3RP, 7PV Timing Relays

Similar documents
3RA13, 3RA14 Contactor Assemblies

Solid-State Switching Devices

SIRIUS 3RB2 Solid-State Overload Relays

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Electrical Components for the Railway Industry. SIRIUS Relays 3RP, 3RS, 3TX

sirius Switching. Protecting. Starting. SIRIUS Product Overview

Industrial Controls. Time Relays. SIRIUS 3RP25 Time Relays. Gerätehandbuch. Answers for industry. Edition 10/2014

SIRIUS - SIRIUS 3RA28

IEC Contactors. Auxiliary Contact Blocks GENERAL

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

C E R T I F I C A T E O F C O M P L I A N C E

Relays. SIRIUS 3RR24 Monitoring Relays for Mounting onto 3RT2 Contactors for IO-Link. Current and active current monitoring. 10/80 Siemens IC

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

Contactors and Contactor Assemblies

Data sheet. CI-TI TM Contactors and Motor Starters Timers ATI, BTI, MTI 520B1307

Electronic timer CT-ARS.11

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

Load Feeders and Motor Starters for Use in the Control Cabinet

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

Siemens AG up to 12 up to 25 up to 50 up to 100 up to 200 up to S12 Terminal brackets for stand-alone

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

SR60 Busbar System 2/1. 2/2 Busbar routing. 2/3 Mounting components. 2/6 Accessories

Electronic timer CT-ERS.21

Controls Solid-State Switching Devices

IEC Power Control Contactors and Contactor Assemblies

Safety Relays 3TK2845 Multifunction Device

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

Contactors and Contactor Assemblies

Certificate of Compliance

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Industrial Controls Product Catalog 2017

Load Feeders, Motor Starters and Soft Starters

3RT, 3TB, 3TF Contactors for Switching Motors

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

C E R T I F I C A T E O F C O M P L I A N C E

Electronic timers CT range

Solid-State Contactors

Protection Equipment

IEC Power Control Overload Relays

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

IEC Power Control Overload Relays

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

EU Declaration of Conformity

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-AHD.22

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

System-based switching, protecting, starting. SIRIUS Modular System. sirius

Datasheet - SLB 200-C04-1R

Multi Voltage Options. Multi Voltage Options 110VAC + 24VAC/DC 230VAC + 24VAC/DC 24VAC/DC 110VAC 230VAC

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

Electronic time relays ATI, BTI, SDT and MTI

Switching Devices 7/1. 7/4 Product overview. 7/5 5TT5 remote control switches. 7/8 5TT3 0 switching relays. 7/9 5TT5 7 Insta contactors

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

U1602, U1603 ENERGY CONTROL SYSTEM

Offering you the latest innovative products & solutions from Siemens. au.rs-online.com

Standards and approvals

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

If something has to be monitored: A relay for every application. simirel

A2000 Multifunctional Power Meter

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

ict contactors EN 61095, IEC 1095 Interference

Components for Distribution Systems

ETD-BL-1T-OFF-CC- 10S

Zelio Time - timing relays

System-based switching, protecting, starting. SIRIUS Modular System. sirius

PHOENIX CONTACT Features

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Solid-State Switching Devices

ENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

Electronic timer CT-ERD.12

Load Feeders and Motor Starters for Use in the Control Cabinet

Non-communicating room controllers

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

MSR178DP. Description. Features. Specifications

ALPHA SIMBOX Small Distribution Boards

Contactors and Contactor Assemblies

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Phone: Fax: Web: -

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Room Temperature Controller

RZ7-FE Electronic Timing Relays

Lightning and Surge Arresters

5SL Miniature Circuit Breakers

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Transcription:

