Broadband Automatic Disconnect Switch. User Manual

Similar documents
Rack Power Distribution Unit AP7530, AP7540

Owner s Manual. Industrial-Grade USB 3.0 Hub. Models: U IND (4-Port), U IND (7-Port), U IND (10-Port)

AC4G-D User s Manual

Owner s Manual. USB 3.1 Gen 1 USB Type-C to DVI Adapters

DisplayPort Multi-Display Splitter/Expanders. Models: B , B DVI, B HDMI

Owner s Manual. USB 3.1 Gen 1 USB-C to HDMI Adapter

Owner s Manual. 2-Port DB9 RS-232 Serial PCI Card

Owner s Manual. HDMI Over Cat5 1x2 Extenders. Models: B126-2A1, B126-2A0

User Manual Back-UPS BE650MC

Owner s Manual. VGA Over Cat5 Extender Kits with EDID Copy 2 Local, 2 Remote. Models: B and B A

Owner s Manual. USB to RJ45 Cisco Rollover Cable. Model: U RJ45-X PROTECT YOUR INVESTMENT!

Owner s Manual HDMI Matrix Switch

Owner s Manual. DVI Single Link with Audio Splitter. Models: B A and B A

Owner s Manual. 5200mAh Mobile Power Bank

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Owner s Manual Automatic Voltage Switch

Owner s Manual 2-Port USB to Serial Adapter Cable

Quick Start Guide. Dual USB Wall Charger with PD Charging, (x1) USB-A Port and (x1) USB-C Port. Model: U280-W02-A1C1

Owner s Manual. USB 3.0 Docking Station for Microsoft Surface. Models: U342-GU3, U342-HGU3 PROTECT YOUR INVESTMENT!

Quick Start Guide. Cisco Compatible 10Gbase-LR SFP+ Transceiver with DDM, SMF, 1310 nm, 10 km, LC. Model: N286-10GLR-SLC PROTECT YOUR INVESTMENT!

Owner s Manual. USB Type-C to Serial Adapter Cable. Model: U C. * USB Type-C and USB-C are trademarks of USB Implementers Forum

Owner s Manual. USB 3.1 Gen 1 USB-C to DisplayPort Adapter with Charging. Model: U444-06N-DP-C

Installation and Operation Back-UPS Pro BR700G-TW

Owner s Manual. 4-Port RS-232 Serial PCIe Card with Breakout Cable

1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server

Owner s Manual. HDMI to VGA + Audio Splitter 2-Port. Model: P131-06N-2VA-U

Owner s Manual. USB to Serial Adapter. Model: U DB25 PROTECT YOUR INVESTMENT!

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapter with PD Charging. Models: U444-06N-H4K6WC, U444-06N-H4K6BC

Owner s Manual. Media Converters

Zonit μats TM Users Guide μats1-lv Version 1.2

Owner s Manual. USB Type-C to HDMI, VGA, Gigabit Ethernet and USB-A Hub Adapter. Models: U444-06N-HV4GU (White), U444-06N-HV4GUB (Black)

Broadband CTSP-EM48 Series. Total System Power Electronics Module. User Manual

Owner s Manual. DisplayPort / Mini DisplayPort v1.2 Multi-Stream Transport Hubs

Owner s Manual. Media Converters Models: N SC & N ST

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station, Aluminum. Model: U442-DOCK10-S

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapters

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Owner s Manual. USB 3.1 Gen 1 USB-C to VGA Adapter

Owner s Manual. USB 3.1 Gen 1 USB Type-C to DVI Adapters

Owner s Manual. USB 3.1 Gen 1 USB-C to 4K HDMI Adapter with Ethernet and PD Charging. Model: U444-T6N-H4GUBC

Owner s Manual. DVI USB KVM Switch with Audio. Models: B004-DUA2-K-R, B004-DUA4-K-R

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Quick Start Guide. USB 3.1 Gen 1 to DVI Alternate Mode Adapter. Models: U444-06N-DVI-AM (White), U444-06N-DVIBAM (Black)

Owner s Manual. USB 3.1 Gen 2 (10 Gbps) to Dual SATA Dock/Cloning Station. Model: U CG2. Este manual esta disponible en español en la página de

Owner s Manual. Audio/Video with RS-232 and IR Control over IP Extenders

Owner s Manual. Industrial-Grade USB to RS-422/485 Serial Adapter. Models: U IND (1-Port), U IND (2-Port), U IND (4-Port)

Quick Start Guide. USB 3.1 Gen 1 to DisplayPort Alternate Mode Adapter White. Model: U444-06N-DP-AM, U444-06N-DP-RA (Right Angle)

