HD32.7 HD HD [ GB ] 8-input Data Logger for Pt100 probes with SICRAM module

Similar documents
HD2107.1, HD2107.2, HD2127.1, HD2127.2

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

HD Common features. Common features. TP49AP: Penetration probe, Pt100sensor. Stem Ø 2.7mm, length 150mm. Cable 2 meters long.

HD HD [ GB ] Probes for soil volumetric water content measurement. Temperature. Humidity PART OF G H M GROUP TELEMETRIE & AUTOMATION

HD B. [ GB ] Precision Barometer

HD 9609 INSTRUCTIONS MANUAL

HD TP472I.0 1/3 DIN Thin Film. TP473P.0 1/3 DIN Thin Film. TP474C.0 1/3 DIN Thin Film. TP475A.0 1/3 DIN Thin Film. TP49A.0 Class A Thin Film

HD2010 UC/A. Integrating Sound Level Meter Portable Analyzer. Basic screen. Time profile. Octave band spectrum

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

Precision digital measuring device PHYSICS 51

PHYSICS Digital Measuring Devices

HD32.7 RTD DATALOGGER ENGLISH

ENVIRONMENTAL MONITORING & CONTROL

USB-500/600 Series Low-Cost Data Loggers and Accessories

HD HD

HD33[L]MT.GSM HD33[L]MT.3G GSM/3G data loggers for weather stations

HD HD [ GB ] Probes for soil volumetric water content measurement

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart

ENVIRONMENTAL MONITORING & CONTROL

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

Multi-functional precision thermometer CTR3000

USB-5100 Series Multi-Channel Data Loggers

HD2110. Integrating Sound Level Meter Analyser. Basic screen. Time profile. Octave band spectrum

Hand-held thermometer, precision version Model CTH6500 Model CTH65I0, Ex version

Specification for temperature sensor calibration setup

2YL-T15-4M & 2YL-T16-4M Thermocouple Loggers. 2YL-M36-4M & 2YL-M37-4M Multi Terminal Input Loggers. 2YL-M61-4M & 2YL-M62-4M Lux Loggers

Phone: Fax: For calls outside the US please call:

HD33[L]M.GSM HD33[L]M-MB.GSM GSM data loggers for weather stations

C.A 1821 / C.A 1822 / C.A 1823

Portable Multi-Function Calibrator Model CEP6000

UNIVERSAL TEMPERATURE TRANSMITTER

UNIVERSAL MONITORING SYSTEM MS5D, MS5

C.A 1821 / C.A 1822 / C.A 1823

C100 Portable Multifunction

English. Operating manual. Multiparameter portable instrument HD Keep for future reference. Companies / Brands of GHM

HI 9828 Multiparameter Water Quality Meter...

HygroPalm 0. Portable Humidity Temperature Indicator. Instruction Manual

HI 9828 Multiparameter Water Quality Meter...

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

USB-5100 Series Multi-Channel Data Loggers

S 551 COMPRESSED AIR ANALYZER

AQ 200 AQ 200 Air Quality

Hand-held thermometer Model CTH6200

MCX II. Druck Portable Documenting Calibrator. GE Sensing. Features. Applications

Hand-held thermometer Model CTH7000

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

PTU300 Combined Pressure, Humidity and Temperature Transmitter

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

TEMPERATURE CALIBRATOR TC305

DX4085 Z-Meter Tester

TITAN S8. Transportable Data Acquisition Device. Product Brochure EN

Squirrel Portable Data Loggers For research, quality assurance and production monitoring in industry, environmental sciences and in the laboratory

Supplied with. Calibration certificate. HD 200 Hygrometer

HD 9817T1R HD 9817T2R HD 9817T3R HD 9817TVS

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Advanced Signal Calibrator ASC-400. User friendly and innovative

Millenium II +: general characteristics

MULTICHANNEL DATA RECORDERS

Data logger systems from ROTRONIC

world class water monitoring series 42

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

L200 User Manual. Operating Instructions for L200-TC & L200-PT Temperature Monitor. RoHS compliant

