ZC Series Zone Monitoring Controllers

Similar documents
APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

PRSU/5 Safety Interface Controller

Installation and Wiring

MAXIMA + Series ROTARY LEVEL CONTROL

Safety Control Relay Product Catalog

EM-F-7G Safety Extension Module

5504 Thermocouple Analog Input Module

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MAXIMA+ Series Rotary Level Indicator

Instruction Sheet Board Style Low Water Cutoff

Quick Start Guide TS A

PV Rapid Shutdown device

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

Installation Instructions

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

INSTALLATION INSTRUCTIONS

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

UT Martin Environmental Health & Safety Safety Procedure

SED2 Variable Frequency Drives

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.

Source-Transfer Application Guide

MAXIMA + Series ROTARY LEVEL CONTROL

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

PS/IO Circuit Board Retrofit

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Safety Mats & Area Guarding

Operating Instructions. For. Level Control Module. Model SSR 1000

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

AD-7830 Servo Amplifier

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Expandable Power Systems

BCM2 Series Branch Circuit Monitors Quick Setup Guide

NETRONICS HS3500 CONTROLLER

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Solar Combiner Enclosure

Making Hazardous Operations Safe and Productive

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Basketball Shot Clock Set LX2180 Manual

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

SMVector Additional I/O Module Installation and Operation Manual

PSSU/A2 Control Unit Installation Instructions

KTD-125/ KTD-125P/125P-24 KTD-127/127W PTZ Receivers

Electrical Demand Specification (Reference SOP: )

Universal Safety Photo Eye UL MONITORED DEVICE

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Model HM-535 Power Supply Installation and Service Instructions

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Primary Injection Test Procedure

LC3 LIGHTING CONTROLLER OPERATIONS & MAINTENANCE MANUAL 2013 Dec

Installation Manual for D244X Series 24-volt Power Supplies

Instruction Manual: IM E

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Brasch Washdown Unit Heaters

Regenerative Power Module And Common Bus RPM Panels Instruction Manual

Resolver to Digital Expansion Board

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Machine Safety Switches

ALTERNATING RELAYS & CONTROLLERS ARM Series

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

ES-TN-1H.. E-Stop Safety Modules with Fixed Delay

Elevator Systems Inc. TEERS Traction Elevator Emergency Return System

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

R147 WIRELESS ANTI-TWO-BLOCK INDICATOR

ORB TM 4-20 ma Input Box Installation & Operation Manual

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

5401 and 5402 Digital I/O Modules

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

SMS 4 / SMS 5 safety mat Product information

Level-Lance Model 5400A

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

SMART SHOT CONTROLLER FLUID USERS GUIDE

Table of Contents. Safety. Attention. Warnings

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

PS8 - II. Professional Power Sequencer. User s Manual

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

SAVE THESE INSTRUCTIONS

Magnetically Actuated Safety Interlock Switches

ICM 400. Three Phase Voltage Monitor with Reset Switch. Low cost line voltage protection for 3-phase motor systems

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

Transcription:

ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423 ZC-4 4 Zone Controller 0424 AUTO Reset Controllers ZCA-1 1 Zone Controller 0431 ZCA-2 2 Zone Controller 0432 ZCA-3 3 Zone Controller 0433 ZCA-4 4 Zone Controller 0434 100 Schmitt Boulevard 1 Fax: 631-630-0454