3RP, PV Timing Relays Overview Standards The timing relays comply with: EN 6021-3-3 "Environmental conditions" EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" EN 61000-6-2 and EN 61000-6-4 "Electromagnetic compatibility" EN 6094-5-1; (VDE 0660 Part 200) "Low-voltage controlgear, switchgear and systems Electromechanical controlgear" 3RP15 timing relays, width Application Timing relays are used in control, starting, and protective circuits for all switching operations involving time delays. They guarantee a high level of functionality and a high repeat accuracy of timer settings. Enclosure design All timing relays are suitable for snap-on mounting onto 35 mm standard mounting rails according to EN 50022 or for screw fixing. LED for indicating "Time relay on voltage" LED for indicating "Relay switched" range selector switch Function switch Decive labeling plate NSB0_01423 Operating time adjustment Inspection window for set time range Inspection window for set function Accessories Push-in lugs for screw mounting Sealable cap Label set for marking the multifunction relay /28 Siemens LV 1 2006

Selection and ordering data mechanical engineering with: 1 changeover or 2 changeover s Rated control supply voltage U s DT Screw-type connection PU V V kg 3RP15 05 timing relays, multifunction, 15 time setting ranges The functions can be adjusted by means of rotary switches. Indicator labels can be used to adjust different functions of the 3RP15 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B. 1) 1 CO, 0.05... 1 s 8 functions 2 CO s, 16 functions 3RP15 05-1B... 2 CO s, positively driven and hard goldplated. 8 functions 4)5) 3RP15 1. timing relays, ON-delay, 1 time setting range 1 CO -- 12 A 3RP15 05-1AA40 1 1 unit 101 0.125 24/100... 12 24 } 3RP15 05-1AQ30 1 1 unit 101 0.140 24/200... 240 24 } 3RP15 05-1AP30 1 1 unit 101 0.141 24... 240 3) 24... 240 3) } 3RP15 05-1AW30 1 1 unit 101 0.136 24/100... 12 24 } 3RP15 05-1BQ30 1 1 unit 101 0.162 24/200... 240 24 } 3RP15 05-1BP30 1 1 unit 101 0.161 24... 240 3) 24... 240 3) } 3RP15 05-1BW30 1 1 unit 101 0.168 400... 440 -- A 3RP15 05-1BT20 1 1 unit 101 0.169 24... 240 24... 240 } 3RP15 05-1RW30 1 1 unit 101 0.169 24/100... 12 24 } 3RP15 11-1AQ30 1 1 unit 101 0.108 24/200... 240 24 } 3RP15 11-1AP30 1 1 unit 101 0.108 24/100... 12 24 } 3RP15 12-1AQ30 1 1 unit 101 0.10 24/200... 240 24 } 3RP15 12-1AP30 1 1 unit 101 0.104 24/100... 12 24 } 3RP15 13-1AQ30 1 1 unit 101 0.10 24/200... 240 24 } 3RP15 13-1AP30 1 1 unit 101 0.108 3RP15 1.-1A... 3RP15 25 timing relays, ON-delay, 15 time setting ranges 3RP15 25.1A... 1 CO 0.05... 1 s 2 CO s 42... 48/60 42... 48/ 3RP15 2 timing relays, ON-delay, two-wire design, 4 time setting ranges 1 NO (semiconductor) 0.05... 1 s 0.2... 4 s 12... 240 s 24/100... 12 24 } 3RP15 25-1AQ30 1 1 unit 101 0.109 24/200... 240 24 } 3RP15 25-1AP30 1 1 unit 101 0.104 60 6) A 3RP15 25-1BR30 1 1 unit 101 0.152 24/100... 12 24 } 3RP15 25-1BQ30 1 1 unit 101 0.152 24/200... 240 6) 24 } 3RP15 25-1BP30 1 1 unit 101 0.155 24... 240 24... 240 3) } 3RP15 25-1BW30 1 1 unit 101 0.159 24... 66 24...66 6) A 3RP15 2-1EC30 1 1 unit 101 0.099 90... 240 90...240 3) } 3RP15 2-1EM30 1 1 unit 101 0.100 3RP15 2-1E... 1) For functions, see 3RP19 01-0. label set. 2) With switch position Š, no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 3) Operating range 0. to 1.1 x U s. 4) Positively driven: NO and NC are never closed simultaneously; gap >= 0.5 mm is ensured, minimum make-break capacity 12 V, 3 ma. 5) The changeover s are actuated simultaneously, as a result of which only 8 functions are selectable (no wye-delta, no instantaneous ). 6) Operating range 0.8 to 1.1 x U s. Siemens LV 1 2006 /29

