The art of simplicity. sentron

Similar documents
Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Air Circuit Breakers. 1/2 Introduction

SENTRON 3VL Molded Case Circuit Breakers

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Air Circuit Breaker (ACB)

Energy Saving HRC Fuse-Links

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

SENTRON Switching and Protection Devices Air Circuit Breakers

Moulded Case Circuit Breakers

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

Video Door Phone Collection 2017

OMEGA Air Circuit Breakers

TeSys IEC Contactors and Overload Relays

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Description. Installation. Power supply

Section 4 Ground-Fault Protection Devices

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

SIRCO Load break switches for power distribution from 125 to 5000 A

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Switch Disconnectors, Main and EMERGENCY-STOP Switches

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

3 Pole Contactors with AC operating coils

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

Soft starter- ASAB 1

Appendix 08: Details of Location under Each Category

SENTRON. Protective devices Selectivity for 3VA molded case circuit breakers. Introduction. Selectivity - terms and definitions

ASCO 920 Remote Control (RC) Switches

4. CIRCUIT BREAKERS. Functional Emergency Switching

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

1492-SP Supplementary Protectors

SECTION SWITCHBOARDS

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

CANARA BANK NRI CELL, CIRCLE OFFICE 1ST FLOOR, RED CROSS BHAVAN SACHIVALAYA MARG BHUBANESWAR : ODISHA, INDIA E MAIL ID:

IZMX series Air Circuit Breakers with Power Xpert Releases PXR

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

920 Remote Control (RC) Switches

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

MV Network Switchgear, Protection and Control

Miniature Circuit-Breaker IEC Series 8562

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Applying branch circuit breakers and supplementary protectors in North America

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

RB60 RANGE. Miniature circuit breakers

AIR COOLED MODULAR RECTIFIER

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Intelligent Power Factor Controller with Automatic set-up. etacon Series. Automatic Power Factor Controller

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

MiCOM P521. Fast Feeder Differential Protection

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Applying branch circuit breakers and supplementary protectors in North America

IZMX Series Air Circuit Breakers. Small, flexible, efficient

ASCO SERIES 230 Automatic Transfer Switch

Motor protection relays

RATINGS AND SPECIFICATIONS

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

MPSC Microprocessor-based protection and metering devices for low voltage power circuit breakers. ABB Power Distribution

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

60103 Circuit Breaker

EMS CX 3 - State and control module for Latching relays and Contactors

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

SACE Emax 2 Specification guide

IEC Power Control Contactors and Contactor Assemblies

MINI-PS AC/10-15DC/8

Miniature Circuit Breakers for Railway Applications

Bulletin 1489 Circuit Breakers. Selection Guide

UL 489 DIN Rail Miniature Circuit Breakers

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

TeSys contactors From 115 to 2750 A

SENTRON ATC Automatic Transfer Control Device

Series 230 Automatic Transfer Switch

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

The right solution for every home

The Intelligent Simplicity. Sentron 3WL Air Circuit Breaker. Answers for industry.

UL 489 DIN Rail Miniature Circuit Breakers

SMART WIREFREE. Home Automation Solutions

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

The Leviton Load Center THE FUTURE MADE CURRENT

The Intelligent simplicity. sentron WL

Feeder protection relay SPAA 121 C. Product Guide

LE ELECTRONICS Pvt. Ltd.

MOTOR PROTECTION CIRCUIT BREAKERS

Transcription:

The art of simplicity Data Sheet sentron 3WT s

Sentron 3WT The Art of Simplicity. During the last decade, with the introduction of 3WN and 3WL Circuit Breakers, Siemens introduced a new perspective in the field of Switching technology and Intelligent communication. The standards of Performance, Reliability, and Safety were further raised through the Sentron series and offered an Art of Intelligent Simplicity. Siemens Sentron family of Air circuit breaker grows further and now offers an additional range of 3WT Circuit breakers for greater choice and optimized selection in LV power system. Sentron 3WT is available with Siemens hallmark of Performance, Reliability, Safety, Ease of operation and Maintenance, and accurate protections under the banner: Sentron 3WT The Art of Simplicity. 3WT is available from 630 A to 3200 Amp in two frame sizes with the following advantages: Safety Plus: High degree of protection IP 40. Interchangeable Line- Load terminals. Front cover can t be removed if the circuit breaker is in closed condition. SAFE OFF Suitable for isolation. Castell key can be removed only when contacts are separated. Locking of withdrawable circuit breaker against moving, as standard. Locking of the guide frame with the circuit breaker removed, as standard. Trip signalling switch for overload and short circuit tripping with mechanical closing lock out. Distinct Ready to Close interlocking is provided as inherent safety features. This ensures safe switching ON of ACB and eases the diagnosis. 3WT Conforms to isolation requirement as per IEC 60-947- 2. Easy Plus: Ease of Operation, Maintenance and Upgradation: Unambiguous ON- OFF indicator with auxiliary switch for signal. Click-fit front accessories e.g Shunt, Under Voltage, etc can be replaced without removing the breaker from the panel and needs no calibrations. High electrical life reduces frequency of replacement of contacts. Permits last minute up-gradation. e.g converting from Manual to Motorized or from fixed to draw-out. Built-in test features of the release permit testing of the breakers and trip circuitry without additional test kit. Contact erosion indicator for predictive maintenance. Compact and Power Saver: Continues rated low consumption accessories like shunt, Motor, Under Voltage bring down the cost and size of the control transformer. Low power loss per poles improves the inpanel rating of the circuit breaker without increasing the circuit breaker width. 630 Amp 3WT 630 Amp fixed version has 40 watt power loss and a width of 320 mm. 3WT conforms following standards: IEC 60947 2, IS 13947-2 VDE 0660 Part 101, GB 14048.2, Climate proof to IEC 60 068 2-30, Approval according to maritime classification on request. 2

3WT The Art of Simplicity - Secondary isolating contacts Mechanical reclosing lockout Closing Coil Ready to close interlock Shunt Release Microprocessor based trip unit U/V Release Racking window Motorised mechanism 3

Simplicity of Inspection and Operational Safety Front accessible secondary isolating contacts permit inspection and retrofitting of auxiliaries without removing the breaker from the guide frame Easily approachable protection C.Ts Fire retardant insulating material Insulating enclosure segregates phases completely and isolates the power contacts from the front accessible operating mechanism/auxiliaries/trip unit compartments Metallic guide rails hold the breaker in maintenance position for inspection and retrofitting of auxiliaries Contact erosion indicator No adjustments required after replacing power contacts Racking window blocks access to the racking mechanism. The window opens only when the OFF push button is kept depressed, preventing racking of the breaker in ON condition. Keyless Mechanical Interlocking Interlocking Mechanism Two or three breakers can be mechanically interlocked Ideal for auto change over systems Mechanical Cord The breakers can be mounted side by side or above each other 4

Easy Terminations: Simplified busbar and cable connections through different terminal orientation Front accessible terminals for panels without rear access Rear horizontal terminals for horizontal bus connections & bus couplers Rear vertical terminals for multiple cable terminations and vertical droppers Slot for Phase barrier to prevent arc propogation in the ACB in the event of line side fault Breakers terminals are generously designed for copper and Aluminum terminations. Easy Retrofit options: Ready to Fit Kit for replacing your old circuit breaker (3WE or any other make*) by 3WT without drilling a single additional hole in a existing panel to match the mounting or busbar terminations. * Conditions apply 5

Reliability Plus: Microprocessor Based Release for Ultra Accurate Protections: Electronic trip units The Microprocessor based releases which measures TRUE RMS current are provided with following standard features: Integrated Test Features: The test button test the healthiness of solid state trip units, trip solenoid and breaker mechanism with or without tripping of the circuit breaker. This eliminates external test unit to check the healthiness of the protection measuring system. Active LED to show healthiness of ETU: Correct operation of the electronic trip unit is indicated by the heartbeat of a green flashing LED. Rapid flashing of LED will indicate whenever load current exceeds the threshold value of overload protections. Fault Clarity and Fault History: The LEDs shows the reason for tripping of the breaker. Fault history is also recorded and can be recovered by QUERY button. Microprocessor Bypass circuit: If a microprocessor fault occur, the alarm will activate red LED MP. This alarm indicates that the overload protection functions are not currently active. However, with the internal bypass circuit, ETU guarantees protection against short-circuit. 6