CONTENTS Page 1. INTRODUCTION 2 2. PRINCIPLES 3 ZONE SENSING RESET LOGIC OUTPUT CONTACTOR 3. APPLICATIONS 4 4. INSTALLATION 5 5. OPERATIONS 6 BASIC OPERATION DAILY TESTING SHUTDOWN LOCKOUT OR TAGOUT 6. SERVICING 6 TROUBLESHOOTING PARTS REPLACEMENT INFORMATION TECHNICAL SPECIFICATION AUTO Reset models are NOT to be used for primary safety applications. See additional cautions inside this manual. Improper application of an AUTO Reset controller may result in death or serious injury to personnel. 1. INTRODUCTION Tapeswitch ZC Series zone controllers are versatile, easy to install electrical controls, made for industrial applications and duty. They simplify the interfacing of conventional sensing switches to industrial systems. Tapeswitch controllers feature: - Low voltage DC sensing circuits. - One, Two, Three, or Four independent sensing zones for monitoring multiple sensing switches. - Continuous, independent zone monitoring; no scanning. - Multi-sensor interfacing - NO (Normally Open), NC (Normally Closed), and supervised FAIL-SAFE (four wire) sensing contacts can all be used. - Individual zone indicators for easy troubleshooting. - Hefty load contactor, up to 25 amps. Handles industrial voltages, up to 600V AC. - Single Phase or Three Phase load capability. - A complete, pre-wired package, ready for use in a heavy steel enclosure. National Electrical Manufacturers Association (NEMA 12). Tapeswitch controllers are ideal for use with Tapeswitch ControlMats, Armor Mats, Diamond Plate Mats, CVP style Control Mats, Controflex ribbon switches, or Tapeswitch sensing edges. These sensors are frequently in contact with the ground, or are manually actuated. The controller provides 24 Vdc for sensor operation, which is considered non-hazardous in accordance with the National Electrical Code (NEC), and there are no Radio Frequency Interference (RFI) or capacitive coupling problems with direct current. FAIL-SAFE supervision is an additional feature of Tapeswitch zone controllers. When properly connected to a FAIL-SAFE Switch, the load contactor will de-energize on loss of power to the controller, activation of the sensor, a short in the sensor or sensor wiring or a break (open) of the sensor or sensor wiring. 100 Schmitt Boulevard 2 Fax: 631-630-0454

2. PRINCIPLES The basic function of these controllers is to turn off or on a single powerful machine in response to low power, low voltage inputs. One load circuit is controlled, based on sensing switches connected to the different zone inputs. Depending on the model selected, there may be one, two, three, or four independent input zones. A RESET input will re-energize the machine after a fault is removed. Two versions of each model are available, depending on the application. In the Manual reset model, a specific reset signal is needed to initiate output. In the AUTO reset model, no signal is needed, and an output is initiated whenever all zones are fault-free. Figure 1 shows a four zone, manual reset model. (and the controller will trip) upon any of the following conditions: - Loss of power to the controller - Activation of the switch in that zone - A short in the sensor or sensor wiring for that zone - A break (open) of the sensor or sensor wiring for that zone RESET LOGIC The reset logic acts to energize and de-energize the output contactor. The reset logic continuously checks zone status, and the reset command signal. When all zones are clear and fault-free, and the reset signal is received, the contactor is energized. In a manual system, there must be a separate reset signal, usually from the front panel push button. An AUTO Reset Model requires no separate signal, and resets whenever the zones are clear and fault-free. Both the reset logic, and zone monitoring logic components are located on the 'Zone PCB' inside the cabinet. Figure 2 shows the typical layout of the inside of a four zone controller. Figure 1 Front Panel of manual reset ZC-4 All models of the ZC Series controllers are packaged in a NEMA 12 wall-mount enclosure. Mounted internally on the enclosure door is an LED circuit board which holds the indicating lamps. In the main part of the enclosure, a subpanel holds the main or 'zone' printed circuit board, power transformer, and output contactor. Figure 2 shows the internal arrangement of a ZC-4. Zone controller operation is divided into three functions: zone status monitoring, reset logic, and output contactor operation. ZONE SENSING Zone sensing takes place continuously. Each zone is independently monitored by a low-voltage DC current loop circuit. When the zone is clear and fault-free, the zone status light is green. However, a red status light will show Figure 2 - Internal Arrangement of a ZC-4 Because an AUTO Reset controller causes the output action without further operator involvement, it is ideal for machine automation. For example, a typical application uses an industrial duty ControlMat to open a small door on a reheating furnace. A worker carries a part to the furnace using two handed tongs. The door opens automatically when the worker steps on the mat. Operator safety is not involved. 100 Schmitt Boulevard 3 Fax: 631-630-0454