mechanical engineering with: 1 changeover or 2 changeover s Rated control supply voltage U s DT Spring-loaded terminal PU V V kg 3RP15 05 timing relays, multifunction, 15 time setting ranges The functions can be adjusted by means of rotary switches. Indicator labels can be used to adjust different functions of the 3RP15 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B. 1) 1 CO, 0.05... 1 s 8 functions 2 CO s, 16 functions 2 CO s, positively driven and hard goldplated. 8 functions 4)5) 3RP15 1. timing relays, ON-delay, 1 time setting range 1 CO 24/100... 12 24 C 3RP15 05-2AQ30 1 1 unit 101 0.125 24/200... 240 24 A 3RP15 05-2AP30 1 1 unit 101 0.126 24... 240 3) 24... 240 3) A 3RP15 05-2AW30 1 1 unit 101 0.132 24/100... 12 24 A 3RP15 05-2BQ30 1 1 unit 101 0.142 24/200... 240 24 A 3RP15 05-2BP30 1 1 unit 101 0.13 24... 240 3) 24... 240 3) A 3RP15 05-2BW30 1 1 unit 101 0.143 24... 240 24... 240 A 3RP15 05-2RW30 1 1 unit 101 0.143 24/100... 12 24 C 3RP15 11-2AQ30 1 1 unit 101 0.092 24/200... 240 24 A 3RP15 11-2AP30 1 1 unit 101 0.092 24/100... 12 24 C 3RP15 12-2AQ30 1 1 unit 101 0.092 24/200... 240 24 A 3RP15 12-2AP30 1 1 unit 101 0.09 1 24/100... 12 24 C 3RP15 13-2AQ30 1 unit 101 0.094 24/200... 240 24 C 3RP15 13-2AP30 1 1 unit 101 0.094 3RP15 25 timing relays, ON-delay, 15 time setting ranges 1 CO 0.05... 1 s 24/100... 12 24 C 3RP15 25-2AQ30 1 1 unit 101 0.095 24/200... 240 24 A 3RP15 25-2AP30 1 1 unit 101 0.093 2 CO s 24/100... 12 24 C 3RP15 25-2BQ30 1 1 unit 101 0.128 24/200... 240 24 A 3RP15 25-2BP30 1 1 unit 101 0.12 24... 240 6) 24... 240 3) A 3RP15 25-2BW30 1 1 unit 101 0.134 3RP15 2 timing relays, ON-delay, two-wire design, 4 time setting ranges 1 NO 0.05... 1 s 24... 66 24...66 6) C 3RP15 2-2EC30 1 1 unit 101 0.090 (semiconductor) 0.2... 4 s 90... 240 90...240 3) C 3RP15 2-2EM30 1 1 unit 101 0.090 12... 240 s 1) For functions, see 3RP19 01-0. label set. 2) With switch position Š, no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 3) Operating range 0. to 1.1 x U s. 4) Positively driven: NO and NC are never closed simultaneously; gap >= 0.5 mm is ensured, minimum make-break capacity 12 V, 3 ma. 5) The changeover s are actuated simultaneously, as a result of which only 8 functions are selectable (no wye-delta, no instantaneous ). 6) Operating range 0.8 to 1.1 x U s. /30 Siemens LV 1 2006

