ADEMCO LYNXR-ENSIA Security System

Ademco/Protection One 250P1-1 Programming Form

Property of Monitronics Inc

3 6HFXULW\6\VWHP 3URJUDPPLQJ)RUP K4332 9/99 BYPASS NOT READY ARMED READY 4 MAX 5 TEST 6 BYPASS 7INSTANT 8 CODE 9CHIME READY ARMED

Property of Monitronics Inc

CUSTOMER INFORMATION

Property of Monitronics Inc

First Alert FA160C/162C Installer Notes M. Leuck

DAYLIGHT SAVINGS TIME START/END MONTH [ 0 ]0 = Disabled; 1 = Enabled. 1 Start End

Installer Notes 4110DL/XM, Vista 10, Vista-20, Via-30PSE

VISTA-20SEa. 3-Partition Security System. Programming Form. V20SEaPRV1 9/98

VISTA-20BAY PROGRAMMING GUIDE SECURITY SYSTEM SINCE 1946

Ademco Vista-20SE/First Alert FA-162C Program Sheet

VISTA-128BP/VISTA-250BP Programming Form

4140XMPT2 PROGRAMMING FORM

Lynx Plus Security System

FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

LYNX Security System 3URJUDPPLQJ)RUP 6XPPDU\RI&RQQHFWLRQV. Features Q.E.D. programming for quick enrollment of devices.

VISTA-50P VISTA-50PUL

5HDG\*XDUG56HULHV 6H XULW\6\VWHPV 3URJUDPPLQJ*XLGHIRU5HDG\*XDUG5DQG 5HDG\*XDUG5(1 K /01 OFF AWAY STAY AUX

APX32EN Security Systems

Property of Monitronics Inc

Commercial Fire and Burglary Partitioned Security System with Scheduling. Programming Guide. K0376PRV5 2/11 Rev. A

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

Commercial Burglary Partitioned Security System With Scheduling. Programming Guide. K5894PRV4 6/04 Rev A

ADEMCO VISTA-48A Security Systems

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

High Security and Access System EVO48 V2.1 EVO192 V2.1

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

Series. NX-8-EUR Control Panel. Installation manual

3DUWLWLRQHG6HFXULW\6\VWHPV ZLWK6FKHGXOLQJ

2 IDS LCD Keypad User Manual C Issued March 2009

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

VISTA-40. Programming Guide. 2-Partition Security System. Single Partition and 2-Partition Programming Forms N7001PRV4 7/98

Telephone and Reporting Setup in ElkRP

Programming Worksheets

PROGRAMMING HELP GUIDE

D1260/D1260B. Owner's Manual. Keypad

MG/SP Series (V4.9/V5.1) What s New

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

Digiplex EVO High Security and Access System What s New EVO192 V2.7

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Installation Instructions

Important Notice. Customer Information. 2 WisDom User Manual

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

IDS X-Series User Manual E Issued June 2013

DAS LCD ALPHA NUMERIC CODEPAD

VISTA-50PADT VISTA-50PADTUL

NX-148 LCD KEYPAD INSTALLATION MANUAL

NetworX Series NX-8V2 Control Panel Installation and Startup

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Modules Programming Guide. paradox.com

Control Panels D9412GV4/D7412GV4. en Owner's Manual

INSTALLATION MANUAL. Table of Contents. General Description Position Dip Switch Settings Enrolling the NX216-E Expander...

DAS ALPHA NUMERIC LCD CODEPAD INSTALLATION MANUAL

Control Panels B9512G/B8512G/B6512/B5512/B4512/B3512. en Owner's Manual

(To modify t he installer code, ref er to section [ 1000], Installer Code Programming on page 21) 1234 or

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

English. Emergency Dialer DIAL-ALERT MODEL : AD-433S 101A320 JUNE, 2004

EVOHD. Programming Guide. Version

i Note Intrusion Control Panel Solution 64 Release Notes for Version Release Notes March, 2007