When safety is involved, only the manual reset controller should be used. Machine operation based on operator presence-sensing is a dangerous application, forbidden by OSHA in most instances. An example of a dangerous AUTO Reset application would be a safety mat used in front of an NC punch press. The mat only causes the press to halt while the operator is on the mat. One worker was injured when he stepped off a mat, onto the bed of a press to clear a jam. When the jam cleared, the bed continued its movement, pinning the worker. If the control had been Manual Reset, the accident would not have occurred. Figure 3- Connecting a Tapeswitch FAILSAFE sensor Do not use an AUTO Reset control in a safety application. Serious death or injury may result, particularly during unexpected operations or during maintenance. OUTPUT CONTACTOR Each ZC Series controller houses a small, high-power contactor, suitable for switching machine loads up to about 1.5 HP. The output contactor is designed to handle a single machine load. It is located on the lower left of the main internal panel, as shown in Figure 2. Figure 4 - Connecting an NO switch 3. APPLICATIONS Section Two of this manual discusses the primary safety considerations in selecting a Manual or Auto Reset controller. Be sure you are familiar with the concepts presented before applying a controller to a specific machine. The ZC Series controllers let you configure a sophisticated array of sensors to control a single machine. When multiple sensors are used, a frequent problem is the difficulty in troubleshooting even a simple fault. Dividing the sensors into zones and monitoring each zone independently, greatly reduces downtime and troubleshooting. The ZC Series provides 1 to 4 independent zones. For custom systems with even more zones, contact TAPESWITCH. Each sensing zone may be connected in any of three different wiring arrangements. A NO contact, a NC contact, or a four wire FAIL-SAFE switch may be connected to each zone. Figures 3, 4, and 5 show the specific configuration to use when connecting each type of sensor. Figure 5 Connecting an NC switch Connecting multiple sensors on a single channel makes troubleshooting more difficult and for that reason is NOT recommended. TAPESWITCH recommends that no more than two mat type sensors ever be used for a single zone. Never bypass or disconnect a zone. Troubleshoot the system by substituting components. If more, or fewer, zones are needed, install a Tapeswitch controller with the correct number of zones. All channels are configured for FAIL-SAFE operation as shipped. (User-supplied jumpers must be used to reconfigure for other contact types). Note that the NO connection is not supervised and should be avoided in some applications. 100 Schmitt Boulevard 4 Fax: 631-630-0454

CAUTION Consult the technical data for each sensor being used to determine maximum units in a configuration, operating limitations and other requirements. Observe the polarity shown. This means that terminals 1 & 4 and 2 & 3 respectively must be connected to the same continuous conductor. Tapeswitch FAIL-SAFE sensing switches are coded to indicate polarity. The load contactor has both NO and NC contacts. It can be used to switch both legs of a single phase load. It is recommended that both legs be switched. A three phase load contactor is optionally available. NEVER switch the electrical ground. Never switch only the neutral on a single phase load. Some particularly hazardous equipment, such as power presses, require specific levels of reliability, even when a fault occurs to the controller. Be sure to check applicable ANSI and OSHA documents for specific requirements. Tapeswitch ZC and ZCA controllers are not single-fault-tolerant. Contact Tapeswitch for information on multizone, multi-channel controllers. TAPESWITCH ControlMats, ArmorMats, and other sensing devices are color-coded to show polarity. Figure 6 shows typical color coding for a Control Mat. 4. INSTALLATION When used to guard a hazardous location, the controller must be a manual reset type, and be located in a safe area, away from any hazards being guarded. This is common sense. The operator should never be able to re-energize the controls while in a hazard area. If the controller is best located in a hazard area, then disconnect the front panel RESET switch internally, cut off the connector, and substitute a NO push button switch which is located in a safe area. Use terminals 701 and 702 on the PC board. These industrial controllers are designed for permanent hard-wired installation. They must be securely mounted. (There are predetermined locations for mounting hardware on the rear of the controller). Mounting brackets are standard with each controller. The enclosure is rated NEMA 12, which means dust and water resistant. This is suitable for most indoor locations. All supply, zone sensing, and load wiring must be in accordance with the NEC. Refer to the Technical Specifications (Section 2) for data on permissible loads. CAUTION: Observe the NEC when wiring Tapeswitch controllers, specifically Articles 300 and 310. Be sure that all wiring is properly sized for the load by referring to Table 310-17. Be sure to connect the supply voltage to the contactor common terminals and the load to the NO or NC terminals. Failure to adhere to the NEC may result in serious fire or injury. High Voltage - Electrocution Hazard. Live power may be present on the transformer. Be sure that the unit is voltage-free before installing or servicing. Power (120 or 240 Vac) must be supplied to the controller. Connect incoming power to the high voltage side of the transformer. See Figure 2, and the diagram on the side of the transformer. Power requirements are low, usually much less than the 20 VA specified. If a 120 Vac load is to be connected directly to the controller, insure that supply wiring is properly sized to supply both load and controller. CAUTION Never try to convert a Manual RESET controller to AUTO Reset operation. Damage to the controller will result. Figure 6 Typical color code for ControlMats For 120 Vac operation, connect H1 to H3, and connect H2 to H4 on the transformer. For 240 Vac operation, connect H2 to H3 only. 100 Schmitt Boulevard 5 Fax: 631-630-0454

