DDC4200e Controller with Operator Function

Similar documents
DDC4200e Automation Station with Operator Function

FBU410 Input/ Output Modulel

BMD4032 Input/output module

RCN420-B Room controller

SBM52/04 Input / Output Module For M-Bus with 99 counters

DDC420 Automation Station

FBS51/04 Gateway-Module For M-Bus with 6 counters

FBM034 and FBM034W Fieldbus Input Modules

NOTE Hinweis: Note the special features of firmware updates provided by EPROM-Tausch (see page 4).

SBM51/04 Switch cabinet bus module For M-Bus with 32 counters

FBM018 and FBM018W Fieldbus Input Modules

Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Installation Dimensions...4 Mounting...5 Connection...

BMR410 Controller BMR410. Product Description

TPC84 Display and Operator Panel

TD11..15, TDF Room Temperature Sensors

RCN200-L Room Controller

TLD1..TLD4 Duct Temperature Sensors

TPC70Display and Operator Panel

HT12, HTF12 Room humidity/temperature sensor

TPC35 Display and operator panel

IT554 VPN Router IT554. Product Description

Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Dimensions...4 Connection...4 Mounting...5 Maintenance...

DDC110S Room Control Modul With LCD Display

TPC56 Display and operator panel

RCN155-L, RCN151-L Room controller

RCN122-L technolon Room Controller. Application. RCN122-L technolon Room Controller. Product Description

RCN132-L, RCN132-L-S1 technolon Room Controller

GLT-M002-GLTM GLT-M002-GLTM. Product Description

GLT-D004-TFA4 Color Ink Jet Printer A4

RBW301-C, RBW302-C, RBW304-C, RBW305-C Room Control Module

IT560 VPN router IT560. Commissioning

RCC200-L Room Controller

BCU070-L technolon Switch Interface. Application. BCU070-L technolon Switch Interface. Product description

Commissioning. IT554 VPN Router

Note: Note the changed parameter functions due to firmware updates (see page 5).

RCW11x-L Room Controller Technolon. Application. Product Description. RCW11x-L Room Controller Technolon

BMF400 Input/output module

SBM51/05 gateway module for Berg network monitoring

GLT2200N BMS Network Operator Station

ROUTER-2SHDSL-RAIL-001/01

RBU130-RJ/sw, RBU130-RJ/ws Room Controllers

Neutrino-GLT Server BACnet TM Protocol Implementation Conformance Statement (PICS) Version 3

DDC4200 BACnet TM Protocol Implementation Conformance Statement (PICS) Version 1

Actuating drive with spring return DSFY/16 Modulated actuating drive with spring return

Wireless Small Actuator MAC-WSA

Contents Notice about the device description...page 2. Device description

Neutrino-GLT Client BACnet TM Protocol Implementation Conformance Statement (PICS) Version 4

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Compact Universal Controllers

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

DDC110-L1.. DDC110-L4 technolon Room Module

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Super universal modules

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Electrical Actuators

High-powered control system for sophisticated processes

Non-communicating room controllers

IF-80x Outdoor Terminal

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

PM Series Power Meter

MINI-PS AC/10-15DC/8

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

AIAS. Technical description

Web interface BACnet/IP

DS December Omni BEMS Controller

mark150s mark150/485s DDC controllers Summary

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

Extruder Controls ExtruVision S

Control Panel CP600-eCo CP604, CP604-B

User Manual. Printer P-52RUE

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

Resistance measuring module

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Operating instructions. Switching amplifier DN0210 DN / / 2015

EAGLEHAWK Controller. Product Data. U.S. Registered Trademark Copyright 2016 Honeywell Inc. All Rights Reserved

Access Terminal IF-800

IMIO100 IMIO105. DDC controllers. Summary

Operating instructions. Speed monitor D / / 2014

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

KS 108 easy Compact automation unit for industrial control and process technology

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

clarity 3 Programmable Controller

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

Compact universal controllers

Controlesta RCO-Compact

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Operating and mounting instructions

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Transcription:

Issue 2017-04-13 Datasheet 2.60-10-210-01-EN Controller with Operator Function pplication Color touchscreen with BCnet communication Standalone station with operator function for closed-loop and open-loop control, optimizing and monitoring functions Built-in touchscreen for intuitive, user-defined operation via plant structures which can be individually created Customizable plain text for every parameter Direct connection of the input and output signals 12 DDC closed-loop control plants for heating and ventilation, can be expanded with software objects PLC functions, free and as fixed macros (hardware objects) Software objects for increasing energy efficiency and energy optimization Communication Via TCP/IP, Ethernet cable (min. Cat5, 10/100 Mbit) to enable use of the existing infrastructure Built-in remote control via PC with browser without additional software or mobile end devices Native BCnet in accordance with DIN EN ISO 16484-5, BCnet IP and BCnet MS/TP Up to 99 DDC4000 automation stations with bidirectional data exchange ccess to the entire DDC4000 automation system from every connected automation station (remote control) without additional devices 2 buses (CN-based), configurable for switch cabinet bus or fieldbus for connecting fieldbus modules (FBM/ FBU or RBW4xxx) or switch cabinet bus modules BMD/BM or SBM Error message memory, event logging with date and time, incoming and outgoing messages are saved Forwards messages to printers, fax, GSM-SMS and e-mail. Trend value memory for max. 50.000 trend points. Configuration using modern, effective object structure, considerably reducing project planning time. Embedded Linux operating system for proven, stable use Backward-compatible with Kieback&Peter DDC3000 automation system Constant system monitoring of the bus communication and all connected DDC components, bidirectional data exchange possible. Content Page Important Information Regarding Product Safety...2 Item...3 Technical Data...3 Dimensions...6 Installation Dimensions...6 ccessories (included in delivery)...6 ccessories (not included in delivery)...6 Connection...7 Installation...9 Mounting...10 Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения - változtatások jogát fenntartjuk - Kieback&Peter GmbH & Co. KG Tempelhofer Weg 50, 12347 Berlin/Germany Telefon: +49 30 60095-0, Telefax: +49 30 60095-164 www.kieback-peter.de, info@kieback-peter.com

Datasheet 2.60-10-210-01-EN Issue 2017-04-13 Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer. If the product is not used in accordance with this data sheet, the protection provided will be impaired. pplicable regulations must be observed when installing and using the device. Within the EU, these include regulations regarding occupational safety and accident prevention as well as those from the VDE (ssociation for Electrical, Electronic & Information Technologies). If the device is used in other countries, it is the responsibility of the system installer or operator to comply with local regulations. Mounting, installation and commissioning work on the devices may only be carried out by qualified technicians. Qualified technicians are persons who are familiar with the described product and who can assess given tasks and recognize possible dangers due to technical training, knowledge and experience as well as knowledge of the appropriate regulations. Legend WRNING Indicates a hazard of medium risk which can result in death or severe bodily injury if it is not avoided. CUTION Indicates a hazard of low risk which can result in minor or medium bodily injury if it is not avoided. CUTION Indicates a hazard of medium risk which can result in material damage or malfunctions if it is not avoided. NOTE Indicates additional information that can simplify the work with the product for you. Notes on Disposal For disposal, the product is considered waste from electrical and electronic equipment (electronic waste) and must not be disposed of as household waste. Special treatment for specific components may be legally binding or ecologically sensible. The local and currently applicable legislation must be observed. Page 2 / 10

Issue 2017-04-13 Datasheet 2.60-10-210-01-EN Item Controller with operator function Technical Data Nominal voltage For automation station (terminals 1 and 21): Fuses Inputs and outputs C 24 V +/- 10%; 50 Hz..60 Hz; 22 V; 1.0 or DC 24 V +/- 10%; 11 W; 0.45 or DC 12V +/- 10%; 11 W; 0.9 For binary inputs and outputs (terminals 41 and 61): DC 24V +/- 10%; 1.2 W; 0.05 Time-delay power fuse, 3.15 32 BI/BO configurable, 8 BI (K1 to K8) for pulse counting up to 80 Hz BO: Floating transistor output contact to 0 V = DC 24 V; 50 m 24 Is/Os can be independently configured as: - nalog output - nalog input DC 0(2) V..10 V; max. 2.5 m See table Sensor types, page 5. Separate auxiliary power (terminal 16) DC 10 V; 50 m for connecting external setting knobs Bus connection / interfaces Ethernet RJ45 Enables operation of up to 99 DDC4000 automation stations, users can establish worldwide network via active network components, BMS and BCnet client connection, 10/100 Mb/s, TCP/IP 2 CN buses, configurable as fieldbus or switch cabinet bus Fieldbus; F-bus: up to 63 fieldbus modules FBM, FBU or RBW4xxx, 2000 m; 20 kbd, CN Switch cabinet bus; up to SBM bus: 16 switch cabinet bus modules (SBM or BM/BMD); 200 m; 40 kbd, CN USB socket (behind the front panel) just for USB memory stick: Update, backup/restoration Serial RS232 Modem, fax, printer or remote control for DDC3000 automation station RS485 for BCnet MS/TP: 32 devices, 1000 m, up to 115 kbd, routing in accordance with BCnet/IP CUTION Only connect USB memory sticks to the USB socket. Do not connect any other USB devices. Page 3 / 10