Solution 16 plus. User Guide Security System

Wireless Alarm System User Guide

Agility Installation Quick Start Guide 1

IDS1200 INSTALLER MANUAL. Summary of Operation 2 IDS1200 INSTALLER MANUAL - NO B ISSUED AUGUST 2002 VER 1.18

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Rins 160 Issue 2

FOCUS 200 PLUS A CCC #: _ / / _ / ( _ ) _ - 35(/,0,1$5< -8/< Security Services CUSTOMER CONTROL UNIT TELEPHONE NUMBER:

SECURITY MODULE CG3 User Manual

Silencing an Alarm Note: Area Systems

XR150/XR350/XR550 USER S GUIDE

Quick Start: 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 44).

AMAX panel. AMAX panel 2100 AMAX panel 3000 AMAX panel 3000 BE AMAX panel en Operation Manual

Silencing an Alarm Note: Area Systems

Emergency Dialer DIAL-ALERT MODEL: AD-105.

Solution 144 Security Systems

LCD User Station User Manual

Emergency Dialer DIAL-ALERT MODEL: AD-433S.

TM50 Touch Intuitive Touchscreen

Installation Quick Start Guide

Rev P July 2003 ZZZ*(,QWHUORJL[FRP. Part No: WIN. ToolBox for Windows. User s Guide

ATLAS 8 PLUSTM USER GUIDE LED & LCD. Intelligent Security & Fire Ltd Rins 160 Issue 6

ELECTRONIC ENGINEERING LTD. OLED Keypad. User s Guide. P/N: Doc Rev-A SW Ver /08/10

KarizmaPlus Intruder alarm system Operating instructions

NX1192E LCD KEYPAD INSTALLATION MANUAL. Table of Contents ENTERING THE PROGRAM MODE... 2 SELECTING THE MODULE TO PROGRAM... 2

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

NX-1248E LCD KEYPAD Installation and Setup

VISTA-120. Installation and Setup Guide. Partitioned Security System with Scheduling. N5944-8V1 Rev. B 6/99

NetworX Series. NX-148E LCD Keypad NX-148E-CF LCD Keypad Installation and Setup

MCM Electronics MCM Electronics MCM Electronics. The Icon Series. Installation and Programming Information. Icon 8 Version 5.0

INT-KSG Keypad Quick user s guide

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Security System User Guide

PROGRAMMING AND INSTALLATION MANUAL

Transcription:

Lynx Plus Control Defaults Lynx Plus Series Installation and Setup Guide *20 Installer code 4112 4112 4112 4112 *21 Quick arm enable 1 1 1 1 *22 Keypad backlight timeout 0 0 0 0 *23 Forced bypass 0 0 0 0 *24 RF house ID code 0,0 0,0 0,0 0,0 *25 Powerline carrier device house code 0 0 0 0 *26 Chime-by-zone 0 0 0 0 *27 Real-time clock display 1 1 1 1 *29 Daylight saving time start/end month 3,11 3,11 3,11 3,11 *30 Daylight saving time start/end weekend 2,1 2,1 2,1 2, 1 *31 Single alarm sounding per zone 0 0 0 0 *32 Sounder timeout 0 0 0 0 *33 Alarm bell timeout 1 1 1 1 *34 Exit delay 7,0 6,0 7,0 7,0 *35 Entry delay 1 (zone type 01) 3,0 4,5 3,0 3,0 *36 Entry delay 2 (zone type 02) 6,0 6,0 6,0 6,0 *37 Audible exit warning/quick exit 1,1 0,1 1,1 1,1 *38 Confirmation of arming ding 0 0 0 0 *39 Power up in previous state 1 1 1 1 *40 PABX access code --- --- --- --- *41 Primary phone number --- --- --- --- *42 Secondary phone number --- --- --- --- *43 Primary subscriber account number 15,15,15,15 15,15,15,15 15,15,15,15 15,15,15,15 *44 Secondary subscriber account number 15,15,15,15 15,15,15,15 15,15,15,15 15,15,15,15 *46 Follow Me Reminder Phone Number --- --- --- --- *47 Phone system select 5 5 5 5 *48 Report format 7,7 7,7 7,7 7,7 *49 Split/dual reporting 0 0 0 9 *50 15 second dialer delay (burglary) 0 1 0 0 *51 Periodic test report 0 3 0 0 *52 First test report offset 2 2 2 2 *53 Sescoa/radionics select 0 0 0 0 *54 Lack of usage notification 0 0 0 0 *55 Reporting Channels 0 0 0 0 *56 Enhanced Zone programming See *56 table See *56 table See *56 table See *56 table *58 RF jam detection 0 0 0 0 *59 Exit error report code 1 0 1 1 *60 Trouble report code 1,0 1,0 1,0 1,0 *61 Bypass report code 0,0 0,0 0,0 0,0 *62 AC loss report code 0,0 0,0 0,0 0,0 *63 Low battery Report code 1,0 1,0 1,0 1,0 *64 Test report code 1,0 1,0 1,0 1,0 *65 Open report code 0 0 0 0 *66 Arm away/stay report code 0,0 0,0 0,0 0,0 *67 RF transmitter low battery report code 1,0 1,0 1,0 1,0 *68 Cancel report code 1,0 1,0 1,0 1,0 *70 Alarm restore codes 1 1 1 1 *71 Trouble restore report code 1,0 1,0 1,0 1,0 *72 Bypass restore report code 0,0 0,0 0,0 0,0 *73 AC restore report code 0,0 0,0 0,0 0,0 *74 Low battery restore report code 1,0 1,0 1,0 1,0 *75 RF transmitter low battery restore report code 1,0 1,0 1,0 1,0 *76 Test restore report code 0,0 1,0 0,0 0,0 *77 Dynamic Signaling Delay/ Dynamic Signaling Priority 0,0 0,0 0,0 0,0 *78 Programmable Tone Generation Time 0,0 0,0 0,0 0,0 *80 Powerline Carrier Devices See *80 table See *80 table --- See *80 table *81 Zone lists for devices See *81 table See *81 table See *81 table See *81 table *84 Assign zone voice descriptors Refer to *84 Programming *86 Multi-mode (E-mail notification) 0 0 0 0-67 -

Lynx Plus Series Installation and Setup Guide Lynx Plus Control Defaults *87 Auxiliary Function/ 1-button paging 0 1 0 1 *88 Pager characters --- --- --- --- *89 Event log 80% full report code 0,0 0,0 0,0 0,0 *90 Event logging 3 15 3 3 *91 Alarm audio verification/remote phone control 2 2 2 2 *92 Number of reports in armed period 0 0 0 0 *93 Flexible call back 0 0 0 0 *94 Download phone number --- --- --- --- *95 Ring detect count for downloading/remote phone control 15 15 15 15 Default Master Code 1,2,3,4 1,2,3,4 1,2,3,4 1,2,3,4 Default Duress Code --- --- --- --- By activating *96, Field 43, and 44 will be changed to 15, 15, 15, 15. - 68 -

