EliA TM on. Automation and quality in autoimmunity testing

Similar documents
Bio-Rad Laboratories AUTOIMMUNE TESTING. System. PhD. IFA and EIA Instrumentation. One revolutionary platform, two technologies

Data Sheet. Item Specification Comment

COBAS INTEGRA 400 plus

IFA AUTOMATION BEYOND HUMAN BOUNDARIES HELMED IFA PROCESSOR

NEW IMPROVED SCREENING PLATFORM MATERNAL FETAL HEALTH

LIGHT SOURCE Quartz-iodine lamp 12V-20W.

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

Brand Guidelines. Autoimmunity

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

1 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (Max.) 1 plate /run Barcode reader

Leica ST High Throughput. Linear Staining System

Leica EM KMR3. Balanced-break Glass Knife Maker

EasyElectrolytes. With EasyElectrolytes, Medica has redefined electrolyte analyzer design

Random Access Analyzer For Immuno-Assay, Clinical Chemistry & Plasma Proteins

Tissue-Tek Genie. Full Automation, True Random Access For IHC and ISH. Advanced Staining System. continuous innovation for pathology

Your Test Your Workflow Your Freedom. Automated Staining Instrument. Freedom

Issued by: LABORATORY MANAGER Original Date: March 14, 2001 Approved by: Laboratory Director Revision Date: June 6, 2003.

Tecan Cavro components overview. Tecan Cavro innovation is everywhere

Product Overview. Tecan Cavro Components Tecan Cavro innovation is everywhere

Total Flexibility. Proven Quality.

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Installation Qualification Protocol (IQ)

Microplate Systems. Absorbance Microplate Readers 366. Performance Validation and Software Tools 368. Microplate Washer 370

Drinking Water Analysis safe and simplified

FULLY AUTOMATED 2 MICROPLATE ANALYZER

U85026A Detector 40 to 60 GHz

Keysight Technologies 8163B Lightwave Multimeter 8164B Lightwave Measurement System 8166B Lightwave Multichannel System.

PRODUCT DATA. Wideband Ear Simulator Type 4195-Q for Production Line Testing of Telephones

Single column testing machine STENTOR II

Configuring LATITUDE NXT Wave Communicators. Bottom View

Leica FL800. Integrated Vascular Fluorescence. Living up to Life

Mar No.02. widefield Application Letter. resolution. Well Plate Acquisition Wizard

Global Economic Indicators: Global Leading Indicators

Automated Liquid Handling. Smart Benchtop System for Your Lab GeneTheatre

MEXICO (52) NETHERLANDS (31) SINGAPORE (65) SOUTH AFRICA (27) / 5 SPAIN (34)

PerkinElmer Life and Analytical Sciences, Inc. USING THE ALPHASCREEN OMNIBEADS CATALOG NUMBERS: D, M, R

Thermo Scientific IEC CL30 Centrifuge Series Convenience, Reliability and Value

Automated Liquid Handling. Smart Benchtop System for Your Lab GeneTheatre

INDUSTRY DIVISION. Leica LED2000 & Leica LED2500. Microscope Stand and Illumination in One

Thermo Scientific Samco Transfer Pipettes. Precisely what you need

Service withdrawal: Selected IBM ServicePac offerings

A 2 O Advanced Automated Osmometer

Leica EM CPD300. Automated Critical Point Dryer Controlled Specimen Drying for Biological and Industrial Applications

Uploading protocols and Assay Control Sets to the QIAsymphony SP via the USB stick

Budget-Class Analytical and Precision Balances Talent The Affordable Introduction to Sartorius Weighing Technology

Programming Note. Agilent Technologies Quick Reference Guide For the 8757D/E Scalar Network Analyzer

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

A 2 O Advanced Automated Osmometer

LabVIEW DSP Module. Contents. Introduction RELEASE NOTES. Version 1.0

Leica LAS Live Image Builder

8x Independent DMX Controller

PRODUCT DATA. PULSE Vibration Check Systems for Aircraft Engines Types 3647-A, 3647-B including PULSE Standard Configuration 3560-B-T57

Leica BOND III. Fully automated IHC & ISH. Quality. Speed. Efficiency.

ihr Series horiba.com/osd Research Grade Spectrometers Simply the best imaging spectrometers with no compromise

PRODUCT DATA. Conformance Test System for PSTN Telephones Base System Type 6711 (version 2.0)

FP-PS-4. Features. Installation

VISA, SICL, VISA COM,

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

Summit Software WorkList Builder Quick Start Guide

Purchasing. Operations 3% Marketing 3% HR. Production 1%

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9208E 16-Channel, ±20 ma, 24-Bit Analog Input Module

SF5x Series DO-201AD. Page <1> 26/07/08 V1.1. Dimensions : Inches (Millimetres)

PRODUCT DATA. Reporting Module Type 7832

Power Analyzer Firmware Update Utility Version Software Release Notes

Keysight Technologies Multi-Vendor Cellular Networks and Value Driven Optimization. Application Note