Datasheet 2.60-10-210-01-EN Issue 2017-04-13 NOTE The RS232 or RS485 interface is activated by means of configuration. Only one of the two interfaces can be used. The default setting is inactive. You can find further information in the DDC4000 project planning documentation Section "SY_Serial" Objects NOTE The CN-bus fieldbus offers 63 bus addresses and the switch cabinet bus offers 16 bus addresses. The maximum number of connectible input/output modules depends on the selected device types. Further information can be found in he DDC4000 project planning documentation. Displays Touchscreen with active backlit ¼ VG color active matrix LCD display 14 cm screen size (5.7 inch) Memory 4 GB flash; 512 MB RM) Operating system Embedded Linux Mains failure 7 years, battery-buffered clock module data backup Degree of protection IP20 Overvoltage category III Rated impulse voltage 800V Level of contamination 2 How It Works Type 1 mbient temperature 0 C to 50 C mbient humidity During operation: 20% to 80% r.h., non-condensing Out of operation: 5% to 90% r.h., non-condensing Housing 19" plastic short enclosure, quadruple enclosure with base and extra connections for Ethernet RJ45 and RS232 WxHxD: 202 x 132 x 137 mm Front panel cutout 200.4 mm x 112.0 mm Weight 1.15 kg Label CE Page 4 / 10

Issue 2017-04-13 Datasheet 2.60-10-210-01-EN Sensor types Sensor type Measuring range 0(2) V..10 V 0%..100% KP10-50 C..+150 C KP250-50 C..+150 C ML2-50 C..+150 C Ni100-50 C..+150 C Ni1000 (DIN) -50 C..+150 C Ni1000 (L&G) -50 C..+150 C NTC1,8K -50 C..+150 C NTC5K -50 C..+150 C NTC10K -40 C..+150 C NTC10KPRE -50 C..+150 C NTC20K -30 C..+150 C PT100-100 C..+850 C PT1000-100 C..+850 C Balco500-40 C..+150 C Satchwell DC1100-20 C..+120 C Satchwell DC1400-40 C..+120 C Resistor (potentiometer) 0..10 k NOTE You can find more information on the sensor types in the Temperature Sensor Tables product description (1.10-90.100-01). Page 5 / 10

Datasheet 2.60-10-210-01-EN Issue 2017-04-13 Dimensions 202,4 14,5 105,5 23,8 Installation Dimensions 112 +0,5 5,25 110,0 132,5 Ø 3,0 3,5 x13 5,25 11,3 11,3 200,4 +0,5 ccessories (included in delivery) USBSTICK-DDC-MINI USB stick ccessories (not included in delivery) Z23 DDC4e-LON Wall bracket for the DDC3000/DDC4000 automation station Installation note 2.85-10.023-99 contains further information on the installation (included with accessory Z23). RS232-LON adapter Data sheet 2.60-10.220-01 provides more information (included with theddc4e-lon accessories). Page 6 / 10

