associated with each twisted pair port are defined as follows: Port LED Name Color Function No link signal detected on copper port TX LNK/ACT Flash Copper port is receiving sync signal Activity is detected on the port Port is operating in half duplex FDX Flash Port is operating in full duplex Flashes when port is set to HDX and collisions occur LMC5605C 724-746-5500 blackbox.com Page 9

Chapter 4: Operation 4.3 HDMCII 10/100 TX/4 + SFP For all units with 4 copper ports, the two LEDs associated with each twisted pair port are defined as follows: Port LED Name Color Function No link signal detected on copper port LNK/ACT Copper port is receiving sync signal TX Flash Activity is detected on the port Port is operating in half duplex FDX Flash Port is operating in full duplex Flashes when port is set to HDX and collisions occur No SFP installed FX LNK/ACT Glows green when Link is established Flash Flashes with activity Page 10 724-746-5500 blackbox.com LMC5605C

Chapter 4: Operation 4.4 HDMCII 10/100 TX/3 + 2SFP For all units with 3 copper ports, the two LEDs associated with each twisted pair port are defined as follows: Port TX FX SFP A FX SFP B LED Name LNK/ACT FDX LNK/ACT LNK/ACT Color Flash Flash Flash Flash Function No link signal detected on copper port Copper port is receiving sync signal Activity is detected on the port Port is operating in half duplex Port is operating in full duplex Flashes when port is set to HDX and collisions occur No SFP installed Glows green when Link is established Flashes with activity No SFP installed Glows green when Link is established Flashes with activity LMC5605C 724-746-5500 blackbox.com Page 11

Chapter 4: Operation 4.5 HDMCII 10/100 TX/3 + FX For all units with 3 copper ports, the two LEDs associated with each twisted pair port are defined as follows: Port TX FX LED Name LNK/ACT FDX LNK/ACT Color Flash Flash Flash Function No link signal detected on copper port Copper port is receiving sync signal Activity is detected on the port Port is operating in half duplex Port is operating in full duplex Flashes when port is set to HDX and collisions occur No link Link at 100 Mbps Activity is detected on the fiber port Page 12 724-746-5500 blackbox.com LMC5605C

Chapter 5: Contacting Black Box 5. Contacting Black Box Black Box Customer Service Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) Free technical support, 24 hours a day, 7 days a week. Call: 724-746-5500 or Fax: 724-746-0746 Mail order: Black Box Corporation 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com LMC5605C 724-746-5500 blackbox.com Page 13

Chapter 6: Fiber Optic Cleaning Guidelines 6. Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1. Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier; low-quality components can cause many hard-todiagnose problems in an installation. 2. Dust caps are installed at Black Box to ensure factory-clean optical devices. These protective caps should not be removed until the moment of connecting the fiber cable to the device. If you need to disconnect the fiber device, reinstall the protective dust caps. 3. Store spare caps in a dust-free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics. 4. If you suspect that the optics have been contaminated, alternate between blasting with clean, dry, compressed air and flushing with methanol to remove particles of dirt. Page 14 724-746-5500 blackbox.com LMC5605C

7. Electrostatic Discharge Precautions Chapter 7: Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to any product, add-in modules or stand alone units, containing electronic components. Always observe the following precautions when installing or handling these kinds of products. 1. Do not remove unit from its protective packaging until ready to install. 2. Wear an ESD wrist grounding strap before handling any module or component. If the wrist strap is not available, maintain grounded contact with the system unit throughout any procedure requiring ESD protection. 3. Hold the units by the edges; do not touch the electronic components or gold connectors. 4. After removal, always place the boards on a grounded, static-free surface, ESD pad or in a proper ESD bag. Do not slide the modules or stand alone units over any surface. WARNING! Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage. Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices. LMC5605C 724-746-5500 blackbox.com Page 15

LMC5605C Rev. 1 52-80445BB-01 Rev. A1