Comprehensive Additional Functions for High Uptime: Comprehensive additional functions in accordance with the design of the electronic trip unit, e.g.: Measurement methods Vectorial summation formation with current transformer in neutral conductor The neutral conductor current is measured directly and is evaluated for neutral conductor overload protection. Short time-delay short-circuit release with I 2 t-dependent delay for improved discrimination to the downstream fuses The electronic trip unit determines the ground-fault current by means of vectorial summation of current in all three phases and the N-conductor current. LCD operating current display Ground-fault protection Description Ground-fault releases G sense fault currents that flow to ground and that can cause fire in the plant. Multiple circuitbreakers connected in series can have their delay times adjusted so as to provide time-graded discrimination. The reason for tripping is indicated by means of an LED when the query button is activated. Three-pole circuit-breakers, current transformers in the neutral conductor suitable for asymmetrical loading of the phases. Electronic trip unit version ETU5WT, ETU8WT 400.13 400.14 Current transformer T5 must be connected to auxiliary current connection For 4-pole circuit-breakers, the fourth current transformer for the N-conductor is installed internally. Module for mutual mechanical interlocking The module for mutual mechanical interlocking can be used for one or two 3WT circuit-breakers and can be adapted easily to the corresponding versions. The circuit-breakers can be mounted alongside each other or one above the other, whereby the spacing of the circuit-breakers is determined solely by the length of the Bowden cable. The Bowden cables are supplied in standard lengths of 2 m. Interlock signals are looped through via the Bowden cables. Interlocking is only effective in the connected position in the case of withdrawable circuit-breakers. The mechanical lifetime of the Bowden cables is 8000 operating cycles. The interlocking module is mounted on the right-hand side of the fixed-mounted circuit-breaker or the guide frame. 3WT circuit-breaker, 3-pole, with interlocking module and Bowden wire Interlocking module with Bowden wire The fixed-mounted and withdrawable circuit-breaker versions are fully compatible and can therefore be used in a mixed configuration in an installation. 7

Functional overview of the electronic trip unit system Function Basic functions Overload protection Inverse-time delayed Adjustment of the current setting I R from 40 % to 100 % I n overload release L Graduation 5 % for the phases Graduation freely programmable for the neutral conductor 1 ) Time-lag class t R = opening time at 6 I R, setting t R Thermal image Phase-failure sensitivity (reversible) Adjustment of the current setting I n Time-lag class t R of the neutral conductor as for the phases Short-circuit protection Short-time delayed Setting the operating current I sd short-circuit release S Setting the delay time t sd Instantaneous short-circuit release I With I 2 t sd-dependent delay, delay time t sd Setting the operating current I i Ground-fault protection Ground-fault release G 1 ) Setting the operating current I g Setting the delay time t g LCD display Operating current indication LED display Status indication Flashing LED when electronic trip unit activated Tripped indication L release S/I release S release I release N release G release Alarm indication T. U. ERROR Test Internal self-test and display via LED Connection of the test device to test connector X3 Basic configuration Signal by Ready-to-close Circuit-breaker can be safely closed signaling switch (1 NO) Tripped switch Latching; active after L, S, I, G 2 ) release with/without mechanical closing lockout 1) With 3-pole circuit-breakers a current transformer is required if there is asymmetrical loading of the phases. In the case of 4-pole circuit-breakers a current transformer in the neutral conductor is fitted internally in the circuitbreaker. 2) G release occurs with Trip setting on the electronic trip unit. 8

Electronic trip unit ETU2WT ETU8WT ETU5WT version ( 8th position of Order No.) 10 s 10 s 2 30 s 50 or 50 or 100 % 100 % 1.5 12 I R 1.25 12 I R 1.25 12 I R 0; 20 400 ms 0; 20 400 ms 20 400 ms 80 300 ms >15 I n >15 I n >1.5 12 I n and I i = with setting I i = then I cu = I cs = I cw (lowest value decisive) 0.2 0.6 I n 100 500 ms Function available as standard Function active when t d is set to 20 ms. 9

3WT Characteristics The characteristics show the behavior of the electronic trip unit when it is activated by a current that is already flowing before the tripping operation. If the overcurrent tripping occurs immediately after switch on and the electronic trip unit is yet to be activated, the opening time is extended, depending on the level of the overcurrent by approximately 3 to 10 ms. In order to determine the total break-times of the circuit-breakers, approximately 15 ms must be added to the opening times shown for the arcing time. Tripping characteristics L and S : S = definite-time delayed Tripping characteristics of electronic trip units version ETU2WT Tripping characteristics of electronic trip units version ETU8WT Key to illustrations above: Inverse-time delayed electronic trip unit L Short-time delayed short-circuit release S I R Current setting (adjustable) I sd Operating current (adjustable) I N Current setting (50 or 100 % I R) for the N conductor t sd Delay time (adjustable) t R Time-lag class (permanently set to 10 s) Tripping characteristics I Tripping characteristic G : definite-time delayed Tripping characteristics of electronic trip units versions ETU2WT and ETU8WT I n Transformer primary rated current Instantaneous short-circuit release I I i Operating current (permanently set) Tripping characteristics of electronic trip units version ETU8WT I n Transformer primary rated current Ground-fault release G I g Operating current (adjustable) Delay time (adjustable) t g 10

