DC Power Considerations for Intrinsically Safe Applications

Similar documents
Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power

Appendix B MTL Power Supplies for Intrinsically Safe Fieldbus Applications

Distributed Intrinsically Safe Fieldbus Applications

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

Trusted Strategic Partners in Process Automation. Alliance Member

Non-Incendive Fieldbus for Simplified Maintenance

FF Physical Layer Components

Fieldbus Foundation TM Physical Design. Joseph Khoo AP Regional Sales Director R.Stahl

Introduction to Fieldbus Foundation Physical Layer

The High Power Trunk Alternative to FISCO and FNICO

MANUAL Surge Protectors

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs

Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry

5 Fieldbus Technology

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

PROCESS AUTOMATION. MANUAL Compact Fieldbus Power Hub, Common Interface

PROCESS AUTOMATION MANUAL FIELDBUS POWER HUB INVENSYS

High Availability Fieldbus Networks in Hazardous Areas

High Availability Fieldbus Networks New Physical Layer Technologies. : Nagesha Nayak : Manager Project Pursuit

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Benefits derived from the FF specification FF-831

PROCESS AUTOMATION. Installation Technology for FOUNDATION Fieldbus

FOUNDATION Fieldbus Fieldbus Basics & its Benefits

MANUAL SEGMENT CHECKER

Connecting a Cisco Input Module

Installing Fieldbus. Installing Fieldbus

Tech Note. Page 1 of 34 TECHNICAL NOTE ADVANCED DIAGNOSTICS IN EMERSON ENVIRONMENT 11/03/2014 TDOCT-1558CENG

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

Uniflo 1200 GVEC Accessories Uniwire to RS232 converter

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Basics of setting up. PROFIBUS-PA networks. Martin Ruck Siemens. Jason Nicholl Phoenix. Kris Hardaker United Utilities

Connecting a Cisco Output Module

SIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E ) 01/2010

L5353 Profibus-DP Communications Interface

Installing Fieldbus: Some practical advice, Part 1

Proudly present. Ethernet to the Field (APL)

Installation & Operation Manual

SMARTLINE RM76 Supplementary instructions

PROCESS AUTOMATION INSTALLATION TECHNOLOGY FOR PROFIBUS PA

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

7/2005. Reprint. Oldenbourg. Automation Technology in Practice. Breakthrough in Fieldbus technology High Power Trunk concepts.

FOUNDATION Fieldbus Fieldbus Basics

10 Mb/s Single Twisted Pair Ethernet Power Distribution

PROCESS AUTOMATION MANUAL F2-SP-IC*

MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Installation & Operation Manual

ABB Fieldbus Infrastructure and Network Devices An overview

M-series Foundation Fieldbus I/O

MTL8000-2/x Series Modular I/O

UIM Series Flowmeter Field Wiring Guide

KOBOLD Compact Electronics

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

How can I. Connect PlantStruxure to FOUNDATION Fieldbus? Design Your architecture. System Technical Note Optimized functional unit

PROFIBUS and Integrated Safety architectures in Ex areas

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Operating Instructions and Description of Instrument Function Prothermo NMT539

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install

MANUAL Temperature Multi-Input Device

Diagnosis Concepts for Foundation H1 Physical Layer Diagnosis: from simple & effective to powerful & sophisticated

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Submittal Data Sheet WAGO Node for itm

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

FIELDBUS IN ONGC C2C3 PLANT

About the FLEX Ex I/O Systems

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

PROFIBUS Course Document Certified PROFIBUS Installer Course CPI Version 1.1 June 2011 Order No: PROFIBUS Learning Outcomes, Order No: 4.

RT2Y Compact temperature switch intrinsic safety

USER S MANUAL Power Supply for Backplane Vdc

Technical Manual. HA Issue 4. Copyright Parker SSD Drives, Inc 2008

PROCESS AUTOMATION SIMPLIFY PROCESSES FIELDCONNEX INFRASTRUCTURE FOR PROFIBUS PA

MANUAL MODULAR SEGMENT PROTECTOR

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Sigma XT Ancillary Board (K588)

PROFIBUS-DP/MODBUS RTU REPEATER

Installation and Setup

FEATURES DESCRIPTION MODEL 110B. Power Supply

Accessories IC690ACC900

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

General Specifications

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

TYPE APPROVAL CERTIFICATE

Installation and Wiring

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Electrical Demand Specification (Reference SOP: )