Owner s Manual. USB Peripheral Sharing Switch

Owner s Manual. DVI over Cat5 Extenders and Extender/Splitters

Quick Start Guide. USB 3.1 Gen 1 to HDMI Alternate Mode Adapter. Models: U444-06N-HD-AM, U444-06N-HDB-AM

Quick Start Guide. USB 2.0 Portable Laptop Crash Cart KVM Adapter Model: B032-VU1

USB-A to Serial Cable

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

Owner s Manual. DisplayPort KVM Switch with Audio and SuperSpeed USB 3.0 Hub. Models: B004-DPUA2-K, B004-DPUA4-K

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station - Silver. Model: U442-DOCK4-S. USB Type-C and USB-C are trademarks of USB Implementers Forum.

Quick Start Guide. KVM Extender USB

USB 3.0 to DisplayPort Adapter. Model #: U DP. USB 3.0 to DVI Adapter. Model #: U R. USB 3.0 to HDMI Adapter. Model #: U HDMI-R

Installation and Operation Back-UPS Pro 900

Owner s Manual. USB 3.1 Gen 1 USB-C Docking Station. Models: U442-DOCK1, U442-DOCK1-B

Installation and Operation Manual Back-UPS BR900G-RS

Register your product and get support at. SPP3038A. User manual

VGA Over Cat5 Extender with Audio

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USB Ranger 110/410 User Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Quick Start Guide. Console Servers

User s Manual Legend SB425 K

Owner s Manual. HDMI over Cat5 Extenders and Extender/Splitters

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

Owner s Manual. Desktop Charging Stations. USB Charging (Model: CSD1006USB) AC Charging with Surge Suppression (Model: CSD1006AC)

LED FOLDING WORKLIGHT TM

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

Owner s Manual. DVI over Cat5 Extenders and Extender/Splitters

Installation and Operation

VIP-480AL IP One-Way Horn

VIP-812A DUAL NETWORKED STATION PORT

USB Port Hub HO

Quick Start Guide. Mini Bluetooth 4.0 (Class 1) USB Adapter. Model: U BT4

VIP-148AL IP Talkback Horn

iconverter 2-Module Power Chassis

Owner s Manual. 1-Port Gigabit Ethernet (GbE) PCI Express (PCIe) Card

MP3 Speaker USER GUIDE

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

USB Ranger 422 User Guide

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Wa r n i n g-wa r n i n g-wa r n i n g

USB Transfer Cable. for Windows and Mac User s Guide

Bluetooth USB Adapter TALUS. User Guide

Innovative Circuit Technology Ltd.

HUBBCOM GSC3000/GSC4000 Flush-Mount Smart Controller Quick Installation Guide

Owner s Manual. USB 3.1 Gen 1 (5 Gbps) to CFast 2.0 Card Reader with SATA III Adapter and Built-in Cable

iq 16 Sync Charge Box

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

3.5 inch Hard Drive Enclosure. Model #: HDE350U. User s Manual

3.5 inch Hard Drive Enclosure. User s Manual

Transcription:

Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004

Introduction Introduction About this unit Redundant power and output voltage monitoring for Broadband cable systems is provided with the use of two APC Automatic Disconnect Switches and two Ferroresonant Power Supplies (FRP). Safety Electrical Warnings Do not work alone under hazardous conditions. High current through conductive materials could cause severe burns. Do not work alone under hazardous conditions. High current through conductive materials could cause severe burns. Do not handle any metallic connector before the power hs been disconnected. When grounding cannot be verified disconnect the equipment from the utility power outlet before installing or connecting to other equipment. Reconnect the power cord only after all connections are made. Check that the power cord(s), plug(s), and socket(s) are in good condition. Replacement of fuses or other parts must be with identical types and ratings. Substitution of nonidentical parts may cause safety and fire hazards. In order to maintain compliance with the EMC directive for products sold in Europe, output cords attached to the UPS should not exceed 10 meters in length. Specifications Environmental Specifications Temperature Operating: 32 to 122 F (0 to 50 C) Storage: 5 to 122 F (-15 to 50 C) Humidity 0 to 95% Elevation 0 to 10,000 feet (0 to 3,000 meters) Broadband Automatic Disconnect Switch User Manual 3

