TIM 3V- IE ADVANCED. Function

Similar documents
SINAUT ST7 station control system SIMATIC NET. Industrial Remote Communication - TeleControl SINAUT ST7 station control system.

TIM DNP3 SIMATIC NET. Industrial Remote Communication - Telecontrol TIM DNP3. Preface. Uses and properties of the TIM

CP ADVANCED. Function

CP BACNET Function

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214NET PG (214-2BT13)

CPU 412H. Function. Parameterizable properties

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

SIMATIC NET. S TeleControl TIM 1531 IRC. Preface. Application and functions 1. LEDs, connectors, switches, card slot 2

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage

General information. Supply voltage. Input current

Data sheet CC 03, Commander Compact (603-1CC21)

Product type designation. General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current. Power losses

Product type designation. General information. Supply voltage. Input current. Power loss

Product type designation. General information. Supply voltage

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

General information. Supply voltage. Input current

SIPLUS CPU 313C-2DP. Function

Supplementary Components WirelessHART products

IE/PB LINK PN IO. PROFINET applications

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

PAS 300, PROFIBUS Slave Interface Module

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS

Data sheet CPU 115 (115-6BL02)

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Data sheet VIPA CPU 115DP (115-6BL22)

Data sheet VIPA CPU M13C (M13-CCF0000)

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

Siemens AG Industrial Remote Communication. Telecontrol. Efficient Telecontrol Solutions. Edition 11/2017. Brochure. siemens.

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Structure and Function

General information. Display. Control elements. Supply voltage

Product type designation

CPU 412. Function. Programmable properties

PSI-GPRS/GSM-MODEM/RS232-QB

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 015PN (015-CEFPR01)

General information. Display. Control elements. Supply voltage

Supply voltage. Input current. Encoder supply. Memory

General information. Configuration control. Display. Control elements. Supply voltage

Data sheet CPU 315SB/DPM (315-2AG12)

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

EN-4000 Hardware Description and Specifications

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

Data sheet CPU 315SN/NET (315-4NE12)

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Data sheet CPU 315SN/NET (315-4NE12)

TeleService of a S station via mobile network

Quick Installation Guide

TG Technical specifications

Data sheet CPU 315SN/PN ECO (315-4PN33)

Fieldbus slave modules w/o I/Os

Supplementary Components Network transitions

Accessories / 7XV5820

S7-400, M7-400 Programmable Controllers

Applications & Tools. SINAUT ST7 Telecontrol Configuration in a safe Internet/ GPRS Connection via MSC Protocol

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Data sheet CPU 015PN (015-CEFPR00)

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Remote networks. Easy remote access to machines and plants. Industrial Remote Communication. Edition 03/2017. Brochure. siemens.com/remote-networks

Internet az automatizálásban Felügyelet és kezelés

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

PA ROUTERS. The following criteria can be applied when choosing the network transition:

Applikationen & Tools. Application for SINAUT ST7 Telecontrol with TIM4R-IE and TIM3V-IE in an Ethernet-based Environment

General information. Display. Supply voltage. Input current

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current

Data sheet CPU 013C (013-CCF0R00)

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

Computer Communications and Network Basics p. 1 Overview of Computer Communications and Networking p. 2 What Does Computer Communications and

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Transcription:

TIM 3V- IE ADVANCED Function The TIM 3V-IE Advanced enables one or more SIMATIC S7-300 or control center PCs (e.g. SINAUT ST7cc or ST7sc) to exchange data with other SINAUT ST7 or ST1 stations via any one or two SINAUT networks. The two networks can also be operated in redundant combination. The important SINAUT property - saving data complete with a time stamp on the TIM in the event of an interrupted link or failure of the partner - is then available not only for conventional WANs, but also for IP-based networks. Important events, alarms, etc. are not lost and the integrity of information in control center system archives is assured. For setting up more complex control centers or node stations, several TIM 3V-IE Advanced modules can be used for each S7-300. A combination with additional TIM 3 and TIM 4 versions in the same rack is possible here. SINAUT ST7 and thus also the TIM 3V-IE Advanced are designed for data transmission via the widest range of WANs or combinations of WANs. Mixed networks comprising classical SINAUT WAN networks (dedicated line, wireless, dial-up network) and IP-based networks (fiber optic, DSL, GPRS, Internet etc.) can be configured uniformly using SINAUT, which saves both time and money. Page 1462 Mar 2008 Siemens ITS