mechanical engineering with: 1 changeover or 2 changeover s Rated control supply voltage U s DT Screw-type connection PU V V kg 3RP15 3. timing relays, OFF-delay, with auxiliary voltage, 1 time setting range 1 CO The same potential must be applied to terminals A and B. 24/100... 12 24 A 3RP15 31-1AQ30 1 1 unit 101 0.140 24/200... 240 24 } 3RP15 31-1AP30 1 1 unit 101 0.140 24/100... 12 24 A 3RP15 32-1AQ30 1 1 unit 101 0.138 24/200... 240 24 } 3RP15 32-1AP30 1 1 unit 101 0.139 24/100... 12 24 A 3RP15 33-1AQ30 1 1 unit 101 0.139 24/200... 240 24 } 3RP15 33-1AP30 1 1 unit 101 0.140 3RP15 3.-1A... 3RP15 40 timing relays, OFF-delay, without auxiliary voltage, time setting ranges 1) 1 CO 0.05... 1 s 0.3... 6 s 3... 60 s 24 24 2) } 3RP15 40-1AB30 1 1 unit 101 0.116 100... 12 100...12 3) } 3RP15 40-1AJ30 1 1 unit 101 0.119 200... 240 200...240 3) } 3RP15 40-1AN30 1 1 unit 101 0.120 2 CO s 24 24 2) } 3RP15 40-1BB30 1 1 unit 101 0.159 100... 12 100...12 3) A 3RP15 40-1BJ30 1 1 unit 101 0.161 200... 240 200...240 3) } 3RP15 40-1BN30 1 1 unit 101 0.161 3RP15 40-1.A... 3RP15 55 timing relays, clock-pulse relay, 15 time setting ranges 0.05... 1 s 42... 48/60 42...48/ 1 CO 60 5) A 3RP15 55-1AR30 1 1 unit 101 0.111 24/100... 12 24 } 3RP15 55-1AQ30 1 1 unit 101 0.111 24/200... 240 24 } 3RP15 55-1AP30 1 1 unit 101 0.111 3RP15 55-1A... Š 4) 3RP15 60 timing relays, wye-delta function, dead interval 50 ms and overtravel time, 1 time setting range 3 NO s 3) (common root terminal 1) wye-delta 1... 20 s, overtravel time (idling) 30... 600 s 24/100... 12 24 A 3RP15 60-1SQ30 1 1 unit 101 0.12 24/200... 240 24 } 3RP15 60-1SP30 1 1 unit 101 0.15 3RP15 60-1S... 3RP15. timing relays, wye-delta function 6), dead interval 50 ms, 1 time setting range 1 NO 1... 20 s 24/100... 12 24 } 3RP15 4-1NQ30 1 1 unit 101 0.113 instantaneous and 24/200... 240 24 } 3RP15 4-1NP30 1 1 unit 101 0.113 1 NO 200... 240/ -- B 3RP15 4-1NM20 1 1 unit 101 0.113 delayed 380...440 (common 3... 60 s 24/100... 12 24 } 3RP15 6-1NQ30 1 1 unit 101 0.112 root terminal 1) 24/200... 240 24 } 3RP15 6-1NP30 1 1 unit 101 0.113 200... 240/ -- B 3RP15 6-1NM20 1 1 unit 101 0.113 380...440 3RP15.-1N... 1) Setting of output s in as-supplied state not defined (bistable relay). Application of the control voltage once results in changeover to the correct setting. 2) Operating range 0. to 1.25 x U s. 3) Operating range 0.85 to 1.1 x U s. 4) With switch position Š, no timing. For test purposes (ON/OFF function) on site. For dead time "infinite", the relay is always off. For pulse time "infinite", the relay is always on. 5) Operating range 0.8 to 1.1 x U s. 6) For typical circuit see Schematics. Siemens LV 1 2006 /31