Leica Application Suite. Archive

A 2 O Advanced Automated Osmometer

Demo Guide. Keysight Multi-Operator with M937xA PXIe Vector Network Analyzers

Keysight Technologies Monitoring the Control Panel Temperature

Technical Overview. Key Features

InfoPrint 6500 line matrix printer family features new intelligent cartridge ribbon system

REPORT FROM THE COMMISSION TO THE EUROPEAN PARLIAMENT AND THE COUNCIL

CM and SB Series Single Phase Bridge Rectifiers

EventBuilder.com. International Audio Conferencing Access Guide. This guide contains: :: International Toll-Free Access Dialing Instructions

INSTALLATION INSTRUCTIONS LFH160 Cable

Coatron Semi-automated Coagulation Analyzer Series

Agilent U2941A Parametric Test Fixture

HMV Series Ceramic Cased Wirewound Resistors

Marketing Information Bluetooth Wireless Interface

Agilent Noise Source Calibration Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set. Product Note

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

eprep Sample Preparation Workstation

Leica EM AFS2 Automatic Freeze Substitution System. Leica EM FSP Freeze Substitution Processor

N2753A and N2754A Windows XP to Windows 7 Upgrade Kits. For Infiniium 9000, 90000, and X-Series Oscilloscopes

Agilent L4445A Microwave Switch/Attenuator Driver

BCA protein assay kit for low concentrations. For measuring total protein concentration of pure proteins, extracts or lysates.

Keysight Technologies T4020S LTE RRM Test System. Technical Overview

Solutions for Streamline Field Test with Agilent N9342C Handheld Spectrum Analyzer (HSA)

Screw-Less Clamp solutions SOCKETS TIMERS

BC Auto Hematology Analyzer. Pleasant Experience in Hematology Testing

EXPOFACTS. Exposure Factors Sourcebook for Europe GENERAL

SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications

Keysight Technologies

A Profile of European Datacenter Markets: Enterprise Ireland

INSTRUCTION MANUAL CONDUCTIVITY-METER MODEL CC-01

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

CTRL7100A CTRL7100A Instrument Controller

Training Notes Unity Real Time 2

Customers want to transform their datacenter 80% 28% global IT budgets spent on maintenance. time spent on administrative tasks

Leica E Series. Technical information. Living up to Life

Transcription:

EliA TM on Automation and quality in autoimmunity testing

EliA on Phadia 250 the Future in Autoimmunity Testing Now! High Throughput n 350 or more tests per day n additional throughput with over-night runs n results in one-minute intervals n continuous access for samples Highly Automated n true walk-away n automatic wake-up and shut down n barcode reading for all reagents and samples to minimise errors n remote monitoring for easy troubleshooting n primary and secondary tubes accepted Flexibility n patient-specific test profiles n autoimmunity and allergy in one run n small runs cost-efficient n priority function for urgent samples n reflex testing Quality n accurate, standardised and reproducible results n custom-designed, reliable technology dedicated to antibody testing n reagents produced under GMP conditions n regular, system-specific quality control with Quality Club EliA Autoimmunity

The EliA System n Time for the essentials Phadia 250 is a highly automated system for autoimmuni ty (EliA ) and allergy (ImmunoCAP ) testing. Designed to assist laboratory workflow by reducing hands-on time, it processes samples from test request to final result with minimal intervention. Barcode identification of all reagents, mainframe worklist downloads or barcode/manual sample identification combine with on-board dilution to reduce manual handling and minimise errors. Over-night runs with automatic shut down after the last sample and the automated wake-up give the option of in - creasing the available working hours of the instrument. All reagents can be stored on board to minimise loading times. User-friendly operation makes test handling and data processing simple and convenient. n Cost efficient and flexible n Intuitive, user friendly handling The modular EliA system allows for patient-specific, economical routine use. One standard curve is used for all analytes within a method and calibration is required only monthly. The calibration curve is generated and controlled as the instrument runs and raw data for calibrators, controls and patient samples is always accessible, making the entire process transparent and understandable for the user. For every sample, an individual test panel can be compiled. Single samples can be run immediately and prioritised if the results are needed urgently and reflex testing from EliA Symphony to specific ANA analytes is possible. Wide measuring ranges and reproducible results optimise throughput and reduce the secondary-level testing required. To improve the efficiency of the laboratory, autoimmunity and allergy testing can be performed in the same run. The same-day result turnaround system provides the best possible service for clinicians and patients. The unique Phadia Information Data Manager (IDM) software allows the integration of several Phadia instruments (including Phadia 100 Phadia 1000) into one network. IDM manages all results, an in-depth quality control programme as well as the total laboratory stock. Additionally, IDM has a high-capacity patient database and allows a detailed documentation of results. On the instrument itself, logical software accessed via a built-in touch screen, makes the handling of the system very easy.