Installation Electrical Specifications Utility Power Cable Input Connection Three Position Terminal Block Cable Adapter (5/8-24) Terminal Block to Coax Center Conductor Nominal Voltage 220 V 63 V Allowable Input range 165-270 V 40-75 V Maximum Current 15 A 18 A Input Current Limiting 10 A N/A Output Connection Allowable Output range Initial Connection Delay Time to connect attached FRP to cable system after output failure Physical Specifications Three Position Terminal Block N/A Cable Adapter (5/8-24) Terminal Block to Coax Center Conductor I 40-75 V Primary - None Secondary - 5.5 seconds 350 ms maximum Characteristic Height/Width/Depth Weight Specification 15 x 7 x 8 (38.1 x 17.8 x 20.3 cm) 14 lbs (6.4 kg) Installation Unpack Read the Safety Guide before installing this unit. The User Manual and Safety Guide are accessible on the APC Web site, www.apc.com. Inspect the unit upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Check the package contents: 4 Broadband Automatic Disconnect Switch User Manual

Automatic Disconnect Switch enclosure Two mounting brackets Four screws One F Connector nut Schematic Overview of the Automatic Disconnect Switch System Installation UPS literature kit containing: product documentation safety information warranty information The user must designate the primary and secondary power supply. Refer to Reset/Test in the Operation section of this manual for details. Primary Power Supply Primary FRP supplying power to two buildings Secondary Power 220 VAC 220 VAC FRP1 CS CS FRP2 63 VAC 63 VAC cable 63 VAC blocking element Power Bulding 1 cable Bulding 2 cable Power 63 VAC blocking element cable Broadband Automatic Disconnect Switch User Manual 5

Installation Mount the Automatic Disconnect Switch on the Wall Do not operate the UPS where there is excessive dust or the temperature or humidity are outside the specified limits. The Automatic Disconnect Switch enclosure has side vents. To ensure adequate air flow in and around the unit there must be 1 (2.5 cm) of space on the right and left sides of the enclosure. Mount the Automatic Disconnect Switch enclosure on the wall using screws appropriate for the weight of the unit and the mounting surface material. Install the Mounting Brackets on the Automatic Disconnect Switch Enclosure When securing the mounting brackets to the enclosure two screws must be used in each bracket. Utility Power Connections Installation must be performed by a qualified electrician. Adhere to all local, state, federal, and/or National Electric Code (NEC) regulations regarding location, permits and electrical wiring. Install an approved 20 A high magnetic circuit breaker on the input side of the Automatic Disconnect Switch. Utility wiring panel with holes for wires Input Hardwire Output Hardwire 6 Broadband Automatic Disconnect Switch User Manual

Hardwire the Automatic Disconnect Switch Installation Step Remove the utility wiring panel located on top of unit. When required apply a strain relief grommet to the utility wiring panel holes. Step Route the building wiring through the holes in the utility wiring panel. Connect the 220 V building wiring to the Input Hardwire terminal block. Step Route the input wiring for the FRP/FLM through the hole in the utility wiring panel. Connect the FRP/FLM input wiring to the Output Hardwire terminal block. Step Reinstall the utility wiring panel. Secure the panel with the screw removed in Step. Broadband Automatic Disconnect Switch User Manual 7

Installation Cable System Connections USB Cable Tie Wrap Lance F Connector USB Connector Cable Modem Utility Power IEC Recepticle Coax Output Coax Input F-Connector Installation 8 Broadband Automatic Disconnect Switch User Manual

Installation Coax Connection Coax Output- Connects to Cable System Coax Input- Connects to FRP Output Broadband Automatic Disconnect Switch User Manual 9

Installation Cable Modem Connection The cable modem utility power, F-connector, and USB connectors are located on the back of the cable modem. Secure the appropriate cables to these connectors before installing the cable modem in the enclosure. USB Cable Tie Wrap Lance F Connector USB Connector Connect the appropriate cables to the cable modem IEC receptacle, the USB port, and the F-connector located on inside the enclosure. Using the lance on the enclosure secure a tie wrap to the USB cable if required. Lo cal Po wer Rem ote Power Cable Modem Utility Power IEC Recepticle 10 Broadband Automatic Disconnect Switch User Manual

Operation Start Up Primary/Secondary Access Panel To remove the access panel covering the Primary/Secondary Select button remove the screw that secures the panel to the enclosure. Slide the access panel slightly to the right and then pull the access panel toward you. Operation Indicators and Controls Local Power Remote Power Circuit Breaker Local Power Remote Power Reset/Test Local 63V Fault Reset/Test Local 63V Fault Primary/ Secondary Select Primary Secondary 220V Normal Primary/ Secondary Select Primary Secondary 220V Normal Circuit Breaker: The circuit breaker protects the 220 V input from overload conditions. Local Power: Green LED indicates that the Automatic Disconnect Switch is providing power to the cable system. Remote Power: Green LED indicates the cable system is receiving power from a source other than the Automatic Disconnect Switch. Broadband Automatic Disconnect Switch User Manual 11