For communication via the Internet, the integrated MSC-VPN tunnel protocol for direct access to DSL routers can be used (MSC client). For communication via GPRS, either the router MD741-1 can be connected to the IE interface (VPN IPsec) or the GSM/GPRS modem MD720-3 (MSC-VPN) to the RS232 interface. PG communication is possible parallel to data communication at any time Several TIM 3V-IE Advanced can be used per S7-300 Message frame memory for up to 32000 data message frames Up to twenty S7 connections via IP-based networks Controllable communication modules: Control of the GSM/GPRS modems MD720-3 in GSM or GPRS mode. In the GPRS mode, simple 128-bit encryption via the MD720-3 (MSC-VPN tunnel protocol) Operation via SIMATIC NET Ethernet components with high IPsec security standard (e.g. GPRS router or SCALANCE S) Direct operation on a DSL router by means of MSC tunnel protocol Use of SCALANCE fiber-optic switches for spanning long distances Wireless transmission via IWLAN with SCALANCE W over medium distances Dedicated line modem MD2 for point-to-point, point-to-multipoint or line connections Wireless devices from various manufacturers, also for private mobile radio using the time slot method Analog dial-up modem MD3 for the analog telephone network or point-to-point dedicated lines ISDN modem MD4 for connecting to the ISDN network Page 1463 Mar 2008 Siemens ITS

Integration Connection to IP-based networks In addition to the RS232 interface, the TIM 3V-IE Advanced also has an RJ45 socket. This is suitable for the connection of IP-based networks (WAN or LAN). Depending on the application, various types of data communication equipment can be connected such as: SCALANCE X switches for Twisted Pair cable or fiber-optic cables SCALANCE W (IWLAN) and Ethernet radio devices from various manufacturers EDGE router MD741-1 for GPRS communication and EGPRS (Edge) over mobile telephone networks SCALANCE M873/875 for UMTS communication via mobile telephone networks GPRS/GSM modem MD720-3 for GPRS communication over mobile telephone networks DSL router and SCALANCE S for VPN (IPsec) DSL router directly by means of MSC-VPN tunnel protocol integrated in the TIM Broadband systems such as OTN and PCM30 Configuration examples with TIM 3V-IE Advanced Use as a station The TIM 3V-IE Advanced can be used as a station like a TIM 3V-IE. In addition, transmission is possible via the direct connection of the TIM to a DSL router (MSC tunnel). Use the MSC tunnel protocol (MSC client) integrated in the TIM 3V-IE Advanced to operate a connection via Industrial Ethernet and a DSL router to a TIM 4R-IE that terminates the MSC tunnel protocol. Page 1464 Mar 2008 Siemens ITS

Use in a node station Page 1465 Mar 2008 Siemens ITS

When used in a node station, TIM 3V-IE Advanced can, for example, exchange data over its RS232 interface over a radio network with the lower-level stations. It is then connected to the control desk over the RJ45 interface, e.g. over a fiberoptic cable, that is connected through SCALANCE X switches. In this configuration, data can be exchanged between each of the SINAUT stations regardless of which network they are situated in. In this case, in order to disconnect the networks, the connection in the control center can be made via a TIM 4R- IE or, as in the example, directly to the Ethernet interface of the PC. Redundant transmission paths Page 1466 Mar 2008 Siemens ITS

Using TIM 3V-IE Advanced, a station can be connected to the control desk over redundant paths. The TIM 3V-IE Advanced is used for this purpose both in the station and in the control center. The example includes a combination of fiber-optic cables and radio paths as redundant paths. The two TIMs coordinate data transmission: It takes place normally over the main path and only if it fails over the standby path. When the main path is restored, changeover back to this path is performed automatically. The TIM 3V-IE Advanced in the control center has access to the MPI interface of the S7-300-CPU via the backplane bus, by which the TIM communicates with the control desk PC (e.g. ST7cc). Note that only certain types of CPU can be considered for this application. A TIM 4R-IE can be used in the control center as a replacement for the TIM 3V-IE Advanced. Without a S7-300-CPU, this TIM is connected to the control desk PC via one of the two Ethernet ports. Page 1467 Mar 2008 Siemens ITS

Use of the MPI port of the local CPU is possible with the following types of CPU: all versions of the CPUs 312, 312C, 313C, 314 and 314C, the CPUs 315-2 DP and 315F-2 DP. Use in a control center The TIM 3V-IE Advanced is also suitable for configuring a control center that comprises more than one TIM. In the following example, the TIM 3V-IE Advanced is combined with a TIM 4R-IE. Both TIMs are connected via the MPI with the CPU inserted in the rack. Both TIMs process data communication with the stations in their own networks and route the data via Industrial Ethernet to the PC. Connection to a conventional WAN Connection to a conventional WAN is via the floating RS232 interface of the TIM 3V-IE Advanced module, via which various modems or data communication equipment can be connected, depending on the application. The RS232 interface can then be operated parallel to the Industrial Ethernet interface. Technical specifications Page 1468 Mar 2008 Siemens ITS