Hand-Held Thermometer Model CTH 6200

IMS4 AMS 111 II M. Automatic Mobile Weather Station for military usage AMS 111 II M

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

TRX II. Portable documenting calibrator

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

Battery operated recorders. Built-in battery operated GSM modem Text message alerts Data collecting to Comet database software and Comet cloud

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

Vaisala Veriteq VL 2000 Temperature Humidity Loggers

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

DMT345 and DMT346 Dewpoint Transmitters

for measuring ph values and redox potential, conductivity and dissolved oxygen Content

HD 2013 HD 2013-D AA-26 AA-27

Manual Digital Thermometer PCE-T 390

CMP Applications. Features

Hygro-Thermometer / Datalogger

MMS3000-GP MMS3000-GP MMS3000 MMS3000-GP MMS3000-GP4 GP8

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version

MULTICHANNEL DATA RECORDERS

GA-12. madur Polska sp. z o.o.

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Supplied with. Calibration certificate. TM 200 Thermometer

Terminals. Spectrometer Probes. i::scan Ionselective. Probes. Physical Probes. Terminals. Software System. Configuration. Monitoring Stations

PCD DIGITAL Differential pressure probe

Bezprzewodowe rejestratory temperatury i wilgotności do transportu samochodowego HD35EDLT.GSM REV /08/2016 HD35EDLT.GSM.

Electronic pressure switch with display Model PSD-4

HD 2070 [ GB ] Three channel vibration analyzer. Base screen: single axis measurements. Base screen: vector measurements.

RMS Mini Wireless Data Logger

Ultra-Accurate Measurement for Temperature and Voltage

Analog input module. Data sheet. for MULTICAL 603

log TM Humidity. Temperature. Voltage. Current. Radiation. Pulse. Light. Pressure. DATA LOGGING. SIMPLY.

SINTESYS SMART MODULE OBD READER THE ENHANCED AND PROFESSIONAL AUTODIAGNOSIS SMART AND FLEXIBLE AUTODIAGNOSIS POWERFUL EOBD/OBD-II DIAGNOSIS

Sentinel AC & DC Current Logger Models SDL A401 & SDL A402

Transcription:

[ GB ] HD32.7 8-input Data Logger for Pt100 probes with SICRAM module HD32.8.8 8-input Data Logger for thermoucouple types, K, J, T, N, R, S, B, E HD32.8.16 16-input Data Logger for thermoucouple types, K, J, T, N, R, S, B, E

HD32.7 8-input Data Logger The HD32.7 instrument is a rugged 8-input data logger for Pt100 temperature probes complete with SICRAM module. Configurable unit of measurement: C, F, K. Flash memory, organized in 64 blocks, for a total capacity of 800,000 recordings divided among the existing inputs. The recording can be handled in two ways: - when the available memory is full, the collected data are overwritten starting from the oldest ones (circular memory), - the recording stops when the available memory is full. Simultaneous display of the 8 inputs. Maximum, minimum or average of the logged values. Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour. Data logging: instantaneous or postponed, with the possibility of selecting the recording start and end time. Data download: RS232C, 1200...38400 baud or USB 1.1 2.0. DeltaLog9 software, for data download and processing. LCD backlit graphic display 128x64 pixel. Instrument setup through the keyboard; no connection required to the PC. Security password for keyboard locking. Power supply: 4 1.5V alkaline C-BABY type batteries, or external power supply 12VDC-1A. Consumption @6VDC: <60µA in sleep mode with 8 probes connected <40mA during data logging with 8 probes connected Use of the HD32.7 data logger: in the field for machine or equipment measurements, plant or machine testing, production check, oven mapping. Keyboard locking Memory Storage capacity Security of stored data Power supply Power absorbed @6VDC: Autonomy with password. Divided into 64 blocks. Up to 800,000 recordings divided among the existing inputs; for example with one probe connected, 800,000 recordings, with 8 probes connected, 96,000 recordings each. Unlimited. 4 1.5V alkaline C-BABY type batteries External power supply 12VDC-1A. Connector, external 5.5mm, internal 2.1mm. <60µA in sleep mode with 8 probes connected <40mA during data logging with 8 probes connected 200 hours with 7800mAh alkaline batteries and 8 probes connected Technical specifications Number of inputs 8x 8-pole male DIN45326 connectors. Instrument accuracy during data logging ±0.01 C ±1digit (in the range ±199.99 C) ±0.1 C ±1digit in the remaining range Internal watch accuracy Unit of measurement 1min/month max deviation C, F, K Data download RS232C from 1200 to 38400 baud, galvanically isolated. Sub D 9-pole male connector. USB 1.1 2.0 galvanically isolated. Operating conditions Operating temperature -5 50 C Storage temperature -25 65 C Working relative humidity 0 90% RH without condensation Protection degree IP64 Resolution 0.01 C (in the range ±199.99 C) 0.1 C in the remaining range Display LCD backlit graphic display 128x64 pixel. 12 Vdc 1A USB 1.1-2.0 RS232C Keyboard 15 keys; it can be configured without a PC.