Operation Reset/Test: Functionality of this control is dependant upon Automatic Disconnect Switch status. Primary Status The primary Automatic Disconnect Switch is supplying power to the cable system. The Local Power LED will be illuminated. The Reset/Test button will do nothing. When the primary Automatic Disconnect Switch is not supplying power to the cable system the Remote Power LED will be illuminated. The Automatic Disconnect Switch will perform a test to measure the output voltage from the local FRP. Secondary Status The secondary Automatic Disconnect Switch is supplying power to the cable system. The Local Power LED will be illuminated. The secondary Automatic Disconnect Switch will momentarily disconnect the local power from the cable system allowing the primary system to supply power. If the primary system begins to supply power, the secondary system will remain disconnected. If the primary system fails to supply power, the secondary system will immediately begin supplying power to the cable system. When the secondary Automatic Disconnect Switch is not supplying power to the cable system the Remote Power LED will be illuminated. The Automatic Disconnect Switch will perform a test to measure the output voltage from the local FRP. Local 63 V Fault: Green LED indicates: The FRP/FLM output is outside the specified range during a test. The output failed while the Automatic Disconnect Switch was supplying power. Primary/Secondary Select: This control is used to establish the Automatic Disconnect Switch as the primary or secondary power source for the cable system. Primary: Green LED indicates that the Automatic Disconnect Switch is the primary power source. Secondary: Green LED indicates that the Automatic Disconnect Switch is the secondary power source. 220 V Normal: Green LED indicates that 220 V input is present and within specified limits. Cable Modem The cable modem functions only when power is supplied by the Automatic Disconnect Switch to an FRP. If the FRP fails the cable modem will continue to function. 12 Broadband Automatic Disconnect Switch User Manual

Troubleshooting, Service, Contact, Warranty and Regulatory Information Troubleshooting, Service, Contact, Warranty and Regulatory Information Troubleshooting Use this chart to solve minor installation and operation problems. Refer to the APC Web, site www.apc.com with complex problems. Problem and/or Possible Cause Solution Unit is on and the 220 V Normal LED is not illuminated The unit is not wired properly. The circuit breaker is tripped. The 220 V power is outside the specified limits. Check that the input and output wiring are not reversed. Reset the circuit breaker. Check that the 220 V power is within specified limits. Refer to Specifications in this manual. Unit is on and the Local 63 V Fault LED is illuminated The unit is not connecting power to the cable system. Check that the coax connections are not reversed. Check that the FRP/FLM output is within specified limits. Refer to Specifications in this manual. Secondary unit will not switch to Remote power when the Test button is pressed Remote power system is not functioning. This is normal operation. Verify that the Remote power system is working. Primary unit is indicating Remote power Primary unit was powered up after the secondary unit. This is normal operation. Press the Reset button on the secondary unit to transfer power to the primary unit. Limited Warranty The primary FRP/FLM output is not within specified limits. Refer to Specifications in this manual. American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. Broadband Automatic Disconnect Switch User Manual 13

Troubleshooting, Service, Contact, Warranty and Regulatory Information Service If the unit requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in Troubleshooting to eliminate common problems. 2. If the problem persists, contact APC Customer Support through the APC Web site, www.apc.com. Note the model number of the unit, the serial number, and the date purchased. If you call APC Customer Support, a technician will ask you to describe the problem and attempt to solve it over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#). If the unit is under warranty, repairs are free. Procedures for servicing or returning products may vary internationally. Refer to the APC Web site for country specific instructions. 3. Pack the unit in its original packaging. If this is not available, refer to the APC Web site for information about obtaining a new set. Pack the UPS properly to avoid damage in transit. Never use Styrofoam beads for packaging. Damage sustained in transit is not covered under warranty. 4. Mark the RMA# on the outside of the package. Return the unit by insured, prepaid carrier to the address given to you by Customer Support. Contact APC Refer to the APC Web site, www.apc.com. Select the appropriate country from the country selection field, and select the Support tab at the top of the web page. Regulatory Agency Approvals and Radio Frequency Warnings FCC Compliance Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense. LISTED 42C2 E95463 Entire contents copyright 2004 by American Power Conversion Corporation. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, Smart-UPS, and PowerChute are registered trademarks of American Power Conversion Corporation. All other trademarks are the property of their respective owners. 14 Broadband Automatic Disconnect Switch User Manual