Technical specifications Order No. 6NH7 800-3CA00 Product type designation TIM 3V-IE Advanced Transmission rate Transmission rate with Industrial Ethernet 10 100 Mbit/s Transmission rate in accordance with RS 232 50 38 400 bit/s Interfaces Number of interfaces in accordance with 1 Industrial Ethernet Number of electrical connections For external data transmission in accordance 1 with RS 232 For power supply 1 Design of electrical connection of the Industrial Ethernet interface RJ45 port at interface 1 for external data transmission 9-pin D-sub male connector (RS232) at interface 2 for external data transmission - For power supply 2-pin, pluggable terminal strip Design of the swap medium C-Plug No Page 1469 Mar 2008 Siemens ITS

Supply voltage, current consumption, power loss Type of power supply Power supply Minimum Maximum Current consumed Maximum from backplane bus for 24 V DC Maximum from external power supply for 24 V DC Effective power loss DC 24 V 20.4 V 28.8 V 0.2 A 0.2 A 5.8 W Product expansion: optional backup battery No Type of battery - Backup current Typical - Maximum - Permitted ambient conditions Ambient temperature During operation 0 60 C During storage -40 +70 C During transport -40 +70 C Relative humidity at 25 C without condensation during operation, maximum IP degree of protection 95 % IP20 Page 1470 Mar 2008 Siemens ITS

Design, dimensions and weights Module format Width Height Depth Net weight Product properties, functions, components General Number of modules - Note Cable length Maximum with RS232 interface Maximum with RS485 interface - Performance data Performance data S7 communication Number of possible connections for S7 communication Maximum 24 Maximum with PG connections 4 For OP connections, maximum 20 Note - Service SINAUT ST7 using S7 communication S7-300 compact module, single- width 40 mm 125 mm 120 mm 0.25 kg Number of TIM per S7-300: several, number depends on connection resources of S7-300 CPU 6 m Page 1471 Mar 2008 Siemens ITS

PG/OP communication Performance data Multiprotocol operation Number of active connections in multiprotocol 24 mode Performance data Telecontrol Suitability for use TIM node station TIM station TIM control center Note RS232 and Industrial Ethernet can be used simultaneously Protocol is supported TCP/IP DNP3 No SINAUT ST1 protocol SINAUT ST7 protocol Product function: data buffering if connection is aborted Note 32,000 data frames Memory capacity of S7 CPU's main memory 20 Kibyte Required on CPU for TD7onCPU mode data blocks Page 1472 Mar 2008 Siemens ITS

0 Kibyte Required on TIM for TD7onTIM mode data blocks Note TD7onCPU: at least 20 KB, actual requirement depends on data quantity and functional scope TD7onTIM: 0 bytes in most favorable case Product property: buffered message frame No memory Transmission format 11 bits for SINAUT ST1 protocol with polling 10 or 11 bits for SINAUT ST1 protocol with spontaneous polling 10 bits for SINAUT ST7 protocol with multimaster polling 10 or 11 bits for SINAUT ST7 protocol with polling or spontaneous polling Operating mode with scanning of data transmission With dedicated line/radio link Polling, polling with time slot procedure With SINAUT ST1 protocol Page 1473 Mar 2008 Polling, polling with time slot procedure, Siemens ITS

multi-master polling with time slot procedure With SINAUT ST7 protocol With dial-up network Spontaneous With SINAUT ST1 protocol Spontaneous With SINAUT ST7 protocol Hamming distance For SINAUT ST1 protocol 4 For SINAUT ST7 protocol 4 Product functions Management, configuration, programming Configuration software Required SINAUT ST7 ES Required for CPU configuration: SINAUT TD7 block library for CPU Required for PG configuration: SINAUT ST7 configuration software for PG Storage location of TIM configuration data On the TIM Product functions Security Virtual Private Network Suitability for use of Virtual Private Network Product function Password protection for VPN Page 1474 Mar 2008 Siemens ITS

MSC client via GPRS modem with MSC capability MSC protocol is supported Number of possible connections As MSC client with VPN connection 1 As MSC server with VPN connection 0 MSC protocol supported with Virtual Private TCP/IP Network Key length for MSC with Virtual Private 128 bits Network Type of authentication with Virtual Private Network PSK Virtual Private Network mode - Note - Product functions Time Product component: hardware real-time clock - Product property: buffered hardware real-time - clock Maximum accuracy of hardware real-time - clock per day Page 1475 Mar 2008 Siemens ITS