Instrument Dimensions (Length x Width x Height) Weight Materials Probes 220x180x50 mm 1100 g (batteries included) ABS, polycarbonate and aluminium All the Delta Ohm Pt100 probes complete with SICRAM module series TP47..., TP49... can be connected. Other sizes are available on request. Order codes HD32.7: 8-input data logger instrument for Pt100 temperature probes complete with SICRAM module. The kit includes the HD32.7, 4 1.5V alkaline C-BABY type batteries, operating manual, Delta- Log9 software, and carrying strap. The probes, tripod, carrying case and cables must be ordered separately. DeltaLog9: Additional copy of the software for data download and management on PC using Windows 98 to XP operating systems. HD32.7 probes All the Pt100 temperature probes complete with SICRAM module can be connected to the instrument. Other sizes are available on request. HD32.7 accessories 9CPRS232: Connection cable with Sub D 9-pole female connectors for RS232C (null modem) CP22: Connection cable USB 2.0 connector type A - connector type B BAG32.2: Carrying case for the HD32.7 instrument and accessories HD32CS: Carrying strap SWD10: 100-240VAC/12VDC-1A stabilized mains power supply VTRAP32: Tripod complete with 6-input head and 5 probe holders code HD3218K HD3218K: Shaft for another probe HD32CS SWD10

HD32.8.8 8 8-input Data Logger for thermocouple HD32.8.16 16-input Data Logger for thermocouple The HD32.8.8 and HD32.8.16 instruments are rugged data loggers. The former has 8 inputs, the latter has 16 inputs. They work with thermocouple probes type K, J, T, N, R, S, B and E with miniature connector. Configurable unit of measurement : C, F, K. Flash memory, organized in 64 blocks, for a total capacity of 800,000 recordings divided among the existing inputs. The recording can be handled in two ways: - when the available memory is full, the collected data are overwritten starting from the oldest ones (circular memory), - the recording stops when the available memory is full. Simultaneous display of 4 inputs. Maximum, minimum or average of the logged values. Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour. Data logging: instantaneous or postponed, with the possibility of selecting the recording start and end time. Data download: RS232C, 1200...38400 baud or USB 1.1 2.0. DeltaLog9 software, for data download and processing. LCD backlit graphic display 128x64 pixel. Instrument setup through the keyboard; no connection required to the PC. Security password for keyboard locking. Power supply: 4 1.5V alkaline C-BABY type batteries, external power supply 12VDC-1A or PC USB port. Concumption @6VDC: <60µA in sleep mode with all probes connected <40mA during data logging with all probes connected Use of the HD32.8.8 and HD32.8.16 data loggers: in the field for complex machine or equipment multi measurements, machine testing, pharmaceutical and food industry, oven mapping, air conditioning units, etc. Technical specifications Number of inputs Connection 8 for the HD32.8.8 16 for the HD32.8.16 Miniature female socket for thermocouple Instrument accuracy and measurement range Tc: K -200 +1,370 C / ±0.1 C up to 600 C ±0.2 C over 600 C Tc: J -100 +750 C / ±0.1 C up to 400 C ±0.2 C over 400 C Tc: T -200 +400 C / ±0.1 C Tc: N -200 +1,300 C / ±0.1 C up to 600 C ±0.2 C over 600 C Tc: R +200 +1,480 C / ±0.3 C Tc: S +200 +1,480 C / ±0.3 C Tc: B +200 +1,800 C / ±0.4 C Tc: E -200 +750 C / ±0.1 C up to 300 C ±0.2 C over 300 C The accuracy refers to the instrument only. Any error due to the thermocouple or the cold junction reference sensor is not included. Resolution Temperature drift @20 C Drift after 1 year Internal watch accuracy 0.05 C in the range ±199.95 C 0.1 C in the remaining range 0.02%/ C 0.1 C/year 1min/month max deviation Unit of measurement Display C, F, K LCD backlit graphic display 128x64 pixel. HD 32.8.16 HD 32.8.8