n Maximum specificity and sensitivity in autoimmunity testing To ensure the highest quality of our autoantibody tests, it is crucial to use very pure, conformationally-correct antigens. We use human recombinant proteins and synthetic peptides whenever it increases antigenicity and thus sensitivity and specificity. The polystyrene EliA Wells are precoated with defined antigens. In the testing process, sample material is pipetted into the EliA well and specific autoantibodies present can bind to the antigen. This binding is detected by the addition of an enzymelabelled conjugate followed by its substrate. The resulting fluorescence is detected by the built-in fluorometer and expressed in EliA Units or International Units, where appropriate. n Automation for walk-away productivity The Phadia 250 system is highly automated, requiring minimal hands-on time. A typical work-day schedule for EliA on Phadia 250 is shown below. Load EliA TM Well Carriers n A boost in service for your laboratory and your clinicians EliA has been specifically designed to offer clinically rele vant results in autoimmunity testing while meeting the laboratory demands of efficient and cost-effective workflow. As specialists in autoimmunity, we offer you all the benefits of our knowledge and experience through our high quality products and our technical and scientific support.

Phadia 250 Stop Solution and Development solution, 2 bottles each. Cooled conjugate compartment for up to 6 conjugate bottles. Sample Diluent (6 bottles) and Dilution Plates (2x96 wells) for on-board dilution of samples. Strip tray for up to 8 Calibrator Strips and/or Curve Control Strips. The moveable table includes the containers for wash solution, rinse solution and for solid and fluid waste. Logical and intuitive system management via touchscreen; a full feature PC and printer are also included in the system. Loading Tray for EliA Well and ImmunoCAP Carriers with 38 stat positions additional to the positions in the storage chamber. Cooled, barcodecontrolled storage chamber for 180 EliA Well / ImmunoCAP Carriers. Positive identification and position sensing system for reagents and samples. Sample racks (5), each holds up to 10 patient and quality control samples.

Technical Information n Size: 127 x 71 x 93 cm (w x d x h) table top n Weight: 220 kg n Power supply: 100, 120, 220, 230, 240 V / 50-60 Hz / 1.2 kva n Environmental temperature: 18-32 C n Data management: Phadia Information Data Manager (IDM), full feature PC connected n Operating system: Windows 2000 / Windows XP n Mainframe connection protocol: ASTM, MasterCAP and Phamas n Clustering: optional n Solid and liquid waste handling: self contained or direct outlet connection n Samples: primary and secondary tubes; serum or plasma EliA Tests Package size Article No. Connective Tissue Diseases EliA CTD Screen 4 x 12 tests 14-5596-01 EliA Symphony 4 x 12 tests 14-5508-01 EliA dsdna 4 x 12 tests 14-5500-01 EliA Sm 4 x 12 tests 14-5502-01 EliA Rib-P 2 x 12 tests 14-5521-01 EliA U1RNP 4 x 12 tests 14-5501-01 EliA RNP70 4 x 12 tests 14-5511-01 EliA Ro 4 x 12 tests 14-5503-01 EliA La 4 x 12 tests 14-5504-01 EliA CENP 2 x 12 tests 14-5505-01 EliA Scl-70 2 x 12 tests 14-5506-01 EliA Jo-1 2 x 12 tests 14-5507-01 Rheumatoid Arthritis EliA CCP 4 x 12 tests 14-5515-01 EliA RF IgM 4 x 12 tests 14-5600-01 EliA RF IgA 4 x 12 tests 14-5601-01 Antiphospholipid Syndrome EliA Cardiolipin IgG 4 x 12 tests 14-5529-01 EliA Cardiolipin IgM 4 x 12 tests 14-5530-01 EliA β2 Glycoprotein I IgG 4 x 12 tests 14-5532-01 EliA β2 Glycoprotein I IgM 4 x 12 tests 14-5533-01 Vasculitis and GBM EliA PR3 S 4 x 12 tests 14-5536-01 EliA MPO 4 x 12 tests 14-5513-01 EliA GBM 2 x 12 tests 14-5514-01 Celiac Disease EliA Celikey IgA 4 x 12 tests 14-5517-01 EliA Celikey IgG 4 x 12 tests 14-5518-01 EliA Gliadin DP IgA 4 x 12 tests 14-5538-01 EliA Gliadin DP IgG 4 x 12 tests 14-5539-01 Phadia GmbH, Munzinger Str. 7, D-79111 Freiburg Germany, Tel: +49 761 47 805 0, Fax: +49 761 47 805 120, autoimmunity@phadia.com, www.phadia.com Head office Sweden +46 18 16 50 00 Austria +43 1 270 20 20 Belgium +32 2 749 55 15 Brazil +55 11 3345 5050 Denmark +45 70 23 33 06 Finland +358 9 8520 2560 France +33 1 6137 3430 Germany +49 761 47 805 0 Italy +39 02 64 163 411 Japan +81 3 5365 8332 Norway +47 21 67 32 80 Portugal +351 21 423 53 50 Spain +34 935 765 800 Distributors +46 18 16 50 00 Switzerland +41 43 343 40 50 Taiwan +886 2 2516 0925 The Netherlands +31 30 602 37 00 United Kingdom / Ireland +44 1908 84 70 34 Other Countries +46 18 16 50 00 Printed on recycled paper Order No. 91 50 002 Freiburg 03/2010