Technical Specifications that blends with Indian Environment: 3WT Technical Specification Sheet Basic Units 3WT Size I Size II Rating 3WT8 06 3WT8 08 3WT8 10 3WT8 12 3WT8 16 3WT8 20 3WT8 25 3WT8 32 Rated Current (In) 50/60 Hz at Main Conductors A 630 800 1000 1250 1600 2000 2500 3200 40 C ambient temperature N Conductor A 630 800 1000 1250 1600 2000 2500 3200 Rated operational voltage Ue 50/60 Hz, 3 Ph. V (AC) upto 440 V Rated impulse withstand Main conducting paths (kv) 8 voltage, Uimp Auxiliary Circuit (kv) 4 Utilization category as per IEC 947-1 & 2 B Rated short circuit making capacity Icm (peak) upto 440 V 110 143 Rated service short circuit breaking capacity, Ics (r.m.s) upto 440 V 50 65 (Ics = Icu) Rated short time withstand current, Icw. For 1 Sec 1 Sec Rating 50 60 at 50/60 Hz Permissible service temperature Operation C (-20 / 70 ) Power Loss at In Fixed- mounted 40 60 90 120 140 170 325 420 (with 3 phase symmetrical load) Withdrawable 80 130 205 255 310 310 535 760 Durability (Operating Cycles) Mechanical (with maintenance) 16000 12000 Mechanical (without Maintenance) 8000 6000 Electrical (without Maintenance) 5000 2000 Degree of Protection IP 40 Weight, 3/4 Pole ACB Fixed (kg) 34 / 47 36 / 49 57 / 70 61 / 74 Drawout (kg) 36 / 49 38 / 51 59 / 72 63 / 76 Guide Frame (kg) 22 / 27 33 / 28 35 / 46 37 / 48 Dimensions A (mm) 320/420 420 / 540 3 / 4 Pole B (mm) 470 470 C (mm) 330 330 For dimensional details and circuit diagrams please refer catalogue no. SGR- 11