LynxSIA Plus Control Defaults Lynx Plus Series Installation and Setup Guide *20 Installer code 4112 4112 4112 4112 *21 Quick arm enable 1 1 1 1 *22 Keypad backlight timeout 0 0 0 0 *23 Forced bypass 0 0 0 0 *24 RF house ID code 0,0 0,0 0,0 0,0 *25 Powerline carrier device house code 0 0 0 0 *26 Chime-by-zone 0 0 0 0 *27 Real-time clock display 1 1 1 1 *29 Daylight saving time start/end month 3,11 3,11 3,11 3,11 *30 Daylight saving time start/end weekend 2,1 2,1 2,1 2,1 *31 Single alarm sounding per zone 0 0 0 0 *32 Fire sounder timeout 0 0 0 0 *33 Alarm bell timeout 1 1 1 1 *34 Exit delay 6,0 6,0 6,0 7,0 *35 Entry delay 1 (zone type 01) 3,0 3,0 3,0 3,0 *36 Entry delay 2 (zone type 02) 3,0 3,0 3,0 3,0 *38 Confirmation of arming ding 0 0 0 0 *39 Cross zone timer 0 0 0 0 *40 PABX access code/call waiting disable --- --- --- --- *41 Primary phone number --- --- --- --- *42 Secondary phone number --- --- --- --- *43 Primary subscriber account number 15,15,15,15 15,15,15,15 15,15,15,15 15,15,15,15 *44 Secondary subscriber account number 15,15,15,15 15,15,15,15 15,15,15,15 15,15,15,15 *46 Follow Me Reminder Phone Number --- --- --- --- *47 Phone system select 5 5 5 5 *48 Report format for primary/secondary 7,7 7,7 7,7 7,7 *49 Split/dual reporting 0 0 0 9 *50 Burglary abort window 2 2 2 2 *51 Periodic test report 0 3 0 0 *52 First test report offset 2 2 2 2 *53 Sescoa/radionics select 0 0 0 0 *54 Lack of usage notification 0 0 0 0 *55 Reporting channels 0 0 0 0 *56 Enhanced zone programming See *56 table See *56 table See *56 table See *56 table *57 False alarm options 7 7 7 7 *58 RF jam detection 0 0 0 0 *59 Exit error report code 1 1 1 1 *60 Trouble report code 1,0 1,0 1,0 1,0 *61 Bypass report code 0,0 0,0 0,0 0,0 *62 AC loss report code 0,0 0,0 0,0 0,0 *63 Low battery Report code 1,0 1,0 1,0 1,0 *64 Test report code 1,0 1,0 1,0 1,0 *65 Open report code 0 0 0 0 *66 Arm away/stay report code 0,0 0,0 0,0 0,0 *67 RF transmitter low battery report code 1,0 1,0 1,0 1,0 *68 Cancel report code 1,0 1,0 1,0 1,0 *69 Recent close report code 1 1 1 1 *70 Alarm restore codes 1 1 1 1 *71 Trouble restore report code 1,0 1,0 1,0 1,0 *72 Bypass restore report code 0,0 0,0 0,0 0,0 *73 AC restore report code 0,0 0,0 0,0 0,0 *74 Low battery restore report code 1,0 1,0 1,0 1,0 *75 RF transmitter low battery restore report code 1,0 1,0 1,0 1,0 *76 Test restore report code 1,0 1,0 1,0 1,0 *77 Dynamic Signaling Delay/ Dynamic Signaling Priority 0,0 0,0 0,0 0,0 *78 Programmable Tone Generation Time 0,0 0,0 0,0 0,0 *80 Powerline Carrier Devices See *80 table See *80 table --- See *80 table *81 Zone lists for devices See *81 table See *81 table See *81 table See *81 table - 69 -

Lynx Plus Series Installation and Setup Guide LynxSIA Plus Control Defaults *84 Assign zone voice descriptors Refer to *84 Programming *86 Multi-mode (E-mail notification) 0 0 0 0 *87 Auxiliary Function/ 1-button paging 0 1 0 1 *88 Pager characters --- --- --- --- *89 Event log 80% full report code 0,0 0,0 0,0 0,0 *90 Event logging 3 15 3 3 *91 Alarm audio verification/remote phone control 2 2 2 2 *92 Swinger shutdown 1 1 1 1 *93 Flexible call back 0 0 0 0 *94 Download phone number --- --- --- --- *95 Ring detect count for downloading/remote phone control 15 15 15 15 Default Master Code 1,2,3,4 1,2,3,4 1,2,3,4 1,2,3,4 Default Duress Code --- --- --- --- By activating *96, Field 43, and 44 will be changed to 15, 15, 15, 15. - 70 -

