RocketStor 6328 Thunderbolt 2 RAID Host Adapters User s Guide for Mac

Similar documents
NA762TB High-Performance Thunderbolt Storage User s Guide V1.00 Mar. 9, 2014

RocketRAID 644L / 642L

RocketRAID For Mac User s Guide. SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA. Revision: 1.00 Jun. 26, 2013 HighPoint Technologies, Inc.

SSD7110 Hybrid Connectivity M.2 + SAS/SATA Ports, All-in one RAID Controller. User Guide V1.01

RocketU 1144CM Host Controller

RocketU 1144BM Host Controller

RocketStor 6314A User Manual

rdrive 6114VM User Manual 12/6/17 Revision HighPoint Technologies, Inc.

RocketStor 6674T. User Manual. November 14 th, 2017 Revision HighPoint Technologies, Inc.

G-SPEED Product Guide

rdrive 6628AW User Manual 1/17/18 Revision HighPoint Technologies, Inc.

rdrive 6114VW User Manual 12/6/17 Revision HighPoint Technologies, Inc.

RocketStor 6114V. User Manual. May 2, 2017 Revision 1.00 HighPoint Technologies, Inc.

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

RocketRAID 3600 Series

RocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. User s Guide v1.0

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

MAXPower esata 6G-4e PCIe 2.0 Controller Card

G-RAID 2 Installation Guide

RocketRAID 600L. User s Guide. SATA 6Gb/s PCI-Express 2.0 RAID Host Adapters. Revision: 1.0 Nov. 19, 2012 HighPoint Technologies, Inc.

FIVE-BAY RAID SYSTEM FOR 3.5 SATA HARD-DISK DRIVES

RocketRAID 2720C2. User Manual V1.00

The Industry s First Thunderbolt 2 Hardware RAID Adapter

Configuration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems

The Industry s First Thunderbolt 2 Hardware RAID Adapter

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

RocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. Quick Installation Guide v1.0

SSD Bay U.2 NVMe RAID Enclosure. User Guide V1.00

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

Product Release Notes

Taurus Mini Super-S LCM

RocketRAID Series Data RAID Set Up Guide

Introduction...1. Package Contents... 1 Product Features... 1 Specifications Product Schematic...2. HDD Installation...3

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

RocketRAID esata For Mac HighPoint Technologies, Inc.

GT 062 3TB Quickstart Addendum

AMD RAID Installation Guide

RocketRAID 231x/230x SATAII Host Adapter

RocketRAID 2700 Series

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

TOWERSTOR TS25CT. QUICK INSTALLATION GUIDE v1.0

RocketRAID 2700 Series

RocketRAID 2760A. 6Gb/s SAS/SATA Host Adapter. Quick Instal l ation Guide v1.1

First Edition, July 2011

RocketRAID 231x SATAII Host Adapter

Managing Storage Adapters

RocketRAID mini-sas 6G HBA Series Data RAID. Installation Guide

NT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1

XL-RAID-213SA User Manual

Drobo 5D3 User Guide

1 Drobo 8D User Guide Before You Begin Product Features at a Glance Checking Box Contents... 9

RocketRAID esata 3G HBA Series Data RAID Installation. Guide

RocketRAID Intelli-VRM (Intelligent Virtual RAID Management) Early Warning System and Virtual System Rescue

RocketStor Dual-Bay Thunderbolt TM 10Gb/s Storage Dock

RocketRAID 272x/271x Host Adapter

Lenovo RAID Introduction Reference Information

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2

SSD7120. NVMe U.2 RAID Controller. User Guide V1.00

Chapter 2 Using WebBIOS This chapter explains the WebBIOS setup procedures. WebBIOS is a basic utility to set up and manage the array controller.

RocketRAID 464. User, s Manual. Revision: 1.0 Date: Jun HighPoint Technologies, Inc.

USB 3.1 Type-C Gen 2 Dual-Bay External SATA SSD Enclosure Model

Addonics. 4-Port SATA II PCI RAID5/JBOD Controller Card (ADSA4R5) User s Guide Revision 1.0 T E C H N O L O G I E S

RocketRAID 2322 SATAII Host Adapter

USB 3.1 Type-C Gen 2 Dual-Bay External M.2 NGFF SATA Enclosure Model

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

SmartGUI Configuration Guide. Revision V1.40. February

SSD7101A-1. 4x M.2 Port to PCIe 3.0 x16 NVMe RAID Controller. User Guide V1.00

Addonics. 4X SATA Multilane PCI/PCI-X RAID5 Controller Card (ADS3GX4R5-ML) User s Guide Revision 1.1 T E C H N O L O G I E S

SOHOTANK ST4-TB User Manual

Dell PowerVault DL Backup to Disk Appliance and. Storage Provisioning Option

RocketRAID esata 3G HBA Series Data Single

AMD RAID Installation Guide

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3

InfoSafe esata/usb 2.0 Dual 3.5 SATA Drive Enclosure with RAID

User Guide External Port Multiplier Ultra (AD5EHPMEU3)

SOFTRAID XT. User Guide. an Other World Computing brand

Taurus S2. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English )

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SATA Hard Drive Enclosure

Thunderbolt TM LTO. mtape

3. Specifications I Features System Requirements Creating A New Partition / Formatting The Hard Drive RAID Mode Selection...

Mini-EPICa USB 3.0-to-SATA II RAID SUBSYSTEM

RAID Rack (RR2035RPHMS)

Serial ATA PCI RAID Quick Installation Guide

Using GIGABYTE Notebook for the First Time

RAIDTech USER S MANUAL. Revised October 3, Features

RocketRAID esata 6G HBA Series Boot Single Installation. Guide.

Taurus Super-S Combo

RAID User Guide. Edition. Trademarks V1.0 P/N: U25-A2-0E

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

RAID EzAssist Configuration Utility User Reference Guide

User Guide 1U RAID Rack with esata /U3 /FW800 (R1ESU3F)

Configuring Storage Profiles

User Guide 5-Port HPM-XU (AD5HPMREU)

Technical Guide Network Video Recorder Enterprise Edition Maintenance Guide

AMD RAID Installation Guide

SOFTRAID FOR THUNDERBAY. Quick Start Guide

NAS System. User s Manual. Revision 1.0

Transcription:

RocketStor 6328 Thunderbolt 2 RAID Host Adapters User s Guide for Mac Revision: 1.00 Mar. 12, 2014 HighPoint Technologies, Inc. 1

Table of Contents 1. HighPoint RocketStor 6328.3 2. System Requirement 3 3. What s in the box 4 4. RocketStor 6328(RS6328) Overview 4 4.1 RS6328 Specification 4 4.2 RS6328 Hardware 4 5. RS6328 Audible Alarm 5 6. Setup RS6328 5 6.1 Storage Enclosure Preparation 5 6.2 Connecting the RocketStor 6328 6 6.3 Driver and WebGUI Software installation 7 7. Configuring Storage RAID Arrays 8 7.1 Configuring RAID Arrays 8 7.2 Using the RAID disk with Mac OS X. 11 8. Deleting RAID Storage 13 9. RAID Disk Failure Recovery 14 10. Expanding RAID Storage Capacity 15 11. Technical Support 15 12. LIMITED WARRANTY 16 APPENDIX A - Using the WebGUI (full guide) 17 1. Running the HighPoint Web RAID Management software (WebGUI) 17 2. Web RAID Management Software - Global View..18 3. Web RAID Management Software - Physical 19 3.1 Physical - Controller.. 19 3.2 Physical - Devices. 20 3.3 Physical - Rescan.. 20 4. Web RAID Management Software - Logical.21 4.1 Logical - Create Array 22 4.2 Logical - Spare Pool 27 4.3 Logical Logical Device 28 4.4 Logical - Rescan. 28 4.5 Logical - Beeper Mute.... 28 5. Web RAID Management Software - Setting.. 29 5.1 Setting - System 29 5.2 Setting Email 31 6. Web RAID Management Software - Event. 32 7. Web RAID Management Software - SHI (Storage Health Inspector).. 33 8. Web RAID Management Software - Recover 36 APPENDIX B - Web RAID Management ICON Definition List 37 APPENDIX C - RAID Technology Explanation 39 APPENDIX D - Thunderbolt Daisy Chain configuration 40 2

1. HighPoint RocketStor 6328 The RocketStor 6238 is set to revolutionize the compact desktop and portable workstation market; no other Thunderbolt connectivity Adapter packs so much power and versatility into such a tiny package! The RocketStor 6328 delivers true, 20Gb/s bi-directional transfer bandwidth for any Mac or Windows PC platform with Thunderbolt capability. Key features Dual 20Gb/s Thunderbolt Ports 8x 6Gb/s SAS/SATA ports Hardware RAID 0,1,5,6,10,50 and JBOD 2. System Requirement A. Apple Mac or PC System with Thunderbolt support. B. Operating system: Mac OS X 10.9 or higher Windows 7, Window 8 or Windows 8.1 C. Storage Enclosure with Mini-SAS / esata Interface (Mini-SAS) (esata) D. External Mini-SAS cable options: HighPoint External Mini-SAS to External Mini-SAS cable (P/N: Ext-MS-1MMS) HighPoint External Mini-SAS to 4x esata cable (P/N: Ext-MS-1MEJ) 3

3. What s in the box RocketStor 6328 Power Adapter Power Cord Quick Installation Guide Software CD (includes Driver and WebGUI) 4. RocketStor 6328(RS6328) Overview 4.1 RS6328 Specification Host Interface/Ports Data Transfer Rate Device Ports Devices Interface RAID Levels RAID Suite Warranty ROHS Compliant Dual Thunderbolt 2 ports 20Gbps Bi-directional Dual External Mini-SAS ports (SFF-8088) Mini-SAS, esata (Port Multiplier) (cable sold separately) Integrated Hardware RAID 0, 1, 5, 6, 10, 50 & JBOD User friendly Browser-based Management Interface Limited Warranty period (parts): 2 years Limited Warranty period (Labor): 2 years Return For Repair or Replacement Only Yes 4.2 RS6328 Hardware Front side: 4

Back side: 5. RS6328 Audible Alarm The RS6328 has an internal Alarm buzzer. The Alarm buzzer is for HDD failure (offline) status notification and it will emit a high pitch continuous sound. This alarm will sound when a disk failure occurs or a disk or an array is removed without using the unplug feature in the WebGUI. When the sound is triggered, follow the steps below to check the HDD status and mute the alarm: a. Open the WebGUI and switch to the logical tab. The alarm can be stopped using the WebGUI s Mute button, or the Rescan function found under the Physical or Logical tabs. b. Check the physical device status if there are any disabled drives. c. Locate the disk module number. d. If the RAID is in critical status, please follow Chapter 8 RAID Disk Failure Recovery to recover the RAID disk e. For other RAID status, please refer p.14 for RAID recovery 6. Setting up the RocketStor 6328 6.1 Storage Enclosure Preparation RS6328 support two types of storage enclosure: External Mini-SAS and External SATA (esata). Each type of enclosure requires a specific type of cable. HighPoint cable options: EXT-MS-1MMS External Mini-SAS to External Mini-SAS (SFF-8088 to SFF-8088) EXT-MS-1MEJ External Mini-SAS to External SATA (SFF-8088 to 4x esata) 5

The supported enclosure interface: (Mini-SAS) (esata) RocketStor 6328 connection diagram: 6.2 Connecting the RocketStor 6328 (RS6328) Steps: a. Connect the RS6328 to the storage enclosure using an industry standard Mini-SAS cable. Power on the storage enclosure. b. Connect the Power Adapter to the RS6328. c. Connect the RS6328 to the host system using a Thunderbolt cable. 6

6.3 Driver and WebGUI Software installation 1) Driver Installation: Mac OS X a. Please visit http://www.hptmac.com/series_rs6328-resources.php for the latest driver package. Unzip the package. b. Double-click the uninstall.command script file to uninstall the currently installed driver. c. Double-click the HighPointIOP.mpkg icon to install the driver package. You will be asked to input the administrator s password in order to complete this. Once complete, you will be asked to reboot the system. Confirm the prompt to proceed. d. Verifying Driver Installation: Mac OS X e. After the driver has been installed and the system rebooted, verify the RS6328 device status using the OS X System Information pane. To verify the RS6328 driver status, Click the Apple icon on top left of the screen, and select About This Mac, and then select More Info. Next, select System Report, and click PCI Cards on left side of the System Information pane. The Driver Installed entry for controller pci1103, 6328 should be Yes 2) RAID Management software installation. In order to configure and manage the HighPoint RAID array, you will need to install the Web RAID Management software (also known as the WebGUI). a. Download and install the RAID Management software from the RS6328 product page: http://www.hptmac.com/series_rs6328-resources.php b. Unzip the package and double-click the HighPoint WebGUI icon to install the WebGUI. You ll be asked to input the system administrator s password to complete installation. c. Running the WebGUI After installation is complete, a WebGUI icon will be displayed on the desktop. 7

d. Double-click this icon to open the WebGUI. The system s default web browser will open a login page. To login, use the default user name: RAID and password: hpt. Warning: Using the WebGUI to create RAID arrays will destroy all pre- existing data on the selected disks. Make sure to backup any important data before using these disks to create arrays. 7. Configuring Storage RAID Arrays 7.1 Configuring RAID Arrays The RS6328 supports multiple RAID levels. The steps below describe how to quickly configure a RAID5 array with 8-bay (8-disk) storage enclosures. Step 1. Verify the physical device status. Click the Physical tab to make sure all of the HDD s are detected. Each drive will be designated as Device 1- N, where N refers to the disk module number. Click the device icon; it will display detailed information about the selected device. If any of the disks are not detected, check the corresponding disk module and make sure the drive is securely installed (see page 6 for more information). 8

Step 2. Verify the Logical Device status. Click the Logical tab to check if any of the disks were previously part of another RAID array. If a RAID configuration is reported, click on Maintenance, displayed toward the right of the Status column and delete the array. Make sure to back up any important data before deleting the array. Step 3. Creating a RAID Array. The following procedure demonstrates how to configure a RAID5 array. A RAID5 array s usable capacity is calculated using the following formula: N-1, multiplied by the capacity of the smallest disk (where N refer to the total number of disks). For more detailed instructions, see section 4.1 Logical: Create Array, on page 20. Note: We recommend using identical hard disk when creating a RAID array. In addition, only use enterprise class RAID edition hard drives. Follow the steps below to create a RAID 5 Array. a. Click the Create Array button on the left panel. b. Select the Array Type (RAID level): RAID 5 c. Select the Initialization Method: Foreground Note: For RAID5, only foreground or background initialization is recommended. The initialization time is dependent on array capacity. The initialization process will zero out all disks so a correct parity can be generated during disk writes. Correct, consistent parity information is essential for the integrity of data when rebuilding RAID 5 arrays. d. Select the Available Disks: Click the Select all button. 9

e. Click the Create button to create the array. f. The following diagram displays RAID5 foreground initialization in progress. 10

g. After the array has been created, it will be displayed under the Logical tab. 7.2 Using the RAID disk with Mac OS X. A newly created RAID Array will be recognized as an empty disk. OS X must initialize it before it can be used. a. Initializing the RAID disk. After a RAID array has been created, OS X will display a pop-up window with options to initialize, Ignore or Eject. Click Initialize to open Disk Utility. 11

b. Erase the Disk Select the RAID volume, and select the Erase tab. Enter a name in the Name: field, and click the Erase button towards the bottom right-hand corner to format the array. Once complete, the RAID array will be ready for use, and will be mounted on the desktop. After the RAID disk is erased, the RAID5 disk volume icon will be found on the desktop and finder as a new disk volume. c. Ejecting the RAID array To eject the RAID array using Mac OS X, select Go from the Desktop, and select Computer. Click on the RAID array (it will be displayed using the name you selected on step 2), and click on File. Select Eject from the drop-down menu to eject the RAID array. Note: The RS6328 supports Thunderbolt power management. While the RS6328 is connected to the host system using the Thunderbolt cable, shutting down the host will automatically power down the RS6328 12

8. Deleting RAID Storage To delete a RAID array: a. Log-in to the WebGUI. b. Switch to the Logical tab. c. Locate the RAID array that you wish to delete. d. Click the Maintenance link to the right of the RAID array. e. Click the Delete button from the Array Maintenance pop up window. f. Confirm the deletion by click OK button. Note: All data on the selected RAID array will be deleted after you confirm this selection. 13

9. RAID Disk Failure Recovery The RS6328 continually monitors the health of each of the disk drives. In the event of a disk failure, an audible alarm will sound. The WebGUI will also report the failed drive and its physical position. NOTE: For redundant RAID arrays (RAID 1, 5, 6, 10 or 50), a drive failure does not result in data loss. However, the array is now in an unprotected state and the failed drive should be replaced as soon as possible to avoid data loss. NOTE: If the storage was configured in RS6328 RAID 6 mode, up to two drives can fail with no loss of data. Replace any failed drive as soon as possible. Follow the steps below to identify and replace a failed drive. a. Launch the WebGUI b. Mute the alarm with the Beeper Mute button. c. The WebGUI will display information like that shown below. An exclamation mark on the RAID array icon indicates that the Status of the array is Critical. The lower portion of the GUI indicates which drive in which disk unit has failed. Note: In this example drive 4 of the RAID 5 Array of has failed. d. Unlock the failed drive s disk module of the storage enclosure and remove the failed drive by gently sliding the drive module out of the enclosure. WARNING: Make absolutely sure that you remove the failed drive indicated by the GUI. Reinstall the disk module immediately if you remove the wrong disk module. 14

e. Replace the failed drive with a new disk module and secure in place. Once the drive has spin up to speed, the WebGUI will indicate that the array is rebuilding (The Status shows Rebuilding and the percentage complete) as shown below. The rebuild time is approximately 2 hours per TB. f. Once the rebuild is complete, the RAID array will return to the Normal status. Your data is now secure. 10. Expanding RAID Storage Capacity Note: Mac OS X cannot support partition expansion DO NOT attempt to use the WebGUI s OCE or ORLM functions with a Mac system. To Expand RAID storage capacity: a. Back up all original data to a separate storage device. b. Delete the current RAID array c. Create a new array using the original and added disks. d. Restore the data from the backup source to the new array. 11. Technical Support If you encounter any problems while utilizing the HighPoint RocketStor Thunderbolt Series product, or have any questions about this or any other HighPoint Technologies, Inc. product, feel free to contact our Customer Support Department. Web Support: http://www.highpoint-tech.com/websupport/ Thunderbolt Support: Phone: (408)240-6108 Skype: HighPoint.Thunderbolt 15

12. LIMITED WARRANTY HighPoint warrants your Product against any defect in material and workmanship, under normal use, for the designated warranty period. If the Product should become defective within the warranty period, HighPoint will at its discretion, repair or replace the Product. Repair or replacement parts or Products will be furnished on an exchange basis and will be either new or reconditioned. All replaced parts or Products shall become the Property of HighPoint. This warranty shall not apply if the Product has been damaged by accident, misuse, abuse or as a result of unauthorized service or parts. Warranty service is available to the purchaser by obtaining a Return Material Authorization number (RMA) and by delivering the Product during the warranty period to an authorized HighPoint service facility or to HighPoint. The purchaser shall bear all shipping, packing and insurance costs and all other costs, excluding parts and labor, necessary to effectuate repair, replacement or refund under this warranty. All returned products must be shipped to HighPoint in the original shipping container. For more information on how to obtain warranty service, an RMA number or to acquire shipping materials, contact HighPoint Technical Support. The support information is listed on Chapter 11 section. IN THE EVENT A PRODUCT BECOMES DEFECTIVE DURING THE WARRANTY PERIOD, THE PURCHASER S EXCLUSIVE REMEDY SHALL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE. INCIDENTAL OR CONSEPROUENTAL DAMAGES, INCLUDING WITHOUT LIMITATION LOSS OF DATA, ARISING FROM BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ARE NOT THE RESPONSIBILITY OF GTECH AND, TO THE EXTENT PERMITTED BY LAW, ARE HEREBY EXCLUDED BOTH FOR PROPERTY DAMAGE, AND TO THE EXTENT NOT UNCONSCIONABLE, FOR PERSONAL INJURY DAMAGE 16

APPENDIX A - Using the WebGUI (full guide) HighPoint s web-based RAID Management Software (also known as the WebGUI) is used to monitor and configure hard disks and RAID arrays attached to the HighPoint RocketStor adapter. 1. Running the HighPoint Web RAID Management software (WebGUI) After downloading and installing the WebGUI, open the WebGUI by double-clicking the icon found on the desktop: Login to the WebGUI and configure the RAID arrays. Use the default user name: RAID and password: hpt to login Remote Login Users connected to a local network can remotely access the WebGUI through the IP address the machine is located on. Open a terminal and type in the following command: ifconfig Once the IP address is obtained users can remotely access the machine by typing in the following address: http://ip Address:7402 17

2. Web RAID Management Software - Global View A Controller(0): Drop-down menu that displays the controller that is currently being managed. B Host Adapter Model: Name of the RAID controller C Enclosure Count: Total number of HighPoint Rocket EJ (Port Multiplier) devices connected. It should be always 0 D Physical Drive: Total physical drives detected by this RAID controller E Legacy Disk: Total physical drives which has partition information created detected by this RAID controller F RAID Count Total RAID array count has been detected by this RAID controller G Total Capacity: Total capacity of all detected HDD s H Configured Capacity: Total GB of capacity configured for in Logical devices I Free Capacity: Total GB of capacity that is free for use in creating a JBOD or RAID array 18

3. Web RAID Management Software - Physical 3.1 Physical - Controller A. Controller Information It lists the following controller information Model Name: RAID controller model number BIOS Version: RAID controller BIOS version Vendor: Vendor Name PCI Bus Number: PCI slot information PCI Device Number: PCI device number PCI Func Number: PCI function number B. Extended Information It lists other controller information such as processor type, temperatures, voltage, SDRAM, Battery, Firmware version, and SAS address. C. Update Firmware Controller BIOS/Firmware can be update from Physical page. Browse for BIOS image and click the Submit button. 19

3.2 Physical - Devices A. Physical Device Information: It lists devices attached to this controller. Information includes disk model name and capacity. B. By clicking device icon, it displays detail device properties Unplug: Powers off the device or RAID array and allow you to remove the device Model: Device model information Revision: Firmware revision Location: Location number of the device on the RAID controller Max Free: Max free space for creating a single disk JBOD or to be part of a RAID array Status: Device status is Legacy or Normal Serial Number: Serial Number of device Capacity: Total capacity of the device Read Ahead: Caching mode to improve Read performance Write Cache: Caching mode to improve Write performance NCQ: Native Command Queuing, I/O commands that are in a queue are re-ordered for better efficiency Identify LED: A blinking cursor to identify the location of a HDD 3.3 Physical - Rescan The item will rescan the controller to detect devices. 20

4. Web RAID Management Software - Logical A. Logical Device Information: It is the logical disk that is connected to the RAID controller and has already been reported to the operating system. Example: Mac OSX Disk Utility B. Physical Device Information: The physical disk attached to the RAID controller. 21

4.1 Logical - Create Array To create an array, users need to provide information to tell utility how to construct this array. This section gives a detail description. The following diagram shows the creation page. A. Array Type Choose the RAID type to create. The HighPoint s RAID controller supports RAID 0, 1, 5, 6, 10, 50 & JBOD. 22

B. Array Name Enter the name for the RAID array. C. Initialization Method Array initialization cleans up each disk to ensure no invalid data exists once the array is in use. This is essential for arrays with parity information (redundant RAID arrays such as RAID 1, 5, 6, 10, 50). When an array is rebuilding, valid parity information is required in order to reconstruct the correct data. There are four initialization options to choose from: 1. Keep Old Data: This is the default option when creating a RAID array. a. This option leaves existing data intact. b. This option does not initialize the array disk. You can use this option when creating RAID arrays with new hard disks (initialization is not generally necessary for new drives, as they contain no data). c. In some cases, this option can be used to recover disabled RAID arrays. 2. Quick Init: The RAID array will be immediately accessible. a. This option will delete all content on the disks. b. This option will not perform disk array initialization. When new HDD s are used this option can be ignored since there is no data on the hard disk. 3. Foreground: The RAID array is not accessible until initialization is completed. a. This option will delete all content on the disks. b. The logical disks will not be reported to the operating system until initialization is complete. This method is faster than Background, and requires far less time to complete. 4. Background: The RAID array is accessible while disk initialization is being performed. a. This option will delete all content on the disks. b. This method will slow the initialization process, but allows the array to be utilized immediately 23

D. Cache Policy Two options are available when creating redundant RAID arrays (1, 5, 6, 10, 50). 1. Write Back Provides higher write performance for redundant RAID arrays. Data is at risk when there is a power failure, system kernel panic and/or the system is not responsive. 2. Write Through Provides superior data protection when there is a power failure. Data is written directly to disk. E. Block Size Block sizes are adjustable from 16K through 1024K, default is 64K F. Number of RAID5 member disks This option is related to creating a RAID 50 array. G. Select All User can select how many disks to construct the array or click this select all to use all HDDs for the array creation. H. Capacity This allows users to define how much disk capacity will be used. If maximum is chosen, then it means use all calculated available disk space. 24

After the array has been created, it will be displayed under Logical Device Information (Below section 4.3). The following information is displayed for each logical device: Name: Type: Capacity: Cache Policy: Block Size: Sector Size: OS Name: Status: Default name of the RAID array Type of RAID array Total capacity of the RAID array Redundant RAID array options for performance or protection RAID array block size RAID array sector size Name of HDD seen in the OS Status of RAID array. Other option include (Normal, Critical, Disable, Rebuilding, Verifying) Array Maintenance: Maintenance provides a selection of general maintenance features and options for the selected array: 1. Diagram 1: Array is in Normal Status 25

2. Diagram 2: Array is in Critical status The arrays current status and RAID level determine which options and features are provided by Maintenance: 1. Delete : Delete the selected RAID array 2. Unplug : Power off the RAID array and remove it. Without using this feature, removing any disk member will trigger the alarm. 3. Verify : This option is only available when RAID is in Normal status. 4. Add : This option is only available when RAID is in Critical status. Click the add disk button to add a new disk in. The following diagram shows how to add a free disk to join the critical array rebuilding. 26

5. Rebuild: Add a disk and rebuild a critical RAID array to normal. The following diagram shows rebuilding array in processing. 6. Change cache Policy: Toggle Between Write Through and Write Back Write Through: Lower write performance because data is written directly to HDD. Data cannot be lost due to power failure or some other circumstance. Write Back: Higher write performance but chances of data lose are greater since data still resides in cache 7. Rename: Rename the array other than the default 4.2 Logical - Spare Pool When creating redundant RAID arrays (1, 5, 6, 10 or 50) a Spare HDD can be configured to automatically help rebuild a degraded redundant RAID. Users can assign any free storage into spare pool. And any disk is in spare pool can be removed as well. The following diagrams show how to operate spare pool. 27

4.3 Logical Logical Device Displays logical devices hosted by the RAID controller. 4.4 Logical - Rescan When hot-plugging a single device or RAID array, the Rescan button prompts the RAID controller to scan for device changes. 4.5 Logical - Beeper Mute This will temporarily disable the internal speaker on the RAID controller. 28

5. Web RAID Management Software - Setting This tab displays various controller settings and options: 5.1 Setting - System A. Enable auto rebuild: If enabled, any new disk attached to the RAID controller will be used to rebuild the critical RAID array. B. Enable Continue Rebuilding on error: Note: The new disk needs to be equal to or larger than the minimum capacity among the remaining disk members of the array. Enabled by default. If disabled, the WebGUI will ignore bad sectors/read failures and allow the rebuild process to continue. Warning: this option should only be enabled in the case of an emergency data inconsistency or data loss may result. Review the Event Log before enabling this option, and check for HDD bad sector events. If bad sectors are found, we recommend first contacting the HDD manufacturer, then technical support, for further advice. C. Enable audible alarm: When a disk goes off-line the beeper on the RAID controller will sound. D. Set Spindown Idle Disk (Minutes): E. Restrict to localhost access: Hard drives can be instructed to spin down when there is no disk activity for a set period of time. You are free to specify the interval from 10 to 240 minutes. This option is used to restrict WebGUI access to the local system and not allowing remote access. F. Set Rebuild Priority: When rebuilding a critical RAID array, there are five rebuilding options to choose from. Each rebuild priority will affect the rebuild completion time. 29

Lowest Lowest Priority when rebuilding arrays. System resources will be assigned to all other tasks first. Low Low Priority. Most of the system s tasks have priority over the rebuild procedure. Medium Medium Priority is the default option system resources are equally distributed between the rebuild procedure and other system tasks. High High Priority the majority of available system resources will be directed towards the rebuild procedure. Highest Highest Priority the RAID controller will utilize all available system resources to rebuild the array. G. Port Number 7402: The listening port number used to log into the WebGUI. 7402 is the default port number. Other port numbers can be used in place of the default as long as they are free. H. Password Setting: The default password hpt can be changed. Note: If the current password is lost or forgotten, you can uninstall and reinstall the Web RAID Management software to restore the default settings. When changing the password, the maximum number of characters allowed is eight. 30

5.2 Setting - Email The HighPoint RAID controller can be configured to send Event Log entries to one or more E-Mail addresses. The email setting has SMTP setting and recipient which users need to configure it. A. Enable Event Check this item to enable Event Notification Notification: B. Server address: This is SMTP mail server address. It can be IP address or SMTP name C. Mail From: This is email address of the sender D. Login Name: The login name of send s email account E. Password: The login password of send s email account F. SMTP Port: This is SMTP port number. The default is 25 for non-ssl SMTP server G. Support SSL: Check this box if using SSL SMTP and change SMTP port to SSL port number. Click Change setting to save new information. H. Support SSL: Setup the recipient s email address I. Name: The name of the recipient J. Event level Check which information that you want to send out for monitoring. The Test check-box is used to verify if email setting is working. 31

6. Web RAID Management Software - Event The Event tab will open the Event View interface. Event View logs all RAID related activity including administrative actions, warnings and hardware failures. There are three options to operate this event log section Clear: Click Clear to remove all current entries from the Event View log. Next: The Event View log can span several pages. Click Next to view past entries. Download: The Event View log can be saved as a text file for reference. 32

7. Web RAID Management Software - SHI (Storage Health Inspector) Storage Health Inspector: SHI will inspect each HDD periodically. If any abnormal status is found, it will be recorded in the Event log. SHI can help to identify problems with HDD s and prevent further damage or data loss. If additional proof of errors is needed, the HDD s can be placed onto the onboard SATA/SAS port and a 3rd party SMART software utility can be run. HDD Temperature Threshold: Setup the HDD temperature threshold to prevent HDD overheating. When the HDD goes beyond the threshold an alert will be triggered. SMART: Schedule SMART attributes for each HDD will be displayed. The following diagram display detail SMART information read out from HDD This allows user to schedule a task to run 33

34

When schedule button is checked, it displays the following configuration page to schedule a task to run. Task List: The Task tab allows you to schedule maintenance sessions for RAID 1, 5, 6, 10 and 50 arrays. User can name each task and specify the frequency, date, hour, minute and second for each session. Regular maintenance is highly recommended for any redundant RAID array, and is essential for maintaining healthy, reliable storage configurations. 35

8. Web RAID Management Software - Recover Recover can help repair RAID arrays that have been assigned the disabled status. This feature helps protect RAID configurations by storing multiple copies of RAID configuration data, which administrators can use to restore a disabled RAID array. Note: Please refer the How-To guide that explains this Recover feature: http://www.highpoint-tech.com/pdf/support/webgui_recover_feature.pdf 36

Appendix B - Web RAID Management ICON Definition List The following table lists the definition of each ICON used by the RAID Management interface (The examples use a RAID 5 array for reference). Icon Description The array status is "Normal". The array has stopped Initializing. Current status is Uninitialized. The array is Initializing : Initializing (Foreground) and Initializing(Background). The array is performing a data consistency checking and its current status is Verifying. The array status is "Critical" - a disk is missing from the RAID array. The array status is "Verifying". This indicates that the array is running a data integrity check. The array status is "Rebuilding". This occurs when the data verification fails or when adding a new disk into the "Critical" array. The array status is "Critical". This indicates that current array needs "rebuild". This icon will also show up on a device in a RAID disk member as needing to "rebuild" its data. The status of the "Array" or "Device" is "Disabled". The array is "Initializing". There are two types of initialization- Foreground and Background. The array OCE/ORLM operation has stopped. This icon means the RAID array is "Uninitialized". On the RAID array either Foreground or Background initialization has stopped (Incomplete). On a disk ( ), it indicates that the disk is not initialized and will need to be initialized for the 1 st time before it can be used with HighPoint RAID card. The device status "Legacy". An existing file system has been created on the HDD. The device is a "Spare". It is used to replace the failed RAID disk member to rebuild automatically. 37

Information. Warning. Error. The array is inconsistent and it needs to rebuild. The current status is Critical. Array disk member diagram is listed below. It shows a RAID-5 disk member is lost and its current status is Critical. Array disk member diagram is listed below. The array is rebuilding and its current status is Rebuilding. Array disk member diagram is listed below. The array is not available. Two scenarios can cause this to happen. First - a lost RAID disk member exceed the minimum required to maintain a RAID level. Second - a disk failed before the initialization or rebuilding process complete. The status is in Disabled. Array disk member diagram is like this: 38

APPENDIX C - RAID Technology Explanation Type Description Mini. disks Usable space JBOD Just a bunch 1 100% Each drive can be of disk accessed as a single volume RAID 1 Disk Mirroring Advantage Disadvantage Application 2 50% It provides convenient low-cost data redundancy for smaller systems and servers RAID 0 Disk Striping 2 100% Offers the highest performance RAID 10 RAID 5 RAID 50 RAID 6 Disk Mirroring followed by stripe Disk Striping with Rotating parity RAID5 set followed by stripe Disk Striping with dual rotating parity 4 50% High read performance and medium write performance with data protection for up to 2-drive failures 3 67-94% High read performance, and medium write performance with data protection with a single drive failure 6 67-94% High read performance, and medium write performance with data protection with a single drive failure 4 50-88% High read performance, and medium write performance with data protection in case of up to two drives failure No fault tolerance - failure of one drive results in complete data loss Useable storage space is 50% of total available capacity No fault tolerance failure of one drive in the array results in complete data lose Useable storage capacity equals total capacity of all drives in the array minus two Not recommended for database applications that require frequent/heavy write sessions. Cost is high because minimum disks requirement is 6 Not recommended for applications that require frequent/heavy write sessions. Backup Operating system, backup, and transaction database. Temporary file, performance driven application. Fast database and application servers which need performance and data protection Data archives, and ideal for application that require data protection Large database, file server, application servers Data archives and ideal for application that requires data protection 39

Appendix D Thunderbolt Daisy Chain configuration Thunderbolt s Daisy Chain feature can connect the host system with 6 Thunderbolt devices (or 5 devices and 1 display). Configuration 1: Connect the host with 6 Thunderbolt Devices. Configuration 2: Connect the host with 5 Thunderbolt devices and one display. Mar. 10, 2014 Copyright 2014 HighPoint Technologies, Inc. All right reserved. 40