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

FOUNDATION. Product Overview. Foundation Fieldbus

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

IEEE Mb/s single twisted pair Ethernet for Process Industry

APPLICATION NOTE. Advanced Diagnostic PRM Integration. COM port Packing and Field Device Tag Import

S900 Remote I/O System Intrinsic safety in the field ABB

DeltaV S-series Traditional I/O

Transcription:

Chapter 3 Intrinsically Safe Fieldbus Applications This chapter provides information about fieldbus applications that provide Intrinsically Safe (IS) power to fieldbus devices located in hazardous areas. The Pepperl+Fuchs FieldConnex Fieldbus Power Hub and FieldConnex FieldBarrier provide Intrinsically Safe power for both Intrinsically Safe entity applications and FISCO (Fieldbus Intrinsically Safe COncept)applications. Refer to the Pepperl+Fuchs (P+F) documentation and/or visit the DeltaV website (www.easydeltav.com) and follow the links for additional information on these products. Ensure that the fieldbus devices and all components used in the application are rated and certified for IS applications. Warning In any hazardous area installation it is important to read and follow the device manufacturer's design and installation documents. Failure to follow the documentation could result in an unapproved and unsafe application. Additionally, in hazardous locations follow your plant's procedures for making the area safe during installation and maintenance operations. DC Power Considerations for Intrinsically Safe Applications The basic IS application uses the Fieldbus Power Hub with the Isolated Power Supply Module to provide power to field devices connected through one or more IS Field. The available power to a field device depends on the length and resistance characteristics of the fieldbus cable to each and the output characteristics of the to the field device. The P+F segment calculator tool was used to make the example calculations in Table 6 on page 53. The calculations show the maximum distance for a given load on the Fieldbus Power Hub for applications using Intrinsically Safe Fieldbus Applications 51

2, 3, and 4 Field to connect up to 16 field devices. The calculations are based on the following assumptions: Power Supply Voltage = 28.0 VDC @ 500 ma Minimum Voltage at last Barrier = 16 VDC Minimum Device Voltage = 9 VDC Maximum Voltage drop from cable to last barrier = 12 VDC Redundant H1 connected at a load of 24 ma Each device has an average load of 20 ma Ensure that any device load on a spur output from the field barrier is 30 ma or less Each Barrier spur has a maximum of one device connected. and Devices are connected on one end of the cable and the Fieldbus Power Hub is connected on the other end of the cable Each device is connected on a 10 meter maximum spur cable. are inter-connected on a 10 meter maximum trunk cable. Fieldbus Type A 18 AWG cable @ 22 ohms/km (44 ohms/km loop resistance) at 22 C Maximum Distance (km) = (Allowed Loop V drop / Loop current) / Loop resistance per km There will be different restrictions and limitations on your segment if these assumptions do not hold for your segment layout. If your devices average more than 20 ma per device, reduce the maximum cable length indicated in the table for that number of devices or reduce the number of devices on the segment. Refer to the device documentation for information on current requirements for the device. When referring to Table 6, remember the Redundant Series 2 H1 card requires 24 ma of fieldbus power. The loads listed are the normal loads required by the barriers and devices. However, the numbers take into account the additional current required if the smallest load on one barrier is accidentally shorted (during a maintenance operation) to protect the segment from being affected. If these assumptions do not properly represent your specific application, it is recommended that a calculation be completed to verify that the segment design adequately meets your process requirements. 52 Fieldbus Installations in a DeltaV Digital Automation System

Table 6 Distance per Load on the Fieldbus Power Hub with Field Number of Devices / Load (ma) Distance (meters) and Power Supply Load (ma) Max Distance with 2 Power Supply Load with 2 Max Distance with 3 Power Supply Load with 3 Max Distance with 4 Power Supply Load with 4 1 / 20 1875 75 1850 103 1575 131 2 / 40 1850 94 1625 123 1400 151 3 / 60 1675 112 1425 143 1250 171 4 / 80 1500 130 1275 161 1125 192 5 / 100 1325 149 1150 180 1025 211 6 / 120 1200 163 1050 198 950 231 7 / 140 1000 184 975 218 875 250 8 / 160 1000 208 900 237 800 267 9 / 180 N/A N/A 825 256 750 288 10 / 200 N/A N/A 775 274 700 307 11 / 220 N/A N/A 725 290 650 325 12 / 240 N/A N/A 725 316 625 346 13 / 260 N/A N/A N/A N/A 600 366 14 / 280 N/A N/A N/A N/A 550 378 15 / 300 N/A N/A N/A N/A 525 395 16 / 320 N/A N/A N/A N/A 525 422 16 / 340 N/A N/A N/A N/A 475 429 16 / 360 N/A N/A N/A N/A 425 433 Fieldbus Power Hub Refer to Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power on page 39 for information on the Fieldbus Power Hub system. Intrinsically Safe Fieldbus Applications 53