Keyboard Keyboard locking function Memory Storage capacity Security of stored data Power supply Power absorbed @6VDC: Autonomy 15 keys; the instruments can be configured without a PC. with password. Divided into 64 blocks. Up to 800,000 recordings divided among the existing inputs; for example with one probe connected, 800,000 recordings; with 8 probes connected, 96,000 recordings each. Unlimited. 4 1.5V alkaline C-BABY type batteries External power supply 12VDC-1A. Connector, external 5.5mm, internal 2.1mm. Power supply via the PC USB port. <60µA in sleep mode with all probes connected <40mA during data logging with all probes connected 200 hours with 7800mAh alkaline batteries, with all probes connected Data download RS232C from 1200 to 38400 baud, galvanically isolated. Sub D 9-pole male connector. USB 1.1 2.0 galvanically isolated. Operating conditions Operating temperature -5 50 C Storage temperature -25 65 C Working relative humidity 0 90% RH without condensation Protection degree IP64 Instrument Dimensions (Length x Width x Height) 220x180x50 mm Weight 1100 g (batteries included) Materials ABS, polycarbonate and aluminium Probes All the thermocouple probes type K, J, T, N, R, S, B, and E can be connected using a male miniature connector. In addition to the K probes available in the catalogue, Delta Ohm can supply different probes on request. Order codes HD32.8.8: 8-input data logger instrument for thermocouple types K, J, T, N, R, S, B, and E. The kit includes the HD32.8.8, 4 1.5V alkaline C-BABY type batteries, operating manual, DeltaLog9 software, carrying strap. The probes, tripod, carrying case and cables must be ordered separately. HD32.8.16: 16-input data logger instrument for thermocouple types K, J, T, N, R, S, B, and E. The kit includes the HD32.8.16, 4 1.5V alkaline C-BABY type batteries, operating manual, DeltaLog9 software. The probes, tripod, carrying case and cables must be ordered separately. DeltaLog9: Additional copy of the software for data download and management on PC using Windows 98 to XP operating systems. HD32.8.8 and HD32.8.16 probes All the thermocouple types K, J, T, N, R, S, B, and E can be connected using a standard miniature connector. Other sizes are available on request. HD32.8.8 and HD32.8.16 accessories 9CPRS232: Connection cable with sub D 9-pole female connectors for RS232C (null modem) CP22: Connection cable USB 2.0 connector type A - connector type B BAG32.2: Carrying case for the HD32.8 instrument and accessories HD32CS: Carrying strap SWD10: 100-240VAC/12VDC-1A stabilized mains power supply VTRAP32: Tripod complete with 6-input head and 5 probe holders code HD3218K HD3218K: Shaft for another probe BAG32.2

Manufacture of portable and bench top instruments Current and voltage loop transmitters Temperature - Humidity - Pressure Air speed - Light - Acoustics ph - Conductivity - Dissolved Oxygen - Turbidity Elements for weather stations SIT CENTRE N 124 Temperature - Humidity - Pressure - Air speed - Photometry/Radiometry - Acoustics RoHS 2002/95/EC Delta Ohm srl - Via G. Marconi, 5-35030 Caselle di Selvazzano (Pd) - Italy Tel. 0039 0498977150 r.a. Fax 0039 049635596 - E-mail: deltaohm@tin.it Web Site: www.deltaohm.com 01 04.07