PANEL DIGITAL READOUT ABSOLUTE/RELATIVE DISPLAY INPUT BY POTENTIOMETER 2 RELAY OUTPUTS

Similar documents
CM78N C-01 Operating Manual CONFIGURING INSTRUCTIONS

Displays Transducers. Displays and transducers

IPM650 Intelligent Panel-Mount Display

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Universal counter UZ 9648 Counting - length measurement - metering - positioning

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Operating instructions only for authorized, skilled electricians with EIB training

7561-PSD Manual Portable Battery Powered Indicator

Power System Protection Laboratory Electric Power and Energy Engineering

Display and Monitoing Units

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

407B 1/16 DIN Multi-Mode Timer

405A Timer with Instantaneous Relay

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

EM2020 Selectable AC transducer A (UK)

02/11/2015

signo 727 SSI operating instructions

Standard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY

Tempco Instruction Manual

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Pen Drive USB Datalogger!

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

MOD. KBC HEAD KONTAX BATCH CONTROLLER

CONTA-ELECTRONICS CMS Multi-function Multi-channel converter

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com

MobilControl MC 4000 OWNER S MANUAL

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

NF760 Batch Controller

Contents. Temperature & Process Measurement Indicators Setup Guide

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

Omni + User Manual. Dual Setpoint Temperature Controller with Programmable Input & TIMER. Omni 96+ Omni 72+ Omni 48+ TMR TMR TMR

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller.

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Technical specifications

NFC110. Flow Computer For Low Pulses FEATURES

BMX DDM Mixed Relay Input/Output module

Control instruments GUARDIAN 2 - GUARDIAN 3

Microcontroller Based Temperature/Process Scanner (Product Code 7.4 to 7.6) MSI-804 with 16 relays

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Speed Controller ZSU A01

Electronic SD1, AS 8, ASR 14, ASR 20

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

EDX-10 Series. Compact Recording System

GIR 230 TC Version 1.1

10 DIGITAL MICRO-PROCESS TOTALIZER METER with ALARMS / ANALOG OUTPUT / PULSE OUTPUT / RS-485. T Total Alarm x 1 + FRONT PANEL & KEY FUNCTIONS

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

Modular Panel Meter Series EDM 35

Unipower HPL600. Unipower HPL600

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

MODEL SELECTION SINGLE-PHASE, TWO-WIRE (ONE-ELEMENT) MODELS WITH INTERNAL CURRENT SENSOR

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

GIR 230 FR Version 1.1

MICROPROCESSOR BATCH CONTROLLER MOD.DOSAX

Analog Output Isolators

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

02/11/2015

user and installation manual

EDX-10 Series. Compact Recording System

Peak/Valley Hold Unit (PVHU) User Manual V3.00

Instruction Manual IUC-79-FTF 0-10 VDC. Thresholds: ON: TP1=3V OFF: TP2=1V ON: TP1= OFF: TP2= 100 microsec. Not Installed

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

RS485 (S85- -Y13) Display (S85- -Y13) Setting push-buttons (S85- -Y03) Power supply Vdc 24 V +/- 20% PNP NPN Output Push pull

Process Indicator Controller (Digital) (Product code 3.1 to 3.15)

SEQUENCER FOR DEDUSTING PLANTS

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

SI3300. user and installation manual. 4-20mA/DC-Digital Display

Installation & Operation

Microcontroller Based 8 CHANNEL Temperature/Process DATA LOGGER (Product Code 8.7 to 8.9)

AX 345 and AX 347 Process Indicators with Two Analogue Inputs and Calculations

GFC114. Low Power Flow Computer FEATURES

UNIVERSAL CURRENT CONVERTER

Transducers for Pt-100/1000, Resistors

3500/53 Electronic Overspeed Detection System

Available for low voltage and high current High slew rate with 100A/μs

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

masibus : UT-94 Page 1 of 6 INTRODUCTION SPECIFICATIONS Dimensions Document Ref No. m98a/om/101 Issue No: 08

Process displays For current and voltage

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

DIGITAL DISPLAY. for Industry Applications. Serie REX-D. Key-Features:

Guide Specification for 3G Wireless Battery Monitoring System

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Transcription:

VD4 LQ2R PANEL DIGITAL READOUT ABSOLUTE/RELATIVE DISPLAY INPUT BY POTENTIOMETER 2 RELAY OUTPUTS Digital readouts series VD4 LQ can be coupled to linear and rotary potentiometers with resistive value ranging between 1 and 20 Kohm. The value of the displayed magnitude can be adjusted between 9999 and 9999. In case of values beneath 999 the minus sign is indicated by a dot placed on the right side of the less significative digit. The default display mode is absolute. The absolute/relative display mode can be enabled by the menu SETUP (selecting mode: REL). OPERATING DESCRIPTION At power on the instrument displays the software version identification for one second: P-XX-, where XX is the number of the loaded software; afterwards the displays switches to the main display page. VALUES PRESELECTION Press the key DOWN ARROW to switch from the main display page to preset 1 entering; the display will show OUT1: use the ARROW KEYS to enter the value and press the key F to confirm. Press the key UP ARROW to enter preset 2; the display will show OUT2: use the ARROW KEYS to enter the value and press the key F to confirm. The outputs operating mode depends on the settings entered in the SETUP phase. The comparing value for the thresholds enabling is the value displayed in the main page. SET VALUE LOADING (for mode selection: REL) Press the key F for one second to switch from the main display page to the set value loading; the display will show the flashing message LOAD. Press the DOWN ARROW key to load the set value; any other key cancels the operation. This operation sets the display value at the LOAD value entered in the SETUP menu, thus switching to the relative display mode. The relative mode is kept even in case of instrument switching off. SWITCHING BACK TO THE ABSOLUTE DISPLAY MODE (For selection mode: REL only) From the main display page, press the key F for three seconds: the display will show: SET. Switching back to the main display resets the display ranges set in the starting adjusting, thus the obtained reading is absolute. The operation cannot be cancelled. Press the key F five-folds to switch back to the main display page. KEYS FUNCTION DOWN ARROW decreases the value UP ARROW increases the value F stores the value and quits the setting TECHNICAL SPECIFICATIONS: Supply 24 Vac or 115/230 Vac ±10% 50/60 Hz 12/24Vdc ±10%* (see the supply label) Power consumption 4 VA max (version 24/115/230 Vac) 2.5 Watt (version 12Vdc) 5 Watt (version 24Vdc) Display type Data and preset storing Display range -9999 / 9999 Decimal digits settable: 0, 1,2 or 3 Operating temperature 0 45 C 4-digit 7-segment LED display 12.7 mm high on FLASH memory Panel cut off 91 x 44 mm Transducer supply voltage provided by the 5Vdc 5mA max instrument Input specifications resolution 4000 steps, accuracy 0.2% full scale range Relay contact type NA, 3A, 250 Vac A/D conversion 140 per sec. Relay lag time 35 ms Front case protection degree IP54 *Remark: In case of direct current supply the negative pole of the supply voltage (terminal 1) is connected to O Vdc of the input circuit (terminal 7). VD4lq2r_n0104.doc 19/07/2004 page 1/3

SETUP PHASE The SETUP phase is accessed by the following key sequence: press the key F for 3 seconds and, when the display shows: SET, enter the following access key: UP ARROW, F, UP ARROW, UP ARROW, F. If the access key is not entered within 10 seconds the instrument switches back to the main display page. The SETUP menu includes the following items, which can be scrolled down by the key F: tar (Adjusting) Default: 0 / 4000 n.dec (Decimal digits) Default: 0 AbS/rEL (Absolute/relative display mode) Default: AbS LOAD (LOAD value**) Default: 0 C=XX (Outputs operating mode) Default: 00 ist. (Hysteresis) Default: 5 t. 1 (Output time 1*) Default: 0.5 S t. 2 (Output time 2*) Default: 0.5 S L.inF. (Min. settable value) Default: min. adjusting L.SuP. (Max. settable value) Default: max. adjusting *For pulse outputs only **In case of relative display mode only ADJUSTING PHASE The adjusting phase allows to set the min. and max. values that must be displayed according to the respective positions of the input potentiometer. Press one of the ARROW KEYS when the display shows TAR; the message LO (zero adjusting) will be shown. Now it is necessary to position the potentiometer at the stroke starting point and set the wished value by means of the ARROW KEYS, then confirm the setting by the key F. Following the display will show Hi (max value adjusting): place the potentiometer at the stroke ending and set the wished value by means of the ARROW KEYS, then confirm the value by the key F and switch to the next setting. In case the adjusting operation fails, the display will show Er.tA (adjusting error). In this case it is advisable to check that the value set as max. is greater than the min.setting, and that connections are correct. In case the values previously entered as preselections exceed the adjusting limit values, the preselection value is replaced with the min.adusting value. DECIMAL DIGITS SETTING When the display shows n.dec (number of decimal digits) press the DOWN ARROW key sequentially to scroll 0, 1, 2, 3 decimal digit. Press the key F to store the choice. ABSOLUTE/RELATIVE DISPLAY MODE When the display shows AbS (absolute mode) press the DOWN ARROW key to switch to rel (relative mode) and vice-versa. Press the key F to store the choice. LOAD (for display mode rel only) It is the value at which the display value is set after the LOAD setting operation. When the display shows LOAD press the ARROW Settable values: -9999 to 9999. VD4lq2r_n0104.doc 19/07/2004 page 2/3

OUTPUTS MODE SETTING In this phase it is determined the operating way of the outputs relative to preselections OUT1 and OUT2. The display shows: C=XX Mode OUT1 Mode OUT2 Where X indicates the operating mode as follows: X=0 Steady output for measure Preselection X=1 Steady output for measure Preselection X=2 Pulse output for measure Preselection X=3 Pulse output for measure Preselection The key DOWN ARROW modifies OUT 1 mode The key DOWN ARROW modifies OUT 2 mode The key F stores the set and switches to the hysteresis set phase. HYSTERESIS SETTING When the display shows ist. press the ARROW Settable values: 0 to 1000. It is advisable to set the value in order to prevent possible waverings of the outputs when approaching the preselection values. PRESELECTION MAX.LIMIT SETTING This operation limits the max.value that can be entered as preselection. When the display shows L.SuP. press the ARROW Settable values: -9999 a 9999. OUTPUTS TIME SETTING In case of operation with pulse outputs, their excitation time is set as follows: When the display shows t.x, where X is 1 or 2 according to the referred output, press the ARROW Time is expressed in seconds, settable values are 0.1 to 25.0 seconds. PRESELECTION MIN.LIMIT SETTING This operation limits the min.value that can be entered as preselection. When the display shows L.InF. press the ARROW Settable values: -9999 a 9999. VD4lq2r_n0104.doc 19/07/2004 page 3/3