RM4JA01F current measurement relay RM4-J - range ma V AC

Similar documents
RM4JA32MW current measurement relay RM4-J - range A V AC DC

RM4UA33M voltage measurement relay RM4-U - range V V AC

RM4JA31M current measurement relay RM4-J - range ma V AC

RM4TR31 three-phase network control relay RM4-T - range V

RM4TA32 three-phase network control relay RM4-T - range V

RM4LA32M liquid level control relay RM4-L V AC

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE9RA21MW7 off-delay timing relay s V AC -

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM35TF V AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM17UB3. Price* : USD

RM35LM33MW liquid level control relay RM35-L V AC/DC

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

RMCN22BD Analog Converter ma - for Zelio Analog

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RM35LM33MW liquid level control relay RM35-L V AC/DC

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RXM4AB3BD Miniature Plug-in relay - Zelio RXM 4 C/O 24 V DC 6 A with LED

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RXM4AB1MD Miniature Plug-in relay - Zelio RXM 4 C/O 220 V DC 6 A

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

TM3AI4 module TM3-4 analog inputs

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TM3DI16 module TM3-16 inputs

ABL1REM24062 regulated SMPS - single phase V input - 24 V output W

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

TM3TI4 module TM3-4 inputs temperature

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR2B121FU. Price* : USD with ladder programming. 80 maat 100 V (without extension)

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

ABL8WPS24200 regulated SMPS - 3-phase V AC - 24 V - 20 A

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

SR2B201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

ABL8RPS24030 regulated SMPS - 1 or 2-phase V - 24 V - 3 A

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

TM3TI8T module TM3-8 inputs temperature

TM3TM3 module TM3-2 temperature inputs and 1 analog output

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

Transcription:

Characteristics current measurement relay RM4-J - range 3..1000 ma - 110..130 V AC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in VA Measurement range Contacts type and composition Complementary Maximum switching voltage Dec 05, 2017 Zelio Control Industrial measurement and control relays Current measurement relay RM4J Overcurrent detection 1.9...3.3 VA AC 0.3...30 ma current AC 50/60 Hz 0.3...30 ma current DC 10...100 ma current AC 50/60 Hz 10...100 ma current DC 100...1000 ma current AC 50/60 Hz 100...1000 ma current DC 1 C/O 440 V AC [Us] rated supply voltage 110...130 V AC, 50/60 Hz +/- 5 % Control circuit voltage limits Output contacts Measuring cycle Internal input resistance Permissible continuous overload Permissible non repetitive overload Setting accuracy of the switching threshold Switching threshold drift Setting accuracy of time delay Hysteresis 0.85...1.1 Uc 1 C/O <= 80 ms 1 Ohm 10 Ohm 33 Ohm 0.05 A 0.15 A 1.5 A 5 A 0.2 A 0.5 A +/-5 % <= 0.06 % per degree centigrade depending permissible ambient air temperature <= 0.5 % within the supply voltage range (0.85...1.1 Un) 10 P 5...30 % adjustable of current threshold setting 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Marking CE : EMC 89/336/EEC CE : LVD 73/23/EEC Overvoltage category III conforming to IEC 60664-1 [Ui] rated insulation voltage Supply disconnection value Operating position Connections - terminals Tightening torque Mechanical durability [Ith] conventional free air thermal current 500 V conforming to IEC > 0.1 Uc Any position without derating Screw terminals 2 x 1.5 mm², flexible cable with cable end Screw terminals 2 x 2.5 mm², flexible cable without cable end 0.6...1.1 N.m 30000000 cycles 8 A [Ie] rated operational current 2 A at 24 V DC-13 70 C conforming to IEC 60947-5-1/1991 2 A at 24 V DC-13 70 C conforming to VDE 0660 3 A at 115 V AC-15 70 C conforming to IEC 60947-5-1/1991 3 A at 115 V AC-15 70 C conforming to VDE 0660 3 A at 24 V AC-15 70 C conforming to IEC 60947-5-1/1991 3 A at 24 V AC-15 70 C conforming to VDE 0660 3 A at 250 V AC-15 70 C conforming to IEC 60947-5-1/1991 3 A at 250 V AC-15 70 C conforming to VDE 0660 0.1 A at 250 V DC-13 70 C conforming to IEC 60947-5-1/1991 0.1 A at 250 V DC-13 70 C conforming to VDE 0660 0.3 A at 115 V DC-13 70 C conforming to IEC 60947-5-1/1991 0.3 A at 115 V DC-13 70 C conforming to VDE 0660 Switching capacity in ma Switching voltage Contacts material Number of cables 2 Width Height Depth Terminals description ISO n 1 Output relay state 9 mm pitches 2.5 Product weight 10 ma at 12 V 250 V AC 90/10 silver nickel contacts 23 mm 78 mm 80 mm (15-16-18)OC (A1-A2)CO (C-B1-B2-B3)CO Tripped if A measured > A set Tripped if V measured > V set 0.172 kg Environment Electromagnetic compatibility Electrostatic discharge - test level 6 kv, level 3 - contact discharge conforming to IEC 61000-4-2 Electrostatic discharge - test level 8 kv, level 3 - air discharge conforming to IEC 61000-4-2 Standards EN/IEC 60255-6 Product certifications CSA GL UL Ambient air temperature for storage -40...85 C Ambient air temperature for operation -20...65 C Environmental characteristic Relative humidity 15...85 % conforming to IEC 60721-3-3 3K3 Shock resistance 15 gn for 11 ms conforming to IEC 60255-21-1 IP degree of protection IP20 (terminals) conforming to IEC 60529 IP50 (casing) conforming to IEC 60529 Pollution degree 3 conforming to IEC 60664-1 Dielectric test voltage Non-dissipating shock wave 2.5 kv 4.8 kv Resistance to electrostatic discharge 6 kv contact conforming to IEC 61000-4-2 level 3 8 kv air conforming to IEC 61000-4-2 level 3 Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3 level 3 2

Resistance to fast transients 2 kv conforming to IEC 61000-4-4 level 3 Protection against electric shocks 2 kv : level 3 conforming to IEC 61000-4-5 Disturbance radiated/conducted CISPR 11 group 1 - class A CISPR 22 - class A Contractual warranty Warranty period 18 months 3

Dimensions Drawings Current Measurement Relays Dimensions 4

Mounting and Clearance Current Measurement Relays Rail mounting Screw fixing 5

Connections and Schema Current Measurement Relays RM4JA01 Wiring Diagram A1-A2 Supply voltage B1, B2, B3, Currents C to be measured (see table below) Connection and current values to be measured B1-C B2-C B3-C 3 30 ma 10 100 ma 0.1 1 A RM4JA31 Wiring Diagram A1-A2 Supply voltage B1, B2, B3, Currents C to be measured (see table below) Connection and current values to be measured B1-C B2-C B3-C 3 30 ma 10 100 ma 0.1 1 A RM4JA32 Wiring Diagram A1-A2 Supply voltage B1, B2, B3, Currents C to be measured (see table below) Connection and current values to be measured B1-C B2-C B3-C 0.3 1.5 A 1 5 A 3 15 A 6

Performance Curves Electrical Durability and Load Limit Curves AC Load Curve 1: Electrical durability of contacts on resistive load in millions of operating cycles X Current broken in A Y Millions of operating cycles Curve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1) X Power factor on breaking (cos φ) Y Reduction factor K DC Load Load limit curve X Current in A Y Voltage in V 1 L/R = 20 ms 2 L/R with load protection diode 3 Resistive load 7

Technical Description Function Diagram Overcurrent Detection Function > Legend t Time delay U A1-A2 Supply voltage IS1 Setting current threshold IS2 Current measured 15-18, 15-16; 25-28, 25-26 Output relays connections Relay status: black color = energized. 8