- 71 - Lynx Plus Series Installation and Setup Guide 56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 1 Zone No. Zone Type Alarm Code Input Type Loop Number Zone Descriptor 1 00 0,0 --- --- 2 01 1,0 3 (RF) 2 47, 04 (FRONT DOOR) 3 01 1,0 3 (RF) 2 33, 04 (BACK DOOR) 4 03 1,0 3 (RF) 2 80 (WINDOW) 5 10 1,0 3 (RF) 1 56 (MOTION DETECTOR) 26 21 1,0 5 (BR) 3 27 22 1,0 5 (BR) 2 28 20 1,0 5 (BR) 4 29 23 0,0 5 (BR) 1 30 21 1,0 5 (BR) 3 31 22 1,0 5 (BR) 2 32 20 1,0 5 (BR) 4 33 23 0,0 5 (BR) 1 92 --- 1,0 --- --- 99 06 1,0 --- --- NOTE: Zone 1 is a hardwire zone; Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic 56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLE 2 Zone No. Zone Type Alarm Code Input Type Loop Number Zone Descriptor 1 00 0,0 --- --- 2 01 1,0 3 (RF) 2 47, 04 (FRONT DOOR) 3 01 1,0 3 (RF) 2 33, 04 (BACK DOOR) 4 01 1,0 3 (RF) 2 48, 04 (GARAGE DOOR)) 5 04 1,0 3 (RF) 1 56 (MOTION DETECTOR) 6 09 1,0 3 (RF) 1 22, 02 (SMOKE DETECTOR) 26 21 1,0 5 (BR) 3 27 22 1,0 5 (BR) 2 28 20 1,0 5 (BR) 4 29 23 0,0 5 (BR) 1 30 21 1,0 5 (BR) 3 31 22 1,0 5 (BR) 2 32 20 1,0 5 (BR) 4 33 23 0,0 5 (BR) 1 92 --- 1,0 --- --- 95 08 1,0 --- --- 96 09 1,0 --- --- 99 07 1,0 --- --- NOTE: Zone 1 is a hardwire zone; Zone 2 to 41 are RF zones; Zone 92 is Duress; Zones 95, 96 and 99 are keypad panics 56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLES 3 & 4 Zone No. Zone Type Alarm Code Input Type Loop Number Zone Descriptor 1 00 0,0 --- --- 2 01 1,0 3 (RF) 2 47, 04 (FRONT DOOR) 3 01 1,0 3 (RF) 2 33, 04 (BACK DOOR) 4 03 1,0 3 (RF) 2 80 (WINDOW) 5 03 1,0 3 (RF) 2 80 (WINDOW) 6 03 1,0 3 (RF) 2 80 (WINDOW) 7 03 1,0 3 (RF) 2 80 (WINDOW) 8 10 1,0 3 (RF) 1 56 (MOTION DETECTOR) 9 09 1,0 3 (RF) 1 22, 02 (SMOKE DETECTOR) 26 21 1,0 5 (BR) 3 27 22 1,0 5 (BR) 2 28 23 0,0 5 (BR) 4 29 23 0,0 5 (BR) 1 30 21 1,0 5 (BR) 3 31 22 1,0 5 (BR) 2 32 23 0,0 5 (BR) 4 33 23 0,0 5 (BR) 1 92 --- 1,0 --- --- 99 06 1,0 --- --- NOTE: Zone 1 is a hardwire zone; Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic

Lynx Plus Series Installation and Setup Guide 80 DEFAULT TABLE: Applies to Default Tables 1 and 2 (devices 01-07 have no default values, devices 09-15 have all default values set to 00) Start Stop Device Number Action Event Zone List Zone Type System Operation Restore of Zone List Zone type System operation 08** 2 33 36 16 2 33 36 80 DEFAULT TABLE: Applies to Default Table 4 (devices 02-07 have no default values, devices 10-15 have all default values set to 00) Start Stop Device Number Action Event Zone List Zone Type System Operation Restore of Zone List Zone type System operation 01 2 2 1 2 08** 2 33 36 09 2 2 1 2 16 2 33 36 ** NOTE: If using an X10 Powerhouse Security SH10A siren as device 08, you must change the device action default to 3. 81 DEFAULT TABLE: Applies to Default Tables 1-4 ZONE LIST FOR OUTPUT DEVICES Zone List 1 28, 32 Zone List 2 29, 33 Zone List 3 2, 3-72 -