Your Partners Sales Offices: Ahmedabad - 380009 1st Floor, Shanti Chamber Terapanth Marg, Opp. Dinesh Hall Near I.T. Cross Road, Navrangpura +91 79 27546803, 27546172 Fax +91 79 27546711 Bangalore - 560 001 No.49, Jyoti Mahal, First Floor St. Marks Road +91 80 22042000 Fax: +91 80 22224131 / 51120735 Chennai - 600034 4, Mahatma Gandhi Road +91 44 2833 4000 Fax +91 44 28334088 Coimbatore - 641018 7th Floor, East Wing, Global Towers 1057 Avinashi Road +91 422 2380908, 2380772 Fax +91 422 2380271 Kolkata - 700042 43 Shanti Palli, R B Connector Eastern Metropolitan Bypass +91 33 24449000, 24428641-47 Fax:+91 33 24449010 / 13 Mumbai - 400018 130, Pandurang Budhkar Marg, Worli +91 22 24987000-02 Fax: +91 22 24987312 New Delhi - 110002 4A, Ring Road, I.P. Estate +91 11 23455000-09 Fax +91 11 23455030 Pune - 411004 Vasant Vihar, 1205/2/6 Shirole Road Shivajinagar +91 20 25506000 Fax: +91 20 25506060 Secunderabad - 500025 9-1-87/119/2 1st Floor, St. John s Road +91 40 27702552, 27704544 Fax +91 40 27702951 Territory Managers : Aurangabad Mobile: 9822193204 E-mail: siemens_nsk@sancharnet.in Bhilai - 490 001 C/o. Mr. S. H. Siddiqui Sector -1, Street- 9, Quarter No.1A Mobile: 9826127525 E-mail: siemens_chg@sify.com Bhopal - 462 023 C/o. Mr. A.K. Sundrani, Sector - D, Plot No. B-204 Meenal Residency, J.K. Road +91 755 2688662 Mobile: 9425057945 E-mail: siemens@sancharnet.in Bhubaneswar - 751 003 Flat No. 4C, Aditya Palace 218/219, Paika Nagar +91 0661 2563124 Mobile : 9437013124 E-mail: angshumanrc@yahoo.com Chandigarh - 134113 House No.352, Sector 5, Panchkula, Haryana & Fax +91 0172-2585902 Mobile : 94171 21990 E-mail: siemenschd@satyam.net.in Cochin - 682016 Preethi Building, 1st Floor M.G.Road, Ernakulam +91 0484-2380201, 2380506 Fax +91 0484-2371564 E-mail: kumchn@satyammail.com Durgapur - 713 216 A-39, Moulana Azad Sarani 1st Floor, City Centre +91 0343-2546777 Mobile: 9832172046 E-mail: dgp_sldgp@sancharnet.in Guwahati - 781003 G1, Hill View Apartment Navagraha Path Chenikuthi Hill Side +91 0361-2663988 Mobile: 98640 37562 E-mail: konard@vsnl.net Hardwar - 249 407 758, 1 st Floor, Model Colony Awas Vikas, Jwalapur, Uttaranchal +91 01334 265491 Mobile: 9897070133 E-mail: siemens_hwd@datainfosys.net Indore - 452001 304, 18-19, Yash Tower Maha Durga Nagar, Janki Nagar Mobile: 9826641970 E-mail: siemens_indore@yahoo.com Jaipur - 302016 Flat No.104, Akshat Kailash Apartment Basant Marg, Bani Park, Rajasthan & Fax : +91 0141-2204910 Mobile: 9829244313 E-mail: siemens_jpr@dil.in Jallandhar - 144 004 46, 2 nd Floor, Saraswati Vihar Kapurthala Road, Punjab +91 0181 2259099 Mobile: 9815921211 E-mail: siemensjal@vsnl.net Jamshedpur - 831 005 1511, Kirthar Apartment, Vijaya Heritage Uliyan, Kadma +91 657 2311352 Mobile: 9835182772 E-mail: bapi_indranil@rediffmail.com / Siemens_jsr@yahoo.com Kanpur - 208001 Flat No.19-B, 4 th Floor, Prabhu Vatika 7/109, Swarup Nagar, U. P. /Fax +91 0512-2548765 Mobile: 9839102434 E-mail: siemens_knp@satyam.net.in Kolhapur - 416001 Plot No.35, Vasant Smruti, Shivaji Park +91 0231-2536626 Mobile: 9822848415 E-mail: siemenskpr@sancharnet.in Lucknow - 226001 47, HIG,1st Floor, Avas Vikas Colony Mail Avenue, U.P. +91 0522-2217421 Mobile: 9415012500 E-mail: siemens_lko@satyam.net.in Ludhiana - 141001 Flat No.5 (GF), HIG Flats, Opp. Milk Plant Bhai Randhir Singh Nagar, Ferozpur Road Punjab +91 0161-2457199 Mobile: 9417045273 E-mail: siemens_ldh@satyam.net.in Madurai - 625003 3/4, 1st Floor, Nehru Nagar 4th Street T.V.S Nagar +91 0452-2693705 Mobile: 9843269370 E-mail: srinivasan.veeraraghavan@siemens.com Nagpur - 440 015 Sai Sadan, Plot No.1 Near Mount Carmel School Ajani Square Mobile: 9850300524 E-mail: siemensnagpur@sify.com Nashik - Mobile: 9822193204 E-mail: siemens_nsk@sancharnet.in Rourkela - 769 004 T-15 Civil Town, +91 0661-2401724 Mobile: 9437041724 E-mail: gangulys_sl@yahoo.co.in Shaktinagar - 231 222 Room No. 7, Panchvati Guest House Kota Basti, Dist. Sonebhadra, U.P. +91 05446-233212, 232044 Mobile: 9415233345 E-mail: siemens_upeast@sify.com Vapi - 396191 B-603, Parasmani Apt. Opp. Post Office Besides Hanuman Temple +91 260 2462328 Mobile: 9825147957 E-mail: siemens_vapi@yahoo.com Vijayawada - 520010 G-2, Shreya Towers Moghalrajapuram Near Jammichettu Centre +91 0866-5529933 Mobile: 9849001842 E-mail: pramod.krishna@siemens.com Visakhapatnam - 530004 Flat No. 101, Shripal Towers Kiralampudi Layout Mobile: 9849077719 E-mail: siemensvizag@rediffmail.com Siemens Ltd. Automation and Drives Division LV Control & Distribution Products Thane Belapur Road Thane 400601 Fax : +91 22 27623729 e-mail : AD.CDPM@kwa2.co.in Siemens Ltd. SGR- Product development is a continuous process. Consequently, the data indicated in this Catalogue is subject to change without prior notice. For latest issue contact our Sales Offices.