5. OPERATIONS CAUTION: Be sure the controller has been properly connected before attempting to operate the unit. BASIC OPERATION START UP: Turn on the power. The green power lamp should light. All red indicator lamps should come on and remain lit. This indicates that the zones have not been RESET. (The AUTO reset version may switch from red to green). MANUAL RESET: Push the red RESET button. All red and green lamps should come on and remain on until the button is released. If any lamp does not come on, it indicates a defective lamp or control channel. If the zone switches are fault-free, the load contactor will energize with a sound easily heard outside the cabinet. Release the red RESET button. The red lamps will go out and the green lamps will remain on for all zones with faultfree sensing circuits. If any zone is not clear, its red lamp will stay lit, and the load contactor will not energize. DAILY TESTING Upon startup each day and prior to resetting the controller, test the lamps, and test each zone by actuating the appropriate sensing switch. On an AUTO reset model, do not energize the load until the zones have been tested. LAMP TEST: Press the red RESET button at any time to test the lamps. All lamps should light. NOTE: This will not affect the state of an energized load contactor. (For auto reset, activate each zone separately to test). SHUTDOWN Simply turn off power to the Tapeswitch controller. The load contactor will de-energize. The load contactor can also be de-energized by activating one of the zone sensing switches. 6. SERVICING TROUBLESHOOTING The following steps will usually isolate any problems in a ZC Series zone controller system: - De-energize the load until the controller has been checked out. - Check that all wiring is secure and proper. - Energize the controller only. Check for 120/240 VAC to HIGH VOLTAGE terminals. Be sure connections are correct! - Check that a lamp comes on in each zone when power comes on. If none light, the power transformer, or rectifier, may be defective, or there may be loose internal wiring. - If only a few zones show lights at power on, it indicates problems in the zones which show no lamp. The controller s logic board should be replaced. - Manual reset only. If, at power on, all lamps light and the load contactor energizes, it indicates a short on the RESET lines, which must be located and corrected! Operation with a continuously closed RESET circuit will damage the controller. - Check the sensor wiring by pushing and releasing the RESET button. The red lamps should all go out, and the load contactors should energize. If some zones will not reset, check the sensors on these zones. If necessary, disconnect sensor wires, and install a known good FAIL-SAFE four wire switch. If the zone still fails to RESET, it indicates a defective zone relay, which may be tested by exchanging controller s logic boards. LOCKOUT OR TAGOUT OSHA regulations (29CFR Part 1910.147). The control of Hazardous Energy (lockout/tagout) final rule will be enforced on or after January 2, 1990. This standard requires employers to develop and utilize an energy control program to prevent the unexpected energization or start up of machines and equipment during service and maintenance operation. Formal employee training and written documentation is required. There is no provision for lockout at this controller. 100 Schmitt Boulevard 6 Fax: 631-630-0454

PARTS REPLACEMENT INFORMATION TECHNICAL SPECIFICATION Part Description Model Part Nr. LED Circuit Board (AUTO Reset uses the same part as the manual reset listed here) Zone Circuit Board, Manual Reset models Zone Circuit Board, AUTO Reset models ZC-1 13488 ZC-2 13489 ZC-3 13490 ZC-4 13491 ZC-1 13473 ZC-2 13463 ZC-3 13464 ZC-4 13462 ZCA-1 ZCA-2 ZCA-3 ZCA-4 Main contactor All 11001 Transformer All 11016 Replacement parts, additional controllers, and technical assistance are all available through Tapeswitch, and through industrial automation distributors throughout North America, Europe, and Asia. Contact Tapeswitch for the name of the sales group nearest to you. ITEM RATING UNITS Power Required Enclosure NEMA 12 Color Sensor Voltage Load Capacity Reset Signal 120 or 240 VAC 50/60 Hz 20 VA Beige 24 VDC 10 Amp @ 600 VAC, max non-inductive 12 Amp @ 480 VAC, mzx non-inductive 25 Amp @ 117 VAC, max non-inductive 2 HP motor @ 120-600 VAC maximum NO to NC to NO contact, manual reset models only Figure 7 ZC Series Dimensions 100 Schmitt Boulevard 7 Fax: 631-630-0454