for Intrinsically Safe Applications in Hazardous Locations S1 terminator switch The connects up to four field devices located in hazardous locations to the fieldbus segment and provides short circuit protection to each device. Ensure that any device load on a spur output from the field barrier is 30 ma or less. Figure 11 shows a for four devices. Spur connections Trunk connections 10+ 11 12s 13+ 14 15s 16+ 17 18s 19+ 20 21s ON S1 BUS _ TERM. 1 OFF 2 3 4 1B 2B 143+ 4-5s 6s 7-8+ Spur connections 1-4 Trunk connections 1-2 Figure 11 for Four Devices Installing and Connecting the Fieldbus Power Hub Refer to Installing and Connecting the Fieldbus Power Hub on page 46 for information on installing the Motherboard, Power Supply Modules, and Diagnostics Modules and connecting the Fieldbus Power Hub. 54 Fieldbus Installations in a DeltaV Digital Automation System

Installing and Connecting the Refer to Figure 11 on page 54. To install and connect a 1. Securely attach the at the desired location. 2. For the Trunk segment connection: connect the positive (+) segment wire to the positive, connect the negative (-) segment wire to the negative, and connect the segment shield (S) to the S. 3. Remove the shorting jumpers (1B, 2B) so that the Trunk (S) shields are isolated from, not connected to the case. 4. For each device connection: connect the positive (+) spur wire to the positive, connect the negative (-) spur wire to the negative, and connect the shield wire (S) to the S. 5. The Spur (S) shields must be connected to the case and isolated at the device in the field. The best way to ground the output shields at the barrier is with a mechanical connection through a metal gland or bar at the barrier. 6. If this is at the end of the segment, the terminator switch S1 should be in the On position. If this is not the end of the segment, ensure that the terminator switch S1 is in the Off position. 7. If the segment continues and connects to another, continue the Trunk segment by connecting the Trunk Out connections to the next Field Barrier and proceed with steps 3, 4, and 5. 8. Ensure that the shorting jumpers (1B, 2B) are removed on all Field, so that the Trunk (S) shields are isolated from not connected to the case. 9. If this Barrier is the end of the segment, ensure that the terminator switch S1 is in the On position. Verifying the Installation Refer to Verifying the Installation on page 48. Intrinsically Safe Fieldbus Applications 55

PEPPERL+FUCHS PEPPERL+FUCHS PEPPERL+FUCHS PEPPERL+FUCHS Intrinsically Safe Application Example Figure 12 shows an application that uses a redundant pair of Series 2 H1 cards with redundant fieldbus power and intrinsic safety barrier protection for 16 devices on a long (0.5 km) trunk cable. If a failure occurs on an H1 card, a 24 V power supply, or a fieldbus power supply, the segments continue to operate as expected. A status indication on connected alarms alerts the operator that an error has occurred. It is assumed that the application design follows the criteria specified in DC Power Considerations for Intrinsically Safe Applications on page 51. Therefore, if a short occurs when a device is installed or removed from the segment, only that device is affected; the rest of the segment is unchanged. T - OFF Series 2 Power/Active Error Series 2 Power/Active Error Redundant Series 2 H1 cards Port 1 Port 2 Port 1 Port 2 Fieldbus H1 Fieldbus H1 Carrier shield bar T - OFF Alarm contacts Port 1 Port 2 Host A Host B Host A Host B Host A Host B SEG1 SEG2 SEG3 S + S --- + S + S --- + S + S --- + ON OFF ON OFF ON OFF Alarm Diagnostic Bus Host A Host B SEG4 S + S --- + ON OFF PRI SEC Primary 24 VDC Secondary 24 VDC Alarm jumper T - OFF FieldConnex DMB PEPPERL-FUCHS Fieldbus Power Hub Fieldbus Motherboard OFF + S OFF + S OFF + S OFF + S Segment 1 Segment 2 Segment 3 Segment 4 Shielded pair with drain wire T - ON T - ON 0.5 km Cable Figure 12 IS Application with 16 Devices Using the Fieldbus Power Hub and 56 Fieldbus Installations in a DeltaV Digital Automation System