mechanical engineering with 1 changeover or 2 changeover s Rated control supply voltage U s DT Spring-loaded terminal PU V V 1) Setting of output s in as-supplied state not defined (bistable relay). Application of the control voltage once results in changeover to the correct setting. 2) Operating range 0. to 1.25 x U s. 3) Operating range 0.85 to 1.1 x U s. 4) With switch position Š, no timing. For test purposes (ON/OFF function) on site. For dead time "infinite", the relay is always off. For pulse time "infinite", the relay is always on. 5) Operating range 0.8 to 1.1 x U s. 6) For typical circuit see Schematics. per unit/ set/ meter 3RP15 3. timing relays, OFF-delay, with auxiliary voltage, 1 time setting range 24/100... 12 24 C 3RP15 31-2AQ30 1 1 unit 101 0.124 1 CO 24/200... 240 24 A 3RP15 31-2AP30 1 1 unit 101 0.122 The same 24/100... 12 24 C 3RP15 32-2AQ30 1 1 unit 101 0.125 potential must 24/200... 240 24 C 3RP15 32-2AP30 1 1 unit 101 0.121 be applied to terminals A and 24/100... 12 24 C 3RP15 33-2AQ30 1 1 unit 101 0.123 B 24/200... 240 24 C 3RP15 33-2AP30 1 1 unit 101 0.125 3RP15 40 timing relays, OFF-delay, without auxiliary voltage, time setting ranges 1) 1 CO 0.05... 1 s 0.3... 6 s 3... 60 s 24 24 2) A 3RP15 40-2AB30 1 1 unit 101 0.105 100... 12 100...12 3) A 3RP15 40-2AJ30 1 1 unit 101 0.108 200... 240 200...240 3) A 3RP15 40-2AN30 1 1 unit 101 0.110 2 CO s 24 24 2) A 3RP15 40-2BB30 1 1 unit 101 0.136 100... 12 100...12 3) C 3RP15 40-2BJ30 1 1 unit 101 0.136 200... 240 200...240 3) C 3RP15 40-2BN30 1 1 unit 101 0.136 3RP15 55 timing relays, clock-pulse relay, 15 time setting ranges 0.05... 1 s 42... 48/60 42...48/60 5) C 3RP15 55-2AR30 1 1 unit 101 0.102 1 changeover 24/100... 12 24 C 3RP15 55-2AQ30 1 1 unit 101 0.100 Š 4) 24/200... 240 24 A 3RP15 55-2AP30 1 1 unit 101 0.104 3RP15 60 timing relays, wye-delta function, dead interval 50 ms and overtravel time, 1 time setting range wye-delta 1... 20 s, overtravel time (idling) 30... 600 s 3RP15. timing relays, wye-delta function 6), dead interval 50 ms, 3 NO s 3) (common root terminal 1) 1 time setting range 1 NO instantaneous and 1 NO delayed (common root terminal 1) 24/200... 240 24 C 3RP15 60-2SP30 1 1 unit 101 0.152 1... 20 s 24/200... 240 24 A 3RP15 4-2NP30 1 1 unit 101 0.104 200... 240/ B 3RP15 4-2NM20 1 1 unit 101 0.100 380...440 3... 60 s 24/100... 12 24 C 3RP15 6-2NQ30 1 1 unit 101 0.102 24/200... 240 24 A 3RP15 6-2NP30 1 1 unit 101 0.104 200... 240/ 380... 440 B 3RP15 6-2NM20 1 1 unit 101 0.100 kg /32 Siemens LV 1 2006

Accessories Label sets Function Code letter Application Accessory for 3RP 15 05 (not included in the scope of supply). The label set offers the possibility of labeling timing relays with the set function in English and German. With ON-delay A for B 1 label set OFF-delay with auxiliary voltage (1 unit) with 8 ON-delay and OFF-delay with functions auxiliary voltage Flashing, starting with interval Passing make Passing break with auxiliary voltage Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary voltage With ON-delay A for B 1 label set OFF-delay with auxiliary voltage (1 unit) with 16 ON-delay and OFF-delay with functions auxiliary voltage Flashing, starting with interval Passing make Passing break with auxiliary voltage Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary voltage and instantaneous ON-delay and instantaneous OFF-delay with auxiliary voltage and instantaneous ON-delay and OFF-delay with auxiliary voltage and instantaneous Flashing, starting with interval, and instantaneous Passing make and instantaneous Passing break with auxiliary voltage and instantaneous Pulse-forming with auxiliary voltage and instantaneous C D E F H C D E F H A B C D E F G with 1 CO and 3RP15 05-.RW30 with 2 CO s DT Order No. Price PU kg } 3RP19 01-0A 1 5 units 101 0.003 } 3RP19 01-0B 1 5 units 101 0.006 Wye-delta function *D Blank labeling plates Blank labeling plates, 101 22.000 20 mm x mm, pastel turquoise 1) C 3RT19 00-1SB20 100 340 units Covering caps and push-in lugs Push-in lugs for screw mounting for with 1 or 2 CO s } 3RP19 03 1 10 units 101 0.002 Sealable caps for securing against unauthorized adjustment of setting knobs for with 1 or 2 CO s } 3RP19 02 1 5 units 101 0.004 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. Siemens LV 1 2006 /33