Issue 2017-04-13 Datasheet 2.60-10-210-01-EN Connection +24/12VDC 1 21 0VDC Y 41 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 K13 K14 K15 K16 +24VDC 0VDC 24VC 0VC 61 61 41 41 61 k1 k17 K17 42 62 k2 k18 K18 43 63 k3 k19 K19 44 64 k4 k20 K20 45 65 k5 k21 K21 46 66 k6 k22 K22 47 67 k7 k23 K23 48 68 k8 k24 K24 49 69 k9 k25 K25 50 70 k10 k26 K26 51 71 k11 k27 K27 52 72 k12 k28 K28 53 73 k13 k29 K29 54 74 k14 k30 K30 55 75 k15 k31 K31 56 76 k16 k32 K32 57 77 58 59 60 78 79 80 (-) B (+) RS485 B1..B24 CN1 B1/Y1 B2/Y2 B3/Y3 B4/Y4 B5/Y5 B6/Y6 B7/Y7 B8/Y8 B9/Y9 B10/Y10 B11/Y11 B12/Y12 +10V/50m 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Y B13/Y13 B14/Y14 B15/Y15 B16/Y16 B17/Y17 B18/Y18 B19//Y19 B20/Y20 B21/Y21 B22/Y22 B23/Y23 B24/Y24 CN2 RJ45 RS232 CUTION lways use separate power supply units for supplying power to the controller (terminals 1 and 21 ) and the binary inputs and outputs (terminals 41 and 61 ). CUTION Ensure that no third persons can access your data during data transfer. Only use secure solutions when connecting to public networks (VPN). CUTION Use secure passwords to protect your data, devices and plants from unauthorized access. secure password consists of lowercase and uppercase letters, numbers and special characters. It must also be long enough. Change the passwords directly after transfer of the plant, commissioning of the device or importing software. Change the passwords at regular intervals. Use different passwords. You are responsible for the security of your data and/or plant. Page 7 / 10

Datasheet 2.60-10-210-01-EN Issue 2017-04-13 Sensor and actuator connection 0..10VDC ϑ - + 24VC 24V 0V b 0V 24V 0..10V DC 24VC 24V 0V 24V 0V Y K1..K32 k1..k32 41 61 15 24 VDC 0 VDC 2 22 35 B1..B24 21 Y B1..B24 21 Y1..Y24 Y 36 37 B CUTION The wiring specified in the wiring diagram (Y, K, ) must be observed. Incorrect wiring may lead to errors in measurement. Page 8 / 10

Issue 2017-04-13 Datasheet 2.60-10-210-01-EN Installation CUTION Switching on the power supply of unparameterized products can lead to unforeseen consequences such as malfunctions or material damage. Switch on the power only after the device has been configured by the commissioning technician. CN bus When connecting the CN bus, use a cable with 2 x 2 leads stranded into a pair with plastic insulation and electrostatic shielding with a lead diameter of at least 0.8 mm. Use a stranded pair of wires for the data lines (+ and -) and another free wire for the ground (0). t the end of the CN bus (furthest point from the controller), install a terminating resistor of about 180 ohms between the two data lines (+ and -). The terminating resistor is included with the controller. When using CN bus as a fieldbus, the maximum cable length is 2,000 m. When using CN bus as a switch cabinet bus, the maximum cable length is 200 m. Make sure to observe the line topology for the CN bus. RS485 for BCnet MS/TP To connect the MS/TP bus, use at least one cable of the type JY(St)Y 2x2x0.8 Lg: Two x two leads stranded into a pair with plastic insulation and electrostatic shielding with a lead diameter of at least 0.8 mm and a characteristic impedance between 100 and 130 ohms. Use a stranded pair of leads for the data lines and another free lead for the ground connection. Observe the polarity of the data lines of the MS/TP. Terminal 78 supplies the inverted signal, it is usually labeled with (-). Terminal 79 supplies the non-inverted signal, it is usually labeled with B (+). Terminal 80 is used for the ground connection. t the start and end of the MS/TP bus, install a terminating resistor of ideally about 120 ohm between the two data lines. The DDC4000 is fitted with a 120 ohm terminating resistor that can be activated via configuration. Further information can be found in the DDC4000 project planning documentation Foreign devices often enable a switchable terminating resistor. Refer to the data sheet or the respective manufacturer s manual for further information. Use bias resistors to maintain the bus idle level at a defined high level and to prevent noise being misinterpreted as a data signal. We recommend that you use network bias resistors on the first and last device on the bus. maximum of 2 devices on the bus may be equipped with network bias resistors. The DDC4000 is fitted with a 680 ohm bis resistor that can be activated via configuration. Further information can be found in the DDC4000 project planning documentation Foreign devices often offer optionally switchable bias resistors. The maximum possible bus length is 1000 m. maximum of 32 devices can be operated on a bus segment. Observe the line topology for the RS485 bus. Page 9 / 10

Datasheet 2.60-10-210-01-EN Issue 2017-04-13 Mounting WRNING Contact with live parts of electrical domestic installation can cause death due to electric shock. Mounting/removal may only be carried out when power is switched off. Front installation 3,5x13 1 2 3 4 BZ 2,9x16 5 6 19" K rack K M3x11 1 2 3 4 M3x15 5